4 resultados para facts devices
em Université de Lausanne, Switzerland
Resumo:
Background: Switzerland was the first country to approve certolizumab pegol (Cimzia, CZP) for the treatment of patients with moderate to severe Crohn's disease (CD) in September 2007. This phase IV study aimed to evaluate the efficacy and safety of CZP in a Swiss multicenter cohort of practice-based patients. Methods: Baseline and Week 6 evaluation questionnaires were sent to all Swiss gastroenterologists in hospitals and private practices. Disease activity was assessed with the Harvey-Bradshaw Index (HBI) and adverse events were evaluated according to WHO guidelines. Results: Fifty patients (31 women, 19 men) were included; 56% had complicated disease (stricture or fistula) and 52% had undergone prior CD-related surgery. All patients. had prior exposure to systemic steroids, 96% to immunomodulators, 78% to infliximab, and 50% to adalimumab. A significant decrease in HBI was observed at Week 6 (versus Week 0) following induction therapy with CZP 400 mg subcutaneously at Weeks 0, 2, and 4 (12.6 +/- 4.7 Week 0 versus 6.2 +/- 4.4 Week 6, P < 0.001). Response and remission rates at Week 6 were 54% and 40%, respectively. We identified 8/11 CD patients undergoing a 50% fistula response (P = 0.021). The frequency of adverse drug reactions attributed to CZP was 6%. CZP was continued in 80% of patients beyond Week 6. Conclusions: In a population of CD patients with complicated disease behavior, CZP induced a response and remission in 54% and 40% of patients, respectively. This series provides the first evidence of the effectiveness of CZP in perianal fistulizing CD.
Resumo:
The majority of transcatheter aortic valve implantations, structural heart procedures and the newly developed transcatheter mitral valve repair and replacement are traditionally performed either through a transfemoral or a transapical access site, depending on the presence of severe peripheral vascular disease or anatomic limitations. The transapical approach, which carries specific advantages related to its antegrade nature and the short distance between the introduction site and the cardiac target, is traditionally performed through a left anterolateral mini-thoracotomy and requires rib retractors, soft tissue retractors and reinforced apical sutures to secure, at first, the left ventricular apex for the introduction of the stent-valve delivery systems and then to seal the access site at the end of the procedure. However, despite the advent of low-profile apical sheaths and newly designed delivery systems, the apical approach represents a challenge for the surgeon, as it has the risk of apical tear, life-threatening apical bleeding, myocardial damage, coronary damage and infections. Last but not least, the use of large-calibre stent-valve delivery systems and devices through standard mini-thoracotomies compromises any attempt to perform transapical transcatheter structural heart procedures entirely percutaneously, as happens with the transfemoral access site, or via a thoracoscopic or a miniaturised video-assisted percutaneous technique. During the past few years, prototypes of apical access and closure devices for transapical heart valve procedures have been developed and tested to make this standardised successful procedure easier. Some of them represent an important step towards the development of truly percutaneous transcatheter transapical heart valve procedures in the clinical setting.