168 resultados para Total hip arthroplasty revision surgery · tabular reconstruction · Bone loss · Ceramics

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Management of bone loss in revision total hip replacement remains a challenge. To eliminate any immunological or infectious problem and so to try to improve the long-term results obtained with allografts, the authors used synthetic ceramics as bone substitutes since 1995. We reviewed 13 of the patients of our study, we previously reported in 2005 (Schwartz and Bordei in Eur J Orthop Surg Traumatol 15: 191 2005), which was a pro- spective cohort of thirty-two cases of acetabular revision reconstruction, with a mean follow-up of 14.4 years yet (from 9 to 16 years). Clinical results were assessed according to Oxford scale and Postel and Merle d'Aubigne (PMA) scale. Since 2005, no specific complications were noted. The average PMA functional hip score was 14.9 (vs. 9.2 before revision) at follow-up over 9 years. Nine patients still alive in 2013 were seen again by a surgeon, which was not the operator, with a mean follow-up of 15.3 years: Their Oxford average score was 40.3. Radio- logical assessment affirmed a good integration of the sub- stitutes in bone without any edging in all cases. A progressive invasion of the ceramics by bone can be seen on the X-ray. We conclude that about 15 years of average delay, which is a significant follow-up in orthopedic sur- gery, the outcomes without specific complications are satisfactory and allow one to go with these materials in total hip revision surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reconstruction of important parameters such as femoral offset and torsion is inaccurate, when templating is based on plain x-rays. We evaluate intraoperative reproducibility of pre-operative CT-based 3D-templating in a consecutive series of 50 patients undergoing primary cementless THA through an anterior approach. Pre-operative planning was compared to a postoperative CT scan by image fusion. The implant size was correctly predicted in 100% of the stems, 94% of the cups and 88% of the heads (length). The difference between the planned and the postoperative leg length was 0.3 + 2.3 mm. Values for overall offset, femoral anteversion, cup inclination and anteversion were 1.4 mm ± 3.1, 0.6° ± 3.3°, -0.4° ± 5° and 6.9° ± 11.4°, respectively. This planning allows accurate implant size prediction. Stem position and cup inclination are accurately reproducible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe the use of cable fixation and acute total hip replacement for acetabular fracture in the elderly. 12 patients with acetabular fractures, having a mean age of 79 (65-93) years, were treated with cable fixation and acute total hip arthroplasty. 8 were T-shaped fractures and 4 associated fractures of the posterior column and posterior wall. 1 patient died 5 months after surgery and the remaining 11 were followed for 2 years. All patients had a good clinical outcome. Radiographic assessment showed healing of the fracture and a satisfactory alignment of the cup without loosening. This surgical technique provides good primary fixation, stabilizes complex acetabular fractures in elderly patients with osteoporotic bone and permits early postoperative mobilization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Medialization of the cup with a respective increase in femoral offset has been proposed in THA to increase abductor moment arms. Insofar as there are potential disadvantages to cup medialization, it is important to ascertain whether the purported biomechanical benefits of cup medialization are large enough to warrant the downsides; to date, studies regarding this question have disagreed. QUESTIONS/PURPOSES: The purpose of this study was to quantify the effect of cup medialization with a compensatory increase in femoral offset compared with anatomic reconstruction for patients undergoing THA. We tested the hypothesis that there is a (linear) correlation between preoperative anatomic parameters and muscle moment arm increase caused by cup medialization. METHODS: Fifteen patients undergoing THA were selected, covering a typical range of preoperative femoral offsets. For each patient, a finite element model was built based on a preoperative CT scan. The model included the pelvis, femur, gluteus minimus, medius, and maximus. Two reconstructions were compared: (1) anatomic position of the acetabular center of rotation, and (2) cup medialization compensated by an increase in the femoral offset. Passive abduction-adduction and flexion-extension were simulated in the range of normal gait. Muscle moment arms were evaluated and correlated to preoperative femoral offset, acetabular offset, height of the greater trochanter (relative to femoral center of rotation), and femoral antetorsion angle. RESULTS: The increase of muscle moment arms caused by cup medialization varied among patients. Muscle moment arms increase by 10% to 85% of the amount of cup medialization for abduction-adduction and from -35% (decrease) to 50% for flexion-extension. The change in moment arm was inversely correlated (R(2) = 0.588, p = 0.001) to femoral antetorsion (anteversion), such that patients with less femoral antetorsion gained more in terms of hip muscle moments. No linear correlation was observed between changes in moment arm and other preoperative parameters in this series. CONCLUSIONS: The benefit of cup medialization is variable and depends on the individual anatomy. CLINICAL RELEVANCE: Cup medialization with compensatory increase of the femoral offset may be particularly effective in patients with less femoral antetorsion. However, cup medialization must be balanced against its tradeoffs, including the additional loss of medial acetabular bone stock, and eventual proprioceptive implications of the nonanatomic center of rotation and perhaps joint reaction forces. Clinical studies should better determine the relevance of small changes of moment arms on function and joint reaction forces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La planification scanographique (3D) a démontré son utilité pour une reconstruction anatomique plus précise de la hanche (longueur du fémur, centre de rotation, offset, antéversion et rétroversion). Des études ont montré que lors de la planification 2D 50% seulement correspondaient à l'implant définitif du fémur alors que dans une autre étude ce taux s'élevait à 94% pour une planification 3D. Les erreurs étaient liées à l'agrandissement des radiographies. L'erreur sur la taille de la tige est liée à l'estimation inadéquate de la morphologie osseuse ainsi qu'à la densité osseuse. L'erreur de l'antéversion, augmentée par l'inclinaison du bassin, a pu être éliminée par la planification 3D et l'offset restauré dans 98%. Cette étude est basée sur une nouvelle technique de planification scanographique en trois dimensions pour une meilleure précision de la reconstruction de la hanche. Le but de cette étude est de comparer l'anatomie post-opératoire à celle préopératoire en comparant les tailles d'implant prévu lors de la planification 3D à celle réellement utilisée lors de l'opération afin de déterminer l'exactitude de la restauration anatomique avec étude des différents paramètres (centre de rotation, densité osseuse, L'offset fémoral, rotations des implants, longueur du membre) à l'aide du Logiciel HIP-PLAN (Symbios) avec évaluation de la reproductibilité de notre planification 3D dans une série prospective de 50 patients subissant une prothèse totale de hanche non cimentée primaire par voie antérieure. La planification pré-opératoire a été comparée à un CTscan postopératoire par fusion d'images. CONCLUSION ET PRESPECTIVE Les résultats obtenus sont les suivants : La taille de l'implant a été prédit correctement dans 100% des tiges, 94% des cupules et 88% des têtes (longueur). La différence entre le prévu et la longueur de la jambe postopératoire était de 0,3+2,3 mm. Les valeurs de décalage global, antéversion fémorale, inclinaison et antéversion de la cupule étaient 1,4 mm ± 3,1, 0,6 ± 3,3 0 -0,4 0 ± 5 et 6,9 ° ± 11,4, respectivement. Cette planification permet de prévoir la taille de l'implant précis. Position de la tige et de l'inclinaison de la cupule sont exactement reproductible. La planification scanographique préopératoire 3D permet une évaluation précise de l'anatomie individuelle des patients subissant une prothèse totale de hanche. La prédiction de la taille de l'implant est fiable et la précision du positionnement de la tige est excellente. Toutefois, aucun avantage n'est observée en termes d'orientation de la cupule par rapport aux études impliquant une planification 2D ou la navigation. De plus amples recherches comparant les différentes techniques de planification pré-opératoire à la navigation sont nécessaire.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eighteen patients with acetabular fractures, with a mean age of 76 years, were treated with cable fixation and acute total hip arthroplasty. Nine were T-shaped fractures, 4 associated transverse and posterior wall, 2 transverse, 2 posterior column and posterior wall, and 1 anterior and posterior hemitransverse fractures. One patient experienced 3 episodes of hip dislocation within 10 months after surgery. All the others had a good outcome at a mean follow-up time of 36 months. Radiographic assessment showed healing of the fracture and a satisfactory alignment of the cup without loosening. This option provides good primary fixation, stabilizes complex acetabular fractures in elderly patients, and permits early postoperative mobilization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Complications related to the neck-stem junction of modular stems used for total hip arthroplasty (THA) are generating increasing concern. A 74-year-old male had increasing pain and a cutaneous reaction around the scar 1 year after THA with a modular neck-stem. Imaging revealed osteolysis of the calcar and a pseudo-tumour adjacent to the neck-stem junction. Serum cobalt levels were elevated. Revision surgery to exchange the stem and liner and to resect the pseudo-tumour was performed. Analysis of the stem by scanning electron microscopy and by energy dispersive X-ray and white light interferometry showed fretting corrosion at the neck-stem junction contrasting with minimal changes at the head-neck junction. Thus, despite dry assembly of the neck and stem on the back table at primary THA, full neck-stem contact was not achieved, and the resulting micromotion at the interface led to fretting corrosion. This case highlights the mechanism of fretting corrosion at the neck-stem interface responsible for adverse local tissue reactions. Clinical and radiological follow-up is mandatory in patients with dual-modular stems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Malposition of the acetabular component during hip arthroplasty increases the occurrence of impingement, reduces range of motion, and increases the risk of dislocation and long-term wear. To prevent malpositioned hip implants, an increasing number of computer-assisted orthopaedic systems have been described, but their accuracy is not well established. The purpose of this study was to determine the reproducibility and accuracy of conventional versus computer-assisted techniques for positioning the acetabular component in total hip arthroplasty. Using a lateral approach, 150 cups were placed by 10 surgeons in 10 identical plastic pelvis models (freehand, with a mechanical guide, using computer assistance). Conditions for cup implantations were made to mimic the operating room situation. Preoperative planning was done from a computed tomography scan. The accuracy of cup abduction and anteversion was assessed with an electromagnetic system. Freehand placement revealed a mean accuracy of cup anteversion and abduction of 10 degrees and 3.5 degrees, respectively (maximum error, 35 degrees). With the cup positioner, these angles measured 8 degrees and 4 degrees (maximum error, 29.8 degrees), respectively, and using computer assistance, 1.5 degrees and 2.5 degrees degrees (maximum error, 8 degrees), respectively. Computer-assisted cup placement was an accurate and reproducible technique for total hip arthroplasty. It was more accurate than traditional methods of cup positioning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This prospective study addresses early results of the treatment of acute acetabular fractures in elderly patients by total hip arthroplasty and cerclage wiring.Fifteen patients with an average age of 81 years were treated at our institution between February 1998 and December 2000. There were two transverse fractures, eight T-shaped fractures, two transverse fractures with associated posterior wall fracture, two posterior column fractures with associated posterior wall fracture, and one fracture of both columns. Treatment consisted of cerclage wiring of the fracture and primary non-cemented total hip replacement.All of the patients were followed for a mean of 36 months. Although there was one patient with three hip dislocations during the first 10 months after the operation, we found an excellent or good result for the entire group. During this relatively short follow-up period, we have not found a radiological loss of fracture reduction of more than 1 mm or a cup migration of more than 3.2 mm. All of the fractures healed and no loosening of the implant was evident.Primary total hip arthroplasty combined with internal fixation is a valid treatment option for acetabular fractures in the elderly. Preliminary results are convincing, but a bigger patient population and a longer follow-up time are necessary before we are able to draw final conclusions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a prospective study, total hip arthroplasty (THA) patients were assessed preoperatively and postoperatively (n = 95) to determine if tender points (TPs) are associated with poor THA outcomes. Patients with high follow-up TP counts had higher visual analog scale (VAS) for pain and sleep, higher follow-up Western Ontario and McMaster Universities Arthritis Index (pain, stiffness, function), lower Health Assessment Questionnaire, Harris Hip, and Short Form 36 (physical functioning, bodily pain, physical component summary) scores. High follow-up TP were associated with increased pain, pain not relieved by surgery, poor function, and poor sleep. Visual analog scale pain and sleep, Short Form 36 (physical functioning, bodily pain), Western Ontario and McMaster Universities Arthritis Index, Health Assessment Questionnaire, and Harris hip scores improved significantly after THA; TP scores did not. Higher preoperative TP were predictive of higher follow-up TP but were poorly predictive of poor outcome measures after surgery in individual patients, suggesting that preoperative TPs are contraindicative for THA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Total hip replacement has seen a tremendous development and has become one of the most successful surgical interventions in orthopaedics. While during the first decades of development of total hip arthroplasty the fixation of the implant into the bone was the main concern, the focus has shifted towards surgical technique and soft tissue handling. In order to avoid permanent soft tissue damage, muscular dysfunction and concerns in regards to cosmetics, minimal invasive and anatomic approaches have been developed. We here provide a short overview on various methods of total hip replacements and we describe our technique through a minimal invasive direct anterior approach. While muscle and nerve damage is minimal, this technique allows for a rapid rehabilitation and is associated with an excellent functional outcome and a minimal risk for dislocation.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low-molecular-weight heparins have become the predominant choice for deep venous thrombosis prophylaxis and treatment. However, their use may cause bleeding complications. Intrahepatic bleeding is exceptional and only very few cases have been described. The authors present a unique case of fatal intrahepatic hematoma complicating nadroparin use in a 65-year-old woman with a hepatic cyst who was admitted to hospital for unilateral total hip arthroplasty. At autopsy, hemoperitoneum (2,000 ml of blood and clots) was evident. A ruptured sub-capsular hematoma involving the right lobe of the liver was observed. The hemorrhage within the cyst induced by the nadroparin use was likely responsible for the subsequent hepatic hematoma, liver rupture, and death. This case highlights the need for pathologists and surgeons to be aware of the possibility of intrahepatic hematoma in patients who have received low-molecular-weight heparins, undergone major surgery and present postoperative hemodynamic instability, especially in those with preoperative diagnosis of hepatic cyst.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We conducted this study to determine the relative influence of various mechanical and patient-related factors on the incidence of dislocation after primary total hip asthroplasty (THA). Of 2,023 THAs, 21 patients who had at least 1 dislocation were compared with a control group of 21 patients without dislocation, matched for age, gender, pathology, and year of surgery. Implant positioning, seniority of the surgeon, American Society of Anesthesiologists (ASA) score, and diminished motor coordination were recorded. Data analysis included univariate and multivariate methods. The dislocation risk was 6.9 times higher if total anteversion was not between 40 degrees and 60 degrees and 10 times higher in patients with high ASA scores. Surgeons should pay attention to total anteversion (cup and stem) of THA. The ASA score should be part of the preoperative assessment of the dislocation risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Although the importance of accurate femoral reconstruction to achieve a good functional outcome is well documented, quantitative data on the effects of a displacement of the femoral center of rotation on moment arms are scarce. The purpose of this study was to calculate moment arms after nonanatomical femoral reconstruction. METHODS: Finite element models of 15 patients including the pelvis, the femur, and the gluteal muscles were developed. Moment arms were calculated within the native anatomy and compared to distinct displacement of the femoral center of rotation (leg lengthening of 10 mm, loss of femoral offset of 20%, anteversion ±10°, and fixed anteversion at 15°). Calculations were performed within the range of motion observed during a normal gait cycle. RESULTS: Although with all evaluated displacements of the femoral center of rotation, the abductor moment arm remained positive, some fibers initially contributing to extension became antagonists (flexors) and vice versa. A loss of 20% of femoral offset led to an average decrease of 15% of abductor moment. Femoral lengthening and changes in femoral anteversion (±10°, fixed at 15°) led to minimal changes in abductor moment arms (maximum change of 5%). Native femoral anteversion correlated with the changes in moment arms induced by the 5 variations of reconstruction. CONCLUSION: Accurate reconstruction of offset is important to maintaining abductor moment arms, while changes of femoral rotation had minimal effects. Patients with larger native femoral anteversion appear to be more susceptible to femoral head displacements.