130 resultados para Validation of analytical methodology

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Drug abuse is a widespread problem affecting both teenagers and adults. Nitrous oxide is becoming increasingly popular as an inhalation drug, causing harmful neurological and hematological effects. Some gas chromatography-mass spectrometry (GC-MS) methods for nitrous oxide measurement have been previously described. The main drawbacks of these methods include a lack of sensitivity for forensic applications; including an inability to quantitatively determine the concentration of gas present. The following study provides a validated method using HS-GC-MS which incorporates hydrogen sulfide as a suitable internal standard allowing the quantification of nitrous oxide. Upon analysis, sample and internal standard have similar retention times and are eluted quickly from the molecular sieve 5Å PLOT capillary column and the Porabond Q column therefore providing rapid data collection whilst preserving well defined peaks. After validation, the method has been applied to a real case of N2O intoxication indicating concentrations in a mono-intoxication.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lymphocytic choriomeningitis virus (LCMV) is a rare cause of central nervous system disease in humans. Screening by real-time RT-PCR assay is of interest in the case of aseptic meningitis of unknown etiology. A specific LCMV real-time RT-PCR assay, based on the detection of genomic sequences of the viral nucleoprotein (NP), was developed to assess the presence of LCMV in cerebrospinal fluids (CSF) sent for viral screening to a Swiss university hospital laboratory. A 10-fold dilution series assay using a plasmid containing the cDNA of the viral NP of the LCMV isolate Armstrong (Arm) 53b demonstrated the high sensitivity of the assay with a lowest detection limit of ≤50 copies per reaction. High sensitivity was confirmed by dilution series assays in a pool of human CSF using four different LCMV isolates (Arm53b, WE54, Traub and E350) with observed detection limits of ≤10PFU/ml (Arm53b and WE54) and 1PFU/ml (Traub and E350). Analysis of 130 CSF showed no cases of acute infection. The absence of positive cases was confirmed by a published PCR assay detecting all Old World arenaviruses. This study validates a specific and sensitive real-time RT-PCR assay for the diagnosis of LCMV infections. Results showed that LCMV infections are extremely rare in hospitalized patients western in Switzerland.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Propane can be responsible for several types of lethal intoxication and explosions. Quantifying it would be very helpful to determine in some cases the cause of death. Some gas chromatography-mass spectrometry (GC-MS) methods of propane measurements do already exist. The main drawback of these GC-MS methods described in the literature is the absence of a specific propane internal standard necessary for accurate quantitative analysis. The main outcome of the following study was to provide an innovative Headspace-GC-MS method (HS-GC-MS) applicable to the routine determination of propane concentration in forensic toxicology laboratories. To date, no stable isotope of propane is commercially available. The development of an in situ generation of standards is thus presented. An internal-labeled standard gas (C3DH7) is generated in situ by the stoichiometric formation of propane by the reaction of deuterated water (D2O) with Grignard reagent propylmagnesium chloride (C3H7MgCl). The method aims to use this internal standard to quantify propane concentrations and, therefore, to obtain precise measurements. Consequently, a complete validation with an accuracy profile according to two different guidelines, the French Society of Pharmaceutical Sciences and Techniques (SFSTP) and the Gesellschaft für toxikologische und Forensische Chemie (GTFCh), is presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of our study was to provide an innovative HS-GC/MS method applicable to the routine determination of butane concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature concerning butane measurement was the absence of a specific butane internal standard necessary to perform quantification. Because no stable isotope of butane is commercially available, it is essential to develop a new approach by an in situ generation of standards. To avoid the manipulation of a stable isotope-labelled gas, we have chosen to generate in situ an internal labelled standard gas (C(4)H(9)D) following the basis of the stoichiometric formation of butane by the reaction of deuterated water (D(2)O) with Grignard reagent butylmagnesium chloride (C(4)H(9)MgCl). This method allows a precise measurement of butane concentration and therefore, a full validation by accuracy profile was presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Hepcidin, a 25 amino acid peptide, plays an important role in iron homeostasis. Some hepcidin truncated peptides have antibiotic effects. RESULTS: A new analytical method for hepcidin determination in human plasma using LC-HRMS operating in full-scan acquisition mode has been validated. The extraction consists of protein precipitation and a drying reconstitution step; a 2.1 x 50 mm (idxL) C18 analytical column was used. Detection specificity, stability, accuracy, precision and recoveries were determined. The LOQ/LOD were 0.25/0.1 nM, respectively. More than 600 injections of plasma extracts were performed, allowing evaluation of the assay robustness. Hepcidin-20, hepcidin-22 and a new isoform, hepcidin-24, were detected in patients. CONCLUSION: The data underscore the usefulness of LC-HRMS for in-depth investigations related to hepcidin levels and pathways.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of our study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable for the routine determination of blood CO concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature for CO measurement is the absence of a specific CO internal standard necessary for performing quantification. Even if stable isotope of CO is commercially available in the gaseous state, it is essential to develop a safer method to limit the manipulation of gaseous CO and to precisely control the injected amount of CO for spiking and calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in a vial in situ, an internal labeled standard gas ((13)CO) formed by the reaction of labeled formic acid formic acid (H(13)COOH) with sulfuric acid. As sulfuric acid can also be employed to liberate the CO reagent from whole blood, the procedure allows for the liberation of CO simultaneously with the generation of (13)CO. This method allows for precise measurement of blood CO concentrations from a small amount of blood (10 μL). Finally, this method was applied to measure the CO concentration of intoxicated human blood samples from autopsies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Ethylglucuronide (EtG) is a direct and specific metabolite of ethanol. Its determination in hair is of increasing interest for detecting and monitoring alcohol abuse. The quantification of EtG in hair requires analytical methods showing highest sensitivity and specificity. We present a fully validated method based on gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS). The method was validated using French Society of Pharmaceutical Sciences and Techniques (SFSTP) guidelines which are based on the determination of the total measurement error and accuracy profiles. Methods: Washed and powdered hair is extracted in water using an ultrasonic incubation. After purification by Oasis MAX solid phase extraction, the derivatized EtG is detected and quantified by GC-NCI-MS/MS method in the selected reaction monitoring mode. The transitions m/z 347 / 163 and m/z 347 / 119 were used for the quantification and identification of EtG. Four quality controls (QC) prepared with hair samples taken post mortem from 2 subjects with a known history of alcoholism were used. A proficiency test with 7 participating laboratories was first run to validate the EtG concentration of each QC sample. Considering the results of this test, these samples were then used as internal controls for validation of the method. Results: The mean EtG concentrations measured in the 4 QC were 259.4, 130.4, 40.8, and 8.4 pg/mg hair. Method validation has shown linearity between 8.4 and 259.4 pg/mg hair (r2 > 0.999). The lower limit of quantification was set up at 8.4 pg/mg. Repeatability and intermediate precision were found less than 13.2% for all concentrations tested. Conclusion: The method proved to be suitable for routine analysis of EtG in hair. GC-NCI-MS/MS method was then successfully applied to the analysis of EtG in hair samples collected from different alcohol consumers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gene expression data from microarrays are being applied to predict preclinical and clinical endpoints, but the reliability of these predictions has not been established. In the MAQC-II project, 36 independent teams analyzed six microarray data sets to generate predictive models for classifying a sample with respect to one of 13 endpoints indicative of lung or liver toxicity in rodents, or of breast cancer, multiple myeloma or neuroblastoma in humans. In total, >30,000 models were built using many combinations of analytical methods. The teams generated predictive models without knowing the biological meaning of some of the endpoints and, to mimic clinical reality, tested the models on data that had not been used for training. We found that model performance depended largely on the endpoint and team proficiency and that different approaches generated models of similar performance. The conclusions and recommendations from MAQC-II should be useful for regulatory agencies, study committees and independent investigators that evaluate methods for global gene expression analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: The aim of this study was to interpret and validate a French version of the Oswestry disability index (ODI), using a cross-cultural validation method. The validity and reliability of the questionnaire was assessed in order to ensure the psychometric characteristics. METHOD: The cross-cultural validation was carried out according to Beaton's methodology. The study was conducted with 41 patients suffering from low back pain. The correlation between the ODI and the Roland-Morris disability questionnaire (RMDQ), the medical outcome survey short form-36 (MOS SF-36) and a pain visual analogical scale (VAS) was assessed. RESULTS: The validity of the Oswestry questionnaire was studied using the Cronbach Alpha coefficient calculation: 0.87 (n=36). The significant correlation between the ODI and RMDQ was 0.8 (P<0.001, n=41) and 0.71 (P<0.001, n=36) for the pain VAS. The correlation between the ODI and certain subscales (physical functioning 0.7 (P<0.001, n=41), physical role 0.49 et bodily pain 0.73 (P<0.001, n=41)) of the MOS SF-36 were equally significant. The reproducibility of the ODI was calculated using the Wilcoxon matched pairs test: there was no significant difference for eight out of ten sections or for the final score. CONCLUSION: This French translation of the ODI should be considered as valid and reliable. It should be used for any future clinical studies carried out using French language patients. Complimentary studies must be completed in order to assess its sensitivity to change in the event of any modifications in the patients functional capacity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Although CD4 cell count monitoring is used to decide when to start antiretroviral therapy in patients with HIV-1 infection, there are no evidence-based recommendations regarding its optimal frequency. It is common practice to monitor every 3 to 6 months, often coupled with viral load monitoring. We developed rules to guide frequency of CD4 cell count monitoring in HIV infection before starting antiretroviral therapy, which we validated retrospectively in patients from the Swiss HIV Cohort Study.Methodology/Principal Findings: We built up two prediction rules ("Snap-shot rule" for a single sample and "Track-shot rule" for multiple determinations) based on a systematic review of published longitudinal analyses of CD4 cell count trajectories. We applied the rules in 2608 untreated patients to classify their 18 061 CD4 counts as either justifiable or superfluous, according to their prior >= 5% or < 5% chance of meeting predetermined thresholds for starting treatment. The percentage of measurements that both rules falsely deemed superfluous never exceeded 5%. Superfluous CD4 determinations represented 4%, 11%, and 39% of all actual determinations for treatment thresholds of 500, 350, and 200x10(6)/L, respectively. The Track-shot rule was only marginally superior to the Snap-shot rule. Both rules lose usefulness for CD4 counts coming near to treatment threshold.Conclusions/Significance: Frequent CD4 count monitoring of patients with CD4 counts well above the threshold for initiating therapy is unlikely to identify patients who require therapy. It appears sufficient to measure CD4 cell count 1 year after a count > 650 for a threshold of 200, > 900 for 350, or > 1150 for 500x10(6)/L, respectively. When CD4 counts fall below these limits, increased monitoring frequency becomes advisable. These rules offer guidance for efficient CD4 monitoring, particularly in resource-limited settings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ethyl glucuronide (EtG) is a minor and direct metabolite of ethanol. EtG is incorporated into the growing hair allowing retrospective investigation of chronic alcohol abuse. In this study, we report the development and the validation of a method using gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS) for the quantification of EtG in hair. EtG was extracted from about 30 mg of hair by aqueous incubation and purified by solid-phase extraction (SPE) using mixed mode extraction cartridges followed by derivation with perfluoropentanoic anhydride (PFPA). The analysis was performed in the selected reaction monitoring (SRM) mode using the transitions m/z 347-->163 (for the quantification) and m/z 347-->119 (for the identification) for EtG, and m/z 352-->163 for EtG-d(5) used as internal standard. For validation, we prepared quality controls (QC) using hair samples taken post mortem from 2 subjects with a known history of alcoholism. These samples were confirmed by a proficiency test with 7 participating laboratories. The assay linearity of EtG was confirmed over the range from 8.4 to 259.4 pg/mg hair, with a coefficient of determination (r(2)) above 0.999. The limit of detection (LOD) was estimated with 3.0 pg/mg. The lower limit of quantification (LLOQ) of the method was fixed at 8.4 pg/mg. Repeatability and intermediate precision (relative standard deviation, RSD%), tested at 4 QC levels, were less than 13.2%. The analytical method was applied to several hair samples obtained from autopsy cases with a history of alcoholism and/or lesions caused by alcohol. EtG concentrations in hair ranged from 60 to 820 pg/mg hair.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: Functional subjective evaluation through questionnaire is fundamental, but not often realized in patients with back complaints, notably because of lack of validated tools, in accordance with recognized psychometric criteria. The Spinal Function Sort (SFS), developed according to actual standards, was only validated in English. The aim of this study is to translate, adapt and validate the French and German version of the SFS.Method and material: The translation and cross-cultural adaptation were performed following the methodology proposed by the American Association of Orthopedist Surgeon. A total of 344 patients, presenting varied back complaints (especially degenerative and traumatic), took part in this study in a tertiary French- (n=87; mean age 44y; 17 women) and German-speaking (n=257; mean age 41y; 53 women) center. Test-retest reliability was quantified using the intraclass correlation coefficient (ICC) and construct validity was assessed by estimating the Pearson's correlation with the SF-36 physical and mental scales, the Visual Analogue Scale for Pain Intensity (VAS), and subscales of the Hospital Anxiety and Depression Scale (HADS).Results: Respectively for the French and German version, ICC were 0.98 and 0.94. Correlations 0.63 and 0.67 with the SF-36 Physical Functioning subscale; 0.60 and 0.52 with the SF-36 Physical Summary Scale ; -0.33 and -0.51 with the VAS ; -0.08 and 0.25 with the SF-36 Mental Health scale; 0.01 and 0.28 with the SF-36 Mental Summary Scale; -0.26 and -0.42 with the HADS depression; -0.17 and -0.45 with the HADS anxiety.Discussion: For both the French and German version of the SFS, the reliability was excellent. Convergent construct validity with SF-36 physical scales is good, moderated with the VAS. We find out a low correlation with SF-36 mental scales (divergent construct validity). We find out a low correlation with HADS subscales in the French version, and a moderate one in the German version. Selection bias, chronicity of the complaints, as well as cultural differences could explain these results. In conclusion, both the French and German version of the SFS are valid and reliable for evaluation of perceived functional capacity for patients with back complaints.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: THC-COOH has been proposed as a criterion to help to distinguish between occasional from regular cannabis users. However, to date this indicator has not been adequately assessed under experimental and real-life conditions. Methods: We carried out a controlled administration study of smoked cannabis with a placebo. Twenty-three heavy smokers and 25 occasional smokers, between 18 and 30 years of age, participated in this study [Battistella G et al., PloS one. 2013;8(1):e52545]. We collected data from a second real case study performed with 146 traffic offenders' cases in which the whole blood cannabinoid concentrations and the frequency of cannabis use were known. Cannabinoid levels were determined in whole blood using tandem mass spectrometry methods. Results: Significantly high differences in THC-COOH concentrations were found between the two groups when measured during the screening visit, prior to the smoking session, and throughout the day of the experiment. Receiver operating characteristic (ROC) curves were determined and two threshold criteria were proposed in order to distinguish between these groups: a free THC-COOH concentration below 3 μg/L suggested an occasional consumption (≤ 1 joint/week) while a concentration higher than 40 μg/L corresponded to a heavy use (≥ 10 joints/month). These thresholds were successfully tested with the second real case study. The two thresholds were not challenged by the presence of ethanol (40% of cases) and of other therapeutic and illegal drugs (24%). These thresholds were also found to be consistent with previously published experimental data. Conclusion: We propose the following procedure that can be very useful in the Swiss context but also in other countries with similar traffic policies: If the whole blood THC-COOH concentration is higher than 40 μg/L, traffic offenders must be directed first and foremost toward medical assessment of their fitness to drive. This evaluation is not recommended if the THC-COOH concentration is lower than 3 μg/L. A THC-COOH level between these two thresholds can't be reliably interpreted. In such a case, further medical assessment and follow up of the fitness to drive are also suggested, but with lower priority.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L'objectif de cette étude est de vérifier la validité interne de la version française du questionnaire d'impulsivité d'Eysenck (I7), traduite par Dupont et al., sur un échantillon d'étudiants suisses (n = 220). Dans leur questionnaire, Eysenck et Eysenck proposent trois échelles : les deux premières évaluant deux composantes distinctes de l'impulsivité (l'Impulsivité caractérisant les individus qui agissent sans penser, sans être conscients des risques associés à leurs actions, et la Recherche d'aventure caractérisant les individus qui agissent en étant conscients, et en tenant compte des risques associés à leurs actions), et la troisième servant de « distracteur » (l'Empathie caractérisant les individus qui ont la faculté de s'identifier à l'autre). La structure à trois facteurs de l'instrument a été confirmée par notre analyse factorielle en composantes principales. La solution factorielle retenue n'explique toutefois qu'une faible proportion de la variance (21.9 %). L'homogénéité interne des échelles, mesurée à l'aide d'alphas de Cronbach, est acceptable pour l'échelle d'Impulsivité (.78) et de Recherche d'aventure (.71), mais elle est, en revanche, faible pour l'échelle d'Empathie (.62). Les échelles de l'I7 d'Eysenck entretiennent des corrélations cohérentes avec les cinq grandes dimensions de la personnalité mesurées par le NEO PI-R. L'Impulsivité est associée négativement à la dimension Conscience (r = - .32), alors que la Recherche d'aventures est associée positivement à la dimension Extraversion (r = .33). Le sexe a un impact sur les échelles Recherche d'aventure et Empathie. Les qualités métrologiques de la version française du questionnaire d'impulsivité d'Eysenck (I7) sont satisfaisantes, mais l'estimation d'autres indices de validité, comme la fidélité test-retest et la validité convergente, devrait être réalisée.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND AIMS: Inflammatory bowel disease (IBD) frequently manifests during childhood and adolescence. For providing and understanding a comprehensive picture of a patients' health status, health-related quality of life (HRQoL) instruments are an essential complement to clinical symptoms and functional limitations. Currently, the IMPACT-III questionnaire is one of the most frequently used disease-specific HRQoL instrument among patients with IBD. However, there is a lack of studies examining the validation and reliability of this instrument. METHODS: 146 paediatric IBD patients from the multicenter Swiss IBD paediatric cohort study database were included in the study. Medical and laboratory data were extracted from the hospital records. HRQoL data were assessed by means of standardized questionnaires filled out by the patients in a face-to-face interview. RESULTS: The original six IMPACT-III domain scales could not be replicated in the current sample. A principal component analysis with the extraction of four factor scores revealed the most robust solution. The four factors indicated good internal reliability (Cronbach's alpha=.64-.86), good concurrent validity measured by correlations with the generic KIDSCREEN-27 scales and excellent discriminant validity for the dimension of physical functioning measured by HRQoL differences for active and inactive severity groups (p<.001, d=1.04). CONCLUSIONS: This study with Swiss children with IBD indicates good validity and reliability for the IMPACT-III questionnaire. However, our findings suggest a slightly different factor structure than originally proposed. The IMPACT-III questionnaire can be recommended for its use in clinical practice. The factor structure should be further examined in other samples.