162 resultados para anomalous origin of the left coronary artery
em Université de Lausanne, Switzerland
Resumo:
We report an unusual case of congenital giant coronary aneurysm. A 23 year-old male with a history of acute myocardial infarction presented an abnormal shadow in the left cardiac border on routine X-ray. Electrocardiogram and physical examination were normal without any clinical signs of inflammation, but computed tomography (CT) scan and cardiac magnetic resonance imaging (MRI) revealed a giant (>50mm) coronary aneurysm. Coronary artery bypass grafting (CABG) with coronary artery aneurysm (CAA) resection resolved the CAA. Coronary artery aneurysms are entities of localised dilation and can be common events in chronic infectious disease as a result of the systemic inflammatory state; however, giant coronary aneurysms (measuring more than 50mm) are rare. This is especially true where the pathological aetiology was not clearly defined or was believed to be of congenital origin. To date only a few published case reports exist for this type of pathological entity.
Resumo:
Aberrant origin of a pulmonary artery from the ascending aorta is an uncommon congenital vascular malformation with poor survival without surgery. In this case report, we describe the unusual late diagnosis of this congenital malformation in an otherwise asymptomatic young man presenting with mild hemoptysis. We review the natural and modified history of this defect and the relevant aspects of follow-up in adult life.
Resumo:
Introduction: Coronary magnetic resonance angiography (MRA) is a medical imaging technique that involves collecting data from consecutive heartbeats, always at the same time in the cardiac cycle, in order to minimize heart motion artifacts. This technique relies on the assumption that coronary arteries always follow the same trajectory from heartbeat to heartbeat. Until now, choosing the acquisition window in the cardiac cycle was based exclusively on the position of minimal coronary motion. The goal of this study was to test the hypothesis that there are time intervals during the cardiac cycle when coronary beat-to-beat repositioning is optimal. The repositioning uncertainty values in these time intervals were then compared with the intervals of low coronary motion in order to propose an optimal acquisition window for coronary MRA. Methods: Cine breath-hold x-ray angiograms with synchronous ECG were collected from 11 patients who underwent elective routine diagnostic coronarography. Twenty-three bifurcations of the left coronary artery were selected as markers to evaluate repositioning uncertainty and velocity during cardiac cycle. Each bifurcation was tracked by two observers, with the help of a user-assisted algorithm implemented in Matlab (The Mathworks, Natick, MA, USA) that compared the trajectories of the markers coming from consecutive heartbeats and computed the coronary repositioning uncertainty with steps of 50ms until 650ms after the R-wave. Repositioning uncertainty was defined as the diameter of the smallest circle encompassing the points to be compared at the same time after the R-wave. Student's t-tests with a false discovery rate (FDR, q=0.1) correction for multiple comparison were applied to see whether coronary repositioning and velocity vary statistically during cardiac cycle. Bland-Altman plots and linear regression were used to assess intra- and inter-observer agreement. Results: The analysis of left coronary artery beat-to-beat repositioning uncertainty shows a tendency to have better repositioning in mid systole (less than 0.84±0.58mm) and mid diastole (less than 0.89±0.6mm) than in the rest of the cardiac cycle (highest value at 50ms=1.35±0.64mm). According to Student's t-tests with FDR correction for multiple comparison (q=0.1), two intervals, in mid systole (150-200ms) and mid diastole (550-600ms), provide statistically better repositioning in comparison with the early systole and the early diastole. Coronary velocity analysis reveals that left coronary artery moves more slowly in end systole (14.35±11.35mm/s at 225ms) and mid diastole (11.78±11.62mm/s at 625ms) than in the rest of the cardiac cycle (highest value at 25ms: 55.96±22.34mm/s). This was confirmed by Student's t-tests with FDR correction for multiple comparison (q=0.1, FDR-corrected p-value=0.054): coronary velocity values at 225, 575 and 625ms are not much different between them but they are statistically inferior to all others. Bland-Altman plots and linear regression show that intra-observer agreement (y=0.97x+0.02 with R²=0.93 at 150ms) is better than inter-observer (y=0.8x+0.11 with R²=0.67 at 150ms). Discussion: The present study has demonstrated that there are two time intervals in the cardiac cycle, one in mid systole and one in mid diastole, where left coronary artery repositioning uncertainty reaches points of local minima. It has also been calculated that the velocity is the lowest in end systole and mid diastole. Since systole is less influenced by heart rate variability than diastole, it was finally proposed to test an acquisition window between 150 and 200ms after the R-wave.
Resumo:
Non-infarcted myocardium after coronary occlusion undergoes progressive morphological and functional changes. The purpose of this study was to determine whether non-infarcted myocardium exhibits (1) alteration of the substrate pattern of myocardial metabolism and (2) concomitant changes in the expression of regulatory proteins of glucose and fatty acid metabolism. Myocardial infarction was induced in rats by ligation of the left coronary artery. One day and eight weeks after coronary occlusion, glucose and palmitate oxidation were measured. Expression of selected proteins of metabolism were determined one day to 12 weeks after infarction. One day after coronary occlusion no difference of glucose and palmitate oxidation was detectable, whereas after eight weeks, glucose oxidation was increased (+84%, P<0.05) and palmitate oxidation did not change significantly (-19%, P=0.07) in infarct-containing hearts, compared with hearts from sham-operated rats. One day after coronary occlusion, myocardial mRNA expression of the glucose transporter GLUT-1 was increased (+86%, P<0.05) and the expression of GLUT-4 was decreased (-28%, P<0.05) in surviving myocardium of infarct-containing hearts. Protein level of GLUT-1 was increased (+81%, P<0.05) and that of GLUT-4 slightly, but not significantly, decreased (-16%, P=NS). mRNA expressions of heart fatty acid binding protein (H-FABP), and of medium chain acyl-CoA dehydrogenase (MCAD), were decreased by 36% (P<0.05) and 35% (P=0. 07), respectively. Eight weeks after acute infarction, the left ventricle was hypertrophied and, at this time-point, there was no difference in the expression of GLUT-1 and GLUT-4 between infarcted and sham-operated hearts. However, myocardial mRNA and protein content of MCAD were decreased by 30% (P<0.01) and 27% (P<0.05), respectively. In summary, in surviving myocardium, glucose oxidation was increased eight weeks after coronary occlusion. Concomitantly, mRNA and protein expression of MCAD were decreased, compatible with a role of altered expression of regulatory proteins of metabolism in post-infarction modification of myocardial metabolism.
Resumo:
Objective: Impaired blood flow of the gastric tube represents a major cause of anastomotic leakage after esophageal resection. In order to improve local vascularisation, preoperative embolization (PE) of the left gastric artery has recently been proposed. The aimof this study was to assess our initial experience of this novel approach with a particular focus on anastomotic leakage.Methods: A consecutive series of 102 patients (81 male, 21 female, median age 64 years) underwent resection (82 Ivor-Lewis procedures, 9 transhiatal resections, 11 triple incisions) for esophageal malignancies at our institution from 2000 to 2009. Since 2004, PE was used selectively in 19 patients 21 days prior to elective esophagectomy. Selection criteria were normal gastric vascular anatomy, no pre-existing vascular disease, i.e. atheromatosis of the celiac trunk or superior mesenteric artery, and resectability of the tumor. PE was performed under local anesthesia on a dedicated system in a standard fashion. Following percutaneous transfemoral visceral angiography to identify gastric vascular anatomy, embolization was performed either with 5-F or with coaxial 3-F catheters and fibered metal coils. We analyzed retrospectively patient's data, operative data, and outcome from a prospective database.Results: The overall anastomotic leakage rate was 18・6% (19/102 patients); cervical anastomosis had a leak rate of 25% compared to intrathoracic anastomosis leak rate of 18・2%. While 17 of 83 patients without PE developed anastomotic leakage (20・5%), there were only 2 of 19 patients after PE revealing an anastomotic leakage (10・5%). Otherwise, patients with PE had no more other complications. There was only one PE-related complication (i.e. partial splenic necrosis).Mean hospital stay was 25 days versus 27 days for patients with PE and without PE, respectively. The mortality rate was 7・8% (8/102 patients), whereby four deaths were related to anastomotic leakage (1 and 3 patients with PE and without PE, respectively).Conclusion: PE is an interesting novel approach to improve gastric blood flow in order to minimize anastomotic leakage. Its application is safe and technically easy. Our preliminary experience revealed a decrease of the anastomotic leakage rate of almost 50%.
Resumo:
A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). METHODS: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. RESULTS: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. CONCLUSION: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.
Resumo:
We performed a systematic review of the literature to establish whether revascularisation of the left subclavian territory is necessary when this artery is covered by a stent. We retrieved data from 99 studies incorporating 4906 patients. Incidences of left-arm ischaemia (0.0% vs 9.2%, p=0.002) and stroke (4.7% vs 7.2%, p<0.001) were significantly less following revascularisation, although mortality (10.5% vs 3.4%, p=0.032) and endoleak incidence (25.8% vs 12.6%, p=0.008) were increased. No significant differences in spinal-cord ischaemia were seen. Revascularisation may reduce downstream ischaemic complications but can cause significant risk. Indications must be carefully considered on an individual patient basis.
Resumo:
OBJECTIVE: Our objective was to compare two state-of-the-art coronary MRI (CMRI) sequences with regard to image quality and diagnostic accuracy for the detection of coronary artery disease (CAD). SUBJECTS AND METHODS: Twenty patients with known CAD were examined with a navigator-gated and corrected free-breathing 3D segmented gradient-echo (turbo field-echo) CMRI sequence and a steady-state free precession sequence (balanced turbo field-echo). CMRI was performed in a transverse plane for the left coronary artery and a double-oblique plane for the right coronary artery system. Subjective image quality (1- to 4-point scale, with 1 indicating excellent quality) and objective image quality parameters were independently determined for both sequences. Sensitivity, specificity, and accuracy for the detection of significant (> or = 50% diameter) coronary artery stenoses were determined as defined in invasive catheter X-ray coronary angiography. RESULTS: Subjective image quality was superior for the balanced turbo field-echo approach (1.8 +/- 0.9 vs 2.3 +/- 1.0 for turbo field-echo; p < 0.001). Vessel sharpness, signal-to-noise ratio, and contrast-to-noise ratio were all superior for the balanced turbo field-echo approach (p < 0.01 for signal-to-noise ratio and contrast-to-noise ratio). Of the 103 segments, 18% of turbo field-echo segments and 9% of balanced turbo field-echo segments had to be excluded from disease evaluation because of insufficient image quality. Sensitivity, specificity, and accuracy for the detection of significant coronary artery stenoses in the evaluated segments were 92%, 67%, 85%, respectively, for turbo field-echo and 82%, 82%, 81%, respectively, for balanced turbo field-echo. CONCLUSION: Balanced turbo field-echo offers improved image quality with significantly fewer nondiagnostic segments when compared with turbo field-echo. For the detection of CAD, both sequences showed comparable accuracy for the visualized segments.
Resumo:
BACKGROUND/AIMS: Restenosis after percutaneous transluminal angioplasty (PTA) of the internal mammary artery (IMA) grafts is much less pronounced than in other arteries and venous grafts. The aim of the study was to test whether various arteries respond differently to dilatation. METHODS: PTA of the IMA, carotid, renal and circumflex coronary (RCx) arteries was performed in 9 pigs (balloon to artery ratio of 1:1.5). After 8 weeks, angiography was repeated and vessels prepared for histological analysis. Immunohistochemical staining was done to examine proliferative activity (Ki67) and to identify the vasa vasorum of the adventitia (F VIII-RA). RESULTS: The intima-media ratio after PTA was lowest in the IMA (0.06), followed by the carotid (0.27) and renal arteries (0.49) and the RCx (0.69). Proliferation of the intima was seen at 287 degrees of the vessel circumference in the RCx, at 286 degrees in the renal and at 166 degrees in the carotid artery. No proliferative activity was seen in the IMA. The intima-adventitia ratio was lower in the IMA than in the RCx and renal arteries (p < 0.05). CONCLUSION: Intima proliferation after PTA varies between the different vessels, with best results seen in the IMA. There are differences in remodeling after PTA between muscular, muscular/elastic and elastic arteries.
Resumo:
The neuropsychological records of 56 patients operated for clipping were studied. Almost every patient remained autonomous and without invalidating motor defect. The present study was aimed at specifying the type and frequency of neuropsychological sequelae and, to a lesser extent, the role of various pathophysiological factors. A main concern was to examine to what extent and at what post-operative interval the neuropsychological assessment can predict the intellectual and socioprofessional outcome of each individual patient. The neuropsychological assessment performed beyond the acute phase showed evidence of intellectual sequelae in about two thirds of the patients. Only one case of permanent anterograde amnesia was observed, probably due to unavoidable inclusion of a hypothalamic artery in the clip during surgery. Transient anterograde amnesia and confabulations were occasionally observed, generally for less than three weeks. A common finding was impaired performance on memory and/or executive tests. In a minority of patients, language disorders, visuoperceptive and visuoconstructive disabilities were found, probably in relation with hemodynamic changes at distance from the aneurysm. Global impairment of intellectual function was not uncommon in the acute post-operative phase but it evolved in most cases towards a more selective impairment, for instance restricted to executive and memory functions, in the chronic phase. The neuropsychological investigation carried out 4 to 15 weeks post-operatively provided satisfactory information about possible long-lasting intellectual disturbances and professional resumption. In particular, persistent global intellectual impairment, persistent amnesia and confabulations 4-15 weeks post-operative were associated with cessation of professional activity; executive and memory impairment, behavioral disturbances such as those encountered in patients with frontal lobe damage were associated with a decreased probability of full-time employment. Pre- and post-operative angiography were not good predictors of long-term cognitive outcome: normal angiography was not necessarily followed by normal neuropsychological outcome, conversely abnormal angiography could be found together with normal neuropsychological outcome. By contrast, there was a relationship between left-lateralised abnormalities on post-operative angiography and occurrence of language disorders; similarly, there was a relationship between side of craniotomy and type of deficits, that is language disorders versus visuoperceptive-visuoconstructive impairments.
Resumo:
INTRODUCTION: The pathogenic mechanism of orthostatic proteinuria has not yet been clearly established. OBSERVATION: In a tall, thin, 21 year-old man, isolated proteinuria was discovered during an urological control conducted one year after a bilateral orchidopexy following left testicular torsion. Proteinuria was orthostatic. Doppler examination of the kidney revealed an entrapment of the left renal vein (nutcracker phenomenon-NCP). COMMENTS: An NCP was diagnosed in a young patient presenting with orthostatic proteinuria. By provoking modifications in intraglomerular haemodynamics, the NCP may, in nearly half of the cases, be at the origin of orthostatic proteinuria. Doppler examination is the diagnostic method of choice in the screening for NCP.