105 resultados para correction factors

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The quantity of interest for high-energy photon beam therapy recommended by most dosimetric protocols is the absorbed dose to water. Thus, ionization chambers are calibrated in absorbed dose to water, which is the same quantity as what is calculated by most treatment planning systems (TPS). However, when measurements are performed in a low-density medium, the presence of the ionization chamber generates a perturbation at the level of the secondary particle range. Therefore, the measured quantity is close to the absorbed dose to a volume of water equivalent to the chamber volume. This quantity is not equivalent to the dose calculated by a TPS, which is the absorbed dose to an infinitesimally small volume of water. This phenomenon can lead to an overestimation of the absorbed dose measured with an ionization chamber of up to 40% in extreme cases. In this paper, we propose a method to calculate correction factors based on the Monte Carlo simulations. These correction factors are obtained by the ratio of the absorbed dose to water in a low-density medium □D(w,Q,V1)(low) averaged over a scoring volume V₁ for a geometry where V₁ is filled with the low-density medium and the absorbed dose to water □D(w,QV2)(low) averaged over a volume V₂ for a geometry where V₂ is filled with water. In the Monte Carlo simulations, □D(w,QV2)(low) is obtained by replacing the volume of the ionization chamber by an equivalent volume of water, according to the definition of the absorbed dose to water. The method is validated in two different configurations which allowed us to study the behavior of this correction factor as a function of depth in phantom, photon beam energy, phantom density and field size.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fluid that fills boreholes in crosswell electrical resistivity investigations provides the necessary electrical contact between the electrodes and the rock formation but it is also the source of image artifacts in standard inversions that do not account for the effects of the boreholes. The image distortions can be severe for large resistivity contrasts between the rock formation and borehole fluid and for large borehole diameters. We have carried out 3D finite-element modeling using an unstructured-grid approach to quantify the magnitude of borehole effects for different resistivity contrasts, borehole diameters, and electrode configurations. Relatively common resistivity contrasts of 100:1 and borehole diameters of 10 and 20 cm yielded, for a bipole length of 5 m, apparent resistivity underestimates of approximately 12% and 32% when using AB-MN configurations and apparent resistivity overestimates of approximately 24% and 95% when using AM-BN configurations. Effects are generally more severe at shorter bipole spacings. We report the results obtained by either including or ignoring the boreholes in inversions of 3D field data from a test site in Switzerland, where approximately 10,000 crosswell resistivity-tomography measurements were made across six acquisition planes among four boreholes. Inversions of raw data that ignored the boreholes filled with low-resistivity fluid paradoxically produced high-resistivity artifacts around the boreholes. Including correction factors based on the modeling results fora ID model with and without the boreholes did not markedly improve the images. The only satisfactory approach was to use a 3D inversion code that explicitly incorporated the boreholes in the actual inversion. This new approach yielded an electrical resistivity image that was devoid of artifacts around the boreholes and that correlated well with coincident crosswell radar images.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Osteoporosis is a serious worldwide epidemic. FRAX® is a web-based tool developed by the Sheffield WHO Collaborating Center team, that integrates clinical risk factors and femoral neck BMD and calculates the 10 year fracture probability in order to help health care professionals identify patients who need treatment. However, only 31 countries have a FRAX® calculator. In the absence of a FRAX® model for a particular country, it has been suggested to use a surrogate country for which the epidemiology of osteoporosis most closely approximates the index country. More specific recommendations for clinicians in these countries are not available. In North America, concerns have also been raised regarding the assumptions used to construct the US ethnic specific FRAX® calculators with respect to the correction factors applied to derive fracture probabilities in Blacks, Asians and Hispanics in comparison to Whites. In addition, questions were raised about calculating fracture risk in other ethnic groups e.g., Native Americans and First Canadians. The International Society for Clinical Densitometry (ISCD) in conjunction with the International Osteoporosis Foundation (IOF) assembled an international panel of experts that ultimately developed joint Official Positions of the ISCD and IOF advising clinicians regarding FRAX® usage. As part of the process, the charge of the FRAX® International Task Force was to review and synthesize data regarding geographic and race/ethnic variability in hip fractures, non-hip osteoporotic fractures, and make recommendations about the use of FRAX® in ethnic groups and countries without a FRAX® calculator. This synthesis was presented to the expert panel and constitutes the data on which the subsequent Official Positions are predicated. A summary of the International Task Force composition and charge is presented here.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Osteoporosis is a serious worldwide epidemic. Increased risk of fractures is the hallmark of the disease and is associated with increased morbidity, mortality and economic burden. FRAX® is a web-based tool developed by the Sheffield WHO Collaborating Center team, that integrates clinical risk factors, femoral neck BMD, country specific mortality and fracture data and calculates the 10 year fracture probability in order to help health care professionals identify patients who need treatment. However, only 31 countries have a FRAX® calculator at the time paper was accepted for publication. In the absence of a FRAX® model for a particular country, it has been suggested to use a surrogate country for which the epidemiology of osteoporosis most closely approximates the index country. More specific recommendations for clinicians in these countries are not available. In North America, concerns have also been raised regarding the assumptions used to construct the US ethnic specific FRAX® calculators with respect to the correction factors applied to derive fracture probabilities in Blacks, Asians and Hispanics in comparison to Whites. In addition, questions were raised about calculating fracture risk in other ethnic groups e.g., Native Americans and First Canadians. In order to provide additional guidance to clinicians, a FRAX® International Task Force was formed to address specific questions raised by physicians in countries without FRAX® calculators and seeking to integrate FRAX® into their clinical practice. The main questions that the task force tried to answer were the following: The Task Force members conducted appropriate literature reviews and developed preliminary statements that were discussed and graded by a panel of experts at the ISCD-IOF joint conference. The statements approved by the panel of experts are discussed in the current paper.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: Diaphragmatic navigators are frequently used in free-breathing coronary MR angiography, either to gate or prospectively correct slice position or both. For such approaches, a constant relationship between coronary and diaphragmatic displacement throughout the respiratory cycle is assumed. The purpose of this study was to evaluate the relationship between diaphragmatic and coronary artery motion during free breathing. SUBJECTS AND METHODS: A real-time echoplanar MR imaging sequence was used in 12 healthy volunteers to obtain 30 successive images each (one per cardiac cycle) that included the left main coronary artery and the domes of both hemidiaphragms. The coronary artery and diaphragm positions (relative to isocenter) were determined and analyzed for effective diaphragmatic gating windows of 3, 5, and 7 mm (diaphragmatic excursions of 0-3, 0-5, and 0-7 mm from the end-expiratory position, respectively). RESULTS: Although the mean slope correlating the displacement of the right diaphragm and the left main coronary artery was approximately 0.6 for all diaphragmatic gating windows, we also found great variability among individual volunteers. Linear regression slopes varied from 0.17 to 0.93, and r2 values varied from .04 to .87. CONCLUSION: Wide individual variability exists in the relationship between coronary and diaphragmatic respiratory motion during free breathing. Accordingly, coronary MR angiographic approaches that use diaphragmatic navigator position for prospective slice correction may benefit from patient-specific correction factors. Alternatively, coronary MR angiography may benefit from a more direct assessment of the respiratory displacement of the heart and coronary arteries, using left ventricular navigators.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Active personal dosemeters (APD) have been found to be very efficient tools to reduce occupational doses in many applications of ionizing radiation. In order to be used in interventional radiology and cardiology (IR/IC), APDs should be able to measure low energy photons and pulsed radiation with relatively high instantaneous personal dose equivalent rates. A study concerning the optimization of the use of APDs in IR/IC was performed in the framework of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Program. In particular, eight commercial APDs were tested in continuous and pulsed X-ray fields delivered by calibration laboratories in order to evaluate their performances. Most of APDs provide a response in pulsed mode more or less affected by the personal dose equivalent rate, which means they could be used in routine monitoring provided that correction factors are introduced. These results emphasize the importance of adding tests in pulsed mode in type-test procedures for APDs. Some general recommendations are proposed in the end of this paper for the selection and use of APDs at IR/IC workplaces.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Surgical correction of complete atrio-ventricular septal defect (AVSD) achieves satisfactory results with low morbidity and mortality, but may require reoperation. Our recent operative results at mid-term were followed-up. METHODS: From June 2000 to December 2007, 81 patients (Down syndrome; n=60), median age 4.0 months (range 0.7-118.6) and weight 4.7kg (range 2.2-33), underwent complete AVSD correction. Patch closure for the ventricular septal defect (VSD; n=69) and atrial septal defect (ASD; n=42) was performed with left atrio-ventricular valve (LAVV) cleft closure (n=76) and right atrio-ventricular valve (RAVV) repair (n=57). Mortality, morbidity, and indications for reoperation were retrospectively studied; the end point 'time to reoperation' was analyzed using Kaplan-Meier curves. Follow-up was complete except in two patients and spanned a median of 28 months (range 0.4-6.1 years). RESULTS: In-hospital mortality was 3.7% (n=3) and one late death occurred. Reoperation was required in 7/79 patients (8.9%) for LAVV insufficiency (n=4), for a residual ASD (n=1), for right atrio-ventricular valve insufficiency (n=1), and for subaortic stenosis (n=1). At last follow-up, no or only mild LAVV and RAVV insufficiency was present in 81.3% and 92.1% of patients, respectively, and 2/3 of patients were medication-free. Risk factors for reoperation were younger age (<3 months; p=0.001) and lower weight (<4kg; p=0.003), and a trend towards less and later reoperations in Down syndrome (p<0.2). CONCLUSIONS: Surgical correction of AVSD can be achieved with low mortality and need for reoperation, regardless of Down syndrome or not. Immediate postoperative moderate or more residual atrio-ventricular valve insufficiency will eventually require a reoperation, and could be anticipated in patients younger than 3 months and weighing <4kg.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We evaluated the performance of an optical camera based prospective motion correction (PMC) system in improving the quality of 3D echo-planar imaging functional MRI data. An optical camera and external marker were used to dynamically track the head movement of subjects during fMRI scanning. PMC was performed by using the motion information to dynamically update the sequence's RF excitation and gradient waveforms such that the field-of-view was realigned to match the subject's head movement. Task-free fMRI experiments on five healthy volunteers followed a 2×2×3 factorial design with the following factors: PMC on or off; 3.0mm or 1.5mm isotropic resolution; and no, slow, or fast head movements. Visual and motor fMRI experiments were additionally performed on one of the volunteers at 1.5mm resolution comparing PMC on vs PMC off for no and slow head movements. Metrics were developed to quantify the amount of motion as it occurred relative to k-space data acquisition. The motion quantification metric collapsed the very rich camera tracking data into one scalar value for each image volume that was strongly predictive of motion-induced artifacts. The PMC system did not introduce extraneous artifacts for the no motion conditions and improved the time series temporal signal-to-noise by 30% to 40% for all combinations of low/high resolution and slow/fast head movement relative to the standard acquisition with no prospective correction. The numbers of activated voxels (p<0.001, uncorrected) in both task-based experiments were comparable for the no motion cases and increased by 78% and 330%, respectively, for PMC on versus PMC off in the slow motion cases. The PMC system is a robust solution to decrease the motion sensitivity of multi-shot 3D EPI sequences and thereby overcome one of the main roadblocks to their widespread use in fMRI studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To identify the clinical determinants of occurrence of postictal generalized EEG suppression (PGES) after generalized convulsive seizures (GCS). METHODS: We reviewed the video-EEG recordings of 417 patients included in the REPO2MSE study, a multicenter prospective cohort study of patients with drug-resistant focal epilepsy. According to ictal semiology, we classified GCS into 3 types: tonic-clonic GCS with bilateral and symmetric tonic arm extension (type 1), clonic GCS without tonic arm extension or flexion (type 2), and GCS with unilateral or asymmetric tonic arm extension or flexion (type 3). Association between PGES and person-specific or seizure-specific variables was analyzed after correction for individual effects and the varying number of seizures. RESULTS: A total of 99 GCS in 69 patients were included. Occurrence of PGES was independently associated with GCS type (p < 0.001) and lack of early administration of oxygen (p < 0.001). Odds ratio (OR) for GCS type 1 in comparison with GCS type 2 was 66.0 (95% confidence interval [CI 5.4-801.6]). In GCS type 1, risk of PGES was significantly increased when the seizure occurred during sleep (OR 5.0, 95% CI 1.2-20.9) and when oxygen was not administered early (OR 13.4, 95% CI 3.2-55.9). CONCLUSION: The risk of PGES dramatically varied as a function of GCS semiologic characteristics. Whatever the type of GCS, occurrence of PGES was prevented by early administration of oxygen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The goal of the present study was to use a three-dimensional (3D) gradient echo volume in combination with a fat-selective excitation as a 3D motion navigator (3D FatNav) for retrospective correction of microscopic head motion during high-resolution 3D structural scans of extended duration. The fat excitation leads to a 3D image that is itself sparse, allowing high parallel imaging acceleration factors - with the additional advantage of a minimal disturbance of the water signal used for the host sequence. METHODS: A 3D FatNav was inserted into two structural protocols: an inversion-prepared gradient echo at 0.33 × 0.33 × 1.00 mm resolution and a turbo spin echo at 600 μm isotropic resolution. RESULTS: Motion estimation was possible with high precision, allowing retrospective motion correction to yield clear improvements in image quality, especially in the conspicuity of very small blood vessels. CONCLUSION: The highly accelerated 3D FatNav allowed motion correction with noticeable improvements in image quality, even for head motion which was small compared with the voxel dimensions of the host sequence. Magn Reson Med 75:1030-1039, 2016. © 2015 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Despite progress in multidisciplinary treatment of esophageal cancer, oncologic esophagectomy is still the cornerstone of therapeutic strategies. Several scoring systems are used to predict postoperative morbidity, but in most cases they identify nonmodifiable parameters. The aim of this study was to identify potentially modifiable risk factors associated with complications after oncologic esophagectomy. METHODS: All consecutive patients with complete data sets undergoing oncologic esophagectomy in our department during 2001-2011 were included in this study. As potentially modifiable risk factors we assessed nutritional status depicted by body mass index (BMI) and preoperative serum albumin levels, excessive alcohol consumption, and active smoking. Postoperative complications were graded according to a validated 5-grade system. Univariate and multivariate analyses were used to identify preoperative risk factors associated with the occurrence and severity of complications. RESULTS: Our series included 93 patients. Overall morbidity rate was 81 % (n = 75), with 56 % (n = 52) minor complications and 18 % (n = 17) major complications. Active smoking and excessive alcohol consumption were associated with the occurrence of severe complications, whereas BMI and low preoperative albumin levels were not. The simultaneous presence of two or more of these risk factors significantly increased the risk of postoperative complications. CONCLUSIONS: A combination of malnutrition, active smoking and alcohol consumption were found to have a negative impact on postoperative morbidity rates. Therefore, preoperative smoking and alcohol cessation counseling and monitoring and improving the nutritional status are strongly recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cone-beam computed tomography (CBCT) image-guided radiotherapy (IGRT) systems are widely used tools to verify and correct the target position before each fraction, allowing to maximize treatment accuracy and precision. In this study, we evaluate automatic three-dimensional intensity-based rigid registration (RR) methods for prostate setup correction using CBCT scans and study the impact of rectal distension on registration quality. METHODS: We retrospectively analyzed 115 CBCT scans of 10 prostate patients. CT-to-CBCT registration was performed using (a) global RR, (b) bony RR, or (c) bony RR refined by a local prostate RR using the CT clinical target volume (CTV) expanded with 1-to-20-mm varying margins. After propagation of the manual CT contours, automatic CBCT contours were generated. For evaluation, a radiation oncologist manually delineated the CTV on the CBCT scans. The propagated and manual CBCT contours were compared using the Dice similarity and a measure based on the bidirectional local distance (BLD). We also conducted a blind visual assessment of the quality of the propagated segmentations. Moreover, we automatically quantified rectal distension between the CT and CBCT scans without using the manual CBCT contours and we investigated its correlation with the registration failures. To improve the registration quality, the air in the rectum was replaced with soft tissue using a filter. The results with and without filtering were compared. RESULTS: The statistical analysis of the Dice coefficients and the BLD values resulted in highly significant differences (p<10(-6)) for the 5-mm and 8-mm local RRs vs the global, bony and 1-mm local RRs. The 8-mm local RR provided the best compromise between accuracy and robustness (Dice median of 0.814 and 97% of success with filtering the air in the rectum). We observed that all failures were due to high rectal distension. Moreover, the visual assessment confirmed the superiority of the 8-mm local RR over the bony RR. CONCLUSION: The most successful CT-to-CBCT RR method proved to be the 8-mm local RR. We have shown the correlation between its registration failures and rectal distension. Furthermore, we have provided a simple (easily applicable in routine) and automatic method to quantify rectal distension and to predict registration failure using only the manual CT contours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les virus exploitent la machinerie cellulaire de l'hôte pour se répliquer. Ils doivent s'adapter pour infecter la cellule hôte de manière optimale tout en échappant à la vigilance du système de défense de l'hôte. Ainsi l'hôte et les virus se livrent à de constantes batailles évolutives. Mon travail de thèse a porté sur l'étude des signatures évolutives de facteurs de l'hôte agissant comme des 'facteurs de restriction' en bloquant la réplication rétrovirale chez les primates. Plus spécifiquement, mon travail a visé à utiliser des données évolutives pour renseigner les analyses fonctionnelles et la biologie. Nous avons étudié le facteur anti-VIH-1 nommé TRIM5a (i) chez les prosimiens pour mieux comprendre son rôle dans le contrôle d'un lentivirus endogène, (ii) dans son activité contre d'autres anciennes infections représentées par des rétrovirus endogènes humains et (iii) en tant que protéine capable de générer des mutants de la capside. Premièrement nous nous sommes intéressés à TRIM5a chez deux espèces de lémuriens dont Microcebus murinus qui porte le lentivirus endogène PSIV dans son génome depuis plusieurs millions d'années,. Nous avons observé que TRIM5a chez M. murinus a un spectre d'activité antivirale réduit à l'opposé de TRIM5a chez le Lemur catta - non porteur du PSIV endogène - qui bloque une large variété de rétrovirus dont le PSIV. De ce fait TRIM5a aurait pu contribuer à protéger certaines espèces de lémuriens vis-à-vis d'anciennes infections par le PSIV. A l'inverse du PSIV, des virus dérivés des rétrovirus endogènes humains HERV-K and HERV-H se sont révélés largement résistants à l'inhibition par TRIM5a. Ces données illustrent une absence de protection par TRIM5a face à d'autres anciennes infections rétrovirales. Puis, pour évaluer l'impact de la protéine TRIM5a humaine sur le VIH-1, nous avons testé l'effet de mutations des résidues sous sélection positive dans la capside du VIH-1 sur l'inhibition par TRIM5a. Nos résultats montrent que TRIM5a ne jouerait pas un rôle significatif dans l'évolution de la capside du VIH-1. Enfin notre travail a porté sur le facteur anti-VIH-1 SAMHD1 récemment découvert, que nous avons séquencé chez 25 espèces de primates. L'analyse évolutive des sites sous sélection positive et des expériences fonctionnelles ont permis d'identifier le domaine de SAMHD1 interagissant avec la protéine lentivirale Vpx. De même que d'autres protéines virales contrecarrent les facteurs de restriction en les menant à la dégradation, nous avons observé que Vpx induit la dégradation de SAMHD1 de manière spécifique à l'espèce. Ces découvertes contribuent à comprendre comment les facteurs de restriction et les virus co-évoluent pour se neutraliser l'un l'autre. - Viruses hijack the host cellular machinery to replicate. They adapt to infect optimally host cells while escaping host defense systems. Viruses and the host coevolve in an evolutionary struggle. My thesis work has been devoted to study the evolutionary signatures of host factors acting as restriction factors that block retroviral replication in primates. Specifically, my work aimed at using evolutionary data to inform functional analyses and biology. We studied the anti-HIV-1 factor TRIM5a (i) in prosimians to better understand its possible role in the control of an endogenous lentivirus, (ii) in its activity against other ancient infections - as represented by HERVs, and (iii) as a protein capable of generating escape mutants in the viral capsid. First, my work focused on two lemur species, one of which was the gray mouse lemur that carries the endogenous lentivirus PSIV integrated in its genome for several million years. TRIM5a from gray mouse lemur exhibited a limited antiviral spectrum as opposed to TRIM5a from ring-tailed lemur - not a host of PSIV - that is able to block diverse retroviruses notably PSIV. These results support the possible contribution of TRIM5a in protecting lemur species from ancient infection by PSIV. In contrast, chimeric viruses derived from two human endogenous retroviruses were broadly resistant to TRIM5a-mediated restriction, suggesting TRIM5a lack of activity against other types of ancient infections. To evaluate the recent impact of human TRIM5a on HIV-1 evolution, we tested whether variants at positively selected sites in the HIV-1 capsid affected the ability of human TRIM5a alleles to restrict HIV-1. Our results indicate that TRIM5a does not play a significant role in the evolution of HIV1 capsid. At last, our work concentrated on the newly discovered anti-HIV-1 restriction factor SAMHD1. We determined its coding sequence in a panel of 25 species of primates. Evolutionary analyses of positively selected sites in SAMHD1 domains and functional assays identified the domain of SAMHD1 interacting with the lentiviral protein Vpx. Similar to other viral countermeasures targeting cellular restriction factors, Vpx was responsible of the degradation of SAMHD1 orthologs in a species-specific manner. These findings contributed to understanding how restriction factors and viruses evolve to counteract each other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While genetic polymorphisms play a paramount role in tuberculosis (TB), less is known about their contribution to the severity of diseases caused by other intracellular bacteria and fastidious microorganisms. We searched electronic databases for observational studies reporting on host factors and genetic predisposition to infections caused by intracellular fastidious bacteria published up to 30 May 2014. The contribution of genetic polymorphisms was documented for TB. This includes genetic defects in the mononuclear phagocyte/T helper cell type 1 (Th1) pathway contributing to disseminated TB disease in children and genome-wide linkage analysis (GWAS) in reactivated pulmonary TB in adults. Similarly, experimental studies supported the role of host genetic factors in the clinical presentation of illnesses resulting from other fastidious intracellular bacteria. These include IL-6 -174G/C or low mannose-binding (MBL) polymorphisms, which are incriminated in chronic pulmonary conditions triggered by C. pneumoniae, type 2-like cytokine secretion polymorphisms, which are correlated with various clinical patterns of M. pneumoniae infections, and genetic variation in the NOD2 gene, which is an indicator of tubal pathology resulting from Chamydia trachomatis infections. Monocyte/macrophage migration and T lymphocyte recruitment defects are corroborated to ineffective granuloma formation observed among patients with chronic Q fever. Similar genetic polymorphisms have also been suggested for infections caused by T. whipplei although not confirmed yet. In conclusion, this review supports the paramount role of genetic factors in clinical presentations and severity of infections caused by intracellular fastidious bacteria. Genetic predisposition should be further explored through such as exome sequencing.