35 resultados para easy reading

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Emergency room reading performances have been a point of interest in recent studies comparing radiologists to other physician groups. Our objective was to evaluate and compare the reading performances of radiologists and surgeons in an emergency room setting of non-traumatic abdominal CTs. Methods and materials: A total of ten readers representing four groups participated in this study: three senior radiologists and visceral surgeons, respectively, and two junior radiologists and surgeons, respectively. Each observer blindedly evaluated a total of 150 multi-slice acute abdominal CTs. CTs were chosen representing established proportions of acute abdomen pathologies in a Level I trauma centre from 2003 to 2005. Each answer was interpretated as right or wrong regarding pathology location, diagnosis and need for operation. Gold standard was the intraoperative result, and the clinical patient follow-up for non-operated patients. Significance was assumed at a p <.05 level. Results: Senior radiologists had a mean score of 2.38 ± 1.14, junior radiologists a score of 2.34 ± 1.14, whereas senior surgeons scored 2.07 ± 1.30 and junior surgeons 1.62 ± 1.42. No significant difference was found between the two radiologist groups, but results were significantly better for senior surgeons as compared to junior surgeons and better for the two radiologist groups as compared to each of the surgeon groups (all p <.05). Conclusion: Abdominal CT reading in an acute abdomen setting should continue to rely on an evaluation by a radiologist, whether senior or junior. Satisfying reading results can be achieved by senior visceral surgeons, but junior surgeons need more experience for a good reading performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Minor lymphocyte stimulating (Mls) antigens specifically stimulate T cell responses that are restricted to particular T cell receptor (TCR) beta chain variable domains. The Mls phenotype is genetically controlled by an open reading frame (orf) located in the 3' long terminal repeat of mouse mammary tumor virus (MMTV); however, the mechanism of action of the orf gene product is unknown. Whereas predicted orf amino acid sequences show strong overall homology, the 20-30 COOH-terminal residues are strikingly polymorphic. This polymorphic region correlates with TCR V beta specificity. We have generated monoclonal antibodies to a synthetic peptide encompassing the 19 COOH-terminal amino acid residues of Mtv-7 orf, which encodes the Mls-1a determinant. We show here that these antibodies block Mls responses in vitro and can interfere specifically with thymic clonal deletion of Mls-1a reactive V beta 6+ T cells in neonatal mice. Furthermore, the antibodies can inhibit V beta 6+ T cell responses in vivo to an infectious MMTV that shares orf sequence homology and TCR specificity with Mtv-7. These results confirm the predicted extracellular localization of the orf COOH terminus and imply that the orf proteins of both endogenous and exogenous MMTV interact directly with TCR V beta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To create an instrument to be used in an outpatient clinic to detect adolescents prone to risk-taking behaviours. Based on previous research, five identified variables (relationship with parents and teachers, liking going to school, average grades, and level of religiosity) were used to create a screening tool to detect at least one of ten risky behaviours (tobacco, alcohol, cannabis and other illegal drugs use; sexual intercourse and sexual risky behaviour; driving while intoxicated, riding with an intoxicated driver, not always using a seat belt, and not always using a helmet). The instrument was tested using the Barcelona Adolescent Health Survey 1993. A Receiver Operating Characteristics curve was used to find the best cut-off point between high and low risk score. Odds ratios and 95% confidence intervals were calculated to detect at least one risky behaviour and for each individual behaviour. In order to assess its predictive value, the analysis was repeated using the Barcelona Adolescent Health Survey 1999. In both cases, analyses were conducted for the whole sample and for younger and older adolescents. Adolescents with a high-risk score were more likely to take at least one risky behaviour both when the whole sample was analysed and by age groups. With very few exceptions, the Behaviour Evaluation for Risk-Taking Adolescents showed significant odds ratios for each individual variable. CONCLUSION: The Behaviour Evaluation for Risk-Taking Adolescents has shown its potential as an easy to use instrument to screen for risk-taking behaviours. Future research must aim towards assessing this instrument's predictive value in the clinical setting and it's application to other populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The European Guidelines specify a minimum of 5,000 screening cases to be read yearly by radiologists carrying out second reading in non-centralized programs. This professional requirement is difficult to reach and/or to implement in regional programs covering a sparse population with a high number of participating radiology units, so that alternative blind double reading strategies must be devised. OBJECTIVE: To evaluate the effect on breast cancer screening performances of two second reading strategies used in non-centralized, low-volume programs. METHODS: Reading performances in two Swiss regional breast cancer screening programs (cantons of Wallis and Vaud), covering female populations, aged 50-69, of about 31'000 and 72'000 inhabitants were computed and compared. Both programs had similar screening regimens and organizations, but differed with respect to second reading. One setting applied a selective strategy whereby only experienced radiologists performed second reading; the other elicited not to restrict second readers on the basis of their individual screening activity. Analysis included some 140,000 mammograms performed between 1999 and 2005. RESULTS: Overall, screening performances improved with increasing total volume of reading, albeit not in a linear fashion. Regardless of setting, radiologists attained a higher level of screening accuracy when performing second rather than first readings, and incident rather than prevalent screening cases. The effect of a selective, small group of second readers appeared to impact favorably on the false-positive rate and other indicators of screening quality. As the learning curve depends on the number of mammograms read, these distinct strategies may bear different outcome in the long run. Implications and practical issues for low-volume programs are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Temporal arteritis is a very serious form of vasculitis. Early treatment is essential to avoid blindness. Surgical biopsy of the temporal artery is the gold standard for the diagnosis, but facial nerve injuries may occur. OBJECTIVE: To describe a simple and safe procedure for temporal artery biopsy. METHODS: Case report. RESULTS: A 62-year-old-woman with presumed temporal arteritis was referred. Precise localization of temporal arteries and its branches was obtained with color duplex ultrasonography. Arterial wall thickening (halo sign) was observed in the affected arterial segments. A frontal branch was precisely localized and infiltrated with 1% lidocaine. About 1 cm was removed for histopathologic examination. Thirty minutes was required to perform this outpatient procedure. The diagnosis of temporal arteritis was confirmed, and the patient was rapidly and successfully treated with prednisone. CONCLUSIONS: Color duplex ultrasonography allows precise localization of temporal arteries and its branches. This echocardiography-guided surgical procedure is easy and safe. Most dermatologic surgeons can perform it.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lifting is said to be on of the major risk factors for the onset of low back pain, several different measures has been developed to study this. Several programs are available in order to measure these components, or to determine the ability of an individual to perform a certain job or to discover if the job creates dangerous positions for the worker. In these different fields reliable and valid instruments exist but they are costly and time spending. We present a simplified functional capacity measuring that we use daily in practise. Method: 280 patients have been evaluated on this base. The majority was referred to multidisciplinary rehabilitation treatment. The patients had recurrent back problems for months or years. Inclusion criteria were between 18 and 64 years, currently of work, no work compensation. Exclusion criteria were chronic low back pain with a specific cause. They followed a one-hour evaluation test as a functional capacity evaluation at the end of the multidisciplinary treatment period, it was compared to the PILE-test done at the beginning and at the end. Results: We included 280 subjects: 160 men and 120 women. Mean age 43.6 by the women and 44 years by the men. We studied the caring foot-hip, hip-shoulder, 5 m carrying, pushing and tiring and the global weight carried during the test. We found this global value to be 696 kg by men and 422 kg by women suffering from chronic lumbar pain. The increase in this value had a clear incidence on a greater work ability, as had a decrease. Conclusions: We were able to develop a lifting capacity program that is easy to reproduce and not expensive, giving us the possibility to have an idea on how to reorient the patients according to their work place and their capacities. We could also have an information of work performance and power consumption. It should be more tested and compared to standard capacity in the healthy population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[Abstract] Reading volume and mammography screening performance appear positively correlated. Performance was compared across organised Swiss screening programmes, which target relatively small populations. Except for accreditation of 2nd readers radiologists (restrictive vs non-restrictive strategy), Swiss programmes have similar screening regimen/procedures and duration, which maximises comparability. Variation in performance was explored in order to improve mammography practice and optimise screening performance. Indicators of quality and effectiveness were evaluated for about 200,000 screens performed over 4 screening rounds in the 3 longest-standing Swiss cantonal programmes (of Vaud, Geneva and Valais). Interval cancers were identified by linkage with cancer registries records. Most European standards of performance were met with a favourable cancer stage shift. Several performance indicators showed substantial variation across programmes. In subsequent rounds, compared with programmes (Vaud and Geneva) which accredited few 2nd readers to increase their individual reading volume, proportions of in situ lesions and of small cancers (? 1cm) were one third lower and halved, respectively, and the proportion of advanced lesions (stage II+) nearly 50% higher in the programme without a restrictive selection strategy. Discrepancy in second-year proportional incidence of interval cancers appears to be multicausal. Differences in performance could partly be explained by a selective strategy for 2nd readers and a prior experience in service screening, but not by the levels of opportunistic screening and programme attendance. This study provides clues for enhancing mammography screening performance in low-volume Swiss programmes.

Relevância:

20.00% 20.00%

Publicador: