22 resultados para Spirometry.

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Age- and height-adjusted spirometric lung function of South Asian children is lower than those of white children. It is unclear whether this is purely genetic, or partly explained by the environment. In this study, we assessed whether cultural factors, socioeconomic status, intrauterine growth, environmental exposures, or a family and personal history of wheeze contribute to explaining the ethnic differences in spirometric lung function. METHODS: We studied children aged 9 to 14 years from a population-based cohort, including 1088 white children and 275 UK-born South Asians. Log-transformed spirometric data were analyzed using multiple linear regressions, adjusting for anthropometric factors. Five different additional models adjusted for (1) cultural factors, (2) indicators of socioeconomic status, (3) perinatal data reflecting intrauterine growth, (4) environmental exposures, and (5) personal and family history of wheeze. RESULTS: Height- and gender-adjusted forced vital capacity (FVC) and forced expired volume in 1 second (FEV1) were lower in South Asian than white children (relative difference -11% and -9% respectively, P < .001), but PEF and FEF50 were similar (P ≥ .5). FEV1/FVC was higher in South Asians (1.8%, P < .001). These differences remained largely unchanged in all 5 alternative models. CONCLUSIONS: Our study confirmed important differences in lung volumes between South Asian and white children. These were not attenuated after adjustment for cultural and socioeconomic factors and intrauterine growth, neither were they explained by differences in environmental exposures nor a personal or family history of wheeze. This suggests that differences in lung function may be mainly genetic in origin. The implication is that ethnicity-specific predicted values remain important specifically for South Asian children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to raise public awareness of the importance of early detection of airway obstruction and to enable many people who had not been tested previously to have their lung function measured, the European Lung Foundation and the European Respiratory Society (ERS) organised a spirometry testing tent during the annual ERS Congresses in 2004-2009. Spirometry was performed during the ERS Congresses in volunteers; all participants answered a simple, brief questionnaire on their descriptive characteristics, smoking and asthma. Portable spirometers were freely provided by the manufacturer. Nurses and doctors from pulmonary departments of local hospitals/universities gave their service for free. Lower limit of normal (LLN) and Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria for diagnosing and grading airway obstruction were used. Of 12,448 participants in six congress cities, 10,395 (83.5%) performed acceptable spirometry (mean age 51.0 ± 18.4 yrs; 25.5% smokers; 5.5% asthmatic). Airway obstruction was present in 12.4% of investigated subjects according to LLN criteria and 20.3% according to GOLD criteria. Through multinomial logistic regression analysis, age, smoking habits and asthma were significant risk factors for airway obstruction. Relative risk ratio and 95% confidence interval for LLN stage I, for example, was 2.9 (2.0-4.1) for the youngest age (≤ 19 yrs), 1.9 (1.2-3.0) for the oldest age (≥ 80 yrs), 2.4 (2.0-2.9) for current smokers and 2.8 (2.2-3.6) for reported asthma diagnosis. In addition to being a useful advocacy tool, the spirometry tent represents an unusual occasion for early detection of airway obstruction in large numbers of city residents with an important public health perspective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Spirometry reference values are important for the interpretation of spirometry results. Reference values should be updated regularly, derived from a population as similar to the population for which they are to be used and span across all ages. Such spirometry reference equations are currently lacking for central European populations. OBJECTIVE: To develop spirometry reference equations for central European populations between 8 and 90 years of age. MATERIALS: We used data collected between January 1993 and December 2010 from a central European population. The data was modelled using "Generalized Additive Models for Location, Scale and Shape" (GAMLSS). RESULTS: The spirometry reference equations were derived from 118'891 individuals consisting of 60'624 (51%) females and 58'267 (49%) males. Altogether, there were 18'211 (15.3%) children under the age of 18 years. CONCLUSION: We developed spirometry reference equations for a central European population between 8 and 90 years of age that can be implemented in a wide range of clinical settings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: A possible strategy for increasing smoking cessation rates could be to provide smokers who have contact with healthcare systems with feedback on the biomedical or potential future effects of smoking, e.g. measurement of exhaled carbon monoxide (CO), lung function, or genetic susceptibility to lung cancer. OBJECTIVES: To determine the efficacy of biomedical risk assessment provided in addition to various levels of counselling, as a contributing aid to smoking cessation. SEARCH STRATEGY: We systematically searched the Cochrane Collaboration Tobacco Addiction Group Specialized Register, Cochrane Central Register of Controlled Trials 2008 Issue 4, MEDLINE (1966 to January 2009), and EMBASE (1980 to January 2009). We combined methodological terms with terms related to smoking cessation counselling and biomedical measurements. SELECTION CRITERIA: Inclusion criteria were: a randomized controlled trial design; subjects participating in smoking cessation interventions; interventions based on a biomedical test to increase motivation to quit; control groups receiving all other components of intervention; an outcome of smoking cessation rate at least six months after the start of the intervention. DATA COLLECTION AND ANALYSIS: Two assessors independently conducted data extraction on each paper, with disagreements resolved by consensus. Results were expressed as a relative risk (RR) for smoking cessation with 95% confidence intervals (CI). Where appropriate a pooled effect was estimated using a Mantel-Haenszel fixed effect method. MAIN RESULTS: We included eleven trials using a variety of biomedical tests. Two pairs of trials had sufficiently similar recruitment, setting and interventions to calculate a pooled effect; there was no evidence that CO measurement in primary care (RR 1.06, 95% CI 0.85 to 1.32) or spirometry in primary care (RR 1.18, 95% CI 0.77 to 1.81) increased cessation rates. We did not pool the other seven trials. One trial in primary care detected a significant benefit of lung age feedback after spirometry (RR 2.12; 95% CI 1.24 to 3.62). One trial that used ultrasonography of carotid and femoral arteries and photographs of plaques detected a benefit (RR 2.77; 95% CI 1.04 to 7.41) but enrolled a population of light smokers. Five trials failed to detect evidence of a significant effect. One of these tested CO feedback alone and CO + genetic susceptibility as two different intervention; none of the three possible comparisons detected significant effects. Three others used a combination of CO and spirometry feedback in different settings, and one tested for a genetic marker. AUTHORS' CONCLUSIONS: There is little evidence about the effects of most types of biomedical tests for risk assessment. Spirometry combined with an interpretation of the results in terms of 'lung age' had a significant effect in a single good quality trial. Mixed quality evidence does not support the hypothesis that other types of biomedical risk assessment increase smoking cessation in comparison to standard treatment. Only two pairs of studies were similar enough in term of recruitment, setting, and intervention to allow meta-analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Bioaerosols and their constituents, such as endotoxins, are capable of causing an inflammatory reaction at the level of the lung-blood barrier, which becomes more permeable. Thus, it was hypothesized that occupational exposure to bioaerosols can increase leakage of surfactant protein-D (SP-D), a lung-specific protein, into the bloodstream. METHODS: SP-D was determined by ELISA in 316 wastewater workers, 67 garbage collectors, and 395 control subjects. Exposure was assessed with four interview-based indicators and by preliminary endotoxin measurements using the Limulus amoebocyte lysate assay. Influence of exposure on serum SP-D was assessed by multiple linear regression considering smoking, glomerular function, lung diseases, obesity, and other confounders. RESULTS: Overall, mean exposure levels to endotoxins were below 100 EU/m(3). However, special tasks of wastewater workers caused higher endotoxin exposure. SP-D concentration was slightly increased in this occupational group and associated with the occurrence of splashes and contact to raw sewage. No effect was found in garbage collectors. Smoking increased serum SP-D. No clinically relevant correlation between spirometry results and SP-D concentrations appeared. CONCLUSIONS: These results support the hypothesis that inhalation of bioaerosols, even at low concentrations, has a subclinical effect on the lung-blood barrier, the permeability of which increases without associated spirometric changes.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to examine the effect of a smoking ban on lung function, fractional exhaled nitric oxide, and respiratory symptoms in nonsmoking hospitality workers. METHODS: Secondhand smoke exposure at the workplace, spirometry, and fractional exhaled nitric oxide were measured in 92 nonsmoking hospitality workers before as well as twice after a smoking ban. RESULTS: At baseline, secondhand smoke-exposed hospitality workers had lung function values significantly below the population average. After the smoking ban, the covariate-adjusted odds ratio for cough was 0.59 (95% confidence interval, 0.36 to 0.93) and for chronic bronchitis 0.75 (95% confidence interval, 0.55 to 1.02) compared with the preban period. CONCLUSIONS: The below-average lung function before the smoking ban indicates chronic damages from long-term exposure. Respiratory symptoms such as cough decreased within 12 months after the ban.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Respiratory care is universally recognised as useful, but its indications and practice vary markedly. In order to improve appropriateness of respiratory care in our hospital, we developed evidence-based local guidelines in a collaborative effort involving physiotherapists, physicians, and health services researchers. Methods: Recommendations were developed using the standardised RAND appropriateness method. A literature search was performed for the period between 1995 and 2008 based on terms associated with guidelines and with respiratory care. Publications were assessed according to the Oxford classification of quality of evidence. A working group prepared proposals for recommendations which were then independently rated by a multidisciplinary expert panel. All recommendations were then discussed in common and indications for procedures were rated confidentially a second time by the experts. Each indication for respiratory care was classified as appropriate, uncertain, or inappropriate, based on the panel median rating and the degree of intra-panel agreement. Results: Recommendations were formulated for the following procedures: non-invasive ventilation, continuous positive airway pressure, intermittent positive pressure breathing, intrapulmonary percussive ventilation, mechanical insufflation-exsufflation, incentive spirometry, positive expiratory pressure, nasotracheal suctioning, noninstrumental airway clearance techniques. Each recommendation referred to a particular medical condition, and was assigned to a hierarchical category based on the quality of evidence from literature supporting the recommendation and on the consensus of experts. Conclusion: Despite a marked heterogeneity of scientific evidence, the method used allowed us to develop commonly agreed local guidelines for respiratory care. In addition, this work fostered a closer relationship between physiotherapists and physicians in our institution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Decreasing exposure to airborne particulates was previously associated with reduced age-related decline in lung function. However, whether the benefit from improved air quality depends on genetic background is not known. Recent evidence points to the involvement of the genes p53 and p21 and of the cell cycle control gene cyclin D1 (CCND1) in the response of bronchial cells to air pollution. OBJECTIVE: We determined in 4,326 participants of the Swiss Cohort Study on Air Pollution and Lung and Heart Diseases in Adults (SAPALDIA) whether four single-nucleotide polymorphisms in three genes [CCND1 (rs9344 [P242P], rs667515), p53 (rs1042522 [R72P]), and p21 (rs1801270 [S31R])] modified the previously observed attenuation of the decline in the forced expiratory flow between 25% and 75% of the forced vital capacity (FEF(25-75)) associated with improved air quality. METHODS: Subjects of the prospective population-based SAPALDIA cohort were assessed in 1991 and 2002 by spirometry, questionnaires, and biological sample collection for genotyping. We assigned spatially resolved concentrations of particulate matter with aerodynamic diameter < or = 10 microm (PM(10)) to each participant's residential history 12 months before the baseline and follow-up assessments. RESULTS: The effect of diminishing PM(10) exposure on FEF(25-75) decline appeared to be modified by p53 R72P, CCND1 P242P, and CCND1 rs667515. For example, a 10-microg/m(3) decline in average PM(10) exposure over an 11-year period attenuated the average annual decline in FEF(25-75) by 21.33 mL/year (95% confidence interval, 10.57-32.08) among participants homozygous for the CCND1 (P242P) GG genotype, by 13.72 mL/year (5.38-22.06) among GA genotypes, and by 6.00 mL/year (-4.54 to 16.54) among AA genotypes. CONCLUSIONS: Our results suggest that cell cycle control genes may modify the degree to which improved air quality may benefit respiratory function in adults.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Bioaerosols such as grain dust (GD) elicit direct immunological reactions within the human respiratory system. Workplace-dependent exposure to GD may induce asthma, chronic bronchitis, and hypersensitivity pneumonitis. Aims: To assess the clinical impact of occupational exposure to GD and to determine quantitative biological markers of bioaerosol exposure in grain workers. Methods: This longitudinal study has been conducted from summer 2012 to summer 2013, comprising 6 groups of 30 active workers with different GD exposure patterns (4 groups of grain workers, 2 control groups). Two evaluations at high- and low-exposing seasons take place, during which an occupational and a medical history are questionnaire-assessed, lung function is evaluated by spirometry, airway inflammation is measured by exhaled nitric oxide (eNO) and specific blood IgG and IgE are titrated. Results: The preliminary results are those of 2 of the 4 exposed groups, (harvesters and mill workers), compared to the control groups, at first assessment (n=100). Mean age is 38.4 [years]; 98% are male. Exposed groups differ from controls (p<0.05) in daily contact with animals (57% vs. 40%) and active smoking (39% vs. 11%). Grain workers have more respiratory (50%), nasal (57%), ocular (45%) and dermatologic (36%) occupational symptoms than controls (6.4%, 19%, 16%, 6.4% respectively, p<0.05). Lower mean peak-expiratory-flow (PEF) values (96.1 ± 18.9 vs. 108.2 ± 17.4 [% of predicted], p<0.05) and eNO values (13.9 ± 9.6 vs. 20.5 ± 14.7 [ppm], p<0.05) are observed in the exposed groups. Conclusion: Preliminary results show a higher prevalence of clinical symptoms and a lower mean PEF value in the groups exposed to GD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PRINCIPLES: Respiratory care is universally recognised as useful, but its indications and practice vary markedly. In order to improve the appropriateness of respiratory care in our hospital, we developed evidence-based local guidelines in a collaborative effort involving physiotherapists, physicians and health service researchers. METHODS: Recommendations were developed using the standardised RAND appropriateness method. A literature search was conducted based on terms associated with guidelines and with respiratory care. A working group prepared proposals for recommendations which were then independently rated by a multidisciplinary expert panel. All recommendations were then discussed in common and indications for procedures were rated confidentially a second time by the experts. The recommendations were then formulated on the basis of the level of evidence in the literature and on the consensus among these experts. RESULTS: Recommendations were formulated for the following procedures: non-invasive ventilation, continuous positive airway pressure, intermittent positive pressure breathing, intrapulmonary percussive ventilation, mechanical insufflation-exsufflation, incentive spirometry, positive expiratory pressure, nasotracheal suctioning and non-instrumental airway clearance techniques. Each recommendation referred to a particular medical condition and was assigned to a hierarchical category based on the quality of the evidence from the literature supporting the recommendation and on the consensus among the experts. CONCLUSION: Despite a marked heterogeneity of scientific evidence, the method used allowed us to develop commonly agreed local guidelines for respiratory care. In addition, this work fostered a closer relationship between physiotherapists and physicians in our institution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Chronic obstructive pulmonary disease (COPD) has been associated with increased risk for heart failure (HF). The impact of subclinical abnormal spirometric findings on HF risk among older adults without history of COPD is not well elucidated. Methods: We evaluated 2125 participants (age 73.6±2.9 years; 50.5% men; 62.3% white; 45.6/9.4% past/current smokers; body mass index [BMI] 27.2±4.6 kg/m2) without prevalent COPD or HF who underwent baseline spirometry in the Health ABC Study. Abnormal lung function was defined either as forced vital capacity (FVC) below lower limit of normal (LLN) or forced expiratory volume in 1st sec (FEV1) to FVC ratio below LLN. Results: On follow-up (median, 9.4 years), 68 of 350 (19.4%) participants with abnormal lung function developed HF, as compared to 172 of 1775 (9.7%) participants with normal lung function (hazard ratio [HR], 2.31; 95% confidence interval [CI], 1.74 -3.06; P<.001). This increased risk persisted after adjusting for all other independent predictors of HF in the Health ABC Study, BMI, incident coronary events, and several inflammatory markers (HR, 1.82; 95% CI, 1.30 -2.54; P<.001), and remained constant over time. Baseline FVC and FEV1 had a linear association with HF risk (Figure). In adjusted models, HF risk increased by 21% (95% CI, 10 -36%) per 10% decrease in FVC and 18% (95% CI, 10 -28%) per 10% decrease in FEV1 (both P<.001); this association persisted among participants with normal lung function at baseline. Findings were consistent across sex, race, and smoking status. Conclusions: Subclinical abnormal spirometric findings are prevalent among older adults and are independently associated with risk for incident HF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bronchiolitis obliterans (BO) following allogeneic haematopoietic stem cell transplantation (HSCT) affects peripheral airways. Detection of BO is presently delayed by the low sensitivity of spirometry. We examined the relationship between peripheral airway function and time since HSCT, and compared it with spirometry and clinical indices in 33 clinically stable allogeneic HSCT recipients. The following measurements were performed: lung function, exhaled nitric oxide, forced oscillatory respiratory system resistance and reactance, acinar (S(acin)) and conductive airways ventilation heterogeneity and lung clearance index (LCI) measured by multiple breath nitrogen washout. 22 patients underwent repeat visits from which short-term changes were examined. Median time post HSCT was 12 months. Eight patients were clinically diagnosed as having BO. In multivariate analysis, time since HSCT was predicted by S(acin) and forced expiratory volume in 1 s % predicted. 20 patients had abnormal S(acin) with normal spirometry, whereas none had airflow obstruction with normal S(acin). S(acin) and LCI were the only measures to change significantly between two visits, with both worsening. Change in S(acin) was the only parameter to correlate with change in chronic graft-versus-host disease grade. In conclusion, peripheral airways ventilation heterogeneity worsens with time after HSCT. S(acin) may be more sensitive than spirometry in detecting BO at an early stage, which needs confirmation in a prospective study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Bioaerosols such as grain dust, via biologically active agents, elicit local inflammation and direct immunological reactions within the human respiratory system. Workplace-dependent exposure to grain dust (GD) may thus induce asthma, chronic bronchitis, and hypersensitivity pneumonitis. The aim of this study is to assess the clinical impact of occupational exposure to GD and to determine quantitative biological markers of bioaerosol exposure in grain workers. Methods: This longitudinal study has been conducted from summer 2012, to summer 2013, comprising 6 groups of 30 active workers with different GD exposure patterns (4 groups of grain workers, 2 control groups). After obtaining informed consent, two evaluations at high- and low-exposing seasons take place, during which an occupational history and a detailed medical history are questionnaire-assessed, lung function is evaluated by spirometry, airway inflammation is measured by exhaled nitric oxide (eNO), and specific blood IgG and IgE are titrated. The preliminary results presented hereafter are those of two of the four exposed groups, namely harvesters and mill workers, compared to the control groups, at first assessment (n=100). Results: Mean age is 38.4 [years]; 98% are male. Exposed groups differ from controls (p<0.05) in daily contact with animals (57% vs. 40%) and active smoking (39% vs. 11%). Grain workers have more respiratory (50%), nasal (57%), ocular (45%), dermatologic (36%) and systemic (20%) occupational symptoms than controls (6.4%, 19%, 16%, 6.4%, 1.6% respectively, p<0.05). Lower mean peak-expiratory-flow (PEF) values (96.1 ± 18.9 vs. 108.2 ± 17.4 [% of predicted], p<0.05) and eNO values (13.9 ± 9.6 vs. 20.5 ± 14.7 [ppm], p<0.05) are observed in the exposed groups. Conclusion: Preliminary results show a higher prevalence of clinical symptoms and a lower mean PEF value in the exposed groups. Detailed supplementary analyses are pending.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: Fabry disease is an X-linked genetic disorder due to deficiency of the lysosomal enzyme a-galactosidase A, which leads to the accumulation of neutral glycosphingolipids within the lysosomes of almost all tissues. Clinical manifestations usually include acroparaesthesia, renal insufficiency and cardiomyopathy. Recently, pulmonary manifestations consisting of progressive obstructive airway disease have been reported. The aim of this study was to analyse the cross-sectional prevalence of airflow obstruction in a Swiss cohort of patients, and in selected cases, to evaluate the impact of enzyme replacement therapy (ERT) with agalsidase alfa (ReplagalTM; TKT - 5S). Methods: Forty-four patients (27 men, 17 women) were included in the study and received pulmonary function testing. Fifteen patients underwent spirometry after ERT. Results: Twelve patients (nine men) had chronic obstructive pulmonary disease according to the Global Obstructive Lung Disease (GOLD) initiative criteria: forced expiratory volume (FEV1)/forced vital capacity (FVC) 50.7), but only one was an active smoker and one a previous smoker. FEV1/ FVC as percentage predicted was weakly correlated with age (r=0.42, p=0.005, calculated by Pearson product-moment correlation), demonstrating that airway obstruction occurs in the late stages of the disease. Median FEV1 in patients with obstruction was 67% of predicted (range, 45-90%). Reversibility of FEV1 after b2-agonist inhalation never exceeded 8% of predicted. Diffusing capacity of the lung for carbon monoxide (DLCO) was measured in 13 individuals with a median of 88% of predicted (range, 39-125%). After 15+9 months of ERT, spirometry measurements were recorded in 15 patients. Decline in FEV1 was -2+5% of predicted. (p40.05, measured by the Wilcoxon signed-rank test). Median change in DLCO was -10% of predicted (-40 to +25%, p40.05). High resolution computed tomography scans demonstrated a moderate thickening of the bronchial wall in affected individuals, without evidence of emphysema. Conclusion: We conclude that Fabry disease can be complicated by significant airway obstruction, particularly in patients in the advanced stages of the disease, and that in the period studied, ERT had no demonstrable impact on pulmonary function.