26 resultados para corner detector

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Posterolateral corner (PLC) injuries of the knee are uncommon injury patterns that may result in significant degrees of functional disability. When surgery is necessary to address this injury a good knowledge of anatomy and a good surgical exposure is the mainstay. This report reviews the complex anatomy of the posterolateral corner (PLC) of knee and describes the osteotomy of Gerdy tubercle as a technical variant to approach this anatomical region. This surgical step allowing a good mobilisation of the multiple layers of ilio-tibial tract from distal to proximal makes an excellent exposure of the PLC structures with absence of morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to compare two methods used for determining the proper shielding of computed tomography (CT) rooms while considering recent technological advances in CT scanners. The approaches of the German Institute for Standardisation and the US National Council on Radiation Protection and Measurements were compared and a series of radiation measurements were performed in several CT rooms at the Lausanne University Hospital. The following three-step procedure is proposed for assuring sufficient shielding of rooms hosting new CT units with spiral mode acquisition and various X-ray beam collimation widths: (1) calculate the ambient equivalent dose for a representative average weekly dose length product at the position where shielding is required; (2) from the maximum permissible weekly dose at the location of interest, calculate the transmission factor F that must be taken to ensure proper shielding and (3) convert the transmission factor into a thickness of lead shielding. A similar approach could be adopted to use when designing shielding for fluoroscopy rooms, where the basic quantity would be the dose area product instead of the load of current (milliampere-minute).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Mesures de l'aorte ascendante par scanner synchronisé au rythme cardiaque: une étude pilote pour établir des valeurs normatives dans le cadre des futures thérapies par transcathéter. Objectif : L'objectif de cette étude est d'établir les valeurs morphométriques normatives de l'aorte ascendante à l'aide de l'angiographie par scanner synchronisé au rythme cardiaque, afin d'aider au développement des futurs traitements par transcathéter. Matériels et méthodes : Chez soixante-dix-sept patients (âgé de 22 à 83 ans, âge moyen: 54,7 ans), une angiographie par scanner synchronisé au rythme cardiaque a été réalisée pour évaluation des vaisseaux coronaires. Les examens ont été revus afin d'étudier l'anatomie de la chambre de chasse du ventricule gauche jusqu'au tronc brachio-céphalique droit. A l'aide de programmes de reconstructions multiplanaires et de segmentation automatique, différents diamètres et longueurs considérés comme importants pour les futurs traitements par transcathéter ont été mesurés. Les valeurs sont exprimées en moyennes, médianes, maximums, minimums, écart-types et en coefficients de variation. Les variations de diamètre de l'aorte ascendante durant le cycle cardiaque ont été aussi considérées. Résultats : Le diamètre moyen de la chambre de chasse du ventricule gauche était de 20.3+/-3.4 mm. Au niveau du sinus coronaire de l'aorte, il était de 34.2+/-4.1 mm et au niveau de la jonction sinotubulaire il était de 29.7+/-3.4 mm. Le diamètre moyen de l'aorte ascendante était de 32.7+/-3.8 mm. Le coefficient de variation de ces mesures variait de 12 à 17%. La distance moyenne entre l'insertion proximale des valvules aortiques et le départ du tronc brachio-céphalique droit était de 92.6+/-11.8 mm. La distance moyenne entre l'insertion proximale des valvules aortiques et l'origine de l'artère coronaire proximale était de 12.1+/-3.7 mm avec un coefficient de variation de 31%. La distance moyenne entre les deux ostia coronaires était de 7.2+/-3.1 mm avec un coefficient de variation de 43%. La longueur moyenne du petit arc de l'aorte ascendante entre l'artère coronaire gauche et le tronc brachio-céphalique droit était de 52.9+/-9.5 mm. La longueur moyenne de la continuité fibreuse entre la valve aortique et la valvule mitrale antérieure était de 14.6+/-3.3 mm avec un coefficient de variation de 23%. L'aire moyenne de la valve aortique était de 582.0+/-131.9 mm2. La variation du diamètre antéro-postérieur et transverse de l'aorte ascendante était respectivement de 8.4% et de 7.3%. Conclusion Il existe d'importantes variations inter-individuelles dans les mesures de l'aorte ascendante avec cependant des variations intra-individuelles faibles durant le cycle cardiaque. De ce fait, une approche personnalisée pour chaque patient est recommandée dans la confection des futures endoprothèses de l'aorte ascendante. Le scanner synchronisé au rythme cardiaque jouera un rôle prépondérant dans le bilan préthérapeutique. Abstract : The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3+/-3.4, coronary sinus 34.2+/-4.1, sinotubular junction 29.7+-3.4 and mid ascending aorta 32.7+/-3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6111.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1+/-3.7, and between both coronary ostia 7.2+/-3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 X9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.óf3.3, CV 13-43%. Mean aortic valve area was 582+-131.9 mm2. The variations of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The history of the opening seaway from the westernmost Tethys to the Central Atlantic is traced by the analysis of the sedimentary facies development in the external Rif basin of Northern Morocco and the geological and seismic data from the Moroccan Atlantic continental margin. In the Rif basin, after the early Sinemurian, sedimentary facies dated by ammonites, foraminifers and brachiopods, indicate a progression of rapid subsidence resulting from extensional tectonic (tilted blocks, escarpment fault breccias, neptunian dykes etc.) from the N and NE to the S and SW. From the Toarcian to the Bajocian, deltas progress from the W and SW into the `'Rides sud-rifaines'' realm. From the late Bathonian to the Oxfordian, deep-sea fans develop in the external Rif. During the same period, deltaic sediments fill in the Middle Atlas basin of Eastern Morocco and progress into the external Rif. The top of the Jurassic is characterised by carbonate deposits. At the northwestern corner of Africa, the subsidence of the sedimentary basins by rifting is initiated in the late Triassic; however, at the Mazagan transect of the Atlantic continental margin, the tectonic pattern characteristic of a passive continental margin appears clearly only in the early Jurassic. At the foot of the Mazagan escarpment, the sedimentary record shows a foundering of the first bloc during early to middle Lias. A thermal uplift phase is indicated by emersion of the African margin shoulder in late Liassic, and thermal relaxation starts in the middle Jurassic. The morphology of this transect, compared with the conjugate side of the American continent is most easily explained by the uniform sense simple shear model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this article was to review the strategies to control patient dose in adult and pediatric computed tomography (CT), taking into account the change of technology from single-detector row CT to multi-detector row CT. First the relationships between computed tomography dose index, dose length product, and effective dose in adult and pediatric CT are revised, along with the diagnostic reference level concept. Then the effect of image noise as a function of volume computed tomography dose index, reconstructed slice thickness, and the size of the patient are described. Finally, the potential of tube current modulation CT is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A key feature of memory processes is to link different input signals by association and to preserve this coupling at the level of synaptic connections. Late-phase long-term potentiation (L-LTP), a form of synaptic plasticity thought to encode long-term memory, requires gene transcription and protein synthesis. In this study, we report that a recently cloned coactivator of cAMP-response element-binding protein (CREB), called transducer of regulated CREB activity 1 (TORC1), contributes to this process by sensing the coincidence of calcium and cAMP signals in neurons and by converting it into a transcriptional response that leads to the synthesis of factors required for enhanced synaptic transmission. We provide evidence that TORC1 is involved in L-LTP maintenance at the Schaffer collateral-CA1 synapses in the hippocampus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drosophila avoid food contaminated by pathogenic bacteria and fungi using an olfactory pathway that is exquisitely tuned to a single microbial odour.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3 +/- 3.4, coronary sinus 34.2 +/- 4.1, sino-tubular junction 29.7 +/- 3.4 and mid ascending aorta 32.7 +/- 3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6 +/- 11.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1 +/- 3.7, and between both coronary ostia 7.2 +/- 3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 +/- 9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.6 +/- 3.3, CV 13-43%. Mean aortic valve area was 582.0 +/- 131.9 mm(2). The variation of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.