5 resultados para bio-based nanocomposites

em Université de Lausanne, Switzerland


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Abstract in English : Ubiquitous Computing is the emerging trend in computing systems. Based on this observation this thesis proposes an analysis of the hardware and environmental constraints that rule pervasive platforms. These constraints have a strong impact on the programming of such platforms. Therefore solutions are proposed to facilitate this programming both at the platform and node levels. The first contribution presented in this document proposes a combination of agentoriented programming with the principles of bio-inspiration (Phylogenesys, Ontogenesys and Epigenesys) to program pervasive platforms such as the PERvasive computing framework for modeling comPLEX virtually Unbounded Systems platform. The second contribution proposes a method to program efficiently parallelizable applications on each computing node of this platform. Résumé en Français : Basée sur le constat que les calculs ubiquitaires vont devenir le paradigme de programmation dans les années à venir, cette thèse propose une analyse des contraintes matérielles et environnementale auxquelles sont soumises les plateformes pervasives. Ces contraintes ayant un impact fort sur la programmation des plateformes. Des solutions sont donc proposées pour faciliter cette programmation tant au niveau de l'ensemble des noeuds qu'au niveau de chacun des noeuds de la plateforme. La première contribution présentée dans ce document propose d'utiliser une alliance de programmation orientée agent avec les grands principes de la bio-inspiration (Phylogénèse, Ontogénèse et Épigénèse). Ceci pour répondres aux contraintes de programmation de plateformes pervasives comme la plateforme PERvasive computing framework for modeling comPLEX virtually Unbounded Systems . La seconde contribution propose quant à elle une méthode permettant de programmer efficacement des applications parallélisable sur chaque noeud de calcul de la plateforme

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monitoring of posture allocations and activities enables accurate estimation of energy expenditure and may aid in obesity prevention and treatment. At present, accurate devices rely on multiple sensors distributed on the body and thus may be too obtrusive for everyday use. This paper presents a novel wearable sensor, which is capable of very accurate recognition of common postures and activities. The patterns of heel acceleration and plantar pressure uniquely characterize postures and typical activities while requiring minimal preprocessing and no feature extraction. The shoe sensor was tested in nine adults performing sitting and standing postures and while walking, running, stair ascent/descent and cycling. Support vector machines (SVMs) were used for classification. A fourfold validation of a six-class subject-independent group model showed 95.2% average accuracy of posture/activity classification on full sensor set and over 98% on optimized sensor set. Using a combination of acceleration/pressure also enabled a pronounced reduction of the sampling frequency (25 to 1 Hz) without significant loss of accuracy (98% versus 93%). Subjects had shoe sizes (US) M9.5-11 and W7-9 and body mass index from 18.1 to 39.4 kg/m2 and thus suggesting that the device can be used by individuals with varying anthropometric characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Few studies compare the variabilities that characterize environmental (EM) and biological monitoring (BM) data. Indeed, comparing their respective variabilities can help to identify the best strategy for evaluating occupational exposure. The objective of this study is to quantify the biological variability associated with 18 bio-indicators currently used in work environments. METHOD: Intra-individual (BV(intra)), inter-individual (BV(inter)), and total biological variability (BV(total)) were quantified using validated physiologically based toxicokinetic (PBTK) models coupled with Monte Carlo simulations. Two environmental exposure profiles with different levels of variability were considered (GSD of 1.5 and 2.0). RESULTS: PBTK models coupled with Monte Carlo simulations were successfully used to predict the biological variability of biological exposure indicators. The predicted values follow a lognormal distribution, characterized by GSD ranging from 1.1 to 2.3. Our results show that there is a link between biological variability and the half-life of bio-indicators, since BV(intra) and BV(total) both decrease as the biological indicator half-lives increase. BV(intra) is always lower than the variability in the air concentrations. On an individual basis, this means that the variability associated with the measurement of biological indicators is always lower than the variability characterizing airborne levels of contaminants. For a group of workers, BM is less variable than EM for bio-indicators with half-lives longer than 10-15 h. CONCLUSION: The variability data obtained in the present study can be useful in the development of BM strategies for exposure assessment and can be used to calculate the number of samples required for guiding industrial hygienists or medical doctors in decision-making.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report here on a new insight for bio- sensing based on the memristive effect of functional- ized Schottky-barrier memristive silicon nanowire in dry environment. The device concept is discussed. Elec- trical measurements confirm the bio-detection by the narrowing of the memristive Ids − Vds hysteresis upon interaction of antigen with antibody-functionalized nanowire.