326 resultados para cardiac catheterization

em Université de Lausanne, Switzerland


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Myocardial infarction is rare in children, if it occurs, findings are almost similar to adults. In Ouchenne muscular dystrophy (OMO), ST segment displacement associated with typical chest pain can occur. We report the case of a young boy with OMO presenting symptoms suggestive of myocardial ischemia. Case report: 7 year old boy, diagnosed with OMO, eoming to the emergency department with complaints of acute chest pain, dyspnoea and anxiety the night before. Clinical examination was not remarkable, with exception of findings of the OMO. ECG showed important ST-segment elevation in right precordial leads. Major increase in troponin 1 42.33 mcg/(normal, <0.04 mcg/I) was found. Echocardiography revealed slight yskinesia of postero-septal wall without decrease in ventricular function. As acute pain had happened more han 12 hours before referral and as the child was asymptomatic, he received anti-platelets therapy. The serum level of troponin 1 declined and the ECG normalised in a few days. Cardiac catheterization did not show any coronary anomaly or eardiac dysfunction. Cardiac biopsy revealed myocardial cell damaged compatible with OMO cardiomyopathy. Tc99m myocardial single-photon emission computed tomography (SPECT) did not show any radionuclide uptake defect. Conclusions: ln this particular context of children with OMO, the classical signs of myocardial ischemia could be misleading, standard investigation failed to demonstrate the cause of chest pain and inerease of troponin l, there was also no evidence of myocarditis. Role of late enhancement (LE) signal in eontrast-enhanced MRI in the understanding of the occurring process has to be evaluated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This retrospective, multicentre study evaluated patients with lymphangioleiomyomatosis (LAM) and pre-capillary pulmonary hypertension (PH) by right heart catheterisation. It was conducted in 20 females with a mean ± SD age of 49 ± 12 yrs and a mean ± SD time interval between LAM and PH diagnoses of 9.2 ± 9.8 yrs. All, except for one patient, were receiving supplemental oxygen. 6-min walking distance was mean ± SD 340 ± 84 m. Haemodynamic characteristics were: mean pulmonary artery pressure (PAP) 32 ± 6 mmHg, cardiac index 3.5 ± 1.1 L · min(-1) · m(-2) and pulmonary vascular resistance (PVR) 376 ± 184 dyn · s · cm(-5). Mean PAP was >35 mmHg in only 20% of cases. The forced expiratory volume in 1 s was 42 ± 25%, carbon monoxide transfer factor was 29 ± 13%, and arterial oxygen tension (P(a,O(2))) was 7.4 ± 1.3 kPa in room air. Mean PAP and PVR did not correlate with P(a,O(2)). In six patients who received oral pulmonary arterial hypertension (PAH) therapy, the PAP decreased from 33 ± 9 mmHg to 24 ± 10 mmHg and the PVR decreased from 481 ± 188 dyn · s · cm(-5) to 280 ± 79 dyn · s · cm(-5). The overall probability of survival was 94% at 2 yrs. Pre-capillary PH of mild haemodynamic severity may occur in patients with LAM, even with mild pulmonary function impairment. PAH therapy might improve the haemodynamics in PH associated with LAM.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation is a feasible therapeutic option for selected patients with severe aortic stenosis and high or prohibitive risk for standard surgery. Lung transplant recipients are often considered high-risk patients for heart surgery because of their specific transplant-associated characteristics and comorbidities. We report a case of successful transfemoral transcatheter aortic valve replacement in a lung transplant recipient with a symptomatic severe aortic stenosis, severe left ventricular dysfunction, and end-stage renal failure 9 years after bilateral lung transplantation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS: Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES: Survival, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE: In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Patients who have acute coronary syndromes with or without ST-segment elevation have high rates of major vascular events. We evaluated the efficacy of early clopidogrel administration (300 mg) (<24 hours) when given with aspirin in such patients. METHODS: We included 30,243 patients who had an acute coronary syndrome with or without ST segment elevation. Data on early clopidogrel administration were available for 24,463 (81%). Some 15,525 (51%) of the total cohort were administrated clopidogrel within 24h of admission. RESULTS: In-hospital death occurred in 2.9% of the patients in the early clopidogrel group treated with primary PCI and in 11.4% of the patients in the other group without primary percutaneous coronary intervention (PCI) and no early clopidogrel. The unadjusted clopidogrel odds ratio (OR) for mortality was 0.31 (95% confidence interval 0.27-0.34; p <0.001). Incidence of major adverse cardiac death (MACE) was 4.1% in the early clopidogrel group treated with 1°PCI and 13.5% in the other group without primary PCI and no early clopidogrel (OR 0.35, confidence interval 0.32-0.39, p <0.001). Early clopidogrel administration and PCI were the only treatment lowering mortality as shown by mutlivariate analysis. CONCLUSIONS: The early administration of the anti-platelet agent clopidogrel in patients with acute coronary syndromes with or without ST-segment elevation has a beneficial effect on mortality and major adverse cardiac events. The lower mortality rate and incidence of MACE emerged with a combination of primary PCI and early clopidogrel administration.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The time-lag between coronary occlusion and irreversible damage to the myocardium is ill-defined in man. In 10 patients the changes in left ventricular function have been studied after coronary occlusion during diagnostic or therapeutic cardiac catheterization of 1-2 hours' duration. Revascularization was achieved either surgically or through intracoronary streptokinase infusion. The interval between occlusion and onset of extracorporal circulation or reopening was 61 to 119 minutes. Despite enzyme elevation (CPK, CK-MB, SGOT) and appearance of Q-waves in 5 patients, no significant alteration of left ventricular function was noted on repeat cardiac catheterization 10 to 230 days after the accident. These observations, suggest that coronary occlusion of 1-2 hours' duration fails to produce significant irreversible damage to the myocardium despite electrocardiographic and enzymatic signs of myocardial infarction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS: The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS: The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To assess the impact of patient admission in different hospital types in Switzerland on early in-hospital and 1-year outcomes in patients with acute coronary syndrome (ACS).Methods: From 1997 to 2009, 31,010 ACS patients from 76 Swiss hospitals were enrolled in the AMIS Plus registry. Large tertiary teaching institutions with 24 hour/7 day cardiac catheterization facilities were classified as type A hospitals, all others as type B. One-year outcome was studied in a subgroup of patients admitted after 2005. Multivariate logistic regression models were used to calculate the odds ratios (OR with 95%CI) for independent predictors of mortality and major adverse cardiac events (MACE).Results: There were 11 type A hospitals with admissions of 15,987 (52%) patients and 65 type B hospitals with 15,023 (48%) patients. Patients initially admitted into B hospitals were older, more frequently female, hypertensive and diabetic, had more severe comorbidities and more frequently NSTE-ACS/UA. They were less likely to receive aspirin, clopidogrel and GPIIb/IIIa antagonists. STE-ACS patients initially admitted into B hospitals received more thrombolysis than those admitted into A hospitals, but less percutaneous coronary intervention (PCI). From the patients admitted to B hospitals, 5271 (35%) were transferred for intervention. Crude in-hospital mortality and MACE were higher in patients from B hospitals. Crude 1-year mortality of 3747 ACS patients followed up was higher in patients initially admitted into B hospitals, but no differences were found for MACE. Hospital type, after adjustment for age, risk factors, type of ACS and co-morbidities, was not an independent predictor of in-hospital mortality (OR 0.94; 0.76-1.16), in-hospital MACE (0.98; 0.82-1.17), 1-year mortality or 1-year MACE (1.06; 0.85-1.33). Analysis of the time of admission indicated a crude outcome in favor of hospitalization during duty-hours but no significant effect could be documented for 1-year outcome.Conclusion: ACS patients admitted to type B hospitals were older, had more severe co-morbidities, more NSTEACS and received less intensive treatment. However, after correcting for baseline inequalities, early and mid-term outcomes were similar regardless of hospital type. Ultimate patient outcome thus does not appear to be influenced by the type of hospital where the initial admission takes place. Appropriate early referral of selected patients probably partly explains this finding.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aortic stenosis mostly occurs among old-old patients. Once symptoms appear, prognosis is guarded, with 2-year mortality as high as 50%. Transcatheter Aortic Valve Implantation (TAVI) is a new therapeutic option in patients at very high surgical risk, who are mostly older persons. However, TAVI is associated with some complications, and patient selection remains a challenge. Comprehensive geriatric assessment (CGA) identifies patients with medical and functional problems likely to affect the TAVI post-operative course. Collaboration between cardiologists and geriatricians will likely become a standard approach to enhance the assessment of these frail patients and identify those most likely to benefit from TAVI.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Atrial arrhythmias (AAs) are a common complication in adult patients with congenital heart disease. We sought to compare the lifetime prevalence of AAs in patients with right- versus left-sided congenital cardiac lesions and their effect on the prognosis. A congenital heart disease diagnosis was assigned using the International Disease Classification, Ninth Revision, diagnostic codes in the administrative databases of Quebec, from 1983 to 2005. Patients with AAs were those diagnosed with an International Disease Classification, Ninth Revision, code for atrial fibrillation or intra-atrial reentry tachycardia. To ensure that the diagnosis of AA was new, a washout period of 5 years after entry into the database was used, a period during which the patient could not have received an International Disease Classification, Ninth Revision, code for AA. The cumulative lifetime risk of AA was estimated using the Practical Incidence Estimators method. The hazard ratios (HRs) for mortality, morbidity, and cardiac interventions were compared between those with right- and left-sided lesions after adjustment for age, gender, disease severity, and cardiac risk factors. In a population of 71,467 patients, 7,756 adults developed AAs (isolated right-sided, 2,229; isolated left-sided, 1,725). The lifetime risk of developing AAs was significantly greater in patients with right- sided than in patients with left-sided lesions (61.0% vs 55.4%, p <0.001). The HR for mortality and the development of stroke or heart failure was similar in both groups (HR 0.96, 95% confidence interval [CI] 0.86 to 1.09; HR 0.94, 95% CI 0.80 to 1.09; and HR 1.10, 95% CI 0.98 to 1.23, respectively). However, the rates of cardiac catheterization (HR 0.63, 95% CI 0.55 to 0.72), cardiac surgery (HR 0.40, 95% CI 0.36 to 0.45), and arrhythmia surgery (HR 0.77, 95% CI 0.6 to 0.98) were significantly less for patients with right-sided lesions. In conclusion, patients with right-sided lesions had a greater lifetime burden of AAs. However, their morbidity and mortality were no less than those with left-sided lesions, although the rate of intervention was substantially different.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A published formula containing minimal aortic cross-sectional area and the flow deceleration pattern in the descending aorta obtained by cardiovascular magnetic resonance predicts significant coarctation of the aorta (CoA). However, the existing formula is complicated to use in clinical practice and has not been externally validated. Consequently, its clinical utility has been limited. The aim of this study was to derive a simple and clinically practical algorithm to predict severe CoA from data obtained by cardiovascular magnetic resonance. Seventy-nine consecutive patients who underwent cardiovascular magnetic resonance and cardiac catheterization for the evaluation of native or recurrent CoA at Children's Hospital Boston (n = 30) and the University of California, San Francisco (n = 49), were retrospectively reviewed. The published formula derived from data obtained at Children's Hospital Boston was first validated from data obtained at the University of California, San Francisco. Next, pooled data from the 2 institutions were analyzed, and a refined model was created using logistic regression methods. Finally, recursive partitioning was used to develop a clinically practical prediction tree to predict transcatheter systolic pressure gradient ≥ 20 mm Hg. Severe CoA was present in 48 patients (61%). Indexed minimal aortic cross-sectional area and heart rate-corrected flow deceleration time in the descending aorta were independent predictors of CoA gradient ≥ 20 mm Hg (p <0.01 for both). A prediction tree combining these variables reached a sensitivity and specificity of 90% and 76%, respectively. In conclusion, the presented prediction tree on the basis of cutoff values is easy to use and may help guide the management of patients investigated for CoA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Devices for venous cannulation have seen significant progress over time: the original, rigid steel cannulas have evolved toward flexible plastic cannulas with wire support that prevents kinking, very thin walled wire wound cannulas allowing for percutaneous application, and all sorts of combinations. In contrast to all these rectilinear venous cannula designs, which present the same cross-sectional area over their entire intravascular path, the smartcanula concept of "collapsed insertion and expansion in situ" is the logical next step for venous access. Automatically adjusting cross-sectional area up to a pre-determined diameter or the vessel lumen provides optimal flow and ease of use for both, insertion and removal. Smartcanula performance was assessed in a small series of patients (76 +/- 17 kg) undergoing redo procedures. The calculated target pump flow (2.4 L/min/m2) was 4.42 +/- 61 L/ min. Mean pump flow achieved during cardiopulmonary bypass was 4.84 +/- 87 L/min or 110% of the target. Reduced atrial chatter, kink resistance in situ, and improved blood drainage despite smaller access orifice size, are the most striking advantages of this new device. The benefits of smart cannulation are obvious in remote cannulation for limited access cardiac surgery, but there are many other cannula applications where space is an issue, and that is where smart cannulation is most effective.