54 resultados para conforming mesh
em Université de Lausanne, Switzerland
Resumo:
OBJECTIVE: : To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN: : In vitro, laboratory study. SETTING: : Research laboratory of a university hospital. INTERVENTIONS: : Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested in three nebulization modes in a nonhumidified bench model mimicking the ventilatory pattern of a 10-kg infant. The amounts of albuterol deposited on the inspiratory filters (inhaled drug) at the end of the endotracheal tube, on the expiratory filters, and remaining in the nebulizers or in the ventilator circuit were determined. Particle size distribution of the nebulizers was also measured. MEASUREMENTS AND MAIN RESULTS: : The inhaled drug was 2.8% ± 0.5% for the jet nebulizer, 10.5% ± 2.3% for the ultrasonic nebulizer, and 5.4% ± 2.7% for the vibrating-mesh nebulizer in intermittent nebulization during the inspiratory phase (p < 0.01). The most efficient nebulizer was the vibrating-mesh nebulizer in continuous nebulization (13.3% ± 4.6%, p < 0.01). Depending on the nebulizers, a variable but important part of albuterol was observed as remaining in the nebulizers (jet and ultrasonic nebulizers), or being expired or lost in the ventilator circuit (all nebulizers). Only small particles (range 2.39-2.70 µm) reached the end of the endotracheal tube. CONCLUSIONS: : Important differences between nebulizer types and nebulization modes were seen for albuterol deposition at the end of the endotracheal tube in an in vitro pediatric ventilator-lung model. New aerosol devices, such as ultrasonic and vibrating-mesh nebulizers, were more efficient than the jet nebulizer.
Resumo:
Fibrin sealing has recently evolved as a new technique for mesh fixation in endoscopic inguinal hernia repair. A comprehensive Medline search was carried out evaluating fibrin sealant for mesh fixation, and finally 12 studies were included (3 randomized trials, 3 nonrandomized trials, and 6 case series). The trials were assessed for operative time, seroma formation, recovery time, recurrence rate, and acute and chronic pain.There was a trend toward decreased operative times for fibrin sealing compared with mechanical stapling; however, the results for seroma formation remained contradictory. The most important finding was the reduced postoperative pain. Recovery times were lower after fibrin sealing and the recurrence rates showed no differences.Fibrin sealing for mesh fixation in the endoscopic inguinal hernia surgery is a promising alternative to mechanical stapling, which can be safely applied. As the overall quality of published data remains poor, further well-designed studies are needed until fibrin sealing can replace mechanical stapling as a new standard for mesh fixation.
Resumo:
BACKGROUND: Incarcerated hernias represent about 5-15 % of all operated hernias. Tension-free mesh is the preferred technique for elective surgery due to low recurrence rates. There is however currently no consensus on the use of mesh for the treatment of incarcerated hernias, especially in case of bowel resection. AIM: The aims of this study were (i) to report our current practice for the treatment of incarcerated hernias, (ii) to identify risk factors for postoperative complications, and (iii) to assess the safety of mesh placement in potentially infected surgical fields. METHODS: This retrospective study included 166 consecutive patients who underwent emergency surgery for incarcerated hernia between January 2007 and January 2012 in two university hospitals. Demographics, surgical details, and short-term outcome were collected. Univariate analysis was employed to identify risk factors for overall, infectious, and major complications. RESULTS: Eighty-four patients (50.6 %) presented inguinal hernias, 43 femoral (25.9 %), 37 umbilical hernias (22.3 %), and 2 mixed hernias (1.2 %), respectively. Mesh was placed in 64 patients (38.5 %), including 5 patients with concomitant bowel resection. Overall morbidity occurred in 56 patients (32.7 %), and 8 patients (4.8 %) developed surgical site infections (SSI). Univariate risk factors for overall complications were ASA grade 3/4 (P = 0.03), diabetes (P = 0.05), cardiopathy (P = 0.001), aspirin use (P = 0.023), and bowel resection (P = 0.001) which was also the only identified risk factor for SSI (P = 0.03). In multivariate analysis, only bowel incarceration was associated with a higher rate of major morbidity (OR = 14.04; P = 0.01). CONCLUSION: Morbidity after surgery for incarcerated hernia remains high and depends on comorbidities and surgical presentation. The use of mesh could become current practice even in case of bowel resection.
Resumo:
Context: In the past 50 years, the use of prosthetic mesh in surgery has dramatically¦changed the management of primary, as well as incisional hernias. Currently, there¦are a large number of different mesh brands and no consensus on the best material,¦nor the best mesh implantation technique to use. The purpose of this study is to¦illustrate the adverse effects of intraperitoneal onlay mesh used for incisional¦hernia repair encountered in patients treated at CHUV for complications after¦incisional hernia repair.¦Materials & Methods: This work is an observational retrospective study. A PubMed¦search and a systematic review of literature were performed. Thereafter, the medical¦records of 22 patients who presented with pain, abdominal discomfort, ileus, fistula,¦abscess, seroma, mesh infection or recurrent incisional hernia after a laparoscopic or¦open repair with intra-abdominal mesh were reviewed.¦Results: Twenty-two persons were reoperated for complications after incisional¦hernia repair with a prosthetic mesh. Ten were male and twelve female, with a¦median age of 58,6 years (range 24-82). Mesh placement was performed by a¦laparoscopic approach in nine patients and by open approach in thirteen others.¦Eight different mesh brands were found (Ultrapro®, Mersilene®, Parietex Composite®,¦Proceed®, DynaMesh®, Gore® DualMesh®, Permacol®, Titanium Metals UK Ltd®).¦Mean time from implantation and reoperation for complication was 34.2 months¦(range 1-147). In our sample of 22 patients, 21 (96%) presented mesh adhesion and¦15 (68%) presented hernia recurrence. Others complications like mesh shrinkage,¦mesh migration, nerve entrapment, seroma, fistula and abscess were also evaluated.¦Conclusion: The majority of articles deal with complications induced by¦intraperitoneal prosthetic mesh, but the effectiveness of mesh has been studied¦mostly on experimental models. Actually and as shown in the present study,¦intraperitoneal mesh placement was associated with severe complications witch may¦potentially be life threatening. In our opinion, intraperitoneal mesh placement should¦only be reserved in exceptional situations, when the modified Rives-Stoppa could not¦be achieved and when tissues covering the mesh are insufficient.
Resumo:
Totally extraperitoneal laparoscopic hernia repair is an efficient but technically demanding procedure. As mechanisms of hernia recurrence may be related to these technical difficulties, we have modified a previously described double-mesh technique in an effort to simplify the procedure. Extraperitoneal laparoscopic hernia repairs were performed in 82 male and 17 female patients having inguinal, femoral, and recurrent bilateral hernias. A standard propylene mesh measuring 15 x 15 cm was cut into two pieces of 4 x 15 cm and 11 x 15 cm. The smaller mesh was placed over both inguinal rings without splitting. The larger mesh was then inserted over the first mesh and stapled to low-risk zones, reinforcing the large-vessel area and the nerve transition zone. The mean procedure duration was 60 minutes for unilateral and 100 minutes for bilateral hernia repair. Patients were discharged from the hospital within 48 hours. The mean postoperative follow-up was 22 months, with no recurrences, neuralgia, or bleeding complications. Over a 2-year period, this technique was found to be satisfactory without recurrences or significant complications. In our hands, this technique was easier to perform: it allows for a less than perfect positioning of the meshes and avoids most of the stapling to crucial zones.
Resumo:
The aim of this study was to prospectively evaluate the accuracy and predictability of new three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction.We analyzed the preoperative and postoperative clinical and radiologic data of 10 patients with isolated blow-out orbital fractures. Fracture locations were as follows: floor (N = 7; 70%), medial wall (N = 1; 1%), and floor/medial wall (N = 2; 2%). The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures. A three-dimensional preformed AO titanium mesh plate (0.4 mm in thickness) was selected according to the size of the defect previously measured on the preoperative computed tomographic (CT) scan examination and fixed at the inferior orbital rim with 1 or 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative CT scan. Coronal CT scan slices were used to measure bony orbital volume using OsiriX Medical Image software. Reconstructed versus uninjured orbital volume were statistically correlated.Nine patients (90%) had a successful treatment outcome without complications. One patient (10%) developed a mechanical limitation of upward gaze with a resulting handicapping diplopia requiring hardware removal. Postoperative orbital CT scan showed an anatomic three-dimensional placement of the orbital mesh plates in all of the patients. Volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 2.5 cm(3). There was no significant difference in volume between the reconstructed and uninjured orbits.This preliminary study has demonstrated that three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction results in (1) a high rate of success with an acceptable rate of major clinical complications (10%) and (2) an anatomic restoration of the bony orbital contour and volume that closely approximates that of the contralateral uninjured orbit.
Resumo:
PURPOSE: To prospectively evaluate the accuracy and reliability of "freehand" posttraumatic orbital wall reconstruction with AO (Arbeitsgemeinschaft Osteosynthese) titanium mesh plates by using computer-aided volumetric measurement of the bony orbits. METHODS: Bony orbital volume was measured in 12 patients from coronal CT scan slices using OsiriX Medical Image software. After defining the volumetric limits of the orbit, the segmentation of the bony orbital region of interest of each single slice was performed. At the end of the segmentation process, all regions of interest were grouped and the volume was computed. The same procedure was performed on both orbits, and thereafter the volume of the contralateral uninjured orbit was used as a control for comparison. RESULTS: In all patients, the volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 1.85 cm3 (7%). CONCLUSIONS: This preliminary study has demonstrated that posttraumatic orbital wall reconstruction using "freehand" bending and placement of AO titanium mesh plates results in a high success rate in re-establishing preoperative bony volume, which closely approximates that of the contralateral uninjured orbit.
Resumo:
The Editors welcome topical correspondence from readers relating to articles published in the Journal. Responses should be sent electronically via the BJS website (www.bjs.co.uk). All letters will be reviewed and, if approved, appear on the website. A selection of these will be edited and published in the Journal. Letters must be no more than 250 words in length.
Resumo:
The saphenous vein is the conduit of choice in bypass graft procedures. Haemodynamic factors play a major role in the development of intimal hyperplasia (IH), and subsequent bypass failure. To evaluate the potential protective effect of external reinforcement on such a failure, we developed an ex vivo model for the perfusion of segments of human saphenous veins under arterial shear stress. In veins submitted to pulsatile high pressure (mean pressure at 100 mmHg) for 3 or 7 days, the use of an external macroporous polyester mesh 1) prevented the dilatation of the vessel, 2) decreased the development of IH, 3) reduced the apoptosis of smooth muscle cells, and the subsequent fibrosis of the media layer, 4) prevented the remodelling of extracellular matrix through the up-regulation of matrix metalloproteinases (MMP-2, MMP-9) and plasminogen activator type I. The data show that, in an experimental ex vivo setting, an external scaffold decreases IH and maintains the integrity of veins exposed to arterial pressure, via increase in shear stress and decrease wall tension, that likely contribute to trigger selective molecular and cellular changes.
Resumo:
A consecutive series of 353 patients who underwent Lichtenstein mesh repair for inguinal hernia from the 1st of July 1994 to the 30th of July 1995 were studied. We analysed our indication, technique, complications, follow-up and outcome. Special consideration was given to the advantages and acceptance of day-case surgery. Our results suggest that the Lichtenstein repair should be considered as a new standard procedure, especially outside of hernia centres.
Resumo:
In this paper we propose a stabilized conforming finite volume element method for the Stokes equations. On stating the convergence of the method, optimal a priori error estimates in different norms are obtained by establishing the adequate connection between the finite volume and stabilized finite element formulations. A superconvergence result is also derived by using a postprocessing projection method. In particular, the stabilization of the continuous lowest equal order pair finite volume element discretization is achieved by enriching the velocity space with local functions that do not necessarily vanish on the element boundaries. Finally, some numerical experiments that confirm the predicted behavior of the method are provided.
Resumo:
Objective: Standard treatment of locally advanced (stages III and IV A-B) nasopharyngeal carcinoma (NPC) consists in chemoradiotherapy with 5-y survival rates of around 60%. However, acute toxicity prevents the administration of adequate adjuvant chemotherapy in nearly half of the patients. This situation has led to the hypothesis that induction chemotherapy followed by chemoradiotherapy may be a superior approach. Many ongoing studies are testing the role of induction chemotherapy in this setting. Newer radiotherapy techniques are becoming available (intensity modulated radiotherapy [IMRT] and tomotherapy). They can achieve a higher degree of accuracy in conforming the radiation to the planned target volume while sparing normal tissue resulting in less acute and long-term toxicity. Methods: We report here our local experience of 11 consecutive locally advanced NPC patients treated between June 2004 and October 2007. Median age was 46 years (range, 17-65). All but one were male patients. Initial stage was stage III in 5, and stage IVA-B in 6 patients. Treatment consisted of 3 cycles of induction TCF (Docetaxel 75 mg/m2- Cisplatin 75 mg/m2- 5-fluorouracil 750 mg/m2/d 5 days) chemotherapy followed by concomitant chemoradiotherapy with 3 cycles of cisplatin (100 mg/m2), or carboplatin (AUC 5) in case of renal impairment. Radiotherapy was delivered by either IMRT or tomotherapy. Macroscopic disease (tumor + involved lymph nodes) was treated with 70 Gy, 2 Gy/fraction (IMRT), or 69.6 Gy, 1.12 Gy/fraction (simultaneus integrated boost [SIB] technique). Elective nodal irradiation of 46-54 Gy lymph was performed in all patients, whereas elective irradiation of the entire nasopharynx (60 Gy) half of patients. Results: All but one tumor were EBV positive. Induction chemotherapy was done as planned for 8 patients (73%). Two patients had only 2 cycles, 1 patient had only1 cycle of TCF, and the other without docetaxel. Concomitant chemotherapy was given as planned in 7 patients (64%). Four patients had only 2 cycles. Radiotherapy could be delivered as planned in all patients. Eight weeks post treatment all patients proved to have a CR (CR or uCR). After a median follow-up of 11 months (range, 6-38 months) only one patient has relapsed. Details on acute and 1 year toxicities will be presented. Conclusion: Treatment of locally advancedNPC with induction and concomitant chemotherapy is feasible and well tolerated. The use of IMRT or tomotherapy technique seems to ameliorate the therapeutic index particularly in regard with xerostomia. All our patients presented a complete response. For the assessment of survival and long-term toxicity, a longer follow-up period is needed.
Resumo:
Recent technological advances in remote sensing have enabled investigation of the morphodynamics and hydrodynamics of large rivers. However, measuring topography and flow in these very large rivers is time consuming and thus often constrains the spatial resolution and reach-length scales that can be monitored. Similar constraints exist for computational fluid dynamics (CFD) studies of large rivers, requiring maximization of mesh-or grid-cell dimensions and implying a reduction in the representation of bedform-roughness elements that are of the order of a model grid cell or less, even if they are represented in available topographic data. These ``subgrid'' elements must be parameterized, and this paper applies and considers the impact of roughness-length treatments that include the effect of bed roughness due to ``unmeasured'' topography. CFD predictions were found to be sensitive to the roughness-length specification. Model optimization was based on acoustic Doppler current profiler measurements and estimates of the water surface slope for a variety of roughness lengths. This proved difficult as the metrics used to assess optimal model performance diverged due to the effects of large bedforms that are not well parameterized in roughness-length treatments. However, the general spatial flow patterns are effectively predicted by the model. Changes in roughness length were shown to have a major impact upon flow routing at the channel scale. The results also indicate an absence of secondary flow circulation cells in the reached studied, and suggest simpler two-dimensional models may have great utility in the investigation of flow within large rivers. Citation: Sandbach, S. D. et al. (2012), Application of a roughness-length representation to parameterize energy loss in 3-D numerical simulations of large rivers, Water Resour. Res., 48, W12501, doi: 10.1029/2011WR011284.
Resumo:
BACKGROUND: Chronic neuropathy after hernia repair is a neglected problem as very few patients are referred for surgical treatment. The aim of the present study was to assess the outcome of standardized surgical revision for neuropathic pain after hernia repair. METHODS: In a prospective cohort study we evaluated all patients admitted to our tertiary referral center for surgical treatment of persistent neuropathic pain after primary herniorrhaphy between 2001 and 2006. Diagnosis of neuropathic pain was based on clinical findings and a positive Tinel's sign. Postoperative pain was evaluated by a visual analogue scale (VAS) and a pain questionnaire up to 12 months after revision surgery. RESULTS: Forty-three consecutive patients (39 male, median age 35 years) underwent surgical revision, mesh removal, and radical neurectomy. The median operative time was 58 min (range: 45-95 min). Histological examination revealed nerve entrapment, complete transection, or traumatic neuroma in all patients. The ilioinguinal nerve was affected in 35 patients (81%); the iliohypogastric nerve, in 10 patients (23%). Overall pain (median VAS) decreased permanently after surgery within a follow-up period of 12 months (preoperative 74 [range: 53-87] months versus 0 [range: 0-34] months; p<0.0001). CONCLUSIONS: The results of this cohort study suggest that surgical mesh removal with ilioinguinal and iliohypogastric neurectomy is a successful treatment in patients with neuropathic pain after hernia repair.