140 resultados para anterior chamber depth

em Université de Lausanne, Switzerland


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: Extension of retinoblastoma cells anterior to the vitreous surface is a criteria used to categorize retinoblastomas in Group E. In some cases, the assessment of anterior chamber invasion is readily visible by slit lamp examination, but in other cases, invasion of the posterior chamber is clinically difficult to determinate. Ultrasound biomicroscopy (UBM) allows high-resolution images of the anterior segment and structures normally hidden from clinical visualization such as ciliary body, zonule or posterior chamber. This prompted us to evaluate the value of UBM in the assessment of posterior and anterior chamber involvement in patients with peripheral extending retinoblastomas. Methods: We retrospectively reviewed all retinoblastoma cases that underwent enucleation in our institution from 1.1996 till 12.2009 in which UBM ( 35-MHz or 50-MHz) evaluation was available. The UBM results were compared with the histopathological data. Results: From 1.1996 till 12.2009, 146 enucleations were performed in our institution. UBM information was available in 18 cases. There were 8 males and 10 females. The mean age was 4 years old. UBM allowed correct assessement of posterior chamber invasion in 15 cases (13 cases with retinoblastoma in the posterior chamber and 2 cases without retinoblastoma in the posterior chamber). There was a significant correlation between the presence of retinoblastoma cells in the posterior chamber detected by UBM and the histopathological confirmation of posterior chamber involvement (p=0,0008). The sensitivity of UBM in the assessment of posterior chamber invasion by retinoblastoma was 81% and the specificity 100%. UBM allowed correct assessment of anterior chamber invasion in 13 cases. The sensitivity of UBM for this purpose was 50% and the specificity 60 %. Conclusions: In selected cases of advanced retinoblastoma, UBM appears to represent a valuable tool in the evaluation of the precise extension of the disease. Although our series encompasses only a limited number of cases, the sensitivity and specificity of UBM in the assessment of retinoblastoma anterior extension is interesting. Further prospective multi-centered clinical studies would be necessary to better delineate the utility of this method in the precise categorization of retinoblastoma anterior extension

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: to evaluate the efficacy and the safety of low dose intraocular tissue plasminogen activator (rt-PA) in the treatment of traumatic hyphema and postoperative fibrinous membrane. METHODS: Six microg to 10 microg of rt-PA was injected into the anterior chamber to treat severe fibrinous postoperative membranes and total traumatic hyphemae. RESULTS: Thirteen eyes of 13 patients were treated. Four cases of traumatic hyphema and 9 cases of fibrinous membranes were included. Complete fibrinolysis within 24 hours was observed in 4 cases (30.8%). A partial success was noted in 7 eyes (53.8%). No beneficial effect was observed in two cases of traumatic hyphema associated with intravitreal hemorrhage after penetrating trauma. No side effect attributable to rt-PA occurred. CONCLUSION: Low dose intraocular rt-PA appears to be safe and effective in the treatment of postoperative fibrinous membrane and endocular hemorrhage limited to the anterior chamber.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Extension of retinoblastoma cells into the posterior chamber is a criterion for group E according to the international classification of intraocular retinoblastoma. Currently, the anterior extension of retinoblastoma is based on the presence of tumour cells in the anterior chamber assessed by biomicroscopy. AIM: To determine the value of ultrasound biomicroscopy (UBM) in the assessment of posterior chamber involvement in advanced retinoblastoma. METHODS: Retrospective review of all retinoblastoma cases enucleated at the Jules Gonin Eye Hospital from January 1996 to December 2009 for which UBM (35 MHz) evaluation was available. The patients' records were reviewed for patient and tumour features and histopathological findings. UBM findings were compared with histopathological features. RESULTS: UBM documentation was available in 31 cases. Retinoblastoma was detected by UBM in the posterior chamber in 18 cases and was absent in 13 cases while histopathological analysis demonstrated its presence in the posterior chamber in 22 cases and its absence in 9 cases. Among the 18 UBM-positive cases, 7 had biomicroscopic detectable involvement of the anterior chamber. There was a significant correlation between echodensities consistent with retinoblastoma on UBM in the posterior chamber and histopathological tumorous involvement of the posterior chamber (p=0.0001). The sensitivity of UBM in the assessment of posterior chamber invasion by retinoblastoma was 81% and the specificity was 100%. CONCLUSION: In selected cases of advanced retinoblastoma, UBM appears to represent a valuable tool in the precise evaluation of anterior extension of disease, with good sensitivity and specificity for the assessment of posterior chamber involvement. UBM may provide useful criteria governing the indication for enucleation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To describe the evolution of retinal thickness in eyes affected with acute anterior uveitis (AAU) in the course of follow-up and to assess its correlation with severity of inflammatory activity in the anterior chamber. Methods: Design: Prospective, cohort study Setting: Institutional study Patient population: 72 eyes (affected and fellow eyes) of 36 patients Observation procedure: Patients were followed daily until beginning of resolution of inflammatory activity and weekly thereafter. Optical coherence tomography and laser flare photometry were performed at each visit. Treatment consisted of topical corticosteroids Main outcome measures: Retinal thickness of affected eyes, difference in retinal thickness between affected and fellow eyes and their evolution in time, association between maximal retinal thickness and initial laser flare photometry. Results: Difference in retinal thickness between affected and fellow eyes became significant on average seven days from baseline and remained so through-out follow-up (p<0.001). There was a steep increase in retinal thickness of affected eyes followed by a progressive decrease after reaching a peak value. Maximal difference in retinal thickness between affected and fellow eyes was observed between 17 and 25 days from baseline and exhibited a strong, positive correlation with initial laser flare photometry values (p=0.015). Conclusions: Retinal thickness in eyes affected with AAU presents a steep increase over 3 to 4 weeks and then gradually decreases. Severity of inflammation at baseline predicts the amount of retinal thickening in affected eyes. A characteristic pattern of temporal response of retinal anatomy to inflammatory stimuli seems to arise.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: To describe the use of anterior segment optical coherence tomography (AS-OCT) to clarify the position and patency of aqueous shunt devices in the anterior chamber of eyes where corneal edema or tube position does not permit a satisfactory view. DESIGN: Noncomparative observational case series. METHODS: Four cases are reported in which aqueous shunt malposition or obstruction was suspected but the shunt could not be seen on clinical examination. The patients underwent AS-OCT to identify the position and patency of the shunt tip. RESULTS: In each case, AS-OCT provided data regarding tube position and/or patency that could not be obtained by slit-lamp examination or by gonioscopy that influenced management. CONCLUSIONS: AS-OCT can be used to visualize anterior chamber tubes in the presence of corneal edema that precludes an adequate view or in cases where the tube is retracted into the cornea. In such cases, AS-OCT is useful in identifying shunt patency and position, which helps guide clinical decision making.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To evaluate inter- and intraobserver variability of indices crucial for detection of keratoconus progression derived from the Pentacam HR® (high-resolution) tomographer (OCULUS Optikgeräte GmbH, Wetzlar, Germany) in patients with mild to moderate keratoconus. Methods: Three repeated corneal topography measurements in the 25-picture mode by two independent observers were performed. The extent of variability across a large range of measurement parameters was analyzed including anterior and posterior corneal surface measurements, pachymetry values, corneal volume, anterior chamber volume and depth, and iridocorneal angle. The intraclass correlation coefficient (ICC) between and within each investigator was calculated to assess reproducibility and repeatability, respectively. Results: 31 eyes of 20 patients (mean age 31.6, SD ± 8.6) were included. Overall, the repeatability and reproducibility were excellent. The range of variability was reported by calculating the standard deviation of measurements. The detailed results are shown in Table 1. Conclusions: This study shows that the Pentacam HR® tomographer provides reliable measurements in patients with mild to moderate keratoconus. However, all parameters showed a certain range of variability. This should be taken into account when assessing keratoconus progression in order to distinguish true progression from variability in measurements. In addition, the excellent reproducibility suggests that the measurements can be reliably performed by different individuals from one visit to another.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Nitrosative stress takes place in endothelial cells (EC) during corneal acute graft rejection. The purpose of this study was to evaluate the potential role of peroxynitrite on corneal EC death. METHODS: The effect of peroxynitrite was evaluated in vivo. Fifty, 250, and 500 microM in 1.5 microL of the natural or denatured peroxynitrite in 50 microM NaOH, 50 microM NaOH alone, or balanced salt solution were injected into the anterior chamber of rat eyes (n=3/group). Corneal toxic signs after injection were assessed by slit-lamp, in vivo confocal imaging, pachymetry, and EC count. The effect of peroxynitrite was also evaluated on nitrotyrosine and leucocyte elastase inhibitor/LDNase II immunohistochemistry. Human corneas were incubated with peroxynitrite and the effect on EC viability was evaluated. A specific inducible nitric oxide synthase inhibitor (iNOS) was administered systemically in rats undergoing allogeneic corneal graft rejection and the effect on EC was evaluated by EC count. RESULTS: Rat eyes receiving as little as 50 microM peroxynitrite showed a specific dose-dependent toxicity on EC. We observed an intense nitrotyrosine staining of human and rat EC exposed to peroxynitrite associated with leucocyte elastase inhibitor nuclear translocation, a noncaspase dependent apoptosis reaction. Specific inhibition of iNOS generation prevented EC death and enhanced EC survival of the grafted corneas. However, inhibition of iNOS did not have a significant influence on the incidence of graft rejection. CONCLUSION: Nitrosative stress during acute corneal graft rejection in rat eyes induces a noncaspase dependent apoptotic death in EC. Inhibition of nitric oxide production during the corneal graft rejection has protective effects on the corneal EC survival.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Chicken pox is a very common infectious disease in children. Its corneal involvement is less serious than with measles, which may lead to blindness in numerous developing countries. However, with occasional cases occur. A case of a 59-year-old male patient whose left cornea was involved during a chicken pox infection at the age of 7 is reported. More recently, the vision of the right eye was normal at 20/20 and reduced to visual perception in the affected left eye. Corneal sensitivity was maintained in the left eye, which, however exhibited a central epithelial defect. A central round opacity of the left corneal stroma was believed to be the scar resulting from a previous disciform keratitis. The left central cornea was thinned and there was neither an anterior chamber flare nor new corneal vessels. This corneal condition required a corneal allograft, performed quickly because of the potential risk of perforation. Histopathological study of the corneal button showed a central corneal thinning with an increase in epithelial thickness. The corneal stroma was disorganized, with irregular collagen bundles. No inflammatory cells could be observed, however. All the histopathological changes observed were those of a corneal scar.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The biocompatibility of a viscous, hydrophobic, bioerodible poly(ortho ester) (POE) intended for intraocular application was investigated. POE was evaluated as a blank carrier and as containing modulators of degradation. Each formulation was injected intracamerally and intravitreally in rabbit eyes, and clinical and histological examinations were performed postoperatively for 2 weeks. In the case of intracameral injections, polymer biocompatibility appeared to depend on the amount injected in the anterior chamber. When 50 microL was administered, the polymer degraded within 2 weeks, and clinical observations showed good biocompatibility of POE with no toxicity to the ocular tissues or increase in intraocular pressure. The injection of a larger volume, 100 microL, of POE, appeared inappropriate because of direct contact of polymeric material with the corneal endothelium, and triggered reversible edema and inflammation in the anterior chamber of the eye that regressed after a few days. After intravitreal administration, POE was well tolerated and no inflammatory reaction developed during the observation period. The polymer degraded slowly, appearing as a round whitish bubble in the vitreous cavity. The presence of modulators of degradation both improved POE biocompatibility and prolonged polymer lifetime in the eye. POE appears to be a promising biomaterial for clinical intraocular application.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To evaluate the incidence of presumed endophthalmitis (EO) after intravitreal injection (IVI) of anti-vascular endothelial growth factor agents performed in the operating room. METHODS: Retrospective study at 2 Swiss eye hospitals between 2004 and 2012. Hospital records were used to identify patients treated with an IVI of an anti-vascular endothelial growth factor agent between 2004 and 2012 and those treated for EO, defined as any intraocular inflammation treated with intravitreal antibiotics. All IVIs were performed using standard sterile technique in a Swiss Class 1 operating room. No patient received preinjection topical antibiotics. Postinjection topical antibiotics were used only in one hospital. RESULTS: A total of 40,011 IVIs were performed at the 2 centers during the study period. Of the IVIs, ranibizumab was injected in 36,398 (91%), bevacizumab in 3,518 (9%), aflibercept in 89 (0.2%), and pegaptanib in 6 (<0.1%). Three cases of post-IVI presumed EO occurred, yielding a combined incidence of 0.0075% per injection (95% confidence interval: 0.0026-0.0220%) or 1 case per 13,337 IVIs. Two of the three cases of EO occurred in patients using post-IVI antibiotics. All three cases followed ranibizumab injection and were culture negative by anterior chamber tap or vitreous biopsy. CONCLUSION: The risk of EO after IVI performed under the sterile conditions of the operating room was very low.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The biocompatibility of autocatalyzed poly(ortho ester) (POE(70)LA(30)), a viscous, hydrophobic, bioerodible polymer, was investigated. POE(70)LA(30) was synthesized, sterilized by gamma irradiation, and injected in rabbit eyes at adequate volumes through subconjunctival, intracameral, intravitreal, and suprachoroidal routes. Clinical examinations were performed postoperatively at regular time points for 6 mo, and histopathologic analysis was carried out to confirm tissular biocompatibility. After subconjunctival injection, the polymer was well tolerated and persisted in the subconjunctival space for about 5 weeks. In the case of intracameral injections, polymer biocompatibility was good; the POE(70)LA(30) bubble was still present in the anterior chamber for up to 6 mo after injection. No major histopathologic anomalies were detected, with the exception of a localized Descemet membrane thickening. After intravitreal administration, POE(70)LA(30) biocompatibility was excellent, and no inflammatory reaction could be detected during the observation period. The polymer was degraded in approximately 3 mo. Suprachoroidal injections of POE(70)LA(30) were reproducible and well tolerated. POE(70)LA(30) triggered a slight elevation of the retina and choroid upon clinical observation. The polymer was detectable in the suprachoroidal space for about 6 mo. No inflammatory reaction and no major retinal anomalies could be detected by histology. In conclusion, POE(70)LA(30) appears to be a promising biomaterial for intraocular application, potentially providing sustained drug delivery over an extended period of time, with a good tolerance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background:  Study in vivo characteristics of a polymethylmethacrylate (PMMA) implant compared to the standard cylindrical collagen implant for deep sclerectomy (DS). Design:  Six-month comparative study. Samples:  Twenty eyes of ten rabbits. Methods:  Eyes were randomized to have DS with PMMA implant in one eye and collagen implant in the opposite eye. The growth of the new subconjunctival drainage vessels was assessed by combined fluorescein and indocyanin green anterior segment angiography; intrascleral and subconjunctival blebs were imaged by ultrasound biomicroscopy (UBM). At six months, outflow facility (C) was measured by anterior chamber perfusion and portions of one side of the DS were compared to portions on the 180° opposite side and native sclera on histology. Results:  The mean IOP preoperatively and at one, four, twelve, and twenty-four weeks was comparable in both groups (P > 0.1). UBM showed a statistically insignificant quicker regression of the subconjunctival bleb as well as a durable intrascleral lake in the PMMA group (P > 0.05). New drainage vessels were initially observed one month after surgery; they were more numerous in the PMMA group on angiographic and histological findings at 6 months (P < 0.05). The mean C increased significantly after surgery compared to preoperative values (P < 0.05) and no difference was observed between the implants (0.24 ± 0.06 µl/min/mmHg [PMMA] and 0.23 ± 0.07 µl/min/mmHg [collagen implant]) (P = 0.39). Conclusions:  Deep sclerectomy performed with PMMA or collagen implants showed similar IOP lowering effects, outflow facility increase, and degree of inflammatory reaction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Here we report the case of an immunocompetent 8-year-old child who developed acute retinal necrosis concomitant with a primary herpes simplex virus type I infection. Ocular inflammation changed along with the development of a specific antibody titer in the serum. This evidence suggests that the immune response of the host can significantly modulate the clinical aspect of the ocular infection.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Euphorbia plants grow in many gardens. Their milky latex is, however, a strong irritant which may induce various ocular lesions from keratoconjunctivitis to severe uveitis. HISTORY AND SIGNS: A 86-year-old woman developed a unilateral severe anterior chamber inflammation associated with descemtic folds after direct contact with sap of Euphorbia. Visual acuity was limited to counting fingers. Her eye was operated from filtering surgery ten years previously. The patient was closely followed to rule out the diagnosis of bacterial endophthalmitis. THERAPY AND OUTCOME: Symptoms progressively resolved after topical administration of 3 mg/mL ofloxacine and 1 % prednisolone acetate. CONCLUSIONS: Euphorbia sap toxicity may take different forms from keratoconjunctivitis to severe uveitis. Euphorbia sap-induced uveitis should be kept in mind when the patient has seen in contact with freshly cut plants.