248 resultados para Standard reference
em Université de Lausanne, Switzerland
Resumo:
Few subjects have caught the attention of the entire world as much as those dealing with natural hazards. The first decade of this new millennium provides a litany of tragic examples of various hazards that turned into disasters affecting millions of individuals around the globe. The human losses (some 225,000 people) associated with the 2004 Indian Ocean earthquake and tsunami, the economic costs (approximately 200 billion USD) of the 2011 Tohoku Japan earthquake, tsunami and reactor event, and the collective social impacts of human tragedies experienced during Hurricane Katrina in 2005 all provide repetitive reminders that we humans are temporary guests occupying a very active and angry planet. Any examples may have been cited here to stress the point that natural events on Earth may, and often do, lead to disasters and catastrophes when humans place themselves into situations of high risk. Few subjects share the true interdisciplinary dependency that characterizes the field of natural hazards. From geology and geophysics to engineering and emergency response to social psychology and economics, the study of natural hazards draws input from an impressive suite of unique and previously independent specializations. Natural hazards provide a common platform to reduce disciplinary boundaries and facilitate a beneficial synergy in the provision of timely and useful information and action on this critical subject matter. As social norms change regarding the concept of acceptable risk and human migration leads to an explosion in the number of megacities, coastal over-crowding and unmanaged habitation in precarious environments such as mountainous slopes, the vulnerability of people and their susceptibility to natural hazards increases dramatically. Coupled with the concerns of changing climates, escalating recovery costs, a growing divergence between more developed and less developed countries, the subject of natural hazards remains on the forefront of issues that affect all people, nations, and environments all the time.This treatise provides a compendium of critical, timely and very detailed information and essential facts regarding the basic attributes of natural hazards and concomitant disasters. The Encyclopedia of Natural Hazards effectively captures and integrates contributions from an international portfolio of almost 300 specialists whose range of expertise addresses over 330 topics pertinent to the field of natural hazards. Disciplinary barriers are overcome in this comprehensive treatment of the subject matter. Clear illustrations and numerous color images enhance the primary aim to communicate and educate. The inclusion of a series of unique ?classic case study? events interspersed throughout the volume provides tangible examples linking concepts, issues, outcomes and solutions. These case studies illustrate different but notable recent, historic and prehistoric events that have shaped the world as we now know it. They provide excellent focal points linking the remaining terms in the volume to the primary field of study. This Encyclopedia of Natural Hazards will remain a standard reference of choice for many years.
Resumo:
Gene therapy approaches using recombinant adeno-associated virus serotype 2 (rAAV2) and serotype 8 (rAAV8) have achieved significant clinical benefits. The generation of rAAV Reference Standard Materials (RSM) is key to providing points of reference for particle titer, vector genome titer, and infectious titer for gene transfer vectors. Following the example of the rAAV2RSM, here we have generated and characterized a novel RSM based on rAAV serotype 8. The rAAV8RSM was produced using transient transfection, and the purification was based on density gradient ultracentrifugation. The rAAV8RSM was distributed for characterization along with standard assay protocols to 16 laboratories worldwide. Mean titers and 95% confidence intervals were determined for capsid particles (mean, 5.50×10(11) pt/ml; CI, 4.26×10(11) to 6.75×10(11) pt/ml), vector genomes (mean, 5.75×10(11) vg/ml; CI, 3.05×10(11) to 1.09×10(12) vg/ml), and infectious units (mean, 1.26×10(9) IU/ml; CI, 6.46×10(8) to 2.51×10(9) IU/ml). Notably, there was a significant degree of variation between institutions for each assay despite the relatively tight correlation of assay results within an institution. This outcome emphasizes the need to use RSMs to calibrate the titers of rAAV vectors in preclinical and clinical studies at a time when the field is maturing rapidly. The rAAV8RSM has been deposited at the American Type Culture Collection (VR-1816) and is available to the scientific community.
Resumo:
Phylogenomic databases provide orthology predictions for species with fully sequenced genomes. Although the goal seems well-defined, the content of these databases differs greatly. Seven ortholog databases (Ensembl Compara, eggNOG, HOGENOM, InParanoid, OMA, OrthoDB, Panther) were compared on the basis of reference trees. For three well-conserved protein families, we observed a generally high specificity of orthology assignments for these databases. We show that differences in the completeness of predicted gene relationships and in the phylogenetic information are, for the great majority, not due to the methods used, but to differences in the underlying database concepts. According to our metrics, none of the databases provides a fully correct and comprehensive protein classification. Our results provide a framework for meaningful and systematic comparisons of phylogenomic databases. In the future, a sustainable set of 'Gold standard' phylogenetic trees could provide a robust method for phylogenomic databases to assess their current quality status, measure changes following new database releases and diagnose improvements subsequent to an upgrade of the analysis procedure.
Resumo:
Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.
Resumo:
Acute myocarditis was until recently one of the most difficult diagnoses in cardiology. The spectrum of signs and symptoms is very wide, the usual non-invasive tests lack specificity and the myocardial biopsy is only performed in a minority of cases to confirm the diagnosis. Due to its unique ability to directly image myocardial necrosis, fibrosis and oedema, cardiac magnetic resonance (CMR) is now considered the primary tool for noninvasive assessment of patients with suspected myocarditis. CMR is also useful for monitoring disease activity under treatment. Myocarditis has been associated with the development of dilated cardiomyopathy; CMR could play a role in the follow-up of such cases to detect the progression toward a dilatative phenotype. Precise mapping of myocardial lesions with cardiac MRI is invaluable to guide myocardial biopsy and increase its diagnostic yield by improving sensitivity.
Resumo:
The aim of this study was to determine potential relationships between anthropometric parameters and athletic performance with special consideration to repeated-sprint ability (RSA). Sixteen players of the senior male Qatar national soccer team performed a series of anthropometric and physical tests including countermovement jumps without (CMJ) and with free arms (CMJwA), straight-line 20 m sprint, RSA (6 × 35 m with 10 s recovery) and incremental field test. Significant (P < 0.05) relationships occurred between muscle-to-bone ratio and both CMJs height (r ranging from 0.56 to 0.69) as well as with all RSA-related variables (r < -0.53 for sprinting times and r = 0.54 for maximal sprinting speed) with the exception of the sprint decrement score (Sdec). The sum of six skinfolds and adipose mass index were largely correlated with Sdec (r = 0.68, P < 0.01 and r = 0.55, P < 0.05, respectively) but not with total time (TT, r = 0.44 and 0.33, P > 0.05, respectively) or any standard athletic tests. Multiple regression analyses indicated that muscular cross-sectional area for mid-thigh, adipose index, straight-line 20 m time, maximal sprinting speed and CMJwA are the strongest predictors of Sdec (r(2) = 0.89) and TT (r(2) = 0.95) during our RSA test. In the Qatar national soccer team, players' power-related qualities and RSA are associated with a high muscular profile and a low adiposity. This supports the relevance of explosive power for the soccer players and the larger importance of neuromuscular qualities determining the RSA.
Resumo:
We evaluated midterm patient-reported outcomes and satisfaction with total hip arthroplasty in patients who had severe juvenile idiopathic arthritis. Thirty-one patients (49 hips), with a mean age of 29 years (range, 16-43 years), reported low hip pain and stiffness at follow-up (mean, 7 years; range, 3-17 years). Up to 92% were satisfied with their ability to perform various activities; 96% were satisfied with pain relief. A mean postoperative flexion arc of 96° was observed. Final 36-Item Short Form Health Survey, EuroQol in 5 dimensions, Western Ontario and McMaster Universities Arthritis Index, and Harris Hip scores were lower than reference populations, particularly for mobility, physical functioning, and social functioning subscores. Young adults with end-stage hip involvement and severe longstanding juvenile idiopathic arthritis expressed high satisfaction with total hip arthroplasty, which improved range of motion, pain, and stiffness, despite poor performance on widely used outcome measures.
Resumo:
Background: Urine is still the matrix of choice to fight against doping, because it can be collected non-invasively during anti-doping tests. Most of the World Anti-Doping Agency's accredited laboratories have more than 20 years experience in analyzing this biological fluid and the majority of the compounds listed in the 2010 Prohibited List - International Standard are eliminated through the urinary apparatus. Storing and transporting urine samples for doping analyses does not include a specific protocol to prevent microbial and thermal degradation. The use of a rapid and reliable screening method could enable determine reference intervals for urine specimens in doping control samples and evaluate notably the prevalence of microbial contamination known to be responsible for the degradation of chemical substances in urine.Methods: The Sysmex(R) UF-500i is a recent urine flow cytometer analyzer capable of quantifying BACT and other urinary particles such as RBC, WBC, EC, DEBRIS, CAST, PATH. CAST, YLC, SRC as well as measuring urine conductivity. To determine urine anti-doping reference intervals, 501 samples received in our laboratory over a period of two months were submitted to an immediate examination. All samples were collected and then transported at room temperature. Analysis of variance was performed to test the effects of factors such as gender, test type [in-competition, out-of-competition] and delivery time.Results: The data obtained showed that most of the urine samples were highly contaminated with bacteria. The other urine particles were also very different according to the factors.Conclusions: The Sysmex(R) UF-500i was capable of providing a snapshot of urine particles present in the samples at the time of the delivery to the laboratory. These particles, BACT in particular, gave a good idea of the possible microbial degradation which had and/or could have occurred in the sample. This information could be used as the first quality control set up in WADA (World Anti-Doping Agency) accredited laboratories to determine if steroid profiles, endogenous and prohibited substances have possibly been altered. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Next-generation sequencing (NGS) technologies have become the standard for data generation in studies of population genomics, as the 1000 Genomes Project (1000G). However, these techniques are known to be problematic when applied to highly polymorphic genomic regions, such as the human leukocyte antigen (HLA) genes. Because accurate genotype calls and allele frequency estimations are crucial to population genomics analyses, it is important to assess the reliability of NGS data. Here, we evaluate the reliability of genotype calls and allele frequency estimates of the single-nucleotide polymorphisms (SNPs) reported by 1000G (phase I) at five HLA genes (HLA-A, -B, -C, -DRB1, and -DQB1). We take advantage of the availability of HLA Sanger sequencing of 930 of the 1092 1000G samples and use this as a gold standard to benchmark the 1000G data. We document that 18.6% of SNP genotype calls in HLA genes are incorrect and that allele frequencies are estimated with an error greater than ±0.1 at approximately 25% of the SNPs in HLA genes. We found a bias toward overestimation of reference allele frequency for the 1000G data, indicating mapping bias is an important cause of error in frequency estimation in this dataset. We provide a list of sites that have poor allele frequency estimates and discuss the outcomes of including those sites in different kinds of analyses. Because the HLA region is the most polymorphic in the human genome, our results provide insights into the challenges of using of NGS data at other genomic regions of high diversity.
Resumo:
Shrews of the genus Crocidura from Sicily revealed a new karyotype from Europe: 2n = 36, NF = 56, NFa = 52. With reference to the revision of Vesmanis (1976), this shrew is provisionally attributed to C. caudata Miller, 1901 and it is proposed to call it the "Sicilian shrew". Its chromosome complement is similar to that of shrews from Canary Islands and a species from Burundi (Central Africa), suggesting that it might have split off from a line of Paleotropical origin. Following these findings, the modern concept of Mediterranean island colonization by shrews must be revised. The distinctive characteristics of Mediterranean shrews should also be revised.
Resumo:
OBJECTIVES: In this population-based study, reference values were generated for renal length, and the heritability and factors associated with kidney length were assessed. METHODS: Anthropometric parameters and renal ultrasound measurements were assessed in randomly selected nuclear families of European ancestry (Switzerland). The adjusted narrow sense heritability of kidney size parameters was estimated by maximum likelihood assuming multivariate normality after power transformation. Gender-specific reference centiles were generated for renal length according to body height in the subset of non-diabetic non-obese participants with normal renal function. RESULTS: We included 374 men and 419 women (mean ± SD, age 47 ± 18 and 48 ± 17 years, BMI 26.2 ± 4 and 24.5 ± 5 kg/m(2), respectively) from 205 families. Renal length was 11.4 ± 0.8 cm in men and 10.7 ± 0.8 cm in women; there was no difference between right and left renal length. Body height, weight and estimated glomerular filtration rate (eGFR) were positively associated with renal length, kidney function negatively, age quadratically, whereas gender and hypertension were not. The adjusted heritability estimates of renal length and volume were 47.3 ± 8.5 % and 45.5 ± 8.8 %, respectively (P < 0.001). CONCLUSION: The significant heritability of renal length and volume highlights the familial aggregation of this trait, independently of age and body size. Population-based references for renal length provide a useful guide for clinicians. KEY POINTS: • Renal length and volume are heritable traits, independent of age and size. • Based on a European population, gender-specific reference values/percentiles are provided for renal length. • Renal length correlates positively with body length and weight. • There was no difference between right and left renal lengths in this study. • This negates general teaching that the left kidney is larger and longer.
Resumo:
Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.
Resumo:
BACKGROUND AND OBJECTIVES: The determination of the carbon isotope ratio in androgen metabolites has been previously shown to be a reliable, direct method to detect testosterone misuse in the context of antidoping testing. Here, the variability in the 13C/12C ratios in urinary steroids in a widely heterogeneous cohort of professional soccer players residing in different countries (Argentina, Italy, Japan, South Africa, Switzerland and Uganda) is examined. METHODS: Carbon isotope ratios of selected androgens in urine specimens were determined using gas chromatography/combustion/isotope ratio mass spectrometry (GC-C-IRMS). RESULTS: Urinary steroids in Italian and Swiss populations were found to be enriched in 13C relative to other groups, reflecting higher consumption of C3 plants in these two countries. Importantly, detection criteria based on the difference in the carbon isotope ratio of androsterone and pregnanediol for each population were found to be well below the established threshold value for positive cases. CONCLUSIONS: The results obtained with the tested diet groups highlight the importance of adapting the criteria if one wishes to increase the sensitivity of exogenous testosterone detection. In addition, confirmatory tests might be rendered more efficient by combining isotope ratio mass spectrometry with refined interpretation criteria for positivity and subject-based profiling of steroids.
Resumo:
The level of information provided by ink evidence to the criminal and civil justice system is limited. The limitations arise from the weakness of the interpretative framework currently used, as proposed in the ASTM 1422-05 and 1789-04 on ink analysis. It is proposed to use the likelihood ratio from the Bayes theorem to interpret ink evidence. Unfortunately, when considering the analytical practices, as defined in the ASTM standards on ink analysis, it appears that current ink analytical practices do not allow for the level of reproducibility and accuracy required by a probabilistic framework. Such framework relies on the evaluation of the statistics of the ink characteristics using an ink reference database and the objective measurement of similarities between ink samples. A complete research programme was designed to (a) develop a standard methodology for analysing ink samples in a more reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in a forensic context. This report focuses on the first of the three stages. A calibration process, based on a standard dye ladder, is proposed to improve the reproducibility of ink analysis by HPTLC, when these inks are analysed at different times and/or by different examiners. The impact of this process on the variability between the repetitive analyses of ink samples in various conditions is studied. The results show significant improvements in the reproducibility of ink analysis compared to traditional calibration methods.
Resumo:
Workers performing preparation and administration of radiopharmaceuticals in NM departments are likely to receive high local skin doses to the hands which may even surpass the dose limit of 500 mSv whenever radiation protection standards are insufficient. A large measurement campaign was organised within the framework of the ORAMED project to determine the dose distribution across the hands received during preparation and administration of 18F- and 99mTc-labelled radiopharmaceuticals. The final data, collected over almost 3 years, include 641 measurements from 96 workers in 30 NM departments from 6 European countries. Results have provided levels of reference doses for the considered standard NM diagnostic procedures (mean maximum normalised skin dose of 230 μSv/GBq, 430 μSv/GBq, 930 μSv/GBq and 1200 μSv/GBq for the administration of 99mTc, preparation of 99mTc, administration of 18F and preparation of 18F, respectively). Finger dose was analysed as a function of the potential parameters of influence showing that shielding is the most efficient means of radiation protection to reduce skin dose. An appropriate method for routine monitoring of the extremities is also proposed: the base of the index finger of the non-dominant hand is a suitable position to place the ring dosemeter, with its sensitive part oriented towards the palm side; its reading may be multiplied by a factor of 6 to estimate the maximum local skin dose. Finally, results were compared to earlier published data, which correspond mostly to individual works with a reduced number of workers and measurements.