73 resultados para chemically modified electrode
em Université de Lausanne, Switzerland
Resumo:
The tonoplast calcium Ca2+/H+ antiport system of maize (Zea mays L. cv LG 11) roots was characterized using the ''pH jump'' technique in order to avoid interference from the tonoplast proton and Ca2+ pumps. Ca2+ uptake was recorded in the presence of different inhibitors and divalent ions. Chemical modification of amino acid residues of the antiport was used to elucidate the amino acid residues participating in the Ca2+ transport activity. The Ca2+/H+ antiport activity was found to be strongly inhibited by ruthenium red and verapamil, whereas diethylstilbestrol was less effective. Vanadate, erythrosin B, cyclopiazonic acid, bafilomycin, thapsigargin, N,N'-dicyclohexylcarbodiimide (DCCD) and 4,4'-diisothiocyanatostilbene-2,2'-disulfonate (DIDS) were without effect. Lanthanum and divalent ions were strongly inhibitory (Cd2+ > Mn2+ > Sr2+ > Ba2+). While reagents modifying sulfhydryl groups (N-ethylmaleimide and 5,5'-dithio-bis(2-nitrobenzoate)) did not affect the antiport activity, modification of trytophan residues (N-bromosuccinimide) was strongly inhibitory. We conclude that ruthenium red, verapamil, lanthanum and divalent cations directly inhibit Ca2+ uptake independent of the function of the proton and Ca2+ pumps. Moreover, the results of chemically modified amino acid residues suggest that sulfhydryl groups are not involved in Ca2+ transport, while tryptophan residues seem important for this translocation.
Resumo:
DNA that survives in museum specimens, bones and other tissues recovered by archaeologists is invariably fragmented and chemically modified. The extent to which such modifications accumulate over time is largely unknown but could potentially be used to differentiate between endogenous old DNA and present-day DNA contaminating specimens and experiments. Here we examine mitochondrial DNA sequences from tissue remains that vary in age between 18 and 60,000 years with respect to three molecular features: fragment length, base composition at strand breaks, and apparent C to T substitutions. We find that fragment length does not decrease consistently over time and that strand breaks occur preferentially before purine residues by what may be at least two different molecular mechanisms that are not yet understood. In contrast, the frequency of apparent C to T substitutions towards the 5'-ends of molecules tends to increase over time. These nucleotide misincorporations are thus a useful tool to distinguish recent from ancient DNA sources in specimens that have not been subjected to unusual or harsh treatments.
Resumo:
BACKGROUND: Multiple electrode aggregometry (MEA) is a point-of-care test evaluating platelet function and the efficacy of platelet inhibitors. In MEA, electrical impedance of whole blood is measured after addition of a platelet activator. Reduced impedance implies platelet dysfunction or the presence of platelet inhibitors. MEA plays an increasingly important role in the management of perioperative platelet dysfunction. In vitro, midazolam, propofol, lidocaine and magnesium have known antiplatelet effects and these may interfere with MEA interpretation. OBJECTIVE: To evaluate the extent to which MEA is modified in the presence of these drugs. DESIGN: An in-vitro study using blood collected from healthy volunteers. SETTING: Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland, 2010 to 2011. PATIENTS: Twenty healthy volunteers. INTERVENTION: Measurement of baseline MEA was using four activators: arachidonic acid, ADP, TRAP-6 and collagen. The study drugs were then added in three increasing, clinically relevant concentrations. MAIN OUTCOME MEASURE: MEA was compared with baseline for each study drug. RESULTS: Midazolam, propofol and lidocaine showed no effect on MEA at any concentration. Magnesium at 2.5 mmol l had a significant effect on the ADP and TRAP tests (31 ± 13 and 96 ± 39 AU, versus 73 ± 21 and 133 ± 28 AU at baseline, respectively), and a less pronounced effect at 1 mmol l on the ADP test (39 ± 0 AU). CONCLUSION: Midazolam, propofol and lidocaine do not interfere with MEA measurement. In patients treated with high to normal doses of magnesium, MEA results for ADP and TRAP-tests should be interpreted with caution. TRIAL REGISTRATION: Clinicaltrials.gov (no. NCT01454427).
Resumo:
OBJECTIVE: To investigate the association of renal impairment on functional outcome and complications in stroke patients treated with IV thrombolysis (IVT). METHODS: In this observational study, we compared the estimated glomerular filtration rate (GFR) with poor 3-month outcome (modified Rankin Scale scores 3-6), death, and symptomatic intracranial hemorrhage (sICH) based on the criteria of the European Cooperative Acute Stroke Study II trial. Unadjusted and adjusted odds ratios (ORs) with 95% confidence intervals (CIs) were calculated. Patients without IVT treatment served as a comparison group. RESULTS: Among 4,780 IVT-treated patients, 1,217 (25.5%) had a low GFR (<60 mL/min/1.73 m(2)). A GFR decrease by 10 mL/min/1.73 m(2) increased the risk of poor outcome (OR [95% CI]): (ORunadjusted 1.20 [1.17-1.24]; ORadjusted 1.05 [1.01-1.09]), death (ORunadjusted 1.33 [1.28-1.38]; ORadjusted 1.18 [1.11-1.249]), and sICH (ORunadjusted 1.15 [1.01-1.22]; ORadjusted 1.11 [1.04-1.20]). Low GFR was independently associated with poor 3-month outcome (ORadjusted 1.32 [1.10-1.58]), death (ORadjusted 1.73 [1.39-2.14]), and sICH (ORadjusted 1.64 [1.21-2.23]) compared with normal GFR (60-120 mL/min/1.73 m(2)). Low GFR (ORadjusted 1.64 [1.21-2.23]) and stroke severity (ORadjusted 1.05 [1.03-1.07]) independently determined sICH. Compared with patients who did not receive IVT, treatment with IVT in patients with low GFR was associated with poor outcome (ORadjusted 1.79 [1.41-2.25]), and with favorable outcome in those with normal GFR (ORadjusted 0.77 [0.63-0.94]). CONCLUSION: Renal function significantly modified outcome and complication rates in IVT-treated stroke patients. Lower GFR might be a better risk indicator for sICH than age. A decrease of GFR by 10 mL/min/1.73 m(2) seems to have a similar impact on the risk of death or sICH as a 1-point-higher NIH Stroke Scale score measuring stroke severity.
Resumo:
Intraoperative cardiac imaging plays a key role during transcatheter aortic valve replacement. In recent years, new techniques and new tools for improved image quality and virtual navigation have been proposed, in order to simplify and standardize stent valve positioning and implantation. But routine performance of the new techniques may require major economic investments or specific knowledge and skills and, for this reason, they may not be accessible to the majority of cardiac centres involved in transcatheter valve replacement projects. Additionally, they still require injections of contrast medium to obtain computed images. Therefore, we have developed and describe here a very simple and intuitive method of positioning balloon-expandable stent valves, which represents the evolution of the 'dumbbell' technique for echocardiography-guided transcatheter valve replacement without angiography. This method, based on the partial inflation of the balloon catheter during positioning, traps the crimped valve in the aortic valve orifice and, consequently, very near to the ideal landing zone. It does not require specific echocardiographic knowledge; it does not require angiographies that increase the risk of postoperative kidney failure in elderly patients, and it can be also performed in centres not equipped with a hybrid operating room.
Resumo:
Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.
Resumo:
OBJECTIVES: Tissue engineering methods can be applied to regenerate diseased, or congenitally missing, urinary tract tissues. Urinary tract tissue cell cultures must be established in vitro and adequate matrices, acting as cell carriers, must be developed. Although degradable and nondegradable polymer matrices offer adequate mechanical stability, they are not optimal for cell adherence and growth. To overcome this problem, extracellular matrix proteins, permitting cell adhesion and regulation of cell proliferation and differentiation, can be adsorbed to the surface-modified polymer. METHODS: In this study, nondegradable polymer films, poly(ethylene terephthalate), were used as an experimental model. Films were modified by graft polymerization of acrylic acid to subsequently allow collagen type I and III immobilization. The following adhesion, proliferation of human urothelial cells, and induction of their stratification were analyzed. RESULTS: Collagen adsorption on 0.2 microg/cm2 poly(acrylic acid)-grafted polymer films rendered the matrix apt for human urothelial cell adhesion and proliferation. Furthermore, stratification of urothelial cells was demonstrated on these surface-modified matrices. CONCLUSIONS: These results have shown that surface-modified polymer matrices can be used to act as cell carriers for cultured human urothelial cells. Such a cell-matrix construct could be applied in reparative surgery of the urinary tract.
Resumo:
The quantitative assessment of the age-dependent number of neuritic plaques is essential for the diagnosis of Alzheimer type dementia. This study reports the superiority of a modified Hortega-Globus stain compared to Bielschowsky and Bodian stains applied to samples obtained from ten brains of patients with a clinical history of progressive dementia. In two of ten cases only the modified Hortega-Globus stain allowed confirmation of the diagnosis of senile dementia of the Alzheimer type (SDAT). The counts of neuritic plaques in sections stained by other methods were not sufficient to establish the histological diagnosis of SDAT. These results indicate that the choice of the most sensitive staining method is critical for the correct histopathologic diagnosis of the Alzheimer type dementia.
Resumo:
PURPOSE: To study the clinical outcome in hippocampal deep brain stimulation (DBS) for the treatment of patients with refractory mesial temporal lobe epilepsy (MTLE) according to the electrode location. METHODS: Eight MTLE patients implanted in the hippocampus and stimulated with high-frequency DBS were included in this study. Five underwent invasive recordings with depth electrodes to localize ictal onset zone prior to chronic DBS. Position of the active contacts of the electrode was calculated on postoperative imaging. The distances to the ictal onset zone were measured as well as atlas-based hippocampus structures impacted by stimulation were identified. Both were correlated with seizure frequency reduction. RESULTS: The distances between active electrode location and estimated ictal onset zone were 11±4.3 or 9.1±2.3mm for patients with a >50% or <50% reduction in seizure frequency. In patients (N=6) showing a >50% seizure frequency reduction, 100% had the active contacts located <3mm from the subiculum (p<0.05). The 2 non-responders patients were stimulated on contacts located >3mm to the subiculum. CONCLUSION: Decrease of epileptogenic activity induced by hippocampal DBS in refractory MTLE: (1) seems not directly associated with the vicinity of active electrode to the ictal focus determined by invasive recordings; (2) might be obtained through the neuromodulation of the subiculum.
Resumo:
RAPPORT DE SYNTHESEBUTLe but de cette étude est de suivre prospectivement les résultats d'une sclérectomie profonde (SP) modifiée en utilisant le tube Ex-PRJESS LR-50, associée à une phacoémulsification avec implantation d'une lentille intraoculaire (LIO), dans la chirurgie combinée du glaucome et de la cataracte.METHODENous avons inclus dans l'étude 24 yeux de 24 patients présentant un glaucome médicalement non contrôlé et une cataracte justifiant son ablation.Une phacoémulsification avec implantation d'une LIO est effectuée. Puis le tube Ex-PRESS LR-50 est inséré au niveau du canal de Schlemm, dans la chambre antérieure, sous un volet scléral. Une SP postérieure partielle est ensuite pratiquée afin de créer une bulle de filtration intrasclérale.Le taux de succès complet a été défini par une pression intraoculaire (PIO) <18 mmHg sans traitement et le taux de succès relatif par une PIO <18 mmHg avec ou sans traitement. En cas de fibrose ou de kyste de la bulle de filtration, une injection sous-conjonctivale d'une solution de Mitomycin C à 0.02% est réalisée, avec ou sans needling.RESULTATSLe suivi moyen était de 40.1±10.8 [moyenne±DS] mois. En préopératoire, la PIO se situait à 18.1 ±5.3 mmHg; la meilleure acuité visuelle corrigée (MAVC) était mesurée à 0.6±0.3 (échelle de Snellen) et le nombre de médicaments hypotenseurs oculaires était de 2.3±1.1. La PIO a diminué de 25.4% à 24 mois et de 27.0% à 48 mois. A 24 mois, 19 patients (86.3%) avaient une MAVC supérieure ou égal à 0.5, et à 48 mois la MAVC était mesurée à 0.7±0.3. Lors de la dernière visite, le nombre moyen de médicaments se situait à 0.6±0.8 (p<0.05). Des injections sous conjonctivales d'une solution de Mitomycin C à 0.02% ont été nécessaires dans 5 yeux. Aucune érosion conjonctivale n'a été constatée. Deux complications majeures ont été observées. Une endophtalmie, deux jours après l'intervention chirurgicale avec phtisis secondaire du globe oculaire. Une obstruction du tube Ex-PRESS LR-50 par de la fibrine, ayant justifié son ablation avec SP classique en un autre site.CONCLUSIONLe tube Ex-PRESS LR-50 inséré dans la chambre antérieure avec une SP modifiée réduit efficacement la PIO dans la chirurgie combinée du glaucome et prévient l'érosion conjonctivale, une complication importante lorsque l'implant n'est pas couvert par un volet scléral.
Resumo:
The impact of biocontrol strain Pseudomonas fluorescens CHA0 and of its genetically modified, antibiotic-overproducing derivative CHA0/pME3424 on a reconstructed population of the plant-beneficial Sinorhizobium meliloti bacteria was assessed in gnotobiotic systems. In sterile soil, the final density of the reconstructed S. meliloti population decreased by more than one order of magnitude in the presence of either of the Pseudomonas strains when compared to a control without addition of P. fluorescens. Moreover, there was a change in the proportion of each individual S. meliloti strain within the population. Plant tests also revealed changes in the nodulating S. meliloti population in the presence of strains CHA0 or CHA0/pME3424. In both treatments one S. meliloti strain, f43, was significantly reduced in its root nodule occupancy. Analysis of alfalfa yields showed a slight but statistically significant increase in shoot dry weight when strain CHA0 was added to the reconstructed S. meliloti population whereas no such effect was observed with CHA0/pME3424.
Resumo:
INTRODUCTION: Spectral frequencies of the surface electromyogram (sEMG) increase with contraction force, but debate still exists on whether this increase is affected by various methodological and anatomical factors. This study aimed to investigate the influence of inter-electrode distance (IED) and contraction modality (step-wise vs. ramp) on the changes in spectral frequencies with increasing contraction strength for the vastus lateralis (VL) and vastus medialis (VM) muscles. METHODS: Twenty healthy male volunteers were assessed for isometric sEMG activity of the VM and VL, with the knee at 90° flexion. Subjects performed isometric ramp contractions in knee extension (6-s duration) with the force gradually increasing from 0 to 80 % MVC. Also, subjects performed 4-s step-wise isometric contractions at 10, 20, 30, 40, 50, 60, 70, and 80 % MVC. Interference sEMG signals were recorded simultaneously at different IEDs: 10, 20, 30, and 50 mm. The mean (F mean) and median (F median) frequencies and root mean square (RMS) of sEMG signals were calculated. RESULTS: For all IEDs, contraction modalities, and muscles tested, spectral frequencies increased significantly with increasing level of force up to 50-60 % MVC force. Spectral indexes increased systematically as IED was decreased. The sensitivity of spectral frequencies to changes in contraction force was independent of IED. The behaviour of spectral indexes with increasing contraction force was similar for step-wise and ramp contractions. CONCLUSIONS: In the VL and VM muscles, it is highly unlikely that a particular inter-electrode distance or contraction modality could have prevented the observation of the full extent of the increase in spectral frequencies with increasing force level.