2 resultados para dosimeter

em Université de Lausanne, Switzerland


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Physicians who frequently perform fluoroscopic examinations are exposed to high intensity radiation fields. The exposure monitoring is performed with a regular personal dosimeter under the apron in order to estimate the effective dose. However, large parts of the body are not protected by the apron (e.g. arms, head). Therefore, it is recommended to wear a supplemental dosimeter over the apron to obtain a better representative estimate of the effective dose. The over-apron dosimeter can also be used to estimate the eye lens dose. The goal of this study was to investigate the relevance of double dosimetry in interventional radiology. First the calibration procedure of the dosimeters placed over the apron was tested. Then, results of double dosimetry during the last five years were analyzed. We found that the personal dose equivalent measured over a lead apron was underestimated by ∼20% to ∼40% for X-ray beam qualities used in radiology. Measurements made over five-year period confirm that the use of a single under-apron dosimeter is inadequate for personnel monitoring. Relatively high skin dose (>10 mSv/month) would have remained undetected without a second dosimeter placed on the apron.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Depth-dose curves in LiF detectors of different effective thicknesses, together with their responses, were calculated for typical nuclear medicine radiation fields with 99mTc, 18F and 90Y sources. Responses were analysed in function of the radionuclide, detector effective thickness and irradiation geometry. On the other hand the results of the nuclear medicine measurement campaign of the ORAMED project were presented focussing on the dose distribution across the hand and on the appropriate position to wear the dosimeter.According to the results, thin LiF detectors provide better responses in all cases. Its use is essential for 18F, since thick dosimeters can underestimate Hp(0.07) up to a 50% because of the very inhomogeneous dose deposition on the active layer. The preliminary results of the measurement campaign showed that the index tip of the non-dominant hand is usually the most exposed position among the 22 monitored positions. It was also found that, in average, wrist dosimeters are likely to underestimate the maximum skin dose by a factor of the order of 20. This factor is reduced to around 6 for a ring dosimeter worn on the base of the index of the non-dominant hand. Thus, for typical nuclear medicine procedures, the base of the index of the non-dominant hand is recommended as the best monitoring option.