INTRODUCTION AND HYPOTHESIS: The objective of this study is to assess anatomical and functional results of the extraperitoneal uterosacral ligament suspension (USL) in women with post-hysterectomy vaginal vault prolapse. METHODS: One hundred and twenty-three consecutive women were included. Concurrent procedures were anterior colporraphy with fascial repair (20%) and mesh reinforcement (49%), posterior colporraphy with fascial repair (38%) and mesh reinforcement (56%) and a sling procedure (29%). Women were assessed using Baden and Walker and pelvic organ prolapse quantification classification pre- and post-operatively. RESULTS: One hundred and ten patients (89%) were available for follow-up. Mean follow-up was 2 years. Objective success rate regarding the vaginal cuff is 95.4%. Global anatomical success rate was 85.5%. Urinary, coital and bowel symptoms were improved following surgery. Mesh exposure rate was 19.3%, with all cases managed conservatively or with minor interventions. CONCLUSION: Bilateral extraperitoneal USL is an effective operation to restore apical support with low morbidity, which avoids potential risks associated with opening the peritoneal cavity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE To assess the specific risks of injury to neural and vascular structures inherent in two approaches to transobturator surgery for inserting a suburethral sling, i.e. the outside-in (standard technique) and inside-out approaches. MATERIALS AND METHODS The study comprised seven cadavers, providing 14 obturator regions. Five specimens had a tape inserted outside-in on one side, and inside-out on the other; of the remaining two cadavers, one had an inside-out tape and one an outside-in tape, bilaterally. After tape insertion, the cadavers were dissected. Particular attention was paid to the distances between the tape and the deep external pudendal vessels, and between the tape and the posterior branch of the obturator nerve. RESULTS With the inside-out technique, the safety margins were reduced, and the external pudendal vessels and the posterior branch of the obturator nerve were at greater risk of injury. CONCLUSION The two techniques are not equivalent, with a lower risk of injury to vascular and nerve structures with the outside-in technique.