6 resultados para elastomer composites

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les résultats des recherches contemporaines, montrant notamment l'importance du raisonnement fluide, de la mémoire de travail (IMT) et de la vitesse de traitement (IVT) dans le fonctionnement cognitif, ont conduit les concepteurs de la WAIS-IV à introduire de nouvelles épreuves pour renforcer l'évaluation de ces dimensions cognitives. L'interprétation des scores de la WAIS-IV repose maintenant sur quatre indices factoriels (ICV, IRP, IMT et IVT), ainsi que sur le QIT. Les concepteurs de la WAIS-IV indiquent que l'un des objectifs de la révision consistait à actualiser les fondements théoriques de cette échelle. Pourtant, la structure globale de la WAIS-IV ne correspond que partiellement à celle proposée dans le modèle qui fait consensus aujourd'hui, le modèle de Cattell-Horn-Carroll (CHC). Par exemple, la WAIS-IV ne propose pas d'indice de raisonnement fluide, bien que les constructeurs soulignent l'importance de cette dimension dans le fonctionnement cognitif. Dans cet article, nous proposons, pour la WAIS-IV, les normes francophones de cinq scores composites CHC, à savoir le raisonnement fluide (Gf), compréhension-connaissances (Gc), le traitement visuel (Gv), la mémoire à court terme (Gsm), et l'IVT (Gs). Ces normes ont été établies en utilisant une procédure d'approximation statistique. À l'instar des scores CHC que nous avons proposés pour le WISCIV, ces normes pour la WAIS-IV permettent aux cliniciens de basculer vers une grille d'interprétation basée sur le modèle dominant et d'utiliser les cinq scores composites CHC en complément des quatre indices standard dans le cadre d'analyses normatives et ipsatives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bien que le manuel du WISC-IV fasse référence à la théorie de Cattell-Horn-Carroll (CHC), les indices calculés à partir de cette batterie (ICV, IRP, IMT et IVT) n'ont pas été définis sur la base du modèle CHC. Afin d'apporter un éclairage complémentaire sur les performances observées, nous recommandons néanmoins d'examiner les scores des subtests du WISC-IV en référence à la nomenclature des aptitudes cognitives proposées dans le modèle CHC. La première partie de cet article présente les normes francophones pour cinq facteurs CHC du WISC-IV, à savoir le raisonnement fluide (Gf), compréhension-connaissances (Gc), le traitement visuel (Gv), la mémoire à court terme (Gsm) et la vitesse de traitement (Gs), établies en utilisant une procédure d'approximation statistique. La seconde partie présente l'examen de la validité de ces normes, confrontées à des données recueillies sur un échantillon de 250 enfants. Nos résultats montrent que les corrélations entre les indices classiques du WISC-IV (ICV, IRP, IMT et IVT) et les scores composites CHC sont élevées, attestant de la validité des scores CHC. Ces normes permettent de calculer et d'utiliser les scores composites CHC en complément des indices standard, dans le cadre d'analyses normatives et ipsatives.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: We examined the correlation between clinical wear rates of restorative materials and enamel (TRAC Research Foundation, Provo, USA) and the results of six laboratory test methods (ACTA, Alabama (generalized, localized), Ivoclar (vertical, volumetric), Munich, OHSU (abrasion, attrition), Zurich). METHODS: Individual clinical wear data were available from clinical trials that were conducted by TRAC Research Foundation (formerly CRA) together with general practitioners. For each of the n=28 materials (21 composite resins for intra-coronal restorations [20 direct and 1 indirect], 5 resin materials for crowns, 1 amalgam, enamel) a minimum of 30 restorations had been placed in posterior teeth, mainly molars. The recall intervals were up to 5 years with the majority of materials (n=27) being monitored, however, only for up to 2 years. For the laboratory data, the databases MEDLINE and IADR abstracts were searched for wear data on materials which were also clinically tested by TRAC Research Foundation. Only those data for which the same test parameters (e.g. number of cycles, loading force, type of antagonist) had been published were included in the study. A different quantity of data was available for each laboratory method: Ivoclar (n=22), Zurich (n=20), Alabama (n=17), OHSU and ACTA (n=12), Munich (n=7). The clinical results were summed up in an index and a linear mixed model was fitted to the log wear measurements including the following factors: material, time (0.5, 1, 2 and 3 years), tooth (premolar/molar) and gender (male/female) as fixed effects, and patient as random effect. Relative ranks were created for each material and method; the same was performed with the clinical results. RESULTS: The mean age of the subjects was 40 (±12) years. The materials had been mostly applied in molars (81%) and 95% of the intracoronal restorations were Class II restorations. The mean number of individual wear data per material was 25 (range 14-42). The mean coefficient of variation of clinical wear data was 53%. The only significant correlation was reached by OHSU (abrasion) with a Spearman r of 0.86 (p=0.001). Zurich, ACTA, Alabama generalized wear and Ivoclar (volume) had correlation coefficients between 0.3 and 0.4. For Zurich, Alabama generalized wear and Munich, the correlation coefficient improved if only composites for direct use were taken into consideration. The combination of different laboratory methods did not significantly improve the correlation. SIGNIFICANCE: The clinical wear of composite resins is mainly dependent on differences between patients and less on the differences between materials. Laboratory methods to test conventional resins for wear are therefore less important, especially since most of them do not reflect the clinical wear.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Does Weber's notion of salvation goods, along with the connected one of the religious market, apply to the modern history of yoga? The case study chosen here (the yoga of Pattabhi Jois) clearly shows that these notions highlight many aspects of the expansion of yoga into a global market product. However, the notion of salvation goods resists the new hermeneutical situation of encounter and has to be adapted to the present situation of religious "patchwork". The notion of religious market lacks depth to describe the various understandings and appropriations of yoga in precise historical situations. Other aspects of the current global status of yoga may be highlighted by applying the concept of pilgrimage. La notion de bien de salut que nous lègue Max Weber et la notion de marché religieux qui en découle peuvent-elles s'appliquer à l'histoire moderne du yoga? L'étude de cas que nous consacrons au yoga de Pattabhi Jois montre que ces notions éclairent bien certains aspects de l'expansion du yoga en tant que produit d'un marché globalisé. Cependant la notion de bien de salut résiste à une réflexion de type herméneutique sur les processus de rencontres et doit être adaptée à la situation contemporaine, ou` les religions se présentent comme des ensembles composites. La notion de marché religieux ne permet pas d'expliquer les diverses compréhensions et appropriations du yoga dans des situations historiques précises. D'autres aspects de la situation du yoga sont mieux explicités si on prend le concept de pèlerinage comme point de référence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To carry out a meta-analysis in order to assess the influencing factors on retention loss and marginal discoloration of cervical restorations made of composites and glass ionomer (derivates). METHODS: The literature was searched for prospective clinical studies on cervical restorations with an observation period of at least 18 months. RESULTS: Fifty clinical studies involving 40 adhesive systems matched the inclusion criteria. On average, 10% of the cervical fillings were lost and 24% exhibited marginal discoloration after 3 years. The variability ranged from 0% to 50% for retention loss and from 0% to 74% for marginal discoloration. Hardly any secondary caries was detected. When linear mixed models with a study and experiment effect were used, the analysis revealed that the adhesive/restorative class had the most significant influence, with 2-step self-etching adhesive systems performing best and 1-step self-etching adhesive systems performing worst; 3-step etch-and-rinse systems, glass ionomers/resin-modified glass ionomers, 2-step etch-and-rinse systems and polyacid-modified resin composites were ranked in between. Restorations placed in teeth whose dentin/enamel had been prepared/roughened showed a statistically significant higher retention rate than those placed in teeth with unprepared dentin (p<0.05). Beveling of the enamel and the type of isolation used (rubberdam/cotton rolls) had no significant influence. SIGNIFICANCE: The clinical performance of cervical restorations is significantly influenced by the type of adhesive system used and/or the adhesive class to which the system belonged and whether the dentin/enamel is prepared or not. 2-Step self-etching- and 3-step etch&rinse systems shall be chosen over 1-step self-etching systems and glass ionomer derivates. The dentin (and enamel) surface shall be roughened before placement of the restoration.