146 resultados para Transthoracic echocardiography

em Université de Lausanne, Switzerland


Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: Transthoracic echocardiography (TTE) has been used clinically to disobstruct venous drainage cannula and to optimise placement of venous cannulae in the vena cava but it has never been used to evaluate performance capabilities. Also, little progress has been made in venous cannula design in order to optimise venous return to the heart lung machine. We designed a self-expandable Smartcanula (SC) and analysed its performance capability using echocardiography. METHODS: An epicardial echocardiography probe was placed over the SC or control cannula (CTRL) and a Doppler image was obtained. Mean (V(m)) and maximum (V(max)) velocities, flow and diameter were obtained. Also, pressure drop (DeltaP(CPB)) was obtained between the central venous pressure and inlet to venous reservoir. LDH and Free Hb were also compared in 30 patients. Comparison was made between the two groups using the student's t-test with statistical significance established when p<0.05. RESULTS: Age for the SC and CC groups were 61.6+/-17.6 years and 64.6+/-13.1 years, respectively. Weight was 70.3+/-11.6 kg and 72.8+/-14.4 kg, respectively. BSA was 1.80+/-0.2 m(2) and 1.82+/-0.2 m(2), respectively. CPB times were 114+/-53 min and 108+/-44 min, respectively. Cross-clamp time was 59+/-15 min and 76+/-29 min, respectively (p=NS). Free-Hb was 568+/-142 U/l versus 549+/-271 U/l post-CPB for the SC and CC, respectively (p=NS). LDH was 335+/-73 mg/l versus 354+/-116 mg/l for the SC and CC, respectively (p=NS). V(m) was 89+/-10 cm/s (SC) versus 63+/-3 cm/s (CC), V(max) was 139+/-23 cm/s (SC) versus 93+/-11 cm/s (CC) (both p<0.01). DeltaP(CPB) was 30+/-10 mmHg (SC) versus 43+/-13 mmHg (CC) (p<0.05). A Bland-Altman test showed good agreement between the two devices used concerning flow rate calculations between CPB and TTE (bias 300 ml+/-700 ml standard deviation). CONCLUSIONS: This novel Smartcanula design, due to its self-expanding principle, provides superior flow characteristics compared to classic two stage venous cannula used for adult CPB surgery. No detrimental effects were observed concerning blood damage. Echocardiography was effective in analysing venous cannula performance and velocity patterns.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A 5-year-old previously healthy boy was admitted for abdominal pain and vomiting. Physical examination showed tachypnoe (32/min), hepatomegaly and painful palpation of the upper right abdominal quadrant. Laboratory tests were normal except for elevated ammonium (202mcmol/l). Chest X-ray was performed, showing cardiomegaly and interstitial edema. Transthoracic echocardiography revealed dilated left cavities and LV hypertrophy together with a diffuse hypokinesia and LVEF of 30-40%. Diuretics and ACE-inhibitors were introduced. At that time, the differential diagnosis for the DCM included myocarditis, congenital or genetic, metabolic or autoimmune disease. The next day, the boy underwent cardiac magnetic resonance (CMR) examination, showing a severe dilatation of the LV with an end-diastolic diameter of 50mm and a volume of 150ml. LVEF was 20% with diffuse LV hypokinesia (Fig. 1). No late enhancement was present after Gadolinium injection, ruling out myocarditis. Further laboratory metabolic analysis indicated severely decreased total and free carnitin levels and low renal carnitin reabsorption, corroborating the diagnosis of primary carnitin deficiency (PCD). Carnitin substitution was initiated. The clinical condition rapidly improved. No symptoms of heart failure were present anymore. A follow-up CMR performed 9 months later confirmed the recovery. LV end-diastolic volume decreased from 150ml to 66ml, LVEF increased from 20% to 55% (Fig. 2). Late enhancement was absent after Gadolinum injection (Fig. 3).Carnitin is required for the transport of fatty acids from the cytosol into mitochondria during lipid breakdown. 75% of carnitin is obtained from food, 25% is endogenously synthesized. PCD is an autosomal recessive disorder resulting from impairment of a transporter activity, caused by mutation of the SLC22A5 gene. Incidence is about 1 in 40'000 newborns. Diagnosis is usually made at age 1 to 7. Three forms of PCD are described. In the form associated with cardiomyopathy, the disease is progressive and patient die from heart failure if not treated. Substitution of L-Carnitin leads to a dramatic improvement of disease course.This case underlines the crucial role of etiologic diagnostics in this reversible form of DCM. Early diagnostics and therapy are critical for the prognosis of the patient. This is furthermore an example of a role played by CMR in the diagnostic work-up of heart failure and its follow-up under therapy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Echocardiography is a key tool in the diagnosis of infective endocarditis. Although transthoracic echocardiography is the first step in the work-up, transoesophageal echocardiography is mandatory for the evaluation of the exact extent of the infectious process. Indeed, perivalvular abscess can fistulate towards different heart chambers, leading sometimes to critical clinical situations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Isolated ventricular non-compaction (IVNC) is a rare, congenital, unclassified cardiomyopathy characterized by prominent trabecular meshwork and deep recesses. Major clinical manifestations of IVNC are heart failure, atrial and ventricular arrhythmias, and thrombo-embolic events. We describe a case of a 69-year-old woman in whom the diagnosis of IVNC was discovered late, whereas former echocardiographic examinations were considered normal. She was known for systolic left ventricular dysfunction for 3 years and then became symptomatic (NYHA III). In the past, she suffered from multiple episodes of deep vein thrombosis and pulmonary embolism. Electrocardiogram revealed a wide QRS complex, and transthoracic echocardiography showed typical apical thickening of the left and right ventricular myocardial wall with two distinct layers. The ratio of non-compacted to compacted myocardium was >2:1. Cardiac MRI confirmed the echocardiographic images. Cerebral MRI revealed multiple ischaemic sequellae. In view of the persistent refractory, heart failure in medical treatment of patients with classical criteria for cardiac re-synchronization therapy, as well as the ventricular arrhythmias, a biventricular automatic intracardiac defibrillator (biventricular ICD) was implanted. The 2-year follow-up period was characterized by improvement of NYHA functional class from III to I and increasing in left ventricular function. We hereby present a case of IVNC with favourable outcome after biventricular ICD implantation. Cardiac re-synchronization therapy could be considered in the management of this pathology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Excessive mediastinal shift into the vacated thoracic cavity after pneumonectomy can result in dyspnea without hypoxemia by compression of the tracheobronchial tree, a phenomenon called postpneumonectomy syndrome. More rarely hypoxemia in upright position (platypnea-orthodeoxia syndrome, POS) after pneumonectomy can result from re-opening of an atrial right-to-left shunt through a patent foramen ovale (PFO) due to mediastinal distorsion. Review of literature also shows a unique report of pulmonary veins stenosis resulting in POS without intracardiac shunt after pneumonectomy. Methods: We report the case of a 32-year-old woman who presented POS 6 months after right pneumonectomy for destroyed lung post tuberculosis. Results: The patient described severe dyspnea disappearing when lying. SpO2 decreased from 94% when lying to 60% sitting. Transthoracic echocardiography (TTE) suspected a possible PFO. We first tried to highlight clinical repercussions of PFO by noninvasive exams. Hyperoxia shunt quantification was not tolerated because of increased dyspnea in sitting position. Contrast bubbles TTE was difficult because of the important mediastinal shift but identified only rare left heart bubbles with/without Valsalva both in lying and sitting position, excluding a significant right-to-left shunt. A lung perfusion scintigraphy (injection while sitting) confirmed the absence of systemic isotope uptake. Computed tomographic pulmonary angiography (angio-CT) revealed a stretched but not stenosed left main bronchus, while the shift of the heart into the right cavity was major. Pulmonary angiography did not show embolism but revealed compression of the inferior vena cava (IVC) with impaired venous return to the right heart, as well as compression of the left pulmonary veins. There was no arteriovenous shunt. Cardiac MRI showed torsion of IVC at the level of the diaphragm, and strong atrial contraction contributing to a passive filling of the RV, while the right ventricle was normal. Right catheterism showed major hemodynamic disturbances with negative diastolic pressure in right heart cavities (atrium -12 mm Hg ventricle pressure -7 mm Hg). SaO2 measured in the pulmonary artery decreased from 58% when lying to 45% sitting. Conclusion: We described here an exceedingly rare and complex mechanism explaining POS after right pneumonectomy. Mediastinal repositioning with a silicone breast implant of appropriate size has been scheduled.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: In patients with Kawasaki disease, serial evaluation of the distribution and size of coronary artery aneurysms (CAA) is necessary for risk stratification and therapeutic management. Although transthoracic echocardiography is often sufficient for this purpose initially, visualization of the coronary arteries becomes progressively more difficult as children grow. We sought to prospectively compare coronary magnetic resonance angiography (MRA) and x-ray coronary angiography findings in patients with CAA caused by Kawasaki disease. METHODS AND RESULTS: Six subjects (age 10 to 25 years) with known CAA from Kawasaki disease underwent coronary MRA using a free-breathing T2-prepared 3D bright blood segmented k-space gradient echo sequence with navigator gating and tracking. All patients underwent x-ray coronary angiography within a median of 75 days (range, 1 to 359 days) of coronary MRA. There was complete agreement between MRA and x-ray angiography in the detection of CAA (n=11), coronary artery stenoses (n=2), and coronary occlusions (n=2). Excellent agreement was found between the 2 techniques for detection of CAA maximal diameter (mean difference=0.4 +/- 0.6 mm) and length (mean difference=1.4 +/- 1.6 mm). The 2 methods showed very similar results for proximal coronary artery diameter (mean difference=0.2 +/- 0.5 mm) and CAA distance from the ostia (mean difference=0.1 +/- 1.5 mm). CONCLUSION: Free-breathing 3D coronary MRA accurately defines CAA in patients with Kawasaki disease. This technique may provide a non-invasive alternative when transthoracic echocardiography image quality is insufficient, thereby reducing the need for serial x-ray coronary angiography in this patient group.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND/AIMS: The present report examines a new pig model for progressive induction of high-grade stenosis, for the study of chronic myocardial ischemia and the dynamics of collateral vessel growth. METHODS: Thirty-nine Landrace pigs were instrumented with a novel experimental stent (GVD stent) in the left anterior descending coronary artery. Eight animals underwent transthoracic echocardiography at rest and under low-dose dobutamine. Seven animals were examined by nuclear PET and SPECT analysis. Epi-, mid- and endocardial fibrosis and the numbers of arterial vessels were examined by histology. RESULTS: Functional analysis showed a significant decrease in global left ventricular ejection fraction (24.5 +/- 1.6%) 3 weeks after implantation. There was a trend to increased left ventricular ejection fraction after low-dose dobutamine stress (36.0 +/- 6.6%) and a significant improvement of the impaired regional anterior wall motion. PET and SPECT imaging documented chronic hibernation. Myocardial fibrosis increased significantly in the ischemic area with a gradient from epi- to endocardial. The number of arterial vessels in the ischemic area increased and coronary angiography showed abundant collateral vessels of Rentrop class 1. CONCLUSION: The presented experimental model mimics the clinical situation of chronic myocardial ischemia secondary to 1-vessel coronary disease.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Limited data have been published on the normal size of the ascending aorta (AA) measured using transthoracic echocardiography (TTE). METHODS: AA diameters were measured in 1799 patients with normal cardiac findings on TTE and compared with the diameters of the sinus of Valsalva (SoV). RESULTS: Mean diameters in men and women, respectively, were 3.4 and 3.1 cm for the SoV and 3.2 and 3.0 cm for the AA. The sizes of the SoV and the AA showed strong correlations with age, age squared, and body surface area. The 5th and 95th percentile curves for the SoV and AA showed faster growth of diameters in early adulthood compared with old age. The dimensions of the SoV were larger than those of the AA (mean differences, 0.19 cm in men and 0.08 cm in women), and the difference between the SoV and AA was negatively correlated with age. CONCLUSION: The findings of this study stress the importance of indexing dimensions of the SoV and the AA to age and body surface area separately for men and women.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: There is considerable interindividual variability in pulmonary artery pressure among high-altitude (HA) dwellers, but the underlying mechanism is not known. At low altitude, a patent foramen ovale (PFO) is present in about 25% of the general population. Its prevalence is increased in clinical conditions associated with pulmonary hypertension and arterial hypoxemia, and it is thought to aggravate these problems. METHODS: We searched for a PFO (transesophageal echocardiography) in healthy HA dwellers (n = 22) and patients with chronic mountain sickness (n = 35) at 3,600 m above sea level and studied its effects (transthoracic echocardiography) on right ventricular (RV) function, pulmonary artery pressure, and vascular resistance at rest and during mild exercise (50 W), an intervention designed to further increase pulmonary artery pressure. RESULTS: The prevalence of PFO (32%) was similar to that reported in low-altitude populations and was not different in participants with and without chronic mountain sickness. Its presence was associated with RV enlargement at rest and an exaggerated increase in right-ventricular-to-right-atrial pressure gradient (25 ± 7 mm Hg vs 15 ± 9 mm Hg, P < .001) and a blunted increase in fractional area change of the right ventricle (3% [-1%, 5%] vs 7% [3%, 16%], P = .008) during mild exercise. CONCLUSIONS: These findings show, we believe for the first time, that although the prevalence of PFO is not increased in HA dwellers, its presence appears to facilitate pulmonary vasoconstriction and RV dysfunction during a mild physical effort frequently associated with daily activity. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT01182792; URL: www.clinicaltrials.gov.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alveolar echinococcosis is an invasive, tumor-like zoonosis, accidentally transmitted to humans. We present a case of recurrent inferior vena cava (IVC) syndrome due to alveolar echinococcosis and strongly suspected on transthoracic echocardiographic examination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous closure of patent foramen ovale (PFO) has been proposed as the treatment of choice for young high-risk patients who suffered cryptogenic stroke and/or peripheral paradoxical embolism. We sought to compare prospectively two different devices used for percutaneous PFO closure.Prospective data were collected on 40 high risk patients (females: 38%, mean age : 44 +/- 11 years, interatrial septal aneurysm >10 mm: 68%) who underwent percutaneous PFO closure after cryptogenic stroke (n = 38) or peripheral paradoxical embolism (n = 2). Chronologically, 20 patients were first treated by a PFO-Star (Cardia, Burnsville, MI) device. Then, 20 other patients received a Starflex occluder (NMT, Boston, MA). The primary endpoint was complete PFO closure at 6 months as assessed by transthoracic contrast echocardiography. Secondary endpoints were major peri- or post procedural complications and clinical recurrence at 1 year follow-up.Baseline clinical and anatomical characteristics were comparable for both groups. Complete PFO closure was observed in 50% (PFO-Star) and 90% (Starflex) of patients (p=0.001) respectively. Major peri-procedural complications occurred in the PFO-star group only: right-sided device thrombus (1 patient) and aorto-right atrial fistula (1 patient). At 1 year follow-up, no clinical recurrence occurred.In conclusion, despite the absence of clinical recurrence in this high-risk population with presumed paradoxical embolism, complete PFO closure at 6 months follow-up was significantly related to the type of closure device used

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Nasal continuous positive airways pressure (n-CPAP) is an effective treatment in premature infants with respiratory distress. The cardio-pulmonary interactions secondary to n-CPAP are well studied in adults, but less well described in premature infants. We postulated that there could be important interactions with regard to the patent ductus arteriosus (PDA). Methods: Prospective study, approved by the local ethic committee. Premature infants less than 32 weeks gestation, _7 days-old, needing n-CPAP for respiratory distress, but without the need of additional oxygen were included in the study. Every patient had a first echocardiography with n-CPAP and then n-CPAP was retrieved. 3 hours later the echocardiography was repeated by the same investigator and then the patient replaced on n-CPAP. Results: 14 premature newborn were included, mean gestational age of 28 _ 2 weeks, mean weight 1.1 _ 0.3 Kg and height 39 _ 3 cm. Echocardiographic measurements are depicted in Table 1. Significant finding were observed between measurement on n- CPAP or without n-CPAP: on end diastolic left ventricular diameter (12.8 _ 1.6 mm vs. 13.5 _ 2 mm), on end systolic left ventricular diameter (8.4 _ 1.3 mm vs. 9.1 _ 1.5 mm), left atrium diameter (8.9 _ 2.2 mm vs. 10.4 _ 2.5 mm), maximal velocity on tricuspid valve (46 _ 10 cm/s vs. 51 _ 9 cm/s), calculated Qp (3.7 _ 0.8 L/min/m2 vs. 4.3 _ 0.8 L/min/m2). Only three patients have demonstrated a PDA during the study. Conclusion: Positive end expiratory pressure (Peep) has hemodynamic effects which are: reduction of systemic and pulmonary venous return as shown by the changes on tricuspid valve inflow,on the calculated Qp and finally on the diameter of the left atrium and left ventricle.We found in premature infants the same hemodynamic effects than those described in adults but with lower Peep values. This could be due to the particular elasticity and weakness of the thoracic wall of premature infants. Interestingly the flow through a PDA seems also to be diminished with Peep, but the number of patients is insufficient to conclude. Further investigation will be needed to better understand these interactions. Table 1. Echocardiographic measurement (mean (SD)). With n-CPAP Without n-CPAP p value RV ED diameter (mm) 6.3 (1.7) 6.04 (1.1) NS LV ED diameter (mm) 12.8 (1.6) 13.5 (2.0) _0.05 LV ES diameter (mm) 8.4 (1.3) 9.1 (1.5) _0.05 SF (%) 34 (5) 33 (6) NS Ao valve diameter (mm) 7.4 (1.3) 7.4 (1.2) NS LA diameter (mm) 8.9 (2.2) 10.4 (2.5) _0.05 Vmax Ao (cm/s) 70 (16) 71 (18) NS Vmax PV (cm/s) 69 (15) 72 (16) NS Vmax TV (cm/s) 46 (10) 51 (9) _0.05 Vmax MV (cm/s) 53 (17) 54 (18) NS Qp (L/min/m2) 3.7 (0.8) 4.3 (0.8) _0.05 Qs (L/min/m2) 4.0 (0.8) 4.0 (0.7) NS Qp/Qs 0.92 (0.14) 1.09 (0.23) _0.05 RV: right ventricle, LV: left ventricle, ED: end diastolic, ES: end systolic, SF: shortening fraction,Ao: aortic valve, LA: left atrium,Vmax: maximum Doppler Velocity, Qp: pulmonary output, Qs: systemic output, NS: non significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: We assessed end-diastolic right ventricular (RV) dimensions and left ventricular (LV) ejection fraction by use of intraoperative transesophageal echocardiography before and after surgical correction of pectus excavatum in adults. METHODS: A prospective study was conducted including 17 patients undergoing surgical correction of pectus excavatum according to the technique of Ravitch-Shamberger between 1999 and 2004. Intraoperative transesophageal echocardiography was performed under general anesthesia before and after surgery to assess end-diastolic RV dimensions and LV ejection fraction. The end-diastolic RV diameter and area were measured in four-chamber and RV inflow-outflow view, and the RV volume was calculated from these data. The LV was assessed by transgastric short-axis view, and its ejection fraction was calculated by use of the Teichholz formula. RESULTS: The end-diastolic RV diameter, area, and volume all significantly increased after surgery (mean values +/- SD, respectively: 2.4 +/- 0.8 cm versus 3.0 +/- 0.9 cm, p < 0.001; 12.5 +/- 5.2 cm(2) versus 18.4 +/- 7.5 cm(2), p < 0.001; and 21.7 +/- 11.7 mL versus 40.8 +/- 23 mL, p < 0.001). The LV ejection fraction also significantly increased after surgery (58.4% +/- 15% versus 66.2% +/- 6%, p < 0.001). CONCLUSIONS: Surgical correction of pectus excavatum according to Ravitch-Shamberger technique results in a significant increase in end-diastolic RV dimensions and a significantly increased LV ejection fraction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. We assessed end-diastolic right ventricular (RV) dimensions and left ventricular (LV) ejection fraction by use of intraoperative transesophageal echocardiography before and after surgical correction of pectus excavatum in adults. Methods. A prospective study was conducted including 17 patients undergoing surgical correction of pectus excavatum according to the technique of Ravitch-Shamberger between 1999 and 2004. Intraoperative transesophageal echocardiography was performed under general anesthesia before and after surgery to assess end-diastolic RV dimensions and LV ejection fraction. The end-diastolic RV diameter and area were measured in four-chamber and RV inflow-outflow view, and the RV volume was calculated from these data. The LV was assessed by transgastric short-axis view, and its ejection fraction was calculated by use of the Teichholz formula. Results. The end-diastolic RV diameter, area, and volume all significantly increased after surgery (mean values +/- SD, respectively: 2.4 +/- 0.8 cm versus 3.0 +/- 0.9 cm, p < 0.001; 12.5 +/- 5.2 cm(2) versus 18.4 +/- 7.5 cm(2), p < 0.001; and 21.7 +/- 11.7 mL versus 40.8 +/- 23 mL, p < 0.001). The LV ejection fraction also significantly increased after surgery (58.4% +/- 15% versus 66.2% +/- 6%, p < 0.001). Conclusions. Surgical correction of pectus excavatum according to Ravitch-Shamberger technique results in a significant increase in end-diastolic RV dimensions and a significantly increased LV ejection fraction. (Ann Thorac Surg 2010; 89: 240-4) (C) 2010 by The Society of Thoracic Surgeons