19 resultados para angular displacement
em Université de Lausanne, Switzerland
Resumo:
Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.
Resumo:
The determination of characteristic cardiac parameters, such as displacement, stress and strain distribution are essential for an understanding of the mechanics of the heart. The calculation of these parameters has been limited until recently by the use of idealised mathematical representations of biventricular geometries and by applying simple material laws. On the basis of 20 short axis heart slices and in consideration of linear and nonlinear material behaviour we have developed a FE model with about 100,000 degrees of freedom. Marching Cubes and Phong's incremental shading technique were used to visualise the three dimensional geometry. In a quasistatic FE analysis continuous distribution of regional stress and strain corresponding to the endsystolic state were calculated. Substantial regional variation of the Von Mises stress and the total strain energy were observed at all levels of the heart model. The results of both the linear elastic model and the model with a nonlinear material description (Mooney-Rivlin) were compared. While the stress distribution and peak stress values were found to be comparable, the displacement vectors obtained with the nonlinear model were generally higher in comparison with the linear elastic case indicating the need to include nonlinear effects.
Resumo:
Direct absolute dating of the Penninic Frontal Thrust tectonic motion is achieved using the Ar-40/Ar-39 technique in the Pelvoux Crystalline Massif (Western Alps). The dated phengites were formed syn-kinematically in shear zones. They underline the brittle-ductile stretching lineation, pressure-shadow fibres and slickensides consistent with underthrusting of the European continental slab below the propagating Penninic Thrust. Chlorite-phengite thermobarometry yields 10-15 km and T similar to 280 degrees C, while Ar-40/Ar-39 phengite ages mainly range between 34 and 30 Ma, with one younger age at 27 Ma. This Early Oligocene age range matches a major tectonic rearrangement of the Alpine chain. Preservation of prograde Ar-40/Ar-39 ages is ascribed to passive exhumation of the Pelvoux shear zone network, sandwiched between more external thrusts and the Penninic Front reactivated as an E-dipping detachment fault. Partial resetting in the Low Temperature part of argon spectra below 24 Ma is ascribed to brittle deformation and alteration of phengites.
Resumo:
Methods are presented to map complex fiber architectures in tissues by imaging the 3D spectra of tissue water diffusion with MR. First, theoretical considerations show why and under what conditions diffusion contrast is positive. Using this result, spin displacement spectra that are conventionally phase-encoded can be accurately reconstructed by a Fourier transform of the measured signal's modulus. Second, studies of in vitro and in vivo samples demonstrate correspondence between the orientational maxima of the diffusion spectrum and those of the fiber orientation density at each location. In specimens with complex muscular tissue, such as the tongue, diffusion spectrum images show characteristic local heterogeneities of fiber architectures, including angular dispersion and intersection. Cerebral diffusion spectra acquired in normal human subjects resolve known white matter tracts and tract intersections. Finally, the relation between the presented model-free imaging technique and other available diffusion MRI schemes is discussed.
Resumo:
Purpose: To investigate the effect of incremental increases in intraocular straylight on threshold measurements made by three modern forms of perimetry: Standard Automated Perimetry (SAP) using Octopus (Dynamic, G-Pattern), Pulsar Perimetry (PP) (TOP, 66 points) and the Moorfields Motion Displacement Test (MDT) (WEBS, 32 points).Methods: Four healthy young observers were recruited (mean age 26yrs [25yrs, 28yrs]), refractive correction [+2 D, -4.25D]). Five white opacity filters (WOF), each scattering light by different amounts were used to create incremental increases in intraocular straylight (IS). Resultant IS values were measured with each WOF and at baseline (no WOF) for each subject using a C-Quant Straylight Meter (Oculus, Wetzlar, Germany). A 25 yr old has an IS value of ~0.85 log(s). An increase of 40% in IS to 1.2log(s) corresponds to the physiological value of a 70yr old. Each WOFs created an increase in IS between 10-150% from baseline, ranging from effects similar to normal aging to those found with considerable cataract. Each subject underwent 6 test sessions over a 2-week period; each session consisted of the 3 perimetric tests using one of the five WOFs and baseline (both instrument and filter were randomised).Results: The reduction in sensitivity from baseline was calculated. A two-way ANOVA on mean change in threshold (where subjects were treated as rows in the block and each increment in fog filters was treated as column) was used to examine the effect of incremental increases in straylight. Both SAP (p<0.001) and Pulsar (p<0.001) were significantly affected by increases in straylight. The MDT (p=0.35) remained comparatively robust to increases in straylight.Conclusions: The Moorfields MDT measurement of threshold is robust to effects of additional straylight as compared to SAP and PP.
Resumo:
Dynamic mixtures of Rh-dye complexes can be used to determine the history of chemical events such as the addition of ATP and ADP by UV-vis spectroscopy.
Resumo:
Purpose: To examine the relationship of functional measurements with structural measures. Methods: 146 eyes of 83 test subjects underwent Heidelberg Retinal Tomography (HRTIII) (disc area<2.43, mphsd<40), and perimetry testing with Octopus (SAP; Dynamic), Pulsar (PP; TOP) and Moorfields MDT (ESTA). Glaucoma was defined as progressive structural or functional loss (20 eyes). Perimetry test points were grouped into 6 sectors based on the estimated optic nerve head angle into which the associated nerve fiber bundle enters (Garway-Heath map). Perimetry summary measures (PSM) (MD SAP/ MD PP/ PTD MDT) were calculated from the average total deviation of each measured threshold from the normal for each sector. We calculated the 95% significance level of the sectorial PSM from the respective normative data. We calculated the percentage agreement with group1 (G1), healthy on HRT and within normal perimetric limits, and group 2 (G2), abnormal on HRT and outside normal perimetric limits. We also examined the relationship of PSM and rim area (RA) in those sectors classified as abnormal by MRA (Moorfields Regression Analysis) of HRT. Results: The mean age was 65 (range= [37, 89]). The global sensitivity versus specificity of each instrument in detecting glaucomatous eyes was: MDT 80% vs. 88%, SAP 80% vs. 80%, PP 70% vs. 89% and HRT 80% vs. 79%. Highest percentage agreement of HRT (respectively G1, G2, sector) with PSM were MDT (89%, 57%, nasal superior), SAP (83%, 74%, temporal superior), PP (74%, 63%, nasal superior). Globally percentage agreement (respectively G1, G2) was MDT (92%, 28%), SAP (87%, 40%) and PP (77%, 49%). Linear regression showed there was no significant trend globally associating RA and PSM. However, sectorally the supero-nasal sector had a statistically significant (p<0.001) trend with each instrument, the associated r2 coefficients are (MDT 0.38 SAP 0.56 and PP 0.39). Conclusions: There were no significant differences in global sensitivity or specificity between instruments. Structure-function relationships varied significantly between instruments and were consistently strongest supero-nasally. Further studies are required to investigate these relationships in detail.
Where do industrial workers go after plant closure? Survey evidence two years after job displacement
Resumo:
subsequent extension-induced exhumation. Geochronological dating of various Structural, thermobarometric, and geochronological data place limits on the age and tectonic displacement along the Zanskar shear zone, a major north-dipping synorogenic extensional structure separating the high-grade metamorphic sequence of the High Himalayan Crystalline Sequence from the overlying low-grade sedimentary rocks of the Tethyan Himalaya, A complete Barrovian metamorphic succession, from kyanite to biotite zone mineral assemblages, occurs within the I-km-thick Zanskar shear zone. Thermobarometric data indicate a difference In equilibration depths of 12 +/- 3 km between the lower kyanite zone and the garnet zone, which is Interpreted as a minimum estimate for the finite vertical displacement accommodated by the Zanskar shear zone. For the present-day dip of the structure (20 degrees), a simple geometrical model shows that a net slip of 35 +/- 9 km is required to regroup these samples to the same structural level. Because the kyanite to garnet zone rocks represent only part of the Zanskar shear zone, and because its original dip may have been less than the present-day dip, these estimates fur the finite displacement represent minimum values. Field relations and petrographic data suggest that migmatization and associated leucogranite intrusion in the footwall of the Zanskar shear zone occurred as a continuous profess starting at the Barrovian metamorphic peak and lasting throughout the subsequent extension-induced exhumation. Geochronological dataing of various leucogranitic plutons and dikes in the Zanskar shear zone footwall indicates that the main ductile shearing along the structure ended by 19.8 Ma and that extension most likely initiated shortly before 22.2 Ma.
Resumo:
Purpose: To compare the performance Glaucoma Quality of Life-15 (GQL-15) Questionnaire, intraocular pressure measurement (IOP Goldmann tonometry) and a measure of visual field loss using Moorfields Motion Displacement Test (MDT) in detecting glaucomatous eyes from a self referred population. Methods: The GQL-15 has been suggested to correlate with visual disability and psychophysical measures of visual function in glaucoma patients. The Moorfields MDT is a multi location perimetry test with 32 white line stimuli presented on a grey background on a standard laptop computer. Each stimulus is displaced between computer frames to give the illusion of "apparent motion". Participants (N=312, 90% older than 45 years; 20.5% family history of glaucoma) self referred to an advertised World Glaucoma Day (March 2009) Jules Gonin Eye Hospital, Lausanne Switzerland. Participants underwent a clinical exam (IOP, slit lamp, angle and disc examination by a general ophthalmologist), 90% completed a GQL-15 questionnaire and over 50% completed a MDT test in both eyes. Those who were classified as abnormal on one or more of the following (IOP >21 mmHg/ GQL-15 score >20/ MDT score >2/ clinical exam) underwent a follow up clinical examination by a glaucoma specialist including imaging and threshold perimetry. After the second examination subjects were classified as "healthy"(H), "glaucoma suspect" (GS) (ocular hypertension and/or suspicious disc, angle closure with SD) or "glaucomatous" (G). Results: One hundred and ten subjects completed all 4 initial examinations; of these 69 were referred to complete the 2nd examination and were classified as; 8 G, 24 GS, and 37 H. MDT detected 7/8 G, and 7/24 GS, with false referral rate of 3.8%. IOP detected 2/8 G and 8/24 GS, with false referral rate of 8.9%. GQL-15 detected 4/8 G, 16/24 GS with a false referral rate of 42%. Conclusions: In this sample of participants attending a self referral glaucoma detection event, the MDT performed significantly better than the GQL-15 and IOP in discriminating glaucomatous patients from healthy subjects. Further studies are required to assess the potential of the MDT as a glaucoma screening tool.
Resumo:
When dealing with multi-angular image sequences, problems of reflectance changes due either to illumination and acquisition geometry, or to interactions with the atmosphere, naturally arise. These phenomena interplay with the scene and lead to a modification of the measured radiance: for example, according to the angle of acquisition, tall objects may be seen from top or from the side and different light scatterings may affect the surfaces. This results in shifts in the acquired radiance, that make the problem of multi-angular classification harder and might lead to catastrophic results, since surfaces with the same reflectance return significantly different signals. In this paper, rather than performing atmospheric or bi-directional reflection distribution function (BRDF) correction, a non-linear manifold learning approach is used to align data structures. This method maximizes the similarity between the different acquisitions by deforming their manifold, thus enhancing the transferability of classification models among the images of the sequence.