15 resultados para fixed-time AI

em Université de Lausanne, Switzerland


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Imaging mass spectrometry (IMS) is useful for visualizing the localization of phospholipids on biological tissue surfaces creating great opportunities for IMS in lipidomic investigations. With advancements in IMS of lipids, there is a demand for large-scale tissue studies necessitating stable, efficient and well-defined sample handling procedures. Our work within this article shows the effects of different storage conditions on the phospholipid composition of sectioned tissues from mouse organs. We have taken serial sections from mouse brain, kidney and liver thaw mounted unto ITO-coated glass slides and stored them under various conditions later analyzing them at fixed time points. A global decrease in phospholipid signal intensity is shown to occur and to be a function of time and temperature. Contrary to the global decrease, oxidized phospholipid and lysophospholipid species are found to increase within 2 h and 24 h, respectively, when mounted sections are kept at ambient room conditions. Imaging experiments reveal that degradation products increase globally across the tissue. Degradation is shown to be inhibited by cold temperatures, with sample integrity maintained up to a week after storage in −80 °C freezer under N2 atmosphere. Overall, the results demonstrate a timeline of the effects of lipid degradation specific to sectioned tissues and provide several lipid species which can serve as markers of degradation. Importantly, the timeline demonstrates oxidative sample degradation begins appearing within the normal timescale of IMS sample preparation of lipids (i.e. 1-2 h) and that long-term degradation is global. Taken together, these results strengthen the notion that standardized procedures are required for phospholipid IMS of large sample sets, or in studies where many serial sections are prepared together but analyzed over time such as in 3-D IMS reconstruction experiments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To better assess biomonitoring data in workers exposed to captan and folpet, the kinetics of ring metabolites [tetrahydrophthalimide (THPI), phthalimide (PI) and phthalic acid] were determined in urine and plasma of dermally exposed volunteers. A 10  mg kg(-1) dose of each fungicide was applied on 80  cm(2) of the forearm and left without occlusion or washing for 24  h. Blood samples were withdrawn at fixed time periods over the 72  h following application and complete urine voids were collected over 96  h post-dosing, for metabolite analysis. In the hours following treatment, a progressive increase in plasma levels of THPI and PI was observed, with peak levels being reached at 24  h for THPI and 10  h for PI. The ensuing elimination phase appeared monophasic with a mean elimination half-life (t(½) ) of 24.7 and 29.7 h for THPI and PI, respectively. In urine, time courses PI and phthalic acid excretion rate rapidly evolved in parallel, and a mean elimination t(½) of 28.8 and 29.6  h, respectively, was calculated from these curves. THPI was eliminated slightly faster, with a mean t(½) of 18.7  h. Over the 96  h period post-application, metabolites were almost completely excreted, and on average 0.02% of captan dose was recovered in urine as THPI while 1.8% of the folpet dose was excreted as phthalic acid and 0.002% as PI, suggesting a low dermal absorption fraction for both fungicides. This study showed the potential use of THPI, PI and phthalic acid as key biomarkers of exposure to captan and folpet.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The time courses of key biomarkers of exposure to captan and folpet was assessed in accessible biological matrices of orally exposed volunteers. Ten volunteers ingested 1 mg kg(-1) body weight of captan or folpet. Blood samples were withdrawn at fixed time periods over the 72 h following ingestion and complete urine voids were collected over 96 h post-dosing. The tetrahydrophthalimide (THPI) metabolite of captan along with the phthalimide (PI) and phthalic acid metabolites of folpet were then quantified in these samples. Plasma levels of THPI and PI increased progressively after ingestion, reaching peak values ~10 and 6 h post-dosing, respectively; subsequent elimination phase appeared monophasic with a mean elimination half-life (t(½) ) of 15.7 and 31.5 h, respectively. In urine, elimination rate time courses of PI and phthalic acid evolved in parallel, with respective t(½) of 27.3 and 27.6 h; relatively faster elimination was found for THPI, with mean t(½) of 11.7 h. However, phthalic acid was present in urine in 1000-fold higher amounts than PI. In the 96 h period post-treatment, on average 25% of folpet dose was excreted in urine as phthalic acid as compared with only 0.02% as PI. The corresponding value for THPI was 3.5%. Overall, THPI and PI appear as interesting biomarkers of recent exposure, with relatively short half-lives; their sensitivity to assess exposure in field studies should be further verified. Although not a metabolite specific to folpet, the concomitant use of phthalic acid as a major biomarker of exposure to folpet should also be considered. Copyright © 2011 John Wiley & Sons, Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Prognostic models have been developed to predict survival of patients with newly diagnosed glioblastoma (GBM). To improve predictions, models should be updated with information at the recurrence. We performed a pooled analysis of European Organization for Research and Treatment of Cancer (EORTC) trials on recurrent glioblastoma to validate existing clinical prognostic factors, identify new markers, and derive new predictions for overall survival (OS) and progression free survival (PFS).¦METHODS: Data from 300 patients with recurrent GBM recruited in eight phase I or II trials conducted by the EORTC Brain Tumour Group were used to evaluate patient's age, sex, World Health Organisation (WHO) performance status (PS), presence of neurological deficits, disease history, use of steroids or anti-epileptics and disease characteristics to predict PFS and OS. Prognostic calculators were developed in patients initially treated by chemoradiation with temozolomide.¦RESULTS: Poor PS and more than one target lesion had a significant negative prognostic impact for both PFS and OS. Patients with large tumours measured by the maximum diameter of the largest lesion (⩾42mm) and treated with steroids at baseline had shorter OS. Tumours with predominant frontal location had better survival. Age and sex did not show independent prognostic values for PFS or OS.¦CONCLUSIONS: This analysis confirms performance status but not age as a major prognostic factor for PFS and OS in recurrent GBM. Patients with multiple and large lesions have an increased risk of death. With these data prognostic calculators with confidence intervals for both medians and fixed time probabilities of survival were derived.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background and Aims: Two distinct e ndoscopic phenotypes of E osinophilic Esophagitis (EoE) h ave been identified: t he inflammatory (IP) a nd the stenosing (SP) p henotype. I t is not known whether these EoE-associated phenotypes are reflective of different phases during disease course. We aimed to assess the phenotype a t initial EoE p resentation and d iagnosis and to evaluate if SP increases over time. Methods: R etrospective a nalysis of t he Swiss EoE Database (SEED) extended b y a review of p atients charts, endoscopy and pathology records. Results: F orty-four E oE p atients were a nalyzed (33 males, mean age at index visit 41 ± 14 years, all Caucasians). Median follow-up t ime was 3.1 years (IQR 1-4, r ange 1 -18 years). Median diagnostic delay w as 5 y ears (IQR 2-16, range 0-34 years). A t first diagnosis, 3 2% ( 14/44) o f EoE patients h ad already presented w ith a stenosis. T he mean d iameter o f the stenoses w as 1 0 ± 2 mm, and the mean length was 2 .8 ± 2 .9 cm. Peak e osinophil count d id n ot c hange over t ime (48 ± 39 eos/HPF at index visit vs. 59 ± 41 eos/HPF at end of follow-up, n=44). The risk of the presence of a stenosis at index visit was 0% f or a d isease duration of 0 -4 y ears, 37% f or a d isease duration between 5-10 years and 67% f or a d isease duration >10 years (p = 0.0035, trend test). Conclusions: T he frequency of e sophageal stenoses i s proportional to the disease duration, whereas the inflammatory activity does n ot s ignificantly c hange over t ime. O ur f indings underscore the necessity to reduce diagnostic delay in EoE and to control the underlying inflammatory processes to prevent esophageal remodeling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

SOUND OBJECTS IN TIME, SPACE AND ACTIONThe term "sound object" describes an auditory experience that is associated with an acoustic event produced by a sound source. At cortical level, sound objects are represented by temporo-spatial activity patterns within distributed neural networks. This investigation concerns temporal, spatial and action aspects as assessed in normal subjects using electrical imaging or measurement of motor activity induced by transcranial magnetic stimulation (TMS).Hearing the same sound again has been shown to facilitate behavioral responses (repetition priming) and to modulate neural activity (repetition suppression). In natural settings the same source is often heard again and again, with variations in spectro-temporal and spatial characteristics. I have investigated how such repeats influence response times in a living vs. non-living categorization task and the associated spatio-temporal patterns of brain activity in humans. Dynamic analysis of distributed source estimations revealed differential sound object representations within the auditory cortex as a function of the temporal history of exposure to these objects. Often heard sounds are coded by a modulation in a bilateral network. Recently heard sounds, independently of the number of previous exposures, are coded by a modulation of a left-sided network.With sound objects which carry spatial information, I have investigated how spatial aspects of the repeats influence neural representations. Dynamics analyses of distributed source estimations revealed an ultra rapid discrimination of sound objects which are characterized by spatial cues. This discrimination involved two temporo-spatially distinct cortical representations, one associated with position-independent and the other with position-linked representations within the auditory ventral/what stream.Action-related sounds were shown to increase the excitability of motoneurons within the primary motor cortex, possibly via an input from the mirror neuron system. The role of motor representations remains unclear. I have investigated repetition priming-induced plasticity of the motor representations of action sounds with the measurement of motor activity induced by TMS pulses applied on the hand motor cortex. TMS delivered to the hand area within the primary motor cortex yielded larger magnetic evoked potentials (MEPs) while the subject was listening to sounds associated with manual than non- manual actions. Repetition suppression was observed at motoneuron level, since during a repeated exposure to the same manual action sound the MEPs were smaller. I discuss these results in terms of specialized neural network involved in sound processing, which is characterized by repetition-induced plasticity.Thus, neural networks which underlie sound object representations are characterized by modulations which keep track of the temporal and spatial history of the sound and, in case of action related sounds, also of the way in which the sound is produced.LES OBJETS SONORES AU TRAVERS DU TEMPS, DE L'ESPACE ET DES ACTIONSLe terme "objet sonore" décrit une expérience auditive associée avec un événement acoustique produit par une source sonore. Au niveau cortical, les objets sonores sont représentés par des patterns d'activités dans des réseaux neuronaux distribués. Ce travail traite les aspects temporels, spatiaux et liés aux actions, évalués à l'aide de l'imagerie électrique ou par des mesures de l'activité motrice induite par stimulation magnétique trans-crânienne (SMT) chez des sujets sains. Entendre le même son de façon répétitive facilite la réponse comportementale (amorçage de répétition) et module l'activité neuronale (suppression liée à la répétition). Dans un cadre naturel, la même source est souvent entendue plusieurs fois, avec des variations spectro-temporelles et de ses caractéristiques spatiales. J'ai étudié la façon dont ces répétitions influencent le temps de réponse lors d'une tâche de catégorisation vivant vs. non-vivant, et les patterns d'activité cérébrale qui lui sont associés. Des analyses dynamiques d'estimations de sources ont révélé des représentations différenciées des objets sonores au niveau du cortex auditif en fonction de l'historique d'exposition à ces objets. Les sons souvent entendus sont codés par des modulations d'un réseau bilatéral. Les sons récemment entendus sont codé par des modulations d'un réseau du côté gauche, indépendamment du nombre d'expositions. Avec des objets sonores véhiculant de l'information spatiale, j'ai étudié la façon dont les aspects spatiaux des sons répétés influencent les représentations neuronales. Des analyses dynamiques d'estimations de sources ont révélé une discrimination ultra rapide des objets sonores caractérisés par des indices spatiaux. Cette discrimination implique deux représentations corticales temporellement et spatialement distinctes, l'une associée à des représentations indépendantes de la position et l'autre à des représentations liées à la position. Ces représentations sont localisées dans la voie auditive ventrale du "quoi".Des sons d'actions augmentent l'excitabilité des motoneurones dans le cortex moteur primaire, possiblement par une afférence du system des neurones miroir. Le rôle des représentations motrices des sons d'actions reste peu clair. J'ai étudié la plasticité des représentations motrices induites par l'amorçage de répétition à l'aide de mesures de potentiels moteurs évoqués (PMEs) induits par des pulsations de SMT sur le cortex moteur de la main. La SMT appliquée sur le cortex moteur primaire de la main produit de plus grands PMEs alors que les sujets écoutent des sons associée à des actions manuelles en comparaison avec des sons d'actions non manuelles. Une suppression liée à la répétition a été observée au niveau des motoneurones, étant donné que lors de l'exposition répétée au son de la même action manuelle les PMEs étaient plus petits. Ces résultats sont discuté en termes de réseaux neuronaux spécialisés impliqués dans le traitement des sons et caractérisés par de la plasticité induite par la répétition. Ainsi, les réseaux neuronaux qui sous-tendent les représentations des objets sonores sont caractérisés par des modulations qui gardent une trace de l'histoire temporelle et spatiale du son ainsi que de la manière dont le son a été produit, en cas de sons d'actions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT This dissertation investigates the, nature of space-time as described by the theory of general relativity. It mainly argues that space-time can be naturally interpreted as a physical structure in the precise sense of a network of concrete space-time relations among concrete space-time points that do not possess any intrinsic properties and any intrinsic identity. Such an interpretation is fundamentally based on two related key features of general relativity, namely substantive general covariance and background independence, where substantive general covariance is understood as a gauge-theoretic invariance under active diffeomorphisms and background independence is understood in the sense that the metric (or gravitational) field is dynamical and that, strictly speaking, it cannot be uniquely split into a purely gravitational part and a fixed purely inertial part or background. More broadly, a precise notion of (physical) structure is developed within the framework of a moderate version of structural realism understood as a metaphysical claim about what there is in the world. So, the developement of this moderate structural realism pursues two main aims. The first is purely metaphysical, the aim being to develop a coherent metaphysics of structures and of objects (particular attention is paid to the questions of identity and individuality of these latter within this structural realist framework). The second is to argue that moderate structural realism provides a convincing interpretation of the world as described by fundamental physics and in particular of space-time as described by general relativity. This structuralist interpretation of space-time is discussed within the traditional substantivalist-relationalist debate, which is best understood within the broader framework of the question about the relationship between space-time on the one hand and matter on the other. In particular, it is claimed that space-time structuralism does not constitute a 'tertium quid' in the traditional debate. Some new light on the question of the nature of space-time may be shed from the fundamental foundational issue of space-time singularities. Their possible 'non-local' (or global) feature is discussed in some detail and it is argued that a broad structuralist conception of space-time may provide a physically meaningful understanding of space-time singularities, which is not plagued by the conceptual difficulties of the usual atomsitic framework. Indeed, part of these difficulties may come from the standard differential geometric description of space-time, which encodes to some extent this atomistic framework; it raises the question of the importance of the mathematical formalism for the interpretation of space-time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stiffness tomography is a new atomic force microscopy imaging technique that allows highlighting structures located underneath the surface of the sample. In this imaging mode, such structures are identified by investigating their mechanical properties. We present here, for the first time, a description of the use of this technique to acquire detailed stiffness maps of fixed and living macrophages. Indeed, the mechanical properties of several macrophages were studied through stiffness tomography imaging, allowing some insight of the structures lying below the cell's surface. Through these investigations, we were able to evidence the presence and properties of stiff column-like features located underneath the cell membrane. To our knowledge, this is the first evidence of the presence, underneath the cell membrane, of such stiff features, which are in dimension and form compatible with phagosomes. Moreover, by exposing the cells to cytochalasin, we were able to study the induced modifications, obtaining an indication of the location and mechanical properties of the actin cytoskeleton. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose Cadaveric study at our institution has demonstrated that optimal basaplate fixation of a reversed shoulder arthroplasty (RSA) could be achieved with screws in three major columns. Our aim was to review our early rate of aseptic glenoid loosening in a series of baseplate fixed according to this principle. Material and Methods Between 2005 and 2008, 48 RSA (Aequalis Reversed) were implanted in 48 patients with an average age of 74.4 years (range, 56 to 86 years). There were 37 women and 11 men. Twenty-seven primary RSAs were performed for cuff tear arthropathy, 3 after failed rotator cuff surgery, 6 for failed arthroplasties, 7 for acute fractures and 5 after failed ORIF. All baseplate fixation were done using a nonlocking posterior screw in the spine, a nonlocking anterior screw in the glenoid body, a locking superior screw in the coracoid and a locking inferior screw in the pillar. All patients were reviewed with standardized radiographs. The number of screws were reported. We measured the position of the screws in relation to the scapular spine and the coracoid process in two different views. We defined screw positions as totally, partially or out of the target. Finally we reported glenoid aseptic loosening which was defined as implant subsidence. Results Four patients were lost to follow-up. Thus, 44 shoulders could be reviewed after a mean follow-up of 13 months (range, 6 to 32 months). All baseplates were fixed with 4 screws. Thirty-seven (84%) screws were either partially or totally in the spine. Thus, 7 (16%) scapular spine screws were out of the target. No coracoid screw was out the target. Two (4.5%) patients had glenoid loosening. Both had a scapular spine and a coracoid screw partially in the bone. Conclusion Early aseptic glenoid loosening occurred before the two years follow-up and is most of time related to technical problems and/or insufficient bone stock and bone quality. Our study demonstrate that baseplate fixation according to the three columns principle is a reproducible technique and a valuable way to prevent early glenoid loosening.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Glenoid bone volume and bone quality can render the fixation of a reversed shoulder arthroplasty (RSA) basis plate hazardous. Cadaveric study at our institution has demonstrated that optimal baseplate fixation could be achieved with screws in three major columns. Our aim is to review our early rate of aseptic glenoid loosening in a series of baseplates fixed according to this principle. Methods: Between 2005 and 2008, 48 consecutive RSA (Reversed Aequalis) were implanted in 48 patients with an average age of 74.4 years (range, 56 to 86 years). There were 37 women and 11 men. Twenty-seven primary RSAs were performed for cuff tear arthropathy, 3 after failed rotator cuff surgery, 6 for failed arthroplasties, 7 for acute fractures and 5 after failed ORIF. All baseplate fixations were done using a nonlocking posterior screw in the scapular spine, a nonlocking anterior screw in the glenoid body, a locking superior screw in the coracoid and a locking inferior screw in the pillar. All patients were reviewed with standardized radiographs. We reported the positions of the screws in relation to the scapular spine and the coracoid process in two different views. We defined screw positions as totally, partially or out of the target. Finally, we reported aseptic glenoid loosening which was defined as implant subsidence. Results: Four patients were lost to follow-up. Thus 44 shoulders could be reviewed after a mean follow-up of 16 months (range, 9 to 32 months). Thirty-seven (84%) screws were either partially or totally in the spine. Thus, 7 (16%) scapular spine screws were out of the target. No coracoid screw was out of the target. At final follow-up control, we reported no glenoid loosening. Conclusion: Early glenoid loosening occurred before the two years follow-up and is most of time related to technical problems and/or insufficient glenoid bone stock and bone quality. Our study demonstrate that baseplate fixation of a RSA according to the three columns principle is a reproducible technique and a valuable way to prevent early glenoid loosening.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Epigenetic silencing of the DNA repair protein O(6)-methylguanine-DNA methyltransferase (MGMT) by promoter methylation predicts successful alkylating agent therapy, such as with temozolomide, in glioblastoma patients. Stratified therapy assignment of patients in prospective clinical trials according to tumor MGMT status requires a standardized diagnostic test, suitable for high-throughput analysis of small amounts of formalin-fixed, paraffin-embedded tumor tissue. A direct, real-time methylation-specific PCR (MSP) assay was developed to determine methylation status of the MGMT gene promoter. Assay specificity was obtained by selective amplification of methylated DNA sequences of sodium bisulfite-modified DNA. The copy number of the methylated MGMT promoter, normalized to the beta-actin gene, provides a quantitative test result. We analyzed 134 clinical glioma samples, comparing the new test with the previously validated nested gel-based MSP assay, which yields a binary readout. A cut-off value for the MGMT methylation status was suggested by fitting a bimodal normal mixture model to the real-time results, supporting the hypothesis that there are two distinct populations within the test samples. Comparison of the tests showed high concordance of the results (82/91 [90%]; Cohen's kappa = 0.80; 95% confidence interval, 0.82-0.95). The direct, real-time MSP assay was highly reproducible (Pearson correlation 0.996) and showed valid test results for 93% (125/134) of samples compared with 75% (94/125) for the nested, gel-based MSP assay. This high-throughput test provides an important pharmacogenomic tool for individualized management of alkylating agent chemotherapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compared the outcome of total knee replacement (TKR) in adult patients with fixed- and mobile-bearing prostheses during the first post-operative year and at five years' follow-up, using gait parameters as a new objective measure. This double-blind randomised controlled clinical trial included 55 patients with mobile-bearing (n = 26) and fixed-bearing (n = 29) prostheses of the same design, evaluated pre-operatively and post-operatively at six weeks, three months, six months, one year and five years. Each participant undertook two walking trials of 30 m and completed the EuroQol questionnaire, Western Ontario and McMaster Universities osteoarthritis index, Knee Society score, and visual analogue scales for pain and stiffness. Gait analysis was performed using five miniature angular rate sensors mounted on the trunk (sacrum), each thigh and calf. The study population was divided into two groups according to age (≤ 70 years versus > 70 years). Improvements in most gait parameters at five years' follow-up were greater for fixed-bearing TKRs in older patients (> 70 years), and greater for mobile-bearing TKRs in younger patients (≤ 70 years). These findings should be confirmed by an extended age controlled study, as the ideal choice of prosthesis might depend on the age of the patient at the time of surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The long-term outcome of antiretroviral therapy (ART) is not assessed in controlled trials. We aimed to analyse trends in the population effectiveness of ART in the Swiss HIV Cohort Study over the last decade. METHODS: We analysed the odds of stably suppressed viral load (ssVL: three consecutive values <50 HIV-1 RNA copies/mL) and of CD4 cell count exceeding 500 cells/μL for each year between 2000 and 2008 in three scenarios: an open cohort; a closed cohort ignoring the influx of new participants after 2000; and a worst-case closed cohort retaining lost or dead patients as virological failures in subsequent years. We used generalized estimating equations with sex, age, risk, non-White ethnicity and era of starting combination ART (cART) as fixed co-factors. Time-updated co-factors included type of ART regimen, number of new drugs and adherence to therapy. RESULTS: The open cohort included 9802 individuals (median age 38 years; 31% female). From 2000 to 2008, the proportion of participants with ssVL increased from 37 to 64% [adjusted odds ratio (OR) per year 1.16 (95% CI 1.15-1.17)] and the proportion with CD4 count >500 cells/μL increased from 40 to >50% [OR 1.07 (95% CI 1.06-1.07)]. Similar trends were seen in the two closed cohorts. Adjustment did not substantially affect time trends. CONCLUSIONS: There was no relevant dilution effect through new participants entering the open clinical cohort, and the increase in virological/immunological success over time was not an artefact of the study design of open cohorts. This can partly be explained by new treatment options and other improvements in medical care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reproductive success is determined by the presence and timing of encounter of mates. The latter depends on species-specific reproductive characteristics (e.g. initiation/duration of the mating window), season, and reproductive strategies (e.g. intensity of choosiness) that may potentially mitigate constraints imposed by mating windows. Despite their potentially crucial role for fitness and population dynamics, limited evidence exists about mating window initiation, duration and reproductive strategies. Here, we experimentally tested the mechanisms of initiation and the duration of the common lizard's Zootoca vivipara mating window, by manipulating the timing of mate encounter and analyzing its effect on (re-)mating probability. We furthermore tested treatment effects on female reproductive strategies, by measuring female choosiness. The timing of mate encounter and season did not significantly affect mating probability. However, a longer delay until mate encounter reduced female choosiness. Re-mating probability decreased with re-mating delay and was independent of mating delay. This indicates that mating window initiation depends on mate encounter, that its duration is fixed, and that plastic reproductive strategies exist. These findings contrast with previous beliefs and shows that mating windows per se may not necessarily constrain reproductive success, which is congruent with rapid range expansion and absence of positive density-effects on reproductive success (Allee effects). In summary, our results show that predicting the effect of mating windows on reproduction is complex and that experimental evidence is essential for evaluating their effect on reproduction and reproductive strategies, both being important determinants of population dynamics and the colonization of new habitats.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: In alpine skiing, chronometry analysis is currently the most common tool to assess performance. It is widely used to rank competitors during races, as well as to manage athletes training and to evaluate material. Usually, this measurement is accurately realized using timing cells. Nevertheless, these devices are too complex and expensive to allow chronometry of every gates crossing. On the other side, differential GPS can be used for measuring gate crossing time (Waegli et al). However, this is complex (e.g. recording gate position with GPS) and mainly used in research applications. The aim of the study was to propose a wearable system to time gates crossing during alpine skiing slalom (SL), which is suitable for routine uses. METHODS: The proposed system was composed of a 3D accelerometer (ADXL320®, Analog Device, USA) placed at the sacrum of the athlete, a matrix of force sensors (Flexiforce®, Tekscan, USA) fixed on the right shin guard and a data logger (Physilog®, BioAGM, Switzerland). The sensors were sampled at 500 Hz. The crossing time were calculated in two phases. First, the accelerometer was used to detect the curves by considering the maximum of the mediolateral peak acceleration. Then, the force sensors were used to detect the impacts with the gates by considering maximum force variation. In case of non impact, the detection was realized based on the acceleration and features measured at the other gates. In order to assess the efficiency of the system, two different SL were monitored twice for two world cup level skiers, a male SL expert and a female downhill expert. RESULTS AND DISCUSSION: The combination of the accelerometer and force sensors allowed to clearly identify the gate crossing times. When comparing the runs of the SL expert and the downhill expert, we noticed that the SL expert was faster. For example for the first SL, the overall difference between the best run of each athlete was of 5.47s. At each gate, the SL expert increased the time difference slower at the beginning (0.27s/gate) than at the end (0.34s/gate). Furthermore, when comparing the runs of the SL expert, a maximum time difference of 20ms at each gate was noticed. This showed high repeatability skills of the SL expert. In opposite, the downhill expert with a maximum difference time of 1s at each gate was clearly less repeatable. Both skiers were not disturbed by the system. CONCLUSION: This study proposed a new wearable system to automatically time gates crossing during alpine skiing slalom combining force and accelerometer sensors. The system was evaluated with two professional world cup skiers and showed a high potential. This system could be extended to time other parameters. REFERENCES Waegli A, Skaloud J (2007). Inside GNSS, Spring, 24-34.