130 resultados para Ultra-sonografia intra-operatória

em Université de Lausanne, Switzerland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Therapeutic drug monitoring (TDM) may contribute to optimizing the efficacy and safety of antifungal therapy because of the large variability in drug pharmacokinetics. Rapid, sensitive, and selective laboratory methods are needed for efficient TDM. Quantification of several antifungals in a single analytical run may best fulfill these requirements. We therefore developed a multiplex ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method requiring 100 μl of plasma for simultaneous quantification within 7 min of fluconazole, itraconazole, hydroxyitraconazole, posaconazole, voriconazole, voriconazole-N-oxide, caspofungin, and anidulafungin. Protein precipitation with acetonitrile was used in a single extraction procedure for eight analytes. After reverse-phase chromatographic separation, antifungals were quantified by electrospray ionization-triple-quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. Deuterated isotopic compounds of azole antifungals were used as internal standards. The method was validated based on FDA recommendations, including assessment of extraction yields, matrix effect variability (<9.2%), and analytical recovery (80.1 to 107%). The method is sensitive (lower limits of azole quantification, 0.01 to 0.1 μg/ml; those of echinocandin quantification, 0.06 to 0.1 μg/ml), accurate (intra- and interassay biases of -9.9 to +5% and -4.0 to +8.8%, respectively), and precise (intra- and interassay coefficients of variation of 1.2 to 11.1% and 1.2 to 8.9%, respectively) over clinical concentration ranges (upper limits of quantification, 5 to 50 μg/ml). Thus, we developed a simple, rapid, and robust multiplex UPLC-MS/MS assay for simultaneous quantification of plasma concentrations of six antifungals and two metabolites. This offers, by optimized and cost-effective lab resource utilization, an efficient tool for daily routine TDM aimed at maximizing the real-time efficacy and safety of different recommended single-drug antifungal regimens and combination salvage therapies, as well as a tool for clinical research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RATIONALE: The aim of the work was to develop and validate a method for the quantification of vitamin D metabolites in serum using ultra-high-pressure liquid chromatography coupled to mass spectrometry (LC/MS), and to validate a high-resolution mass spectrometry (LC/HRMS) approach against a tandem mass spectrometry (LC/MS/MS) approach using a large clinical sample set. METHODS: A fast, accurate and reliable method for the quantification of the vitamin D metabolites, 25-hydroxyvitamin D2 (25OH-D2) and 25-hydroxyvitamin D3 (25OH-D3), in human serum was developed and validated. The C3 epimer of 25OH-D3 (3-epi-25OH-D3) was also separated from 25OH-D3. The samples were rapidly prepared via a protein precipitation step followed by solid-phase extraction (SPE) using an HLB μelution plate. Quantification was performed using both LC/MS/MS and LC/HRMS systems. RESULTS: Recovery, matrix effect, inter- and intra-day reproducibility were assessed. Lower limits of quantification (LLOQs) were determined for both 25OH-D2 and 25OH-D3 for the LC/MS/MS approach (6.2 and 3.4 µg/L, respectively) and the LC/HRMS approach (2.1 and 1.7 µg/L, respectively). A Passing & Bablok fit was determined between both approaches for 25OH-D3 on 662 clinical samples (1.11 + 1.06x). It was also shown that results can be affected by the inclusion of the isomer 3-epi-25OH-D3. CONCLUSIONS: Quantification of the relevant vitamin D metabolites was successfully developed and validated here. It was shown that LC/HRMS is an accurate, powerful and easy to use approach for quantification within clinical laboratories. Finally, the results here suggest that it is important to separate 3-epi-25OH-D3 from 25OH-D3. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient &gt; or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Posaconazole (POS) is a new antifungal agent for prevention and therapy of mycoses in immunocompromised patients. Variable POS pharmacokinetics after oral dosing may influence efficacy: a trough threshold of 0.5 ?g/ml has been recently proposed. Measurement of POS plasma concentrations by complex chromatographic techniques may thus contribute to optimize prevention and management of life-threatening infections. No microbiological analytical method is available. The objective of this study was to develop and validate a new simplified ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method and a sensitive bioassay for quantification of POS over the clinical plasma concentration range. The UPLC-MS/MS equipment consisted of a triple quadrupole mass spectrometer, an electrospray ionization (ESI) source, and a C(18) analytical column. The Candida albicans POS-hypersusceptible mutant (MIC of 0.002 ?g/ml) ?cdr1 ?cdr2 ?flu ?mdr1 ?can constructed by targeted deletion of multidrug efflux transporters and calcineurin genes was used for the bioassay. POS was extracted from plasma by protein precipitation with acetonitrile-methanol (75%/25%, vol/vol). Reproducible standard curves were obtained over the range 0.014 to 12 (UPLC-MS/MS) and 0.028 to 12 ?g/ml (bioassay). Intra- and interrun accuracy levels were 106% ± 2% and 103% ± 4% for UPLC-MS/MS and 102% ± 8% and 104% ± 1% for bioassay, respectively. The intra- and interrun coefficients of variation were 7% ± 4% and 7% ± 3% for UPLC-MS/MS and 5% ± 3% and 4% ± 2% for bioassay, respectively. An excellent correlation between POS plasma concentrations measured by UPLC-MS/MS and bioassay was found (concordance, 0.96). In 26 hemato-oncological patients receiving oral POS, 27/69 (39%) trough plasma concentrations were lower than 0.5 ?g/ml. The UPLC-MS/MS method and sensitive bioassay offer alternative tools for accurate and precise quantification of the plasma concentrations in patients receiving oral posaconazole.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Hypotension, a common intra-operative incident, bears an important potential for morbidity. It is most often manageable and sometimes preventable, which renders its study important. Therefore, we aimed at examining hospital variations in the occurrence of intra-operative hypotension and its predictors. As secondary endpoints, we determined to what extent hypotension relates to the risk of post-operative incidents and death. METHODS: We used the Anaesthesia Databank Switzerland, built on routinely and prospectively collected data on all anaesthesias in 21 hospitals. The three outcomes were assessed using multi-level logistic regression models. RESULTS: Among 147,573 anaesthesias, hypotension ranged from 0.6% to 5.2% in participating hospitals, and from 0.3% up to 12% in different surgical specialties. Most (73.4%) were minor single events. Age, ASA status, combined general and regional anaesthesia techniques, duration of surgery and hospitalization were significantly associated with hypotension. Although significantly associated, the emergency status of the surgery had a weaker effect. Hospitals' odds ratios for hypotension varied between 0.12 and 2.50 (P < or = 0.001), even after adjusting for patient and anaesthesia factors, and for type of surgery. At least one post-operative incident occurred in 9.7% of the procedures, including 0.03% deaths. Intra-operative hypotension was associated with a higher risk of post-operative incidents and death. CONCLUSION: Wide variations remain in the occurrence of hypotension among hospitals after adjustment for risk factors. Although differential reporting from hospitals may exist, variations in anaesthesia techniques and blood pressure maintenance may also have contributed. Intra-operative hypotension is associated with morbidities and sometimes death, and constant vigilance must thus be advocated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential and applicability of UHPSFC-MS/MS for anti-doping screening in urine samples were tested for the first time. For this purpose, a group of 110 doping agents with diverse physicochemical properties was analyzed using two separation techniques, namely UHPLC-MS/MS and UHPSFC-MS/MS in both ESI+ and ESI- modes. The two approaches were compared in terms of selectivity, sensitivity, linearity and matrix effects. As expected, very diverse retentions and selectivities were obtained in UHPLC and UHPSFC, proving a good complementarity of these analytical strategies. In both conditions, acceptable peak shapes and MS detection capabilities were obtained within 7min analysis time, enabling the application of these two methods for screening purposes. Method sensitivity was found comparable for 46% of tested compounds, while higher sensitivity was observed for 21% of tested compounds in UHPLC-MS/MS and for 32% in UHPSFC-MS/MS. The latter demonstrated a lower susceptibility to matrix effects, which were mostly observed as signal suppression. In the case of UHPLC-MS/MS, more serious matrix effects were observed, leading typically to signal enhancement and the matrix effect was also concentration dependent, i.e., more significant matrix effects occurred at the lowest concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs: Etude prospective sur l'efficacité de la chimio-perfusion super-sélective avec Melphalan dans l'artère ophtalmique en tant qu'agent tumoricide chez l'enfantatteint de rétinoblastome avancé, pour éviter l'énucléation chirurgicale et/ou la radiothérapie externe. Matériels et méthodes: 19 enfants (âge moyen 25 mois) atteints de rétinoblastome de groupe D ont reçu 1 à 3 séances d'administration intra-artérielle de Melphalan (0,35 mg/kg) dans l'artère ophtalmique sous anesthésie générale. Au total 48 procédures ont été réalisées. Chaque séance était associée à une injection intra-vitréenne deMelphalan, ainsi qu'à une thermothérapie et/ou une cryothérapie. Résultats: Le traitement a été effectué avec succès chez 17/19 enfants avec une régression importante du volume tumoral. L'énucléation ainsi que la radiothérapie externeont pu être évitées dans 15/17 enfants, sur un suivi moyen d'une année. Aucune complication systémique ou thromboembolique n'a été observée. Lescomplications locales ont comporté 2 décollements de la rétine, 5 oedèmes conjonctivaux et palpébraux, 1 cas de pigmentation cutanée locale, 1 vasospasmetransitoire de l'artère carotide interne et 2 cas d'artériopathie occlusive choroïdienne sectorielle . Conclusion: L'administration intra-artérielle de Melphalan s'avère être très efficace dans les cas avancés de rétinoblastome chez l'enfant, aussi bien comme techniquecurative que pour éviter l'énucléation et/ou la radiothérapie externe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clenbuterol is a β2 agonist agent with anabolic properties given by the increase in the muscular mass in parallel to the decrease of the body fat. For this reason, the use of clenbuterol is forbidden by the World Anti-Doping Agency (WADA) in the practice of sport. This compound is of particular interest for anti-doping authorities and WADA-accredited laboratories due to the recent reporting of risk of unintentional doping following the eating of meat contaminated with traces of clenbuterol in some countries. In this work, the development and the validation of an ultra-high pressure liquid chromatography coupled to electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS) method for the quantification of clenbuterol in human urine is described. The analyte was extracted from urine samples by liquid-liquid extraction (LLE) in basic conditions using tert butyl-methyl ether (TBME) and analyzed by UHPLC-MS/MS with a linear gradient of acetonitrile in 9min only. The simple and rapid method presented here was validated in compliance with authority guidelines and showed a limit of quantification at 5pg/mL and a linearity range from 5pg/mL to 300pg/mL. Good trueness (85.8-105%), repeatability (5.7-10.6% RSD) and intermediate precision (5.9-14.9% RSD) results were obtained. The method was then applied to real samples from eighteen volunteers collecting urines after single oral doses administration (1, 5 and 10μg) of clenbuterol-enriched yogurts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé : La présente étude vise à déterminer quels sont les facteurs permettant de valider de nouvelles échelles de personnalité spécifiques à la relation intra-couple construites sur la base de profils de personnalité en auto- et hétéro-évaluation. Pour ce faire, nous avons défini des critères sociologiques (par exemple âge, niveau socioprofessionnel, nombre de relations passées), des critères psychologiques (satisfaction conjugale) et des critères biologiques (distance génétique et préférence d'odeurs) afin de vérifier s'ils sont susceptibles de valider les six échelles de personnalité intra-couples inédites que nous avons construites dans le cadre de cette recherche de doctorat. Notre échantillon se compose de 106 couples mariés et de 60 jeunes couples non mariés, qui ont chacun complété le test de personnalité L.A. B. E. L. (F Gendre & R. Capel), l'Échelle d'Ajustement Dyadique (Spanier, 1976) ainsi qu'un test génétique pour une partie d'entre eux.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs: Une phase hyperalgique dans les 4 heures post-examen arthrographique est maintenant reconnue dans la littérature. Comment s'en amender ? Nous comparonsl'absence d'anesthésique à l'adjonction de deux différents anesthésiques locaux intra-articulaires(rapidocaïne/bupivacaïne) lors d'arthro-TDM/IRM. Matériels et méthodes: Après approbation du comité d'éthique, étude prospective chez 150 patients répartis aléatoirement en trois groupes : 1) sans anesthésique intra-articulaire, 2)rapidocaïne 1%, 3) bupivacaïne 0,25%. Recueil du score EVA (0-10) aux 5 temps suivants : avant injection (score de base), puis 20 minutes, 4 heures, 24 heureset 7 jours après la procédure. Résultats: Le pic douloureux maximal se trouve à 4h après la procédure (idem littérature). La douleur augmente en moyenne de 1,60 unités 4h après la procédure pour legroupe 1, de 1,22 unités pour le groupe 2 et de 0,29 unités pour le groupe 3. La différence entre les groupes 1 et 3 est statistiquement significative (p=0,002 -Tests ANOVA et de Sidak). Elle n'est pas significative entre les groupes 1 et 2 (p=0,536). La comparaison rapidocaïne et bupivacaïne est moins concluante(p=0,065). Conclusion: L'adjonction de bupivacaïne intra-articulaire devrait être réalisée lors d'examens arthrographiques, surtout afin d'améliorer le confort du patient mais aussi pourfavoriser son immobilité lors de l'acquisition des images TDM ou IRM .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le retard de croissance intra-utérin (RCIU) est défini par une taille et un poids inférieurs au P10 pour l'âge gestationnel. Il est caractérisé, entre autre par une altération de la croissance foetale aboutissant à une résistance à l'hormone de croissance (HC). Bien que la majorité des sujets présente un certain rattrapage en taille, certains développent un retard de croissance ultérieur permanent. L'idée est donc née de traiter ces sujets par haute dose d'HC biosynthétique. La question des risques d'un tel traitement s'est posée en raison de l'effet diabétogène de l'HC et des modifications qu'elle peut induire sur la masse maigre, la masse grasse et la densité osseuse. Le but de l'étude a été d'évaluer l'impact sur la croissance et sur le volet métabolique. Dix enfants prépubères ayant présenté un RCIU sans croissance de rattrapage spontanée ont été traités par HC recombinante à des doses supra physiologiques (53-67 g/kg/jour). La taille, le poids, la taille assise ont été mesurés et des dosages d'IGF1, IGFBP3, glycémie et insuline ont été faits sur une base semestrielle alors qu'une densitométrie osseuse a été faite annuellement sur une période de 3 ans. Le gain en taille a été spectaculaire (+ 1.78 DS), correspondant à plus de 10 cm (p < 0.001). Sous traitement, l'insulinémie et le HOMA ont augmenté sans que ces augmentations soient significatives. La tolérance glucidique est restée dans la norme au prix d'une augmentation de la sécrétion d'insuline. La masse grasse a diminué alors que la masse maigre et la densité osseuse ont augmenté de façon significative. Ces résultats correspondent aux travaux d'autres groupes. Il reste à démontrer que l'hyperinsulinisme transitoire induit par l'HC n'ait pas d'effet néfaste à long terme et en particulier sur le risque de développer ou aggraver un syndrome métabolique à l'âge adulte.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: For over 50 years, radiocephalic wrist arteriovenous fistulae (RCAVF) have been the primary and best vascular access for haemodialysis. Nevertheless, early failure due to thrombosis or non-maturation is a major complication resulting in their abandonment. This prospective study was designed to investigate the predictive value of intra-operative blood flow on early failure of primary RCAVF before the first effective dialysis. METHODS: We enrolled patients undergoing creation of primary RCAVF for haemodialysis based on the pre-operative ultrasound vascular mapping discussed in a multidisciplinary approach. Intra-operative blood flow measurement was systematically performed once the anastomosis had been completed using a transit-time ultrasonic flowmeter. During the follow-up, blood flow was estimated by colour flow ultrasound at various intervals. Any events related to the RCAVF were recorded. RESULTS: Autogenous RCAVFs (n = 58) in 58 patients were constructed and followed up for an average of 30 days. Thrombosis and non-maturation occurred in eight (14%) and four (7%) patients, respectively. The intra-operative blood flow in functioning RCAVFs was significantly higher compared to non-functioning RCAVFs (230 vs 98 mL/min; P = 0.007), as well as 1 week (753 vs 228 mL/min; P = 0.0008) and 4 weeks (915 vs 245 mL/min, P < 0.0001) later. Blood flow volume measurements with a cut-off value of 120 mL/min had a sensitivity of 67%, specificity of 75% and positive predictive value of 91%. CONCLUSIONS: Blood flow <120 mL has a good predictive value for early failure in RCAVF. During the procedure, this cut-off value may be used to select appropriately which RCAVF should be investigated in the operation theatre in order to correct in real time any abnormality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Validation is arguably the bottleneck in the diffusion magnetic resonance imaging (MRI) community. This paper evaluates and compares 20 algorithms for recovering the local intra-voxel fiber structure from diffusion MRI data and is based on the results of the "HARDI reconstruction challenge" organized in the context of the "ISBI 2012" conference. Evaluated methods encompass a mixture of classical techniques well known in the literature such as diffusion tensor, Q-Ball and diffusion spectrum imaging, algorithms inspired by the recent theory of compressed sensing and also brand new approaches proposed for the first time at this contest. To quantitatively compare the methods under controlled conditions, two datasets with known ground-truth were synthetically generated and two main criteria were used to evaluate the quality of the reconstructions in every voxel: correct assessment of the number of fiber populations and angular accuracy in their orientation. This comparative study investigates the behavior of every algorithm with varying experimental conditions and highlights strengths and weaknesses of each approach. This information can be useful not only for enhancing current algorithms and develop the next generation of reconstruction methods, but also to assist physicians in the choice of the most adequate technique for their studies.