132 resultados para doping efficiency
em Université de Lausanne, Switzerland
Resumo:
Objectives To consider the various specific substances-taking activities in sport an examination of three psychological models of doping behaviour utilised by researchers is presented in order to evaluate their real and potential impact, and to improve the relevance and efficiency of anti-doping campaigns. Design Adopting the notion of a "research program" (Lakatos, 1978) from the philosophy of science, a range of studies into the psychology of doping behaviour are classified and critically analysed. Method Theoretical and practical parameters of three research programs are critically evaluated (i) cognitive; (ii) drive; and (iii) situated-dynamic. Results The analysis reveals the diversity of theoretical commitments of the research programs and their practical consequences. The «cognitive program» assumes that athletes are accountable for their acts that reflect the endeavour to attain sporting and non-sporting goals. Attitudes, knowledge and rational decisions are understood to be the basis of doping behaviour. The «drive program» characterises the variety of traces and consequences on psychological and somatic states coming from athlete's experience with sport. Doping behaviour here is conceived of as a solution to reduce unconscious psychological and somatic distress. The «situated-dynamic program» considers a broader context of athletes' doping activity and its evolution during a sport career. Doping is considered as emergent and self-organized behaviour, grounded on temporally critical couplings between athletes' actions and situations and the specific dynamics of their development during the sporting life course. Conclusions These hypothetical, theoretical and methodological considerations offer a more nuanced understanding of doping behaviours, making an effective contribution to anti-doping education and research by enabling researchers and policy personnel to become more critically reflective about their explicit and implicit assumptions regarding models of explanations for doping behaviour.
Resumo:
The potential and applicability of UHPSFC-MS/MS for anti-doping screening in urine samples were tested for the first time. For this purpose, a group of 110 doping agents with diverse physicochemical properties was analyzed using two separation techniques, namely UHPLC-MS/MS and UHPSFC-MS/MS in both ESI+ and ESI- modes. The two approaches were compared in terms of selectivity, sensitivity, linearity and matrix effects. As expected, very diverse retentions and selectivities were obtained in UHPLC and UHPSFC, proving a good complementarity of these analytical strategies. In both conditions, acceptable peak shapes and MS detection capabilities were obtained within 7min analysis time, enabling the application of these two methods for screening purposes. Method sensitivity was found comparable for 46% of tested compounds, while higher sensitivity was observed for 21% of tested compounds in UHPLC-MS/MS and for 32% in UHPSFC-MS/MS. The latter demonstrated a lower susceptibility to matrix effects, which were mostly observed as signal suppression. In the case of UHPLC-MS/MS, more serious matrix effects were observed, leading typically to signal enhancement and the matrix effect was also concentration dependent, i.e., more significant matrix effects occurred at the lowest concentrations.
Resumo:
Big sports events like the 2008 European Football Championship are a challenge for anti-doping activities, particularly when the sports event is hosted by two different countries and there are two laboratories accredited by the World Anti-Doping Agency. This challenges the logistics of sample collection as well as the chemical analyses, which must be carried out timeously. The following paper discusses the handling of whereabouts information for each athlete and the therapeutic use exemption system, experiences in sample collection and transportation of blood and urine samples, and the results of the chemical analysis in two different accredited laboratories. An overview of the analytical results of blood profiling and growth hormone testing in comparison with the distribution of the normal population is also presented.
Resumo:
Summary : Internal ribosome entry sites (IRES) are used by viruses as a strategy to bypass inhibition of cap-dependent translation that commonly results from viral infection. IRES are also used in eukaryotic cells to control mRNA translation under conditions of cellular stress (apoptosis, heat shock) or during the G2 phase of the cell cycle when general protein synthesis is inhibited. Variation in cellular expression levels has been shown to be inherited. Expression is controlled, among others, by transcriptional factors and by the efficiency of cap-mediated translation and ribosome activity. We aimed at identifying genomic determinants of variability in IRES-mediated translation of two representative IRES [Encephalomyocarditis virus (EMCV) and X-linked Inhibitor-of-Apoptosis (XIAP) IRES]. We used bicistronic lentiviral constructions expressing two fluorescent reporter transgenes. Lentiviruses were used to transduce seven different laboratory cell lines and B lymphoblastoid cell lines from the Centre d'Etude du Polymorphisme Humain (CEPH; 15 pedigrees; n=209); representing an in vitro approach to family structure allowing genome scan analyses. The relative expression of the two markers was assessed by FACS. IRES efficiency varies according to cellular background, but also varies, for a same cell type, among individuals. The control of IRES activity presents an inherited component (h2) of 0.47 and 0.36 for EMCV and XIAP IRES, respectively. A genome scan identified a suggestive Quantitative Trait Loci (LOD 2.35) involved in the control of XIAP IRES activity. Résumé : Les sites internes d'entrée des ribosomes (IRES = internal ribosome entry sites) sont utilisés par les virus comme une stratégie afin d'outrepasser l'inhibition de traduction qui résulte communément d'une infection virale. Les IRES sont également utilisés par les cellules eucaryotes pour contrôler la traduction de l'ARN messager dans des conditions de stress cellulaire (apoptose, choc thermique) ou durant la phase G2 du cycle cellulaire, situations durant lesquelles la synthèse générale des protéines est inhibée. La variation des niveaux d'expression cellulaire de transcription est un caractère héréditaire. L'expression des gènes est contrôlée entre autre par les facteurs de transcription et par l'efficacité de la traduction initiée par la coiffe ainsi que par l'activité des ribosomes. Durant cette étude nous avons eu pour but d'identifier les déterminants génomiques responsables de la variabilité de la traduction contrôlée par l'IRES. Ceci a été effectué en étudiant deux IRES représentatifs : l'IRES du virus de l'encéphalomyocardite (EMCV) et l'IRES de l'inhibiteur de l'apoptose XIAP (X-linked Inhibitor-of-Apoptosis). Nous avons utilisés des lentivirus délivrant un transgène bicistronique codant pour deux gènes rapporteurs fluorescents. Ces lentivirus ont été utilisés pour transduire sept différentes lignées cellulaires de laboratoire et des lignées cellulaires lymphoblastoïdes B du Centre d'Etude du Polymorphisme Humain (CEPH; 15 pedigrees; n=209) qui représentent une approche in vitro de la structure familiale et qui permettent des analyses par balayage du génome. L'expression relative des deux marqueurs fluorescents a été analysée par FACS. Nos résultats montrent que l'efficacité des IRES varie en fonction du type de cellules. Il varie aussi, pour le même type de cellules, selon les individus. Le contrôle de l'activité de l'IRES est un caractère héritable (héritabilité h2) de 0.47 et 0.36 pour les IRES de EMCV et XIAP respectivement. Le balayage du génome a permis l'identification d'un locus à effets quantitatifs [QTL Quantitative Trait Loci (LOD 2.35)] impliqué dans le contôle de l'activité de l'IRES de XIAP.
Resumo:
ABSTRACT: BACKGROUND: There is no recommendation to screen ferritin level in blood donors, even though several studies have noted the high prevalence of iron deficiency after blood donation, particularly among menstruating females. Furthermore, some clinical trials have shown that non-anaemic women with unexplained fatigue may benefit from iron supplementation. Our objective is to determine the clinical effect of iron supplementation on fatigue in female blood donors without anaemia, but with a mean serum ferritin </= 30 ng/ml. METHODS/DESIGN: In a double blind randomised controlled trial, we will measure blood count and ferritin level of women under age 50 yr, who donate blood to the University Hospital of Lausanne Blood Transfusion Department, at the time of the donation and after 1 week. One hundred and forty donors with a ferritin level </= 30 ng/ml and haemoglobin level >/= 120 g/l (non-anaemic) a week after the donation will be included in the study and randomised. A one-month course of oral ferrous sulphate (80 mg/day of elemental iron) will be introduced vs. placebo. Self-reported fatigue will be measured using a visual analogue scale. Secondary outcomes are: score of fatigue (Fatigue Severity Scale), maximal aerobic power (Chester Step Test), quality of life (SF-12), and mood disorders (Prime-MD). Haemoglobin and ferritin concentration will be monitored before and after the intervention. DISCUSSION: Iron deficiency is a potential problem for all blood donors, especially menstruating women. To our knowledge, no other intervention study has yet evaluated the impact of iron supplementation on subjective symptoms after a blood donation. TRIAL REGISTRATION: NCT00689793.
Resumo:
Background: Retrospective analyses suggest that personalized PK-based dosage might be useful for imatinib, as treatment response correlates with trough concentrations (Cmin) in cancer patients. Our objectives were to improve the interpretation of randomly measured concentrations and to confirm its efficiency before evaluating the clinical usefulness of systematic PK-based dosage in chronic myeloid leukemia patients. Methods and Results: A Bayesian method was validated for the prediction of individual Cmin on the basis of a single random observation, and was applied in a prospective multicenter randomized controlled clinical trial. 28 out of 56 patients were enrolled in the systematic dosage individualization arm and had 44 follow-up visits (their clinical follow-up is ongoing). PK-dose-adjustments were proposed in 39% having predicted Cmin significantly away from the target (1000 ng/ml). Recommendations were taken up by physicians in 57%, patients were considered non-compliant in 27%. Median Cmin at study inclusion was 754 ng/ml and differed significantly from the target (p=0.02, Wilcoxon test). On follow-up, Cmin was 984 ng/ml (p=0.82) in the compliant group. CV decreased from 46% to 27% (p=0.02, F-test). Conclusion: PK-based (Bayesian) dosage adjustment is able to bring individual drug exposure closer to a given therapeutic target. Its influence on therapeutic response remains to be evaluated.
Resumo:
Introduction: The general strategy to perform anti-doping analysis starts with a screening followed by a confirmatory step when a sample is suspected to be positive. The screening step should be fast, generic and able to highlight any sample that may contain a prohibited substance by avoiding false negative and reducing false positive results. The confirmatory step is a dedicated procedure comprising a selective sample preparation and detection mode. Aim: The purpose of the study is to develop rapid screening and selective confirmatory strategies to detect and identify 103 doping agents in urine. Methods: For the screening, urine samples were simply diluted by a factor 2 with ultra-pure water and directly injected ("dilute and shoot") in the ultrahigh- pressure liquid chromatography (UHPLC). The UHPLC separation was performed in two gradients (ESI positive and negative) from 5/95 to 95/5% of MeCN/Water containing 0.1% formic acid. The gradient analysis time is 9 min including 3 min reequilibration. Analytes detection was performed in full scan mode on a quadrupole time-of-flight (QTOF) mass spectrometer by acquiring the exact mass of the protonated (ESI positive) or deprotonated (ESI negative) molecular ion. For the confirmatory analysis, urine samples were extracted on SPE 96-well plate with mixed-mode cation (MCX) for basic and neutral compounds or anion exchange (MAX) sorbents for acidic molecules. The analytes were eluted in 3 min (including 1.5 min reequilibration) with a S1-25 Ann Toxicol Anal. 2009; 21(S1) Abstracts gradient from 5/95 to 95/5% of MeCN/Water containing 0.1% formic acid. Analytes confirmation was performed in MS and MS/MS mode on a QTOF mass spectrometer. Results: In the screening and confirmatory analysis, basic and neutral analytes were analysed in the positive ESI mode, whereas acidic compounds were analysed in the negative mode. The analyte identification was based on retention time (tR) and exact mass measurement. "Dilute and shoot" was used as a generic sample treatment in the screening procedure, but matrix effect (e.g., ion suppression) cannot be avoided. However, the sensitivity was sufficient for all analytes to reach the minimal required performance limit (MRPL) required by the World Anti Doping Agency (WADA). To avoid time-consuming confirmatory analysis of false positive samples, a pre-confirmatory step was added. It consists of the sample re-injection, the acquisition of MS/MS spectra and the comparison to reference material. For the confirmatory analysis, urine samples were extracted by SPE allowing a pre-concentration of the analyte. A fast chromatographic separation was developed as a single analyte has to be confirmed. A dedicated QTOF-MS and MS/MS acquisition was performed to acquire within the same run a parallel scanning of two functions. Low collision energy was applied in the first channel to obtain the protonated molecular ion (QTOF-MS), while dedicated collision energy was set in the second channel to obtain fragmented ions (QTOF-MS/MS). Enough identification points were obtained to compare the spectra with reference material and negative urine sample. Finally, the entire process was validated and matrix effects quantified. Conclusion: Thanks to the coupling of UHPLC with the QTOF mass spectrometer, high tR repeatability, sensitivity, mass accuracy and mass resolution over a broad mass range were obtained. The method was sensitive, robust and reliable enough to detect and identify doping agents in urine. Keywords: screening, confirmatory analysis, UHPLC, QTOF, doping agents
Resumo:
C.E.R.A., a continuous erythropoietin receptor activator, is a new third-generation erythropoiesis-stimulating agent (ESA) that has recently been linked with abuse in endurance sports. In order to combat this new form of doping, we examined an enzyme-linked immunosorbent assay (ELISA) designed to detect the presence of C.E.R.A. in serum samples. The performance of the assay was evaluated using a pilot excretion study that involved six subjects receiving C.E.R.A. Validation data demonstrated an excellent reproducibility and ensured the applicability of the assay for anti-doping purposes. To maximize the chances of detecting the drug in serum samples, we propose the use of this specific ELISA test as a high-throughput screening method, combined with a classic isoelectric focusing test as a confirmatory assay. This strategy should make C.E.R.A. abuse relatively easy to detect, thereby preventing the future use of this drug as a doping agent.
Resumo:
The increase of the body's capacity to transport oxygen is a prime target for doping athletes in all endurance sports. For this pupose, blood transfusions or erythropoiesis stimulating agents (ESA), such as erythropoietin, NESP, and CERA are used. As direct detection of such manipulations is difficult, biomarkers that are connected to the haematopoietic system (haemoglobin concentration, reticulocytes) are monitored over time (Athlete Biological Passport (ABP)) and analyzed using mathematical models to identify patterns suspicious of doping. With this information, athletes can either be sanctioned directly based on their profile or targeted with conventional doping tests. Key issues for the appropriate use of the ABP are correct targeting and use of all available information (e.g. whereabouts, cross sectional population data) in a forensic manner. Future developments of the passport include the correction of all concentration-based variables for shifts in plasma volume, which might considerably increase sensitivity. New passport markers from the genomic, proteomic, and metabolomic level might add further information, but need to be validated before integration into the passport procedure. A first assessment of blood data of federations that have implemented the passport show encouraging signs of a decreased blood-doping prevalence in their athletes, which adds scientific credibility to this innovative concept in the fight against ESA- and blood doping. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
The aim of the present article was to present a specific activity approach called the 'life course of a practice' that could be used for the analysis of the long-term dynamic of learning within diverse social practices. The cases of unethical actions (doping) within a population of high-level athletes were examined, considering they could be fruitful exam- 10 ples for this type of analysis. After describing the theoretical construct 'life course of a practice', the places of these unethical actions in the sporting life courses and elements that characterize their emergence in the long-term dynamics are described. Last, targeted prevention measures of unethical actions over a lifetime are presented.