38 resultados para dental prostheses
em Université de Lausanne, Switzerland
Resumo:
Purpose: The aim of this review was to systematically evaluate and compare the frequency of veneer chipping and core fracture of zirconia fixed dental prostheses (FOPS) and porcelain-fused-to-metal (PFM) FDPs and determine possible influencing factors. Materials and Methods: The SCOPUS database and International Association of Dental Research abstracts were searched for clinical studies involving zirconia and PFM FDPs. Furthermore, studies that were integrated into systematic reviews on PFM FDPs were also evaluated. The principle investigators of any clinical studies on zirconia FDPs were contacted to provide additional information. Based on the available information for each FOP, a data file was constructed. Veneer chipping was divided into three grades (grade 1 = polishing, grade 2 = repair, grade 3 = replacement). To assess the frequency of veneer chipping and possible influencing factors, a piecewise exponential model was used to adjust for a study effect. Results: None of the studies on PFM FDPs (reviews and additional searching) sufficiently satisfied the criteria of this review to be included. Thirteen clinical studies on zirconia FDPs and two studies that investigated both zirconia and PFM FDPs were identified. These studies involved 664 zirconia and 134 PFM FDPs at baseline. Follow-up data were available for 595 zirconia and 127 PFM FDPs. The mean observation period was approximately 3 years for both groups. The frequency of core fracture was less than 1% in the zirconia group and 0% in the PFM group. When all studies were included, 142 veneer chippings were recorded for zirconia FDPs (24%) and 43 for PFM FDPs (34%). However, the studies differed extensively with regard to veneer chipping of zirconia: 85% of all chippings occurred in 4 studies, and 43% of all chippings included zirconia FDPs. If only studies that evaluated both types of core materials were included, the frequency of chipping was 54% for the zirconia-supported FDPs and 34% for PFM FDPs. When adjusting the survival rate for the study effect, the difference between zirconia and PFM FDPs was statistically significant for all grades of chippings (P = .001), as well as for chipping grade 3 (P = .02). If all grades of veneer chippings were taken into account, the survival of PFM FDPs was 97%, while the survival rate of the zirconia FDPs was 90% after 3 years for a typical study. For both PFM and zirconia FDPs, the frequency of grades 1 and 2 veneer chippings was considerably higher than grade 3. Veneer chipping was significantly less frequent in pressed materials than in hand-layered materials, both for zirconia and PFM FDPs (P = .04). Conclusions: Since the frequency of veneer chipping was significantly higher in the zirconia FDPs than PFM FDPs, and as refined processing procedures have started to yield better results in the laboratory, new clinical studies with these new procedures must confirm whether the frequency of veneer chipping can be reduced to the level of PFM. Int J Prosthodont 2010;23:493-502
Resumo:
BACKGROUND: Total orbital exenteration is a radical surgical procedure, which typically involves the removal of the entire contents of the orbit including the periorbita, leaving the patient with a deep orbital deformity and results in devastating cosmetic, functional, and psychological consequences requiring difficult and challenging procedures for oculoplastic surgeons. Oculofacial prostheses retained by endosseous dental implants present an attractive and viable alternative when aesthetic and functional demands are beyond the capacity of local reconstructive efforts. PATIENTS AND METHODS: A 72-year-old woman presenting a malignant melanoma of the right eyelids and a 77-year-old man presenting a sebaceous carcinoma of the left upper eyelid underwent a total exenteration followed by positioning of endosseous implants (Straumann system Dental implants) as an integrated one-step combined surgical procedure. The oculofacial prosthesis was placed after epithelialization of the orbital cavity. RESULTS: The implants were perfectly osseointegrated without any complications, providing sufficient retention of the prostheses. A satisfactory aesthetic outcome has been achieved for both patients. CONCLUSIONS: Oculofacial prostheses anchored by osseointegrated dental implants placed as one-step surgical procedure ensure an adequate aesthetic result as well as a considerably decreased rehabilitation time and present a satisfactory solution when reconstruction is not a suitable option.
Resumo:
BACKGROUND: Clinical small-caliber vascular prostheses are unsatisfactory. Reasons for failure are early thrombosis and late intimal hyperplasia. We thus prepared biodegradable small-caliber vascular prostheses using electrospun polycaprolactone (PCL) with slow-releasing paclitaxel (PTX), an antiproliferative drug. METHODS AND RESULTS: PCL solutions containing PTX were used to prepare nonwoven nanofibre-based 2-mm ID prostheses. Mechanical morphological properties and drug loading, distribution, and release were studied in vitro. Infrarenal abdominal aortic replacement was carried out with nondrug-loaded and drug-loaded prostheses in 18 rats and followed for 6 months. Patency, stenosis, tissue reaction, and drug effect on endothelialization, vascular remodeling, and neointima formation were studied in vivo. In vitro prostheses showed controlled morphology mimicking extracellular matrix with mechanical properties similar to those of native vessels. PTX-loaded grafts with suitable mechanical properties and controlled drug-release were obtained by factorial design. In vivo, both groups showed 100% patency, no stenosis, and no aneurysmal dilatation. Endothelial coverage and cell ingrowth were significantly reduced at 3 weeks and delayed at 12 and 24 weeks in PTX grafts, but as envisioned, neointima formation was significantly reduced in these grafts at 12 weeks and delayed at 6 months. CONCLUSIONS: Biodegradable, electrospun, nanofibre, polycaprolactone prostheses are promising because in vitro they maintain their mechanical properties (regardless of PTX loading), and in vivo show good patency, reendothelialize, and remodel with autologous cells. PTX loading delays endothelialization and cellular ingrowth. Conversely, it reduces neointima formation until the end point of our study and thus may be an interesting option for small caliber vascular grafts.
Resumo:
The treatment of hip osteoarthritis with total hip arthroplasty has continuously evolved since it was first introduced in the sixties. The problem of aseptic loosening of the cemented prostheses, mainly in young active patients, has stimulated two different types of research: on one side the improvement of cementing techniques and on the other side the development of cementless osteoinegrable implants. We discuss the problems of these cementless hip prostheses. Recently published anatomic and biomechanic studies have led to the development of personalized custom femoral stems for each patient. The conception technique and first clinical results are described.
Resumo:
BACKGROUND: Dentists are in a unique position to advise smokers to quit by providing effective counseling on the various aspects of tobacco-induced diseases. The present study assessed the feasibility and acceptability of integrating dentists in a medical smoking cessation intervention. METHODS: Smokers willing to quit underwent an 8-week smoking cessation intervention combining individual-based counseling and nicotine replacement therapy and/or bupropion, provided by a general internist. In addition, a dentist performed a dental exam, followed by an oral hygiene treatment and gave information about chronic effects of smoking on oral health. Outcomes were acceptability, global satisfaction of the dentist's intervention, and smoking abstinence at 6-month. RESULTS: 39 adult smokers were included, and 27 (69%) completed the study. Global acceptability of the dental intervention was very high (94% yes, 6% mostly yes). Annoyances at the dental exam were described as acceptable by participants (61% yes, 23% mostly yes, 6%, mostly no, 10% no). Participants provided very positive qualitative comments about the dentist counseling, the oral exam, and the resulting motivational effect, emphasizing the feeling of oral cleanliness and health that encouraged smoking abstinence. At the end of the intervention (week 8), 17 (44%) participants reported smoking abstinence. After 6 months, 6 (15%, 95% CI 3.5 to 27.2) reported a confirmed continuous smoking abstinence. DISCUSSION: We explored a new multi-disciplinary approach to smoking cessation, which included medical and dental interventions. Despite the small sample size and non-controlled study design, the observed rate was similar to that found in standard medical care. In terms of acceptability and feasibility, our results support further investigations in this field. TRIAL REGISTRATION NUMBER: ISRCTN67470159.
Resumo:
Reversed shoulder prostheses are increasingly being used for the treatment of glenohumeral arthropathy associated with a deficient rotator cuff. These non-anatomical implants attempt to balance the joint forces by means of a semi-constrained articular surface and a medialised centre of rotation. A finite element model was used to compare a reversed prosthesis with an anatomical implant. Active abduction was simulated from 0 degrees to 150 degrees of elevation. With the anatomical prosthesis, the joint force almost reached the equivalence of body weight. The joint force was half this for the reversed prosthesis. The direction of force was much more vertically aligned for the reverse prosthesis, in the first 90 degrees of abduction. With the reversed prosthesis, abduction was possible without rotator cuff muscles and required 20% less deltoid force to achieve it. This force analysis confirms the potential mechanical advantage of reversed prostheses when rotator cuff muscles are deficient.
Resumo:
The development of bacterial endocarditis was analyzed after dental extractions in rats with or without periodontal disease. Periodontal disease was produced in rats by tying silk ligatures around the two maxillary first molars and placing the animals on a high sucrose diet for 14 weeks. Sterile aortic valve vegetations were produced by means of a transaortic catheter, and 24 hr later the maxillary first molars were extracted. The animals were killed 72 hr after the extractions. In rats with periodontal disease, extractions resulted in a 48% (14 of 29) incidence of bacterial endocarditis, most cases of which were due to Streptococcus spp. (one was caused by Staphylococcus aureus). In contrast, when the teeth with a healthy periodontium were extracted, only 6% (one of 15) of the rats developed endocarditis. When catheters were placed in animals with periodontal disease but no extractions were performed, no endocarditis occurred.
Resumo:
Jalili syndrome denotes a recessively inherited combination of an eye disease (cone-rod dystrophy) and a dental disorder (amelogenesis imperfecta), which is caused by mutations in the CNNM4 gene. Whereas the ophthalmic consequences of these mutations have been studied comprehensively, the dental phenotype has obtained less attention. A defective transport of magnesium ions by the photoreceptors of the retina is assumed to account for the progressive visual impairment. Since magnesium is also incorporated in the mineral of dental hard tissues, we hypothesized that magnesium concentrations in defective enamel resulting from mutations in CNNM4 would be abnormal, if a similar deficiency of magnesium transport also accounted for the amelogenesis imperfecta. Thus, a detailed analysis of the dental hard tissues was performed in two boys of Kosovan origin affected by Jalili syndrome. Retinal dystrophy of the patients was diagnosed by a comprehensive eye examination and full-field electroretinography. A mutational analysis revealed a c.1312 dupC homozygous mutation in CNNM4, a genetic defect which had already been identified in other Kosovan families and putatively results in loss-of-function of the protein. The evaluation of six primary teeth using light and scanning electron microscopy as well as energy-dispersive X-ray spectroscopy showed that dental enamel was thin and deficient in mineral, suggesting a hypoplastic/hypomineralized type of amelogenesis imperfecta. The reduced mineral density of enamel was accompanied by decreased amounts of calcium, but significantly elevated levels of magnesium. In dentin, however, a similar mineral deficiency was associated with reduced magnesium and normal calcium levels. It is concluded that the c.1312 dupC mutation of CNNM4 results in mineralization defects of both enamel and dentin, which are associated with significantly abnormal magnesium concentrations. Thus, we could not disprove the hypothesis that a disrupted magnesium transport is involved in the development of the dental abnormalities observed in Jalili syndrome.
Resumo:
Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movement and joint stability were achieved by EMG-controlled activation of the muscles. A non-constant wear factor was considered. Simulated activities of daily living were estimated from in vivo recorded data. After one year of use, the volumetric wear was 8.4 mm(3) for the anatomical prosthesis, but 44.6 mm(3) for the reversed version. For the anatomical prosthesis the predictions for contact pressure and wear were consistent with biomechanical and clinical data. The abrasive wear of the polyethylene in reversed prostheses should not be underestimated, and further analysis, both experimental and clinical, is required.
Resumo:
HYPOTHESIS: The nonanatomical design of reverse shoulder prostheses induce medial displacement of the center of rotation, impingements and may reduce the mobility of the shoulder. The aim of this study is to test the hypothesis that during activities of daily living functional mobility of the shoulder can be restored by scapular compensation. MATERIAL AND METHODS: A numerical 3-dimensional model was developed to reproduce the movement of the scapula and humerus, during 4 activities of daily living measured experimentally. This hypothesis was tested in 4 configurations of the aequalis reverse prosthesis (standard 36-mm glenosphere, 42-mm glenosphere, lateralized 36-mm glenosphere, lateralized Bony Increased-Offset Reverse Shoulder Arthroplasty [BIO-RSA]), which were implanted in the virtual model. All impingement positions were evaluated, as the required scapular compensation to avoid impingements. RESULTS: With the 36-mm glenosphere, impingements occurred only for rest of hand to back-pocket positions. The 42-mm partly improved the mobility. The 2 lateralized glenospheres were free of impingement. When impingements occurred, the scapular compensation was less than 10°. CONCLUSION: Most reverse prostheses impingements reported in clinical and biomechanical studies can be avoided, either by scapular compensation or by a glenosphere lateralization. After reverse shoulder arthroplasty, a fraction of the mobility of the gleno-humeral is transferred to the scapulo-thoracic joint.