8 resultados para VISUALIZATION

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the past decade, many efforts have been made to identify MHC class II-restricted epitopes from different tumor-associated Ags. Melan-A/MART-1(26-35) parental or Melan-A/MART-1(26-35(A27L)) analog epitopes have been widely used in melanoma immunotherapy to induce and boost CTL responses, but only one Th epitope is currently known (Melan-A51-73, DRB1*0401 restricted). In this study, we describe two novel Melan-A/MART-1-derived sequences recognized by CD4 T cells from melanoma patients. These epitopes can be mimicked by peptides Melan-A27-40 presented by HLA-DRB1*0101 and HLA-DRB1*0102 and Melan-A25-36 presented by HLA-DQB1*0602 and HLA-DRB1*0301. CD4 T cell clones specific for these epitopes recognize Melan-A/MART-1+ tumor cells and Melan-A/MART-1-transduced EBV-B cells and recognition is reduced by inhibitors of the MHC class II presentation pathway. This suggests that the epitopes are naturally processed and presented by EBV-B cells and melanoma cells. Moreover, Melan-A-specific Abs could be detected in the serum of patients with measurable CD4 T cell responses specific for Melan-A/MART-1. Interestingly, even the short Melan-A/MART-1(26-35(A27L)) peptide was recognized by CD4 T cells from HLA-DQ6+ and HLA-DR3+ melanoma patients. Using Melan-A/MART-1(25-36)/DQ6 tetramers, we could detect Ag-specific CD4 T cells directly ex vivo in circulating lymphocytes of a melanoma patient. Together, these results provide the basis for monitoring of naturally occurring and vaccine-induced Melan-A/MART-1-specific CD4 T cell responses, allowing precise and ex vivo characterization of responding T cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this work was to develop an easily applicable technique and a standardized protocol for high-quality post-mortem angiography. This protocol should (1) increase the radiological interpretation by decreasing artifacts due to the perfusion and by reaching a complete filling of the vascular system and (2) ease and standardize the execution of the examination. To this aim, 45 human corpses were investigated by post-mortem computed tomography (CT) angiography using different perfusion protocols, a modified heart-lung machine and a new contrast agent mixture, specifically developed for post-mortem investigations. The quality of the CT angiographies was evaluated radiologically by observing the filling of the vascular system and assessing the interpretability of the resulting images and by comparing radiological diagnoses to conventional autopsy conclusions. Post-mortem angiography yielded satisfactory results provided that the volumes of the injected contrast agent mixture were high enough to completely fill the vascular system. In order to avoid artifacts due to the post-mortem perfusion, a minimum of three angiographic phases and one native scan had to be performed. These findings were taken into account to develop a protocol for quality post-mortem CT angiography that minimizes the risk of radiological misinterpretation. The proposed protocol is easy applicable in a standardized way and yields high-quality radiologically interpretable visualization of the vascular system in post-mortem investigations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Résumé : Contexte clinique et objectifs: l'intubation oro-trachéale peut être plus difficile chez les patients obèses morbides (index de masse corporelle BMI > 35 kg/m2) que chez les patients non-obèses. Récemment, de nouveaux instruments permettant une intubation assistée au moyen d'une caméra ont été développés. Notre expérience pratique avec la vidéolaryngoscopie nous a conduit à l'hypothèse que celle-ci pourrait améliorer la vision laryngoscopique chez cette population spécifique et de ce fait faciliter l'intubation. Le but de cette étude était donc d'évaluer le bénéfice du vidéolaryngoscope sur le grade de laryngoscopie chez le patient obèse morbide. Résultats : le grade laryngoscopique fut abaissé de manière significative avec le vidéolaryngoscope comparé à la vision directe avec un laryngoscope standard. Lorsque le grade laryngoscopique était plus grand que 1 à la laryngoscopie directe, il fut dans la grande majorité des cas (93% des patients) abaissé avec le vidéolaryngoscope. Chez les 7 % restant, le grade laryngoscopique resta identique. Conclusions : chez le patient obèse morbide, l'utilisation du vidéolaryngoscope améliore de manière significative la visualisation du larynx et de ce fait facilite l'intubation. Une application systématique de ce procédé pourrait donc permettre de réduire l'incidence d'une intubation difficile ainsi que ses conséquences chez cette population de patients. Summary : Background and objective: Tracheal intubation may be more difficult in morbidly obese patients (body mass index >35 kgM-2) than in the non-obese. Recently, new video-assisted intubation devices have been developed. After some experience with videolaryngoscopy, we hypothesized that it could improve the laryngoscopic view in this specific population and therefore facilitate intubation. The aim of this study was to assess the benefit of a videolaryngoscope on the grade of laryngoscopy in morbid obesity. Methods: We studied 80 morbidly obese patients undergoing bariatric surgery. They were randomly assigned to one of two groups. One group was intubated with the help of the videolaryngoscope and in the control group the screen of the videolaryngoscope was hidden to the intubating anaesthesiologist. The primary end-point of the study was to assess in both groups the Cormack and Lehane direct and indirect grades of laryngoscopy. The duration of intubation, the number of attempts needed as well as the minimal SPO2 reached during the intubation process were measured. Results: Grade of laryngoscopy was significantly lower with the videolaryngoscope compared with the direct vision (P < 0.001). When the grade of laryngoscopy was higher than one with the direct laryngoscopy (n = 30), it was lower in 28 cases with the videolaryngoscope and remained the same only in two cases (P < 0.001). The minimal SPO2 reached during the intubation was higher with the videolaryngoscope but it did not reach statistical significance. Conclusions: In morbidly obese patients, the use of the videolaryngoscope significantly improves the visualization of the larynx and thereby facilitates intubation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Postmortem radiology had in recent years appeared in the field of forensic medicine and is now considered by some authors as a good replacement for conventional autopsy and by others as a complementary examination. Although postmortem CT radiological imaging is very useful in demonstrating traumatic lesions, its utility is still quite limited in the cardiovascular field. This limitation could be minimized by the introduction of postmortem angiography. At the University Center of Legal Medicine of Lausanne, CT scans and postmortem multiphase CTangiography are used in cases with a suspicion of ischemic heart disease.Method: The goal of this presentation is to demonstrate some correlations between postmortem CT, CTangiography and conventional autopsy examination in cases of ischemic heart disease.Results: We observed that the native CT scan can show only some pathological findings as cardiac tamponade and calcifications of coronary arteries. However, postmortem angiography allows a better visualization of coronary arteries and evaluation of stenosis and occlusion as well as better imaging of soft tissue.Conclusion: The interpretation of postmortem modern radiology is a new field for both forensic pathologists and radiologists who have to learn to read the postmortem modified images. The information obtained from both parties can help to further the understanding of CT and CT angiography in postmortem cases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Gamma Knife surgery (GKS) is a non-invasive neurosurgical stereotactic procedure, increasingly used as an alternative to open functional procedures. This includes targeting of the ventro-intermediate nucleus of the thalamus (e.g. Vim) for tremor. We currently perform an indirect targeting, as the Vim is not visible on current 3Tesla MRI acquisitions. Our objective was to enhance anatomic imaging (aiming at refining the precision of anatomic target selection by direct visualisation) in patients treated for tremor with Vim GKS, by using high field 7T MRI. MATERIALS AND METHODSH: Five young healthy subjects were scanned on 3 (T1-w and diffusion tensor imaging) and 7T (high-resolution susceptibility weighted images (SWI)) MRI in Lausanne. All images were further integrated for the first time into the Gamma Plan Software(®) (Elekta Instruments, AB, Sweden) and co-registered (with T1 was a reference). A simulation of targeting of the Vim was done using various methods on the 3T images. Furthermore, a correlation with the position of the found target with the 7T SWI was performed. The atlas of Morel et al. (Zurich, CH) was used to confirm the findings on a detailed analysis inside/outside the Gamma Plan. RESULTS: The use of SWI provided us with a superior resolution and an improved image contrast within the basal ganglia. This allowed visualization and direct delineation of some subgroups of thalamic nuclei in vivo, including the Vim. The position of the target, as assessed on 3T, perfectly matched with the supposed one of the Vim on the SWI. Furthermore, a 3-dimensional model of the Vim-target area was created on the basis of the obtained images. CONCLUSION: This is the first report of the integration of SWI high field MRI into the LGP, aiming at the improvement of targeting validation of the Vim in tremor. The anatomical correlation between the direct visualization on 7T and the current targeting methods on 3T (e.g. quadrilatere of Guyot, histological atlases) seems to show a very good anatomical matching. Further studies are needed to validate this technique, both by improving the accuracy of the targeting of the Vim (potentially also other thalamic nuclei) and to perform clinical assessment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this study was to investigate the performance of 3D synchrotron differential phase contrast (DPC) imaging for the visualization of both macroscopic and microscopic aspects of atherosclerosis in the mouse vasculature ex vivo. The hearts and aortas of 2 atherosclerotic and 2 wild-type control mice were scanned with DPC imaging with an isotropic resolution of 15 μm. The coronary artery vessel walls were segmented in the DPC datasets to assess their thickness, and histological staining was performed at the level of atherosclerotic plaques. The DPC imaging allowed for the visualization of complex structures such as the coronary arteries and their branches, the thin fibrous cap of atherosclerotic plaques as well as the chordae tendineae. The coronary vessel wall thickness ranged from 37.4 ± 5.6 μm in proximal coronary arteries to 13.6 ± 3.3 μm in distal branches. No consistent differences in coronary vessel wall thickness were detected between the wild-type and atherosclerotic hearts in this proof-of-concept study, although the standard deviation in the atherosclerotic mice was higher in most segments, consistent with the observation of occasional focal vessel wall thickening. Overall, DPC imaging of the cardiovascular system of the mice allowed for a simultaneous detailed 3D morphological assessment of both large structures and microscopic details.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Several guidelines recommend computed tomography scans for populations with high-risk for lung cancer. The number of individuals evaluated for peripheral pulmonary lesions (PPL) will probably increase, and with it non-surgical biopsies. Associating a guidance method with a target confirmation technique has been shown to achieve the highest diagnostic yield, but the utility of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance without a guide sheath has not been reported. METHODS: We conducted a retrospective analysis of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy procedures for the investigation of PPL performed by experienced bronchoscopists with no specific previous training in this particular technique. Operator learning curves and radiological predictors were assessed for all consecutive patients examined during the first year of application of the technique. RESULTS: Fifty-one PPL were investigated. Diagnostic yield and visualization yield were 72.5 and 82.3% respectively. The diagnostic yield was 64.0% for PPL ≤20mm, and 80.8% for PPL>20mm. No false-positive results were recorded. The learning curve of all diagnostic tools showed a DY of 72.7% for the first sub-group of patients, 81.8% for the second, 72.7% for the third, and 81.8% for the last. CONCLUSION: Bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance is safe and simple to perform, even without specific prior training, and diagnostic yield is high for PPL>and ≤20mm. Based on these findings, this method could be introduced as a first-line procedure for the investigation of PPL, particularly in centers with limited resources.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

While the overall incidence of myocardial infarction (MI) has been decreasing since 2000 [1], there is an increasing number of younger patients presenting with MI [2]. Few studies have focused on MI in very young patients, aged 35 years or less, as they only account for a minority of all patients with myocardial infarction [3]. According to the age category, MI differs in presentation, treatment and outcome, as illustrated in table 1. Echocardiography is considered mandatory according to scientific guidelines in the management and diagnosis of MI [4,5,6]. However, new imaging techniques such as cardiac magnetic resonance (CMR) and computed tomography (CT) are increasingly performed and enable further refinement of the diagnosis of MI. These techniques allow, in particular, precise location and quantification of MI. In this case, MI was located to the septum, which is an unusual presentation of MI. The incidence of pulmonary embolism (PE) has also increased in young patients over the past years [7]. Since symptoms and signs of PE may be non-specific, establishing its diagnosis remains a challenge [8]. Therefore, PE is one of the most frequently missed diagnosis in clinical medicine. Because of the widespread use of CT and its improved visualization of pulmonary arteries, PE may be discovered incidentally [9]. In the absence of a congenital disorder, multiple and/or simultaneous disease presentation is uncommon in the young. We report the rare case of a 35 year old male with isolated septal MI and simultaneous PE. The diagnosis of this rare clinical entity was only possible by means of newer imaging techniques.