10 resultados para Totally asymmetric simple exclusion process
em Université de Lausanne, Switzerland
Resumo:
Over the last few decades, the Swiss higher education system has faced important reforms - both concerning its structure and its governance. As with other European countries, one of the most important changes consists of the strengthening of the higher education institutions' research mission through the reinforcement of the role of the National Science Foundation (NSF), which has become increasingly involved in sustaining academic careers. Meanwhile, traditionally and historically, the definition of a faculty member and his or her financial support has come from the higher education institutions (HEI) themselves. This redefinition of power relationships around the funding of academic temporary positions and research activities by the NSF can be analyzed as an attempt to reform the structure of academic careers and the allocation modes of academic positions. Being able to analyze the issue of allocating academic positions within the normative structure of science (Merton, The sociology of science. University of Chicago Press, Chicago, 1973) is a constant concern for those involved in Higher Education Studies. This chapter is an attempt to nurture the debate by questioning, though a quantitative and qualitative research, the tension between the uses of universalist and particularist criteria in the allocation of academic positions. It analyses the possible exclusion process as a consequence of the organization of academic markets and their embeddedness in a wider societal organization.
Resumo:
BACKGROUND: Multiple interventions were made to optimize the medication process in our intensive care unit (ICU). 1 Transcriptions from the medical order form to the administration plan were eliminated by merging both into a single document; 2 the new form was built in a logical sequence and was highly structured to promote completeness and standardization of information; 3 frequently used drug names, approved units, and fixed routes were pre-printed; 4 physicians and nurses were trained with regard to the correct use of the new form. This study was aimed at evaluating the impact of these interventions on clinically significant types of medication errors. METHODS: Eight types of medication errors were measured by a prospective chart review before and after the interventions in the ICU of a public tertiary care hospital. We used an interrupted time-series design to control the secular trends. RESULTS: Over 85 days, 9298 lines of drug prescription and/or administration to 294 patients, corresponding to 754 patient-days were collected and analysed for the three series before and three series following the intervention. Global error rate decreased from 4.95 to 2.14% (-56.8%, P < 0.001). CONCLUSIONS: The safety of the medication process in our ICU was improved by simple and inexpensive interventions. In addition to the optimization of the prescription writing process, the documentation of intravenous preparation, and the scheduling of administration, the elimination of the transcription in combination with the training of users contributed to reducing errors and carried an interesting potential to increase safety.
Resumo:
Cryo-electron microscopy of vitreous sections (CEMOVIS) has recently been shown to provide images of biological specimens with unprecedented quality and resolution. Cutting the sections remains however the major difficulty. Here, we examine the parameters influencing the quality of the sections and analyse the resulting artefacts. They are in particular: knife marks, compression, crevasses, and chatter. We propose a model taking into account the interplay between viscous flow and fracture. We confirm that crevasses are formed on only one side of the section, and define conditions by which they can be avoided. Chatter is an effect of irregular compression due to friction of the section of the knife edge and conditions to prevent this are also explored. In absence of crevasses and chatter, the bulk of the section is compressed approximately homogeneously. Within this approximation, it is possible to correct for compression by a simple linear transformation for the bulk of the section. A research program is proposed to test and refine our understanding of the sectioning process.
Resumo:
This paper investigates a simple procedure to estimate robustly the mean of an asymmetric distribution. The procedure removes the observations which are larger or smaller than certain limits and takes the arithmetic mean of the remaining observations, the limits being determined with the help of a parametric model, e.g., the Gamma, the Weibull or the Lognormal distribution. The breakdown point, the influence function, the (asymptotic) variance, and the contamination bias of this estimator are explored and compared numerically with those of competing estimates.
Resumo:
Presented is an accurate swimming velocity estimation method using an inertial measurement unit (IMU) by employing a simple biomechanical constraint of motion along with Gaussian process regression to deal with sensor inherent errors. Experimental validation shows a velocity RMS error of 9.0 cm/s and high linear correlation when compared with a commercial tethered reference system. The results confirm the practicality of the presented method to estimate swimming velocity using a single low-cost, body-worn IMU.
Resumo:
We characterize the value function of maximizing the total discounted utility of dividend payments for a compound Poisson insurance risk model when strictly positive transaction costs are included, leading to an impulse control problem. We illustrate that well known simple strategies can be optimal in the case of exponential claim amounts. Finally we develop a numerical procedure to deal with general claim amount distributions.
Resumo:
Many research projects in life sciences require purified biologically active recombinant protein. In addition, different formats of a given protein may be needed at different steps of experimental studies. Thus, the number of protein variants to be expressed and purified in short periods of time can expand very quickly. We have therefore developed a rapid and flexible expression system based on described episomal vector replication to generate semi-stable cell pools that secrete recombinant proteins. We cultured these pools in serum-containing medium to avoid time-consuming adaptation of cells to serum-free conditions, maintain cell viability and reuse the cultures for multiple rounds of protein production. As such, an efficient single step affinity process to purify recombinant proteins from serum-containing medium was optimized. Furthermore, a series of multi-cistronic vectors were designed to enable simultaneous expression of proteins and their biotinylation in vivo as well as fast selection of protein-expressing cell pools. Combining these improved procedures and innovative steps, exemplified with seven cytokines and cytokine receptors, we were able to produce biologically active recombinant endotoxin free protein at the milligram scale in 4-6weeks from molecular cloning to protein purification.
Resumo:
It is well established that cancer cells can recruit CD11b(+) myeloid cells to promote tumor angiogenesis and tumor growth. Increasing interest has emerged on the identification of subpopulations of tumor-infiltrating CD11b(+) myeloid cells using flow cytometry techniques. In the literature, however, discrepancies exist on the phenotype of these cells (Coffelt et al., Am J Pathol 2010;176:1564-1576). Since flow cytometry analysis requires particular precautions for accurate sample preparation and trustable data acquisition, analysis, and interpretation, some discrepancies might be due to technical reasons rather than biological grounds. We used the syngenic orthotopic 4T1 mammary tumor model in immunocompetent BALB/c mice to analyze and compare the phenotype of CD11b(+) myeloid cells isolated from peripheral blood and from tumors, using six-color flow cytometry. We report here that the nonspecific antibody binding through Fc receptors, the presence of dead cells and cell doublets in tumor-derived samples concur to generate artifacts in the phenotype of tumor-infiltrating CD11b(+) subpopulations. We show that the heterogeneity of tumor-infiltrating CD11b(+) subpopulations analyzed without particular precautions was greatly reduced upon Fc block treatment, dead cells, and cell doublets exclusion. Phenotyping of tumor-infiltrating CD11b(+) cells was particularly sensitive to these parameters compared to circulating CD11b(+) cells. Taken together, our results identify Fc block treatment, dead cells, and cell doublets exclusion as simple but crucial steps for the proper analysis of tumor-infiltrating CD11b(+) cell populations.
Resumo:
A highly sensitive ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method was developed for the quantification of buprenorphine and its major metabolite norbuprenorphine in human plasma. In order to speed up the process and decrease costs, sample preparation was performed by simple protein precipitation with acetonitrile. To the best of our knowledge, this is the first application of this extraction technique for the quantification of buprenorphine in plasma. Matrix effects were strongly reduced and selectivity increased by using an efficient chromatographic separation on a sub-2μm column (Acquity UPLC BEH C18 1.7μm, 2.1×50mm) in 5min with a gradient of ammonium formate 20mM pH 3.05 and acetonitrile as mobile phase at a flow rate of 0.4ml/min. Detection was made using a tandem quadrupole mass spectrometer operating in positive electrospray ionization mode, using multiple reaction monitoring. The procedure was fully validated according to the latest Food and Drug Administration guidelines and the Société Française des Sciences et Techniques Pharmaceutiques. Very good results were obtained by using a stable isotope-labeled internal standard for each analyte, to compensate for the variability due to the extraction and ionization steps. The method was very sensitive with lower limits of quantification of 0.1ng/ml for buprenorphine and 0.25ng/ml for norbuprenorphine. The upper limit of quantification was 250ng/ml for both drugs. Trueness (98.4-113.7%), repeatability (1.9-7.7%), intermediate precision (2.6-7.9%) and internal standard-normalized matrix effects (94-101%) were in accordance with international recommendations. The procedure was successfully used to quantify plasma samples from patients included in a clinical pharmacogenetic study and can be transferred for routine therapeutic drug monitoring in clinical laboratories without further development.
Resumo:
PURPOSE: (1) To assess the outcomes of minimally invasive simple prostatectomy (MISP) for the treatment of symptomatic benign prostatic hyperplasia in men with large prostates and (2) to compare them with open simple prostatectomy (OSP). METHODS: A systematic review of outcomes of MISP for benign prostatic hyperplasia with meta-analysis was conducted. The article selection process was conducted according to the PRISMA guidelines. RESULTS: Twenty-seven observational studies with 764 patients were analyzed. The mean prostate volume was 113.5 ml (95 % CI 106-121). The mean increase in Qmax was 14.3 ml/s (95 % CI 13.1-15.6), and the mean improvement in IPSS was 17.2 (95 % CI 15.2-19.2). Mean duration of operation was 141 min (95 % CI 124-159), and the mean intraoperative blood loss was 284 ml (95 % CI 243-325). One hundred and four patients (13.6 %) developed a surgical complication. In comparative studies, length of hospital stay (WMD -1.6 days, p = 0.02), length of catheter use (WMD -1.3 days, p = 0.04) and estimated blood loss (WMD -187 ml, p = 0.015) were significantly lower in the MISP group, while the duration of operation was longer than in OSP (WMD 37.8 min, p < 0.0001). There were no differences in improvements in Qmax, IPSS and perioperative complications between both procedures. The small study sizes, publication bias, lack of systematic complication reporting and short follow-up are limitations. CONCLUSIONS: MISP seems an effective and safe treatment option. It provides similar improvements in Qmax and IPSS as OSP. Despite taking longer, it results in less blood loss and shorter hospital stay. Prospective randomized studies comparing OSP, MISP and laser enucleation are needed to define the standard surgical treatment for large prostates.