2 resultados para e-reading systems

em Université de Lausanne, Switzerland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this discussion, after a few general comments, I will propose a systems reading of the intervention so elegantly described by Kaija Puura. I will draw parallels between the therapeutic and the family groups as framing-developing systems and formalize the steps taken by the family toward healing under the influence of the therapist's team. En esta discusión, después de algunos comentarios generales, propongo una lectura sistemática de la intervención tan elegantemente descrita por Kaija Puura. Buscaré paralelos entre los grupos terapéuticos y de familia como sistemas de desarrollo enmarcado y formalizaré los pasos tomados por la familia hacia la cicatrización bajo la influencia del equipo del terapista. Après quelques commentaires généraux, je proposerai dans cette discussion une lecture systémique de l'intervention si élégamment décrite par Kaija Puura. J'établirai des parallèles entre les groupes thérapeutiques et familiaux en tant que systèmes d'encadrement-développement et je formaliserai les étapes de guérison franchies par la famille grâce à l'influence de l'équipe thérapeutique. In dieser Diskussion, werde ich nach einigen allgemeineren Aussagen, eine systemische Lesart der von Kaija Puura so eingängig beschriebenen Intervention vorschlagen. Ich werde darin Parallelen zwischen der therapeutischen und Rahmengebenden Familiengruppen ziehen, und die Schritte der Familien hin zu einer Heilung unter dem Einfluss des Therapeutenteams formalisieren.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work compares the detector performance and image quality of the new Kodak Min-R EV mammography screen-film system with the Fuji CR Profect detector and with other current mammography screen-film systems from Agfa, Fuji and Kodak. Basic image quality parameters (MTF, NPS, NEQ and DQE) were evaluated for a 28 kV Mo/Mo (HVL = 0.646 mm Al) beam using different mAs exposure settings. Compared with other screen-film systems, the new Kodak Min-R EV detector has the highest contrast and a low intrinsic noise level, giving better NEQ and DQE results, especially at high optical density. Thus, the properties of the new mammography film approach those of a fine mammography detector, especially at low frequency range. Screen-film systems provide the best resolution. The presampling MTF of the digital detector has a value of 15% at the Nyquist frequency and, due to the spread size of the laser beam, the use of a smaller pixel size would not permit a significant improvement of the detector resolution. The dual collection reading technology increases significantly the low frequency DQE of the Fuji CR system that can at present compete with the most efficient mammography screen-film systems.