18 resultados para Valerio Máximo

em Université de Lausanne, Switzerland


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Active surveillance in prostate cancer The spread of PSA in the screening of prostate cancer has almost doubled the incidence of this disease in the last twenty years. An improved understanding of the natural history of this cancer allows for risk stratification of the disease and to better predict insignificant prostate cancer. Active surveillance has recently been proposed as a new option to delay or avoid a radical treatment for patients with low-risk disease. The principle, results and future perspectives of this treatment modality are discussed in this review.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The AMS 800TM is the current artificial urinary sphincter (AUS) for incontinence due to intrinsic sphincter deficiency. Despite good clinical results, technical failures inherent to the hydraulic mechanism or urethral ischemic injury contribute to revisions up to 60%. We are developing an electronic AUS, called ARTUS to overcome the rigors of AMS. The objective of this study was to evaluate the technical efficacy and tissue tolerance of the ARTUS system in an animal model.Methods: The ARTUS is composed by three parts: the contractile unit, a series of rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor. In the first phase a three-rings device was used while in the second phase a two-rings ARTUS was used. The device was implanted in 14 sheep divided in two groups of six and eight animals for study purpose. The first group aimed at bladder leak point pressure (BLPP) measurement and validation of the animal model; the second group aimed at verifying mid-term tissue tolerance by explants at twelve weeks. General animal tolerance was also evaluated.Results: The ARTUS system implantation was uneventful. When the system was activated, the BLPP was measured at 1.038±0.044 bar (mean±SD). Urethral tissue analysis did not show significant morphological changes. No infection and no sign of discomfort were noted in animals at 12 weeks.Conclusions: The ARTUS proved to be effective in continence achievement in this study. Histological results support our idea that a sequential alternative mode can avoid urethral atrophy and ischemia. Further technical developments are needed to verify long-term outcome and permit human use.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: To evaluate the safety and clinical feasibility of focal irreversible electroporation (IRE) of the prostate. METHODS: We assessed the toxicity profile and functional outcomes of consecutive patients undergoing focal IRE for localised prostate cancer in two centres. Eligibility was assessed by multi-parametric magnetic resonance imaging (mpMRI) and targeted and/or template biopsy. IRE was delivered under transrectal ultrasound guidance with two to six electrodes positioned transperineally within the cancer lesion. Complications were recorded and scored accordingly to the NCI Common Terminology Criteria for Adverse Events; the functional outcome was physician reported in all patients with at least 6 months follow-up. A contrast-enhanced MRI 1 week after the procedure was carried out to assess treatment effect with a further mpMRI at 6 months to rule out evidence of residual visible cancer. RESULTS: Overall, 34 patients with a mean age of 65 years (s.d.=±6) and a median PSA of 6.1 ng ml(-1) (interquartile range (IQR)= 4.3-7.7) were included. Nine (26%), 24 (71%) and 1 (3%) men had low, intermediate and high risk disease, respectively (D'Amico criteria). After a median follow-up of 6 months (range 1-24), 12 grade 1 and 10 grade 2 complications occurred. No patient had grade >/= 3 complication. From a functional point of view, 100% (24/24) patients were continent and potency was preserved in 95% (19/20) men potent before treatment. The volume of ablation was a median 12 ml (IQR=5.6-14.5 ml) with the median PSA after 6 months of 3.4 ng ml(-1) (IQR=1.9-4.8 ng ml(-1)). MpMRI showed suspicious residual disease in six patients, of whom four (17%) underwent another form of local treatment. CONCLUSIONS: Focal IRE has a low toxicity profile with encouraging genito-urinary functional outcomes. Further prospective development studies are needed to confirm the functional outcomes and to explore the oncological potential.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neuroendocrine differentiation has been described in rectal adenocarcinomas receiving neoadjuvant therapy prior to radical surgery, but its clinical relevance is controversial and no data are currently available in colorectal carcinoma metastases as compared to primary tumors. The presence of chromogranin A positive tumor cells was investigated by means of immunohistochemistry on surgical specimens from 54 primary colorectal carcinomas and their corresponding metastases, resected at diagnosis or during tumor progression. In 47 patients, tumor metastases were resected 1 month to 12 years after chemotherapy and/or radiotherapy, while in the remaining seven patients no additional therapy after primary surgery was performed. In primary tumors, neuroendocrine differentiation was found in 12/54 cases (22.2%) as compared to 25/54 metastatic lesions (46.3%; p?=?0.01). The presence of neuroendocrine phenotype was not correlated with any clinical pathological parameter nor with a different proliferation index. However, patients having neuroendocrine cells in the primary tumor had a significantly shorter survival from the time of metastatic spread than those having not (33.3 vs. 55.5 months; p?=?0.04). In summary, our data show that colorectal carcinoma metastases contain a higher percentage of neuroendocrine differentiated cells as compared to their corresponding primaries, a finding possibly related to the influence of chemotherapy in neuroendocrine differentiation during colorectal carcinoma progression.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Primary adenocarcinoma of the bladder is a rare tumor. The classification between primary vesical and urachal is debated. We present the case of a young female who presented clinicopathological features of a metastatic urachal adenocarcinoma, but the histological result revealed primary adenocarcinoma of the bladder contrary to expectancy. To the best of our knowledge this is the first reported case of a metastatic adenocarcinoma of the bladder in a 25 years old female. This case emphasizes the challenge for urologists to recognize and manage this aggressive tumor in the setting described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: There are only a few established artificial urinary sphincters for treatment of incontinence. We have developed a new device composed by three parts: the actuator, three contractile rings and a control unit. The actuator is made of Nitinol fibers, driven by microprocessor. The fibers are linked to the rings placed around the urethra. They function with alternance in their open and closed position. This concept is called piano concept. With this set-up, the constant compression on the urethra is strongly reduced. Methods: Six male sheep have been used for this study. The sphincter was open each hour for a period of 10 min., to guaranty urination. The bladder was filled with water while one cuff was closed and bladder pressure was monitored. The animals were sacrificed. Two biopsies around two cuffs of each explant and all three cuffs from each explant including urethra were analyzed. Urethra not surrounded by a cuff was taken as control. Results: The pressure exerted by the sphincter around the urethra provided continence. Simulated incontinence occurred at a pressure of 1bar measured on the bladder wall using a pressure probe. The closing force of the cuff was approx. 0·7N. No difference in tissue structure and organization of the urethra with and without artificial sphincter was observed. Conclusions: This device has several advantages compared to other urinary sphincters. It is easy to implant, has no hydraulic nature and reduces ischemic injury of the urethra by the alternance of urethral part compressed. Proof of concept in vivo has been demonstrated. Other studies are planned to determine long-term outcome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction and objectives: The AMS 800TM is considered the gold standard for sphincter replacement. However, the one-ring design can erode the urethra and lead to severe complications. A mechanism that could alternatively compress successive segments of the urethra would limit such deleterious outcome. We report 12 weeks animal urethral tissue analysis following implantation of a new modular artificial sphincter. METHODS: The device is composed by three parts: the contractile unit, two rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor connected to an external computer. The computer can reveal specific failure of device components. The device was impkanted in eight male sheep. The rings were positioned around the urethra and the control unit was placed 5cm away. The device was working twenty hours per day; it was open 10min. per hour to allow urination. The animals were sacrificed after 12 weeks. The urethra and the tissues surrounding the control unit were macroscopically and microscopically examined. Two transversal sections crossing the sphincter and two transversal sections crossing the urethra alone were obtained and stained with modified Paragon after resin embedding. Urethra was also embedded in paraffin. The first section was stained with safranin-hematoxylin-eosin, the second section was stained with Masson's Trichrome and the remaining eight sections were available for immunolabelling of the macrophages.Results: The chronic study went uneventful. No clinical infection or pain was observed. The computer registered no specific failure in ring function, Nitinol wires and tube connectors. At explantation, except for a slight grade of lymphocytes in two out of eight specimens, no urethral stricture or atrophy could be observed. Immunohistochemistry confirmed the absence of macrophages. Tissue structure and organization of the urethra with and without artificial sphincter were similar. No migration of the device was observed.Conclusions: The study clearly showed no tissue damage or inflammation of the urethra. Electronic design, preservation of urethral vascularisation and adjustability after implantation are the key ideas to improve the actual AUS. Further studies will be carried out to evaluate this potential.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Enhanced recovery after surgery (ERAS) pathways have significantly reduced complications and length of hospital stay after colorectal procedures. This multimodal concept could probably be partially applied to major urological surgery. OBJECTIVES: The primary objective was to systematically assess the evidence of ERAS single items and protocols applied to cystectomy patients. The secondary objective was to address a grade of recommendation to each item, based on the evidence and, if lacking, on consensus opinion from our ERAS Society working group. EVIDENCE ACQUISITION: A systematic literature review was performed on ERAS for cystectomy by searching EMBASE and Medline. Relevant articles were selected and quality-assessed by two independent reviewers using the GRADE approach. If no study specific to cystectomy was available for any of the 22 given items, the authors evaluated whether colorectal guidelines could be extrapolated. EVIDENCE SYNTHESIS: Overall, 804 articles were retrieved from electronic databases. Fifteen articles were included in the present systematic review and 7 of 22 ERAS items were studied. Bowel preparation did not improve outcomes. Early nasogastric tube removal reduced morbidity, bowel recovery time and length of hospital stay. Doppler-guided fluid administration allowed for reduced morbidity. A quicker bowel recovery was observed with a multimodal prevention of ileus, including gum chewing, prevention of PONV and minimally invasive surgery. CONCLUSIONS: ERAS has not yet been widely implemented in urology and evidence for individual interventions is limited or unavailable. The experience in other surgical disciplines encourages the development of an ERAS protocol for cystectomy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Enhanced recovery after surgery (ERAS) for radical cystectomy seems logical, but our study has shown a paucity in the level of clinical evidence. As part of the ERAS Society, we welcome global collaboration to collect evidence that will improve patient outcomes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The AMS 800 is the current artifi cial urinary sphincter (AUS) forincontinence due to intrinsic sphincter defi ciency. Despite good clinical results,technical failures inherent to the hydraulic mechanism or urethral ischemicinjury contribute to revisions up to 60%. We are developing an electronic AUS,called ARTUS to overcome the rigors of AMS. The objective of this study wasto evaluate the technical effi cacy and tissue tolerance of the ARTUS systemin an animal model.Methods: The ARTUS is composed by three parts: thecontractile unit, a series of rings and an integrated microprocessor. The contractileunit is made of Nitinol fi bers. The rings are placed around the urethrato control the fl ow of urine by squeezing the urethra. They work in a sequentialalternative mode and are controlled by a microprocessor. In the fi rst phase athree-rings device was used while in the second phase a two-rings ARTUS wasused. The device was implanted in 14 sheep divided in two groups of six andeight animals for study purpose. The fi rst group aimed at bladder leak pointpressure (BLPP) measurement and validation of the animal model; the secondgroup aimed at verifying midterm tissue tolerance by explants at twelve weeks.General animal tolerance was also evaluated.Results: The ARTUS systemimplantation was uneventful. When the system was activated, the BLPP wasmeasured at 1.038 ± 0.044 bar (mean ± SD). Urethral tissue analysis did notshow signifi cant morphological changes. No infection and no sign of discomfortwere noted in animals at 12 weeks.Conclusions: The ARTUS proved to beeffective in continence achievement in this study. Histological results supportour idea that a sequential alternative mode can avoid urethral atrophy andischemia. Further technical developments are needed to verify long-termoutcome and permit human use.