34 resultados para Ultrasonic transducers
em Université de Lausanne, Switzerland
Resumo:
OBJECTIVE: : To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN: : In vitro, laboratory study. SETTING: : Research laboratory of a university hospital. INTERVENTIONS: : Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested in three nebulization modes in a nonhumidified bench model mimicking the ventilatory pattern of a 10-kg infant. The amounts of albuterol deposited on the inspiratory filters (inhaled drug) at the end of the endotracheal tube, on the expiratory filters, and remaining in the nebulizers or in the ventilator circuit were determined. Particle size distribution of the nebulizers was also measured. MEASUREMENTS AND MAIN RESULTS: : The inhaled drug was 2.8% ± 0.5% for the jet nebulizer, 10.5% ± 2.3% for the ultrasonic nebulizer, and 5.4% ± 2.7% for the vibrating-mesh nebulizer in intermittent nebulization during the inspiratory phase (p < 0.01). The most efficient nebulizer was the vibrating-mesh nebulizer in continuous nebulization (13.3% ± 4.6%, p < 0.01). Depending on the nebulizers, a variable but important part of albuterol was observed as remaining in the nebulizers (jet and ultrasonic nebulizers), or being expired or lost in the ventilator circuit (all nebulizers). Only small particles (range 2.39-2.70 µm) reached the end of the endotracheal tube. CONCLUSIONS: : Important differences between nebulizer types and nebulization modes were seen for albuterol deposition at the end of the endotracheal tube in an in vitro pediatric ventilator-lung model. New aerosol devices, such as ultrasonic and vibrating-mesh nebulizers, were more efficient than the jet nebulizer.
Resumo:
A new plastic self-expanding Smartcanula (Smartcanula LLC, Lausanne, Switzerland) is designed for central insertion and prevention of caval collapse. The objective of our work is to assess the influence of the new design on atrial chatter. Caval collapse over the entire caval axis, right atrial, hepatic, renal vein, and iliac vein is realized in drainage tubes with holes at 5 cm distance intervals. Smartcanulas with various lengths (26 cm [= right atrial], 34 cm [= hepatic], 43 cm [= renal], and 53 cm [= iliac]) versus two-stage cannulas are compared. Pressure drop (ΔP) is measured using Millar pressure-transducers. Flow rate (Q) is measured using an ultrasonic flow meter. Cannula resistance is defined as the ΔP/Q ratio. Data display and recording are controlled using LabView virtual instruments. At an 88 cm height differential, Q values are 8.69 and 6.8 l/min, and ΔP/Q ratios are 0.63 and 1.28 for the 26-cm Smartcanula and the reference cannula, respectively. The 34-cm Smartcanula showed 8.89 l/min and 0.6 ΔP/Q ratio vs. 7.59 l/min and 0.9 for the control cannula (P < 0.05). The 43-cm and 53-cm Smartcanulas showed Q values of 9.04 and 8.81 l/min, respectively, and ΔP/Q2 ratio of 0.6. The Smartcanula outperforms the two-stage cannula, and direct cannula insertion without guide wire is effective.
Resumo:
OBJECTIVE: Bench evaluation of the hydrodynamic behavior of venous cannulas is a valuable technique for the analysis of their performance during cardiopulmonary bypass (CPB). The aim of this study was to investigate the effect of the internal diameter of the extracorporeal connecting tube of venous cannulas on flow rate (Q), pressure drop (delta P), and cannula resistance (delta P/Q²) values, using a computer assisted test bench.¦METHODS: An in vitro circuit was set up with silicone tubing between the test cannula encased in a movable reservoir, and a static reservoir. The delta P, defined as the difference between the drainage pressure and the preload pressure, was measured using high-fidelity Millar pressure transducers. Q was measured using an ultrasonic flowmeter. Data display and data recording were controlled using virtual instruments in a stepwise fashion.¦RESULTS: The 27 F smartcanula® with a 9 mm connecting tube diameter showed 17% less resistance compared to that with an 8 mm connecting tube diameter. Q values were 7.22±0.1 and 7.81±0.04 L/min for cannulas with 8 mm and 9 mm connecting tube diameters, respectively. The delta P/Q² ratio values were 72% lower for the Medtronic cannula with a 9 mm connecting tube diameter compared to that with an 8 mm connecting tube diameter. Q values for the Medtronic cannula were 3.94±0.23 and 6.58±0.04 L/min with 8 mm and 9 mm connecting tube diameters, respectively. The 27 F smartcanula® showed 13% more flow rate compared to the 28 F Medtronic cannula using the unpaired Student t-test (p<0.0001).¦CONCLUSIONS: Our results demonstrated that Q was increased but delta P and delta P/Q² values were significantly decreased when the connecting tube diameter was increased for venous cannulas. The connecting tube diameter significantly affected the resistance to liquid flow through the cannula. Smartcanulas® outperform Medtronic cannulas.
Resumo:
BACKGROUND: For over 50 years, radiocephalic wrist arteriovenous fistulae (RCAVF) have been the primary and best vascular access for haemodialysis. Nevertheless, early failure due to thrombosis or non-maturation is a major complication resulting in their abandonment. This prospective study was designed to investigate the predictive value of intra-operative blood flow on early failure of primary RCAVF before the first effective dialysis. METHODS: We enrolled patients undergoing creation of primary RCAVF for haemodialysis based on the pre-operative ultrasound vascular mapping discussed in a multidisciplinary approach. Intra-operative blood flow measurement was systematically performed once the anastomosis had been completed using a transit-time ultrasonic flowmeter. During the follow-up, blood flow was estimated by colour flow ultrasound at various intervals. Any events related to the RCAVF were recorded. RESULTS: Autogenous RCAVFs (n = 58) in 58 patients were constructed and followed up for an average of 30 days. Thrombosis and non-maturation occurred in eight (14%) and four (7%) patients, respectively. The intra-operative blood flow in functioning RCAVFs was significantly higher compared to non-functioning RCAVFs (230 vs 98 mL/min; P = 0.007), as well as 1 week (753 vs 228 mL/min; P = 0.0008) and 4 weeks (915 vs 245 mL/min, P < 0.0001) later. Blood flow volume measurements with a cut-off value of 120 mL/min had a sensitivity of 67%, specificity of 75% and positive predictive value of 91%. CONCLUSIONS: Blood flow <120 mL has a good predictive value for early failure in RCAVF. During the procedure, this cut-off value may be used to select appropriately which RCAVF should be investigated in the operation theatre in order to correct in real time any abnormality.
Resumo:
For several decades mechanical properties of shallow formations (soil) obtained by sonic to ultrasonic wave testing were reported to be greater than those based on mechanical tests. The present article relying on a statistical analysis of more than 300 tests shows that elastic moduli of the soil can indeed be obtained from (ultra)sonic tests and that they are identical to those resulting from mechanical tests.
Resumo:
AIM: To discuss the use of new ultrasonic techniques that make it possible to visualize elastic (carotid) and muscular (radial) capacitance arteries non-invasively. RESULTS OF DATA REVIEW: Measurements of carotid wall thickness and the detection of atheromas are related to arterial pressure, to other risk factors and to the risk of subsequent complications. The use of high-frequency ultrasound (7.5-10 MHz), measurements of far wall thicknesses in areas free of atheromas at end-diastole (by ECG gating or pressure waveform recording) and descriptions of the size and characteristics of atherosclerotic plaques allow a non-invasive assessment of vascular hypertrophy and atherosclerosis in hypertensive patients. CONCLUSIONS: Careful attention to methodologic and physiologic factors is needed to provide accurate information about the anatomy of the dynamically pulsating arterial tree.
Resumo:
Ventricular assist devices (VADs) are used in treatment for terminal heart failure or as a bridge to transplantation. We created biVAD using the artificial muscles (AMs) that supports both ventricles at the same time. We developed the test bench (TB) as the in vitro evaluating system to enable the measurement of performance. The biVAD exerts different pressure between left and right ventricle like the heart physiologically does. The heart model based on child's heart was constructed in silicone. This model was fitted with the biVAD. Two pipettes containing water with an ultrasonic sensor placed on top of each and attached to ventricles reproduced the preload and the after load of each ventricle by the real-time measurement of the fluid height variation proportionally to the exerted pressure. The LabVIEW software extrapolated the displaced volume and the pressure generated by each side of our biVAD. The development of a standardized protocol permitted the validation of the TB for in vitro evaluation, measurement of the performances of the AM biVAD herein, and reproducibility of data.
Resumo:
Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.
Resumo:
BACKGROUND: Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METHODS: The following nebulizers were tested: Sidestream Disposable jet nebulizer, Multisonic Infra Control ultrasonic nebulizer, and the Aerogen Pro and Aerogen Solo vibrating mesh nebulizers. Aerosol duration, temperature, and drug solution osmolality were measured during nebulization. Albuterol delivery was measured by a high-performance liquid chromatography system with fluorometric detection. The droplet size distribution was analyzed with a laser granulometer. RESULTS: The ultrasonic nebulizer was the fastest device based on the duration of nebulization; the jet nebulizer was the slowest. Solution temperature decreased during nebulization when the jet nebulizer and vibrating mesh nebulizers were used, but it increased with the ultrasonic nebulizer. Osmolality was stable during nebulization with the vibrating mesh nebulizers, but increased with the jet nebulizer and ultrasonic nebulizer, indicating solvent evaporation. Albuterol delivery was 1.6 and 2.3 times higher with the ultrasonic nebulizer and vibrating mesh nebulizers devices, respectively, than with the jet nebulizer. Particle size was significantly higher with the ultrasonic nebulizer. CONCLUSIONS: The in vitro model was effective for comparing nebulizer types, demonstrating important differences between nebulizer types. The new devices, both the ultrasonic nebulizers and vibrating mesh nebulizers, delivered more aerosolized drug than traditional jet nebulizers.
Resumo:
Amplification of the epidermal growth factor receptor (EGFR) gene is one of the most common oncogenic alterations in glioblastoma (45%) making it a prime target for therapy. However, small molecule inhibitors of the EGFR tyrosine kinase showed disappointing efficacy in clinical trials for glioblastoma. Here we aimed at investigating the molecular effects of the tyrosine kinase inhibitor gefitinib on the EGFR signaling pathway in human glioblastoma. Twenty-two patients selected for reoperation of recurrent glioblastoma were treated within a phase II trial for 5 days with 500 mg gefitinib before surgery followed by postoperative gefitinib until recurrence. Resected glioblastoma tissues exhibited high concentrations of gefitinib (median, 4.1 μg/g), 20 times higher than respective plasma. EGFR-pathway activity was evaluated with phosphorylation-specific assays. The EGFR was efficiently dephosphorylated in treated patients as compared to a control cohort of 12 patients. However, no significant effect on 12 pathway constituents was detected. In contrast, in vitro treatment of a glioblastoma cell line, BS-153, with endogenous EGFRwt amplification and EGFRvIII expression resulted not only in dephosphorylation of the EGFR, but also of key regulators in the pathway such as AKT. Treating established xenografts of the same cell line as an in vivo model showed dephosphorylation of the EGFR without affecting downstream signal transductors, similar to the human glioblastoma. Taken together, gefitinib reaches high concentrations in the tumor tissue and efficiently dephosphorylates its target. However, regulation of downstream signal transducers in the EGFR pathway seems to be dominated by regulatory circuits independent of EGFR phosphorylation.
Resumo:
Malnutrition, a risk factor for osteoporotic fractures, is frequent in elderly people and, is underdiagnosed and undertreated. There are only few studies on the nutritional status of elderly people in Europe. The Mini Nutritional Assessment (MNA) is a non invasive and validated questionnaire to evaluate nutritional status in elderly people, classified in three groups: 1 degree score < 17: malnourished, 2 degrees score >17 and < 24: at risk of malnutrition, 3 degrees score >24: well-nourished, with a maximum of 30 points. Quantitative ultrasound of bone (QUS) is a method for assessing quality of bone which can be easily performed in nursing homes. Therefore, these two tests allowed to study the relationships between nutritional status and ultrasonic parameters of bone in 78 institutionalized women aged 86 +/- 6 years, living in 11 nursing homes around Lausanne (Switzerland). All were assessed by the MNA, had a measurement of the tricipital skin fold and of the grip strength. Functional status was evaluated by the scale "Activity of Daily Living" (ADL), and serum albumin level was measured when permitted. All had QUS of the calcaneus (with an Achilles, GE Lunar). The measured parameters are the Broadband Ultrasound Attenuation (BUA), attenuation of a band of ultrasonic frequencies through the medium, expressed in dB/MHz, and the Speed of Sound (SOS), speed of the ultrasounds through the medium, expressed in m/s. A third parameter, the stiffness index (SI), expressed as a percentage of the values obtained by the manufacturer in a young population and derived from BUA and SOS, was calculated automatically : SI = (0.67xBUA) + (0.28xSOS) - 420, expressed in percent compared to a young adult population (%YA). Fifteen percent of the women were undernourished and 58% were at risk of malnutrition. As expected, compared with the well-nourished minority, undernourished subjects had significant lower body mass index (BMI), tricipital skin fold (TSF), ADL score and albumin level (p < 0,01). The subjects "at risk of malnutrition" had significant lower BMI, ADL score (p < 0.01), tricipital skin fold and serum albumin (p < 0.05). Ultrasound parameters were low independently of the nutritional status. MNA score correlated significantly with tricipital skin fold (r = 0.508, p < 0.01), ADL (r = 0.538, p < 0.01) and albumin serum level (r = 0.409, p = 0.01). There was a trend for a correlation between the MNA and the ultrasound parameter BUA (r = 0.207, p = 0.07), whereas no correlation was found with SOS and SI. A multivariate analysis showed that tricipital skin fold and ADL explained 61% of the variance of the MNA. In conclusion, using simple and non invasive methods, this study showed that malnutrition and osteoporosis are frequent in institutionalized elderly persons in our country, and the ultrasound parameters are influenced by many others factors in addition to nutrition, especially at this age and in elderly residents of nursing homes.
Resumo:
PURPOSE: The origin of the slow component is not fully understood. The mechanical hypothesis is one of the potential factors, because an increase in external mechanical work with fatigue was previously reported for a constant velocity run. The purpose of this study was to determine whether a change in mechanical work could occur during the development of the VO2 slow component under the effect of fatigue. METHODS: Twelve regional-level competitive runners performed a square-wave transition, corresponding to 95% of the speed associated with peak VO2 obtained during an incremental test. The VO2 response was fit with a classical model including two exponential functions. A specific treadmill with three-dimensional force transducers was used to measure the ground reaction force. Kinetic work (W(kin)), potential work (W(pot)), external work (W(ext)), and an index of internal work (W(int)) per unit of distance were quantified continuously. RESULTS: During the slow component of VO2, a significant increase in W (P< 0.01), no change in W, and a significant decrease in W and W index (P< 0.05, P< 0.001, respectively) were observed. CONCLUSION: The present study showed that the slow component of VO2 did not result partly from a change in mechanical work under the effect of fatigue. Nevertheless, the decrease in stride frequency (P< 0.001) and contact time (P< 0.001) suggested an alternative mechanical explanation. The slow component during running may be due to the cost of generating force or to alterations in the storage and recoil of elastic energy, and not to the external mechanical work.
Resumo:
To assess the behavior of the arterial wall in hypertensive patients, we developed a noninvasive ultrasonic device. Simultaneous recordings of internal diameter and blood pressure over the whole cardiac cycle are used to establish compliance-pressure curves. Blood pressure, which is a co-determinant of compliance, is thus taken into account. This method allows one to compare arteries from patients with different blood pressures. Arterial compliance and distensibility were first investigated in healthy young volunteers administered either lisinopril (20 mg), atenolol (100 mg) or nitrendipine (20 mg) once a day. After 8 days of treatment, only lisinopril was found to increase arterial compliance. Subsequently, we compared arterial diameter- and distensibility-pressure curves from newly diagnosed and untreated hypertensive patients with those of matched normotensive control patients. Diameter-pressure curves did not differ significantly between the groups and distensibility was not reduced. Similar findings were later obtained in an animal model, when mechanical properties of carotid arteries were compared between spontaneously hypertensive rats and normotensive counterparts (Wistar-Kyoto rats). These results, although interesting by providing noninvasive information on the elastic response of the wall, call for further development of the technique to be able to measure arterial wall thickness. Stress-strain relationship could ultimately be established to thoroughly characterize physical properties of blood vessel walls.