36 resultados para chlorophyll fluorescence

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Furosemide (FD: Lasix) is a loop diuretic which strongly increases both urine flow and electrolyte urinary excretion. Healthy volunteers were administered 40 mg orally (dissolved in water) and concentrations of FD were determined in serum and urine for up to 6 h for eight subjects, who absorbed water at a rate of 400 ml/h. Quantification was performed by HPLC with fluorescence detection (excitation at 233 nm, emission at 389 nm) with a limit of detection of 5 ng/ml for a 300-microliters sample. The elution of FD was completed within 4 min using a gradient of acetonitrile concentration rising from 30 to 50% in 0.08 M phosphoric acid. The delay to the peak serum concentration ranged from 60 to 120 min. FD was still easily measurable in the sera from all subjects 6 h after administration. In urine, the excretion rates reached their maximum between 1 and 3 h. The total amount of FD excreted in the urine averaged 11.2 mg (range 7.6-14.0 mg), with a mean urine volume of 3024 ml (range 2620-3596 ml). Moreover, the urine density was lower than 1.010 (recommended as an upper limit in doping analysis to screen diuretics) only for 2 h. An additional volunteer was administered 40 mg of FD and his urine was collected over a longer period. FD was still detectable 48 h after intake. Gas chromatography-mass spectrometry with different types of ionization was used to confirm the occurrence of FD after permethylation of the extract. Negative-ion chemical ionization, with ammonia as reactant gas, was found to be the most sensitive method of detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a new method for lysis of single cells in continuous flow, where cells are sequentially trapped, lysed and released in an automatic process. Using optimized frequencies, dielectrophoretic trapping allows exposing cells in a reproducible way to high electrical fields for long durations, thereby giving good control on the lysis parameters. In situ evaluation of cytosol extraction on single cells has been studied for Chinese hamster ovary (CHO) cells through out-diffusion of fluorescent molecules for different voltage amplitudes. A diffusion model is proposed to correlate this out-diffusion to the total area of the created pores, which is dependent on the potential drop across the cell membrane and enables evaluation of the total pore area in the membrane. The dielectrophoretic trapping is no longer effective after lysis because of the reduced conductivity inside the cells, leading to cell release. The trapping time is linked to the time required for cytosol extraction and can thus provide additional validation of the effective cytosol extraction for non-fluorescent cells. Furthermore, the application of one single voltage for both trapping and lysis provides a fully automatic process including cell trapping, lysis, and release, allowing operating the device in continuous flow without human intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluorescence imaging for detection of non-muscle-invasive bladder cancer is based on the selective production and accumulation of fluorescing porphyrins-mainly, protoporphyrin IX-in cancerous tissues after the instillation of Hexvix®. Although the sensitivity of this procedure is very good, its specificity is somewhat limited due to fluorescence false-positive sites. Consequently, magnification cystoscopy has been investigated in order to discriminate false from true fluorescence positive findings. Both white-light and fluorescence modes are possible with the magnification cystoscope, allowing observation of the bladder wall with magnification ranging between 30à for standard observation and 650Ã. The optical zooming setup allows adjusting the magnification continuously in situ. In the high-magnification (HM) regime, the smallest diameter of the field of view is 600 microns and the resolution is 2.5 microns when in contact with the bladder wall. With this cystoscope, we characterized the superficial vascularization of the fluorescing sites in order to discriminate cancerous from noncancerous tissues. This procedure allowed us to establish a classification based on observed vascular patterns. Seventy-two patients subject to Hexvix® fluorescence cystoscopy were included in the study. Comparison of HM cystoscopy classification with histopathology results confirmed 32?33 (97%) cancerous biopsies and rejected 17?20 (85%) noncancerous lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free amino acids (AAs) in human plasma are derivatized with 3-(4-carboxybenzoyl)quinoline-2-carboxaldehyde (CBQCA) and analyzed by capillary electrophoresis (CE) with laser induced fluorescence (LIF) detection. The labeling procedure is significantly improved over results reported previously. Derivatization can be completed in 40 min, with concentrations as low as 4 x 10(-8) M successfully labeled in favourable cases. Twenty-nine AAs (including 2 internal standards) are identified and can be reproducibly separated in 70 min. Migration time RSD values for 23 of these AAs were calculated and found in the range from 0.5 to 4%. The rapid derivatization procedure and the resolution obtained in the separation are sufficient for a semi-quantitative, emergency diagnosis of several inborn errors of metabolism (IEM). Amino acid profiles for both normal donor plasma samples and plasma samples of patients suffering from phenylketonuria, tyrosinemia, maple syrup urinary disease, hyperornithinemia, and citrullinemia are studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During fluorescence cystoscopy, it is observed that the acquired images are sometimes blurred by a greenish background originating from the bladder washout fluid. Several fluorophores are involved in this overall liquid fluorescence, and their exact origin and relative contributions remain unknown. In this study, the bladder washout fluid is sampled at different times during fluorescence cystoscopy examinations. In total, 32 samples from 12 patients are analyzed with a spectrofluorimeter (excitation range: 350-445 nm, emission range 380-700 nm). This study shows clearly that the position of the fluorescence peaks (excitation/emission wavelengths: 450/525 nm, 405/625 nm) and shoulder (440/525 nm) is reproducible between different patients. It also suggests that an excitation at wavelengths higher than 400 nm helps to suppress this solution background fluorescence. Additionally, the pH of the solution seems to influence the position of the fluorescence peaks, and this suggests that changing the pH of the examination liquid could help in avoiding the greenish background.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a global approach combining fluorescence recovery after photobleaching (FRAP), fluorescence correlation spectroscopy (FCS), and fluorescence resonance energy transfer (FRET), we address the behavior in living cells of the peroxisome proliferator-activated receptors (PPARs), a family of nuclear receptors involved in lipid and glucose metabolism, inflammation control, and wound healing. We first demonstrate that unlike several other nuclear receptors, PPARs do not form speckles upon ligand activation. The subnuclear structures that may be observed under some experimental conditions result from overexpression of the protein and our immunolabeling experiments suggest that these structures are subjected to degradation by the proteasome. Interestingly and in contrast to a general assumption, PPARs readily heterodimerize with retinoid X receptor (RXR) in the absence of ligand in living cells. PPAR diffusion coefficients indicate that all the receptors are engaged in complexes of very high molecular masses and/or interact with relatively immobile nuclear components. PPARs are not immobilized by ligand binding. However, they exhibit a ligand-induced reduction of mobility, probably due to enhanced interactions with cofactors and/or chromatin. Our study draws attention to the limitations and pitfalls of fluorescent chimera imaging and demonstrates the usefulness of the combination of FCS, FRAP, and FRET to assess the behavior of nuclear receptors and their mode of action in living cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distinguishing subpopulations in group behavioral experiments can reveal the impact of differences in genetic, pharmacological and life-histories on social interactions and decision-making. Here we describe Fluorescence Behavioral Imaging (FBI), a toolkit that uses transgenic fluorescence to discriminate subpopulations, imaging hardware that simultaneously records behavior and fluorescence expression, and open-source software for automated, high-accuracy determination of genetic identity. Using FBI, we measure courtship partner choice in genetically mixed groups of Drosophila.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genetically engineered bioreporters are an excellent complement to traditional methods of chemical analysis. The application of fluorescence flow cytometry to detection of bioreporter response enables rapid and efficient characterization of bacterial bioreporter population response on a single-cell basis. In the present study, intrapopulation response variability was used to obtain higher analytical sensitivity and precision. We have analyzed flow cytometric data for an arsenic-sensitive bacterial bioreporter using an artificial neural network-based adaptive clustering approach (a single-layer perceptron model). Results for this approach are far superior to other methods that we have applied to this fluorescent bioreporter (e.g., the arsenic detection limit is 0.01 microM, substantially lower than for other detection methods/algorithms). The approach is highly efficient computationally and can be implemented on a real-time basis, thus having potential for future development of high-throughput screening applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: In bladder cancer, conventional white light endoscopic examination of the bladder does not provide adequate information about the presence of "flat" urothelial lesions such as carcinoma in situ. In the present investigation, we examine a new technique for the photodetection of such lesions by the imaging of protoporphyrin IX (PpIX) fluorescence following topical application of 5-aminolevulinic acid (ALA). STUDY DESIGN/MATERIALS AND METHODS: Several hours after bladder instillation of an aqueous solution of ALA in 34 patients, a Krypton ion laser or a filtered Xenon arc-lamp was used to excite PpIX fluorescence. Tissue samples for histological analysis were taken while observing the bladder wall either by means of a video camera, or by direct endoscopic observation. RESULTS: A good correlation was found between the PpIX fluorescence and the histopathological diagnosis. On a total of 215 biopsies, 143 in fluorescent and 72 in nonfluorescent areas, all visible tumors on white light cytoscopy appeared in a bright red fluorescence with the photodetection technique. In addition, this method permitted to discover 47 unsuspected carcinomatous lesions on white light observation, among which 40% were carcinoma in situ. CONCLUSION: PpIX fluorescence induced by instillation into the bladder of 5-ALA is an efficient method of mapping the mucosa in bladder carcinoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In high hyperdiploid acute lymphoblastic leukemia (ALL), the concurrence of specific trisomies confers a more favorable outcome than hyperdiploidy alone. Interphase fluorescence in situ hybridization (FISH) complements conventional cytogenetics (CC) through its sensitivity and ability to detect chromosome aberrations in nondividing cells. To overcome the limits of manual I-FISH, we developed an automated four-color I-FISH approach and assessed its ability to detect concurrent aneuploidies in ALL. I-FISH was performed using centromeric probes for chromosomes 4, 6, 10, and 17. Parameters established for nucleus selection and signal detection were evaluated. Cutoff values were determined. Combinations of aneuploidies were considered relevant when each aneuploidy was individually significant. Results obtained in 10 patient samples were compared with those obtained with CC. Various combinations of aneuploidies were identified. All clones detected by CC were observed also by I-FISH, and I-FISH revealed numerous additional abnormal clones in all patients, ranging from < or =1% to 31.6% of cells analyzed. We conclude that four-color automated I-FISH permits the identification of concurrent aneuploidies of potential prognostic significance. Large numbers of cells can be analyzed rapidly. The large number of nuclei scored revealed a high level of chromosome variability both at diagnosis and relapse, the prognostic significance of which is of considerable clinical interest and merits further evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluorescence cystoscopy enhances detection of early bladder cancer. Water used to inflate the bladder during the procedure rapidly contains urine, which may contain fluorochromes. This frequently degradesfluorescence images. Samples of bladder washout fluid (BWF) or urine were collected (15 subjects). We studiedtheir fluorescence properties and assessed changes induced by pH (4 to 9) and temperature (15°C to 41°C).A typical fluorescence spectrum of BWF features a main peak (excitation/emission: 320∕420 nm, FWHM =50∕100 nm) and a weaker (5% to 20% of main peak intensity), secondary peak (excitation/emission: 455∕525 nm, FWHM = 80∕50 nm). Interpatient fluctuations of fluorescence intensity are observed. Fluorescence intensity decreases when temperature increases (max 30%) or pH values vary (max 25%). Neither approach is compatible with clinical settings. Fluorescence lifetime measurements suggest that 4-pyridoxic acid/riboflavin is the most likely molecule responsible for urine's main/secondary fluorescence peak. Our measurements give an insight into the spectroscopy of the detrimental background fluorescence. This should be included in the optical design of fluorescence cystoscopes. We estimate that restricting the excitation range from 370-430 nm to 395-415 nm would reduce the BWF background by a factor 2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tetrasomy 8 constitutes a relatively rare recurring chromosome defect in myeloid disorders. The patient reported here, a 71-year-old man, presented with tetrasomy 8 as the sole chromosome abnormality associated with an acute nonlymphocytic leukemia of the M2 type. He failed to respond to chemotherapy and died one year after diagnosis. Following conventional cytogenetics and fluorescence in situ hybridization (FISH) with a centromeric probe specific for chromosome 8, tetrasomy 8 was detected in 61% of the metaphases analyzed and trisomy 8 in 39%. FISH analysis of interphase nuclei confirmed the existence of tetrasomic (35%) and trisomic cells (56%) and revealed a number of cells with two chromosomes 8 (8%). This normal population may represent lymphocytes or myeloid cells that escaped conventional analysis due to their inability to divide or to the small number of metaphases available. The relatively higher proportion of tetrasomic cells in metaphase compared with interphase may be attributed to a proliferative advantage of tetrasomic cells in vitro or to the longer duration of their cell cycle. The simultaneous presence of trisomic and tetrasomic cells confirms the hypothesis of a clonal relationship between trisomy 8 and tetrasomy 8. Our case brings further evidence to the specificity of tetrasomy 8 to myeloid disorders and to the association of this chromosome abnormality with a relatively poor prognosis. However, new patients must be studied to further delineate this cytogenetic entity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antibiotic-resistant pathogens are a major health concern in everyday clinical practice. Because their detection by conventional microbial techniques requires minimally 24 h, some of us have recently introduced a nanomechanical sensor, which can reveal motion at the nanoscale. By monitoring the fluctuations of the sensor, this technique can evidence the presence of bacteria and their susceptibility to antibiotics in less than 1 h. Their amplitude correlates to the metabolism of the bacteria and is a powerful tool to characterize these microorganisms at low densities. This technique is new and calls for an effort to optimize its protocol and determine its limits. Indeed, many questions remain unanswered, such as the detection limits or the correlation between the bacterial distribution on the sensor and the detection's output. In this work, we couple fluorescence microscopy to the nanomotion investigation to determine the optimal experimental protocols and to highlight the effect of the different bacterial distributions on the sensor.