6 resultados para Steel corrosion
em Université de Lausanne, Switzerland
Resumo:
Achievement careers are regarded as a distinctive element of the post-war period in occidental societies. Such a career was at once a modal trajectory of the modern parts of middleclass men and a social emblem for progress and success. However, if the achievement career came to be a biographical pattern with great normative power, its precise sequential course remained vague. Theories of the 1960s and 1970s described it as an orderly advancement within large firms. By the 1990s, scholars postulated an erosion of the organizational structures that once contributed to the institutionalization of careers, accompanied by a weakening of the normative weight of the achievement career by management discourse. We question the thesis of the corrosion of achievement career by analysing the trajectories of 442 engineers and business economists in Switzerland in regard to their orderliness, loyalty, and temporal rhythm. An inspection of types of careers and cohorts reveals that even if we face a decline of loyalty over time, hierarchical orderliness is not touched by those changes. Foremost, technical-industrial careers fit the loyal and regular pattern. Hence, this trajectory-type represents only a minority and is by far the slowest and least successful in terms of hierarchical ascension.
Resumo:
Validated in vitro methods for skin corrosion and irritation were adopted by the OECD and by the European Union during the last decade. In the EU, Switzerland and countries adopting the EU legislation, these assays may allow the full replacement of animal testing for identifying and classifying compounds as skin corrosives, skin irritants, and non irritants. In order to develop harmonised recommendations on the use of in vitro data for regulatory assessment purposes within the European framework, a workshop was organized by the Swiss Federal Office of Public Health together with ECVAM and the BfR. It comprised stakeholders from various European countries involved in the process from in vitro testing to the regulatory assessment of in vitro data. Discussions addressed the following questions: (1) the information requirements considered useful for regulatory assessment; (2) the applicability of in vitro skin corrosion data to assign the corrosive subcategories as implemented by the EU Classification, Labelling and Packaging Regulation; (3) the applicability of testing strategies for determining skin corrosion and irritation hazards; and (4) the applicability of the adopted in vitro assays to test mixtures, preparations and dilutions. Overall, a number of agreements and recommendations were achieved in order to clarify and facilitate the assessment and use of in vitro data from regulatory accepted methods, and ultimately help regulators and scientists facing with the new in vitro approaches to evaluate skin irritation and corrosion hazards and risks without animal data.
Resumo:
This doctoral thesis deals with the rise and potential fall of achievement career as an institutional biographical pattern. I start with the assumption that the achievement career, as a result of the spread of large-scale bureaucratic companies, the male-breadwinner family model, and meritocratic ideals, came to life in the first half of the twentieth century. During the so-called 30 glorieuses, it became even a normatively dominant and also politically significant male biographical pattern. But the structural changes that announced the end of the post-war golden age seemed also to threaten and-according to certain scholars-erode this type of occupational trajectory. In order to understand this dynamic I will try to reconstruct the achievement career in Switzerland empirically. I examine (1) the structural changes of the economic field from 1970 to 2000, (2) the transformations of the trajectories during this period, and (3) ways in which the concerned individuals interpret and react to these changes.
Resumo:
Complications related to the neck-stem junction of modular stems used for total hip arthroplasty (THA) are generating increasing concern. A 74-year-old male had increasing pain and a cutaneous reaction around the scar 1 year after THA with a modular neck-stem. Imaging revealed osteolysis of the calcar and a pseudo-tumour adjacent to the neck-stem junction. Serum cobalt levels were elevated. Revision surgery to exchange the stem and liner and to resect the pseudo-tumour was performed. Analysis of the stem by scanning electron microscopy and by energy dispersive X-ray and white light interferometry showed fretting corrosion at the neck-stem junction contrasting with minimal changes at the head-neck junction. Thus, despite dry assembly of the neck and stem on the back table at primary THA, full neck-stem contact was not achieved, and the resulting micromotion at the interface led to fretting corrosion. This case highlights the mechanism of fretting corrosion at the neck-stem interface responsible for adverse local tissue reactions. Clinical and radiological follow-up is mandatory in patients with dual-modular stems.
Resumo:
The present study was initiated with the aim to assess the in vivo electrochemical corrosion behaviour of CoCrMo biomedical alloys in human synovial fluids in an attempt to identify possible patient or pathology specific effects. For this, electrochemical measurements (open circuit potential OCP, polarization resistance Rp, potentiodynamic polarization curves, electrochemical impedance spectroscopy EIS) were carried out on fluids extracted from patients with different articular pathologies and prosthesis revisions. Those electrochemical measurements could be carried out with outstanding precision and signal stability. The results show that the corrosion behaviour of CoCrMo alloy in synovial fluids not only depends on material reactivity but also on the specific reactions of synovial fluid components, most likely involving reactive oxygen species. In some patients the latter were found to determine the whole cathodic and anodic electrochemical response. Depending on patients, corrosion rates varied significantly between 50 and 750mgdm(-2)year(-1).