31 resultados para Sodium acetate buffer pH 4.0

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A selective and sensitive method was developed for the simultaneous quantification of seven typical antipsychotic drugs (cis-chlorprothixene, flupentixol, haloperidol, levomepromazine, pipamperone, promazine and zuclopenthixol) in human plasma. Ultra-high performance liquid chromatography (UHPLC) was used for complete separation of the compounds in less than 4.5min on an Acquity UPLC BEH C18 column (2.1mm×50mm; 1.7μm), with a gradient elution of ammonium formate buffer pH 4.0 and acetonitrile at a flow rate of 400μl/min. Detection was performed on a tandem quadrupole mass spectrometer (MS/MS) equipped with an electrospray ionization interface. A simple protein precipitation procedure with acetonitrile was used for sample preparation. Thanks to the use of stable isotope-labeled internal standards for all analytes, internal standard-normalized matrix effects were in the range of 92-108%. The method was fully validated to cover large concentration ranges of 0.2-90ng/ml for haloperidol, 0.5-90ng/ml for flupentixol, 1-450ng/ml for levomepromazine, promazine and zuclopenthixol and 2-900ng/ml for cis-chlorprothixene and pipamperone. Trueness (89.1-114.8%), repeatability (1.8-9.9%), intermediate precision (1.9-16.3%) and accuracy profiles (<30%) were in accordance with the latest international recommendations. The method was successfully used in our laboratory for routine quantification of more than 500 patient plasma samples for therapeutic drug monitoring. To the best of our knowledge, this is the first UHPLC-MS/MS method for the quantification of the studied drugs with a sample preparation based on protein precipitation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The metabolic and respiratory effects of intravenous 0.5 M sodium acetate (at a rate of 2.5 mmol/min during 120 min) were studied in nine normal human subjects. O2 consumption (VO2) and CO2 production (VCO2) were measured continuously by open-circuit indirect calorimetry. VO2 increased from 251 +/- 9 to 281 +/- 9 ml/min (P < 0.001), energy expenditure increased from 4.95 +/- 0.17 kJ/min baseline to 5.58 +/- 0.16 kJ/min (P < 0.001), and VCO2 decreased nonsignificantly (211 +/- 7 ml/min vs. 202 +/- 7 ml/min, NS). The extrapulmonary CO2 loss (i.e., bicarbonate generation and excretion) was estimated at 48 +/- 5 ml/min. This observation is consistent with 1 mol of bicarbonate generated from 1 mol of acetate metabolized. Alveolar ventilation decreased from 3.5 +/- 0.2 l/min basal to 3.1 +/- 0.2 l/min (P < 0.001). The minute ventilation (VE) to VO2 ratio decreased from 22.9 +/- 1.3 to 17.6 +/- 0.9 l/l (P < 0.005), arterial PO2 decreased from 93.2 +/- 1.9 to 78.7 +/- 1.6 mmHg (P < 0.0001), arterial PCO2 increased from 39.2 +/- 0.7 to 42.1 +/- 1.1 mmHg (P < 0.0001), pH from 7.40 +/- 0.005 to 7.50 +/- 0.007 (P < 0.005), and arterial bicarbonate concentration from 24.2 +/- 0.7 to 32.9 +/- 1.1 (P < 0.0001). These observations indicate that sodium acetate infusion results in substantial extrapulmonary CO2 loss, which leads to a relative decrease of total and alveolar ventilation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chromatographic separation of highly polar basic drugs with ideal ionspray mass spectrometry volatile mobile phases is a difficult challenge. A new quantification procedure was developed using hydrophilic interaction chromatography-mass spectrometry with turbo-ionspray ionization in the positive mode. After addition of deuterated internal standards and simple clean-up liquid extraction, the dried extracts were reconstituted in 500 microL pure acetonitrile and 5 microL was directly injected onto a Waters Atlantis HILIC 150- x 2.1-mm, 3-microm column. Chromatographic separations of cocaine, seven metabolites, and anhydroecgonine were obtained by linear gradient-elution with decreasing high concentrations of acetonitrile (80-56% in 18 min). This high proportion of organic solvent makes it easier to be coupled with MS. The eluent was buffered with 2 mM ammonium acetate at pH 4.5. Except for m-hydroxy-benzoylecgonine, the within-day and between-day precisions at 20, 100, and 500 ng/mL were below 7 and 19.1%, respectively. Accuracy was also below +/- 13.5% at all tested concentrations. The limit of quantification was 5 ng/mL (%Diff < 16.1, %RSD < 4.3) and the limit of detection below 0.5 ng/mL. This method was successfully applied to a fatal overdose. In Switzerland, cocaine abuse has dramatically increased in the last few years. A 45-year-old man, a known HIV-positive drug user, was found dead at home. According to relatives, cocaine was self-injected about 10 times during the evening before death. A low amount of cocaine (0.45 mg) was detected in the bloody fluid taken from a syringe discovered near the corpse. Besides injection marks, no significant lesions were detected during the forensic autopsy. Toxicological investigations showed high cocaine concentrations in all body fluids and tissues. The peripheral blood concentrations of cocaine, benzoylecgonine, and methylecgonine were 5.0, 10.4, and 4.1 mg/L, respectively. The brain concentrations of cocaine, benzoylecgonine, and methylecgonine were 21.2, 3.8, and 3.3 mg/kg, respectively. The highest concentrations of norcocaine (about 1 mg/L) were measured in bile and urine. Very high levels of cocaine were determined in hair (160 ng/mg), indicating chronic cocaine use. A low concentration of anhydroecgonine methylester was also found in urine (0.65 mg/L) suggesting recent cocaine inhalation. Therapeutic blood concentrations of fluoxetine (0.15 mg/L) and buprenorphine (0.1 microg/L) were also discovered. A relatively high concentration of Delta(9)-THC was measured both in peripheral blood (8.2 microg/L) and brain cortex (13.5 microg/kg), suggesting that the victim was under the influence of cannabis at the time of death. In addition, fluoxetine might have enhanced the toxic effects of cocaine because of its weak pro-arrhythmogenic properties. Likewise, combination of cannabinoids and cocaine might have increase detrimental cardiovascular effects. Altogether, these results indicate a lethal cocaine overdose with a minor contribution of fluoxetine and cannabinoids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Metabolic problems lead to numerous failures during clinical trials, and much effort is now devoted to developing in silico models predicting metabolic stability and metabolites. Such models are well known for cytochromes P450 and some transferases, whereas less has been done to predict the activity of human hydrolases. The present study was undertaken to develop a computational approach able to predict the hydrolysis of novel esters by human carboxylesterase hCES2. The study involved first a homology modeling of the hCES2 protein based on the model of hCES1 since the two proteins share a high degree of homology (congruent with 73%). A set of 40 known substrates of hCES2 was taken from the literature; the ligands were docked in both their neutral and ionized forms using GriDock, a parallel tool based on the AutoDock4.0 engine which can perform efficient and easy virtual screening analyses of large molecular databases exploiting multi-core architectures. Useful statistical models (e.g., r (2) = 0.91 for substrates in their unprotonated state) were calculated by correlating experimental pK(m) values with distance between the carbon atom of the substrate's ester group and the hydroxy function of Ser228. Additional parameters in the equations accounted for hydrophobic and electrostatic interactions between substrates and contributing residues. The negatively charged residues in the hCES2 cavity explained the preference of the enzyme for neutral substrates and, more generally, suggested that ligands which interact too strongly by ionic bonds (e.g., ACE inhibitors) cannot be good CES2 substrates because they are trapped in the cavity in unproductive modes and behave as inhibitors. The effects of protonation on substrate recognition and the contrasting behavior of substrates and products were finally investigated by MD simulations of some CES2 complexes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The 24-item Brief Psychiatric Rating Scale (BPRS, version 4.0) enables the rater to measure psychopathology severity. Still, little is known about the BPRS's reliability and validity outside of the psychosis spectrum. The aim of this study was to examine the factorial structure and sensitivity to change of the BPRS in patients with unipolar depression. Two hundred and forty outpatients with unipolar depression were administered the 24-item BPRS. Assessments were conducted at intake and at post-treatment in a Crisis Intervention Centre. An exploratory factor analysis of the 24-item BPRS produced a six-factor solution labelled "Mood disturbance", "Reality distortion", "Activation", "Apathy", "Disorganization", and "Somatization". The reduction of the total BPRS score and dimensional scores, except for "Activation", indicates that the 24-item BPRS is sensitive to change as shown in patients that appeared to have benefited from crisis treatment. The findings suggest that the 24-item BPRS could be a useful instrument to measure symptom severity and change in symptom status in outpatients presenting with unipolar depression.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among the various determinants of treatment response, the achievement of sufficient blood levels is essential for curing malaria. For helping us at improving our current understanding of antimalarial drugs pharmacokinetics, efficacy and toxicity, we have developed a liquid chromatography-tandem mass spectrometry method (LC-MS/MS) requiring 200mul of plasma for the simultaneous determination of 14 antimalarial drugs and their metabolites which are the components of the current first-line combination treatments for malaria (artemether, artesunate, dihydroartemisinin, amodiaquine, N-desethyl-amodiaquine, lumefantrine, desbutyl-lumefantrine, piperaquine, pyronaridine, mefloquine, chloroquine, quinine, pyrimethamine and sulfadoxine). Plasma is purified by a combination of protein precipitation, evaporation and reconstitution in methanol/ammonium formate 20mM (pH 4.0) 1:1. Reverse-phase chromatographic separation of antimalarial drugs is obtained using a gradient elution of 20mM ammonium formate and acetonitrile both containing 0.5% formic acid, followed by rinsing and re-equilibration to the initial solvent composition up to 21min. Analyte quantification, using matrix-matched calibration samples, is performed by electro-spray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection in the positive mode. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effect variability, overall process efficiency, standard addition experiments as well as antimalarials short- and long-term stability in plasma. The reactivity of endoperoxide-containing antimalarials in the presence of hemolysis was tested both in vitro and on malaria patients samples. With this method, signal intensity of artemisinin decreased by about 20% in the presence of 0.2% hemolysed red-blood cells in plasma, whereas its derivatives were essentially not affected. The method is precise (inter-day CV%: 3.1-12.6%) and sensitive (lower limits of quantification 0.15-3.0 and 0.75-5ng/ml for basic/neutral antimalarials and artemisinin derivatives, respectively). This is the first broad-range LC-MS/MS assay covering the currently in-use antimalarials. It is an improvement over previous methods in terms of convenience (a single extraction procedure for 14 major antimalarials and metabolites reducing significantly the analytical time), sensitivity, selectivity and throughput. While its main limitation is investment costs for the equipment, plasma samples can be collected in the field and kept at 4 degrees C for up to 48h before storage at -80 degrees C. It is suited to detecting the presence of drug in subjects for screening purposes and quantifying drug exposure after treatment. It may contribute to filling the current knowledge gaps in the pharmacokinetics/pharmacodynamics relationships of antimalarials and better define the therapeutic dose ranges in different patient populations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The treatment of some cancer patients has shifted from traditional, non-specific cytotoxic chemotherapy to chronic treatment with molecular targeted therapies. Imatinib mesylate, a selective inhibitor of tyrosine kinases (TKIs) is the most prominent example of this new era and has opened the way to the development of several additional TKIs, including sunitinib, nilotinib, dasatinib, sorafenib and lapatinib, in the treatment of various hematological malignancies and solid tumors. All these agents are characterized by an important inter-individual pharmacokinetic variability, are at risk for drug interactions, and are not devoid of toxicity. Additionally, they are administered for prolonged periods, anticipating the careful monitoring of their plasma exposure via Therapeutic Drug Monitoring (TDM) to be an important component of patients' follow-up. We have developed a liquid chromatography-tandem mass spectrometry method (LC-MS/MS) requiring 100 microL of plasma for the simultaneous determination of the six major TKIs currently in use. Plasma is purified by protein precipitation and the supernatant is diluted in ammonium formate 20 mM (pH 4.0) 1:2. Reverse-phase chromatographic separation of TKIs is obtained using a gradient elution of 20 mM ammonium formate pH 2.2 and acetonitrile containing 1% formic acid, followed by rinsing and re-equilibration to the initial solvent composition up to 20 min. Analyte quantification, using matrix-matched calibration samples, is performed by electro-spray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effects variability (<9.6%), overall process efficiency (87.1-104.2%), as well as TKIs short- and long-term stability in plasma. The method is precise (inter-day CV%: 1.3-9.4%), accurate (-9.2 to +9.9%) and sensitive (lower limits of quantification comprised between 1 and 10 ng/mL). This is the first broad-range LC-MS/MS assay covering the major currently in-use TKIs. It is an improvement over previous methods in terms of convenience (a single extraction procedure for six major TKIs, reducing significantly the analytical time), sensitivity, selectivity and throughput. It may contribute to filling the current knowledge gaps in the pharmacokinetics/pharmacodynamics relationships of the latest TKIs developed after imatinib and better define their therapeutic ranges in different patient populations in order to evaluate whether a systematic TDM-guided dose adjustment of these anticancer drugs could contribute to minimize the risk of major adverse reactions and to increase the probability of efficient, long lasting, therapeutic response.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sensitive and selective ultra-high performance liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS) method was developed for the fast quantification of ten psychotropic drugs and metabolites in human plasma for the needs of our laboratory (amisulpride, asenapine, desmethyl-mirtazapine, iloperidone, mirtazapine, norquetiapine, olanzapine, paliperidone, quetiapine and risperidone). Stable isotope-labeled internal standards were used for all analytes, to compensate for the global method variability, including extraction and ionization variations. Sample preparation was performed by generic protein precipitation with acetonitrile. Chromatographic separation was achieved in less than 3.0min on an Acquity UPLC BEH Shield RP18 column (2.1mm×50mm; 1.7μm), using a gradient elution of 10mM ammonium formate buffer pH 3.0 and acetonitrile at a flow rate of 0.4ml/min. The compounds were quantified on a tandem quadrupole mass spectrometer operating in positive electrospray ionization mode, using multiple reaction monitoring. The method was fully validated according to the latest recommendations of international guidelines. Eight point calibration curves were used to cover a large concentration range 0.5-200ng/ml for asenapine, desmethyl-mirtazapine, iloperidone, mirtazapine, olanzapine, paliperidone and risperidone, and 1-1500ng/ml for amisulpride, norquetiapine and quetiapine. Good quantitative performances were achieved in terms of trueness (93.1-111.2%), repeatability (1.3-8.6%) and intermediate precision (1.8-11.5%). Internal standard-normalized matrix effects ranged between 95 and 105%, with a variability never exceeding 6%. The accuracy profiles (total error) were included in the acceptance limits of ±30% for biological samples. This method is therefore suitable for both therapeutic drug monitoring and pharmacokinetic studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A previously developed high performance liquid chromatography mass spectrometry (HPLC-MS) procedure for the simultaneous determination of antidementia drugs, including donepezil, galantamine, memantine, rivastigmine and its metabolite NAP 226-90, was transferred to an ultra performance liquid chromatography system coupled to a tandem mass spectrometer (UPLC-MS/MS). The drugs and their internal standards ([(2)H(7)]-donepezil, [(13)C,(2)H(3)]-galantamine, [(13)C(2),(2)H(6)]-memantine, [(2)H(6)]-rivastigmine) were extracted from 250μL human plasma by protein precipitation with acetonitrile. Chromatographic separation was achieved on a reverse phase column (BEH C18 2.1mm×50mm; 1.7μm) with a gradient elution of an ammonium acetate buffer at pH 9.3 and acetonitrile at a flow rate of 0.4mL/min and an overall run time of 4.5min. The analytes were detected on a tandem quadrupole mass spectrometer operated in positive electrospray ionization mode, and quantification was performed using multiple reaction monitoring. The method was validated according to the recommendations of international guidelines over a calibration range of 1-300ng/mL for donepezil, galantamine and memantine, and 0.2-50ng/mL for rivastimgine and NAP 226-90. The trueness (86-108%), repeatability (0.8-8.3%), intermediate precision (2.3-10.9%) and selectivity of the method were found to be satisfactory. Matrix effects variability was inferior to 15% for the analytes and inferior to 5% after correction by internal standards. A method comparison was performed with patients' samples showing similar results between the HPLC-MS and UPLC-MS/MS procedures. Thus, this validated UPLC-MS/MS method allows to reduce the required amount of plasma, to use a simplified sample preparation, and to obtain a higher sensitivity and specificity with a much shortened run-time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PAH (N-(4-aminobenzoyl)glycin) clearance measurements have been used for 50 years in clinical research for the determination of renal plasma flow. The quantitation of PAH in plasma or urine is generally performed by colorimetric method after diazotation reaction but the measurements must be corrected for the unspecific residual response observed in blank plasma. We have developed a HPLC method to specifically determine PAH and its metabolite NAc-PAH using a gradient elution ion-pair reversed-phase chromatography with UV detection at 273 and 265 nm, respectively. The separations were performed at room temperature on a ChromCart (125 mmx4 mm I.D.) Nucleosil 100-5 microm C18AB cartridge column, using a gradient elution of MeOH-buffer pH 3.9 1:99-->15:85 over 15 min. The pH 3.9 buffered aqueous solution consisted in a mixture of 375 ml sodium citrate-citric acid solution (21.01 g citric acid and 8.0 g NaOH per liter), added up with 2.7 ml H3PO4 85%, 1.0 g of sodium heptanesulfonate and completed ad 1000 ml with ultrapure water. The N-acetyltransferase activity does not seem to notably affect PAH clearances, although NAc-PAH represents 10.2+/-2.7% of PAH excreted unchanged in 12 healthy subjects. The performance of the HPLC and the colorimetric method have been compared using urine and plasma samples collected from healthy volunteers. Good correlations (r=0.94 and 0.97, for plasma and urine, respectively) are found between the results obtained with both techniques. However, the colorimetric method gives higher concentrations of PAH in urine and lower concentrations in plasma than those determined by HPLC. Hence, both renal (ClR) and systemic (Cls) clearances are systematically higher (35.1 and 17.8%, respectively) with the colorimetric method. The fraction of PAH excreted by the kidney ClR/ClS calculated from HPLC data (n=143) is, as expected, always <1 (mean=0.73+/-0.11), whereas the colorimetric method gives a mean extraction ratio of 0.87+/-0.13 implying some unphysiological values (>1). In conclusion, HPLC not only enables the simultaneous quantitation of PAH and NAc-PAH, but may also provide more accurate and precise PAH clearance measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gastrin-releasing peptide receptors (GRPrs) are overexpressed on a variety of human cancers, providing the opportunity for peptide receptor targeting via radiolabeled bombesin-based peptides. As part of our ongoing investigations into the development of improved GRPr antagonists, this study aimed at verifying whether and how N-terminal modulations improve the affinity and pharmacokinetics of radiolabeled GRPr antagonists. METHODS: The potent GRPr antagonist MJ9, Pip-d-Phe-Gln-Trp-Ala-Val-Gly-His-Sta-Leu-NH2 (Pip, 4-amino-1-carboxymethyl-piperidine), was conjugated to 1,4,7-triazacyclononane, 1-glutaric acid-4,7 acetic acid (NODAGA), and 1,4,7-triazacyclononane-1,4,7-triacetic acid (NOTA) and radiolabeled with (68)Ga and (64)Cu. The GRPr affinity of the corresponding metalloconjugates was determined using (125)I-Tyr(4)-BN as a radioligand. The labeling efficiency of (68)Ga(3+) was compared between NODAGA-MJ9 and NOTA-MJ9 in acetate buffer, at room temperature and at 95°C. The (68)Ga and (64)Cu conjugates were further evaluated in vivo in PC3 tumor xenografts by biodistribution and PET imaging studies. RESULTS: The half maximum inhibitory concentrations of all the metalloconjugates are in the high picomolar-low nanomolar range, and these are the most affine-radiolabeled GRPr antagonists we have studied so far in our laboratory. NODAGA-MJ9 incorporates (68)Ga(3+) nearly quantitatively (>98%) at room temperature within 10 min and at much lower peptide concentrations (1.4 × 10(-6) M) than NOTA-MJ9, for which the labeling yield was approximately 45% under the same conditions and increased to 75% at 95°C for 5 min. Biodistribution studies showed high and specific tumor uptake, with a maximum of 23.3 ± 2.0 percentage injected activity per gram of tissue (%IA/g) for (68)Ga-NOTA-MJ9 and 16.7 ± 2.0 %IA/g for (68)Ga-NODAGA-MJ9 at 1 h after injection. The acquisition of PET images with the (64)Cu-MJ9 conjugates at later time points clearly showed the efficient clearance of the accumulated activity from the background already at 4 h after injection, whereas tumor uptake still remained high. The high pancreas uptake for all radiotracers at 1 h after injection was rapidly washed out, resulting in an increased tumor-to-pancreas ratio at later time points. CONCLUSION: We have developed 2 GRPr antagonistic radioligands, which are improved in terms of binding affinity and overall biodistribution profile. Their promising in vivo pharmacokinetic performance may contribute to the improvement of the diagnostic imaging of tumors overexpressing GRPr.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sensitive and specific ultra performance liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of nicotine, its metabolites cotinine and trans-3'-hydroxycotinine and varenicline in human plasma was developed and validated. Sample preparation was realized by solid phase extraction of the target compounds and of the internal standards (nicotine-d4, cotinine-d3, trans-3'-hydroxycotinine-d3 and CP-533,633, a structural analog of varenicline) from 0.5mL of plasma, using a mixed-mode cation exchange support. Chromatographic separations were performed on a hydrophilic interaction liquid chromatography column (HILIC BEH 2.1×100mm, 1.7μm). A gradient program was used, with a 10mM ammonium formate buffer pH 3/acetonitrile mobile phase at a flow of 0.4mL/min. The compounds were detected on a triple quadrupole mass spectrometer, operated with an electrospray interface in positive ionization mode and quantification was performed using multiple reaction monitoring. Matrix effects were quantitatively evaluated with success, with coefficients of variation inferior to 8%. The procedure was fully validated according to Food and Drug Administration guidelines and to Société Française des Sciences et Techniques Pharmaceutiques. The concentration range was 2-500ng/mL for nicotine, 1-1000ng/mL for cotinine, 2-1000ng/mL for trans-3'-hydroxycotinine and 1-500ng/mL for varenicline, according to levels usually measured in plasma. Trueness (86.2-113.6%), repeatability (1.9-12.3%) and intermediate precision (4.4-15.9%) were found to be satisfactory, as well as stability in plasma. The procedure was successfully used to quantify nicotine, its metabolites and varenicline in more than 400 plasma samples from participants in a clinical study on smoking cessation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: A rapid and simple HPLC-MS method was developed for the simultaneousdetermination of antidementia drugs, including donepezil, galantamine, rivastigmineand its major metabolite NAP 226 - 90, and memantine, for TherapeuticDrug Monitoring (TDM). In the elderly population treated with antidementiadrugs, the presence of several comorbidities, drug interactions resulting frompolypharmacy, and variations in drug metabolism and elimination, are possiblefactors leading to the observed high interindividual variability in plasma levels.Although evidence for the benefit of TDM for antidementia drugs still remains tobe demonstrated, an individually adapted dosage through TDM might contributeto minimize the risk of adverse reactions and to increase the probability of efficienttherapeutic response. Methods: A solid-phase extraction procedure with amixed-mode cation exchange sorbent was used to isolate the drugs from 0.5 mL ofplasma. The compounds were analyzed on a reverse-phase column with a gradientelution consisting of an ammonium acetate buffer at pH 9.3 and acetonitrile anddetected by mass spectrometry in the single ion monitoring mode. Isotope-labeledinternal standards were used for quantification where possible. The validatedmethod was used to measure the plasma levels of antidementia drugs in 300patients treated with these drugs. Results: The method was validated accordingto international standards of validation, including the assessment of the trueness(-8 - 11 %), the imprecision (repeatability: 1-5%, intermediate imprecision:2 - 9 %), selectivity and matrix effects variability (less than 6 %). Furthermore,short and long-term stability of the analytes in plasma was ascertained. Themethod proved to be robust in the calibrated ranges of 1 - 300 ng/mL for rivastigmineand memantine and 2 - 300 mg/mL for donepezil, galantamine and NAP226 - 90. We recently published a full description of the method (1). We found ahigh interindividual variability in plasma levels of these drugs in a study populationof 300 patients. The plasma level measurements, with some preliminaryclinical and pharmacogenetic results, will be presented. Conclusion: A simpleLC-MS method was developed for plasma level determination of antidementiadrugs which was successfully used in a clinical study with 300 patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thousands of chemical compounds enter the natural environment but many have unknown effects and consequences, in particular at low concentrations. This thesis work contributes to our understanding of pollution effects by using bacteria as test organisms. Bacteria are important for this question because some of them degrade and transform pollutants into less harmful compounds, but secondly because they themselves can be inhibited in their reproduction by exposure to toxic compounds. When inhibitory effects occur this may change the composition of the microbial com¬munity in the long run, leading to altered or diminished ecosystem services by those communities. As a result chemicals of anthropogenic origin may accumulate and per¬sist in the environment, and finally, affect higher organisms as well. In addition to acquiring basic understanding of pollutant effects at low concentrations on bacterial communities an applied goal of this thesis work was to develop bacteria-based tests to screen new organic chemicals for toxicity and biodégradation. In the first part of this work we developed a flow cytometry-based assay on SYT09 plus ethidium-bromide or propidium-iodide stained cells of Pseudomonas ûuorescens exposed or not to a variety of pollutants under oligotrophic growth conditions. Flow cytometry (FC) allows fast and accurate counting of bacterial cells under simul¬taneous assessment of their physiological state, in particular in combination with different fluorescent dyes. Here we employed FC and fluorescent dyes to monitor the effect that pollutants may exert on Pseudomonas ûuorescens SV3. First we designed an oligotrophic growth test, which enabled us to follow population growth at low densities (104 - 10 7 cells per ml) using 0.1 mM sodium acetate as carbon source. Cells in the oligotrophic milieu were then exposed or not to a variety of common pollutants, such as 2-chlorobiphenyl (2CBP), naphthalene (NAH), 4-chlorophenol (4CP), tetradecane (TD), mercury chloride (HgCl2) or benzene, in different dosages. Exposed culture samples were stained with SYT09 (green fluorescent dye binding nucleic acids, generally staining all cells) in combination with propidium iodide (PI) or ethidium bromide (EB), both dyes being membrane integrity indicators. We ob- served that most of the tested compounds decreased population growth in a dosage- dependent manner. SYT09/PI or SYT09/EB staining then revealed that chemical exposure led to arisal of subpopulations of live and injured or dead cells. By modeling population growth on the total cell numbers in population or only the subpopulation of live cells we inferred that even in stressed populations live cells multiply at rates no different to unexposed controls. The net decrease in population growth would thus be a consequence of more and more cells being not able to multiply at all, rather than all cells multiplying at slower rates. In addition, the proportion of injured cells correlated to the compound dosage. We concluded that the oligotrophic test may be useful to asses toxicity of unknown chemicals on a variety of model bacteria. Mul¬tiple tests can be run in parallel and effects are rapidly measured within a period of 8 hours. Interestingly, in the same exposure tests with P. fluorescens SV3 we observed that some chemicals which did not lead to a reduction of net population growth rates did cause measurable effects on live cells. This was mainly observed in cells within the live subpopulation as an increase of the EB fluorescence signal. We showed that SYT09/EB is a more useful combination of dyes than SYT09/PI because PI fluorescence tend to increase only when cells are effectively dead, but not so much in live cells (less then twofold). In contrast, EB geometric mean fluorescence in live cells increased up to eightfold after exposure to toxic compounds. All compounds even at the lowest concentration caused a measurable increase in EB geometric mean fluorescence especially after 2 h incubation time. This effect was found to be transient for cells exposed to 2CBP and 4CP, but chronic for cells incubated with TD and NAH (ultimately leading to cell death). In order to understand the mechanism underlying the observed effects we used known membrane or energy uncouplers. The pattern of EB signal increase in chemical-exposed populations resembled mostly that of EDTA, although EB fluorescence in EDTA-treated or pasteurized cells was even higher than after exposure to the four test chemicals. We conclude that the ability of cells to efflux EB under equilibrium conditions is an appropriate measure for the potential of a chemical to exert toxicity. Since most bacterial species possess efflux systems for EB that all require cellular energy, our test should be more widely relevant to infer toxicity effects of chemical exposure on the physiological status of the bacterial cell. To better understand the effect of toxicant exposure on efflux defense systems, we studied 2-hydroxybiphenyl toxicity to Pseudomonas azeiaica HBP1. We showed that 2-HBP exerts toxicity even to P. azelaica HBP1, but only at concentrations higher than 0.5 mM. Above this concentration transient loss of membrane polarization and integrity occurred, which we conclude from staining of growing cells with fluorescent dyes. Cells finally recover and resume growth on 2HBP. The high resistance of P. azelaica HBP1 to 2-HBP was found to be the result of an efficient MexABOprM- type efflux pump system counteracting passive influx of this compound into the membrane and cellular interior. Mutants with disrupted mexA, mexB and oprM genes did no longer grow on 2-HBP at concentrations above 100 μΜ, whereas below this concentration we found 2-HBP-concentration dependent decrease of growth rate. The MexAB-OprM system in P. azeiaica HBP1 is indeed an efflux pump for ethidium bromide as well. By introducing gfp reporter fusions responsive to intracellular 2- HBP concentrations into HBP1 wild-type or the mutants we demonstrated that 2HBP enters into the cells in a similar way. In contrast, the reporter system in the wild-type cells does not react to 2-HBP at an outside concentration of 2.4 μΜ, whereas in mutant cells it does. This suggests that wild-type cells pump 2-HBP to the outside very effectively preventing accumulation of 2-HBP. 2HBP metabolism, therefore, is not efficient enough to lower the intracellular concentration and prevent toxicity. We conclude that P. azelaica HBP1 resistance to 2-HBP is mainly due to an efficient efflux system and that 2HBP in high concentrations exerts narcotic effects on the bacterial membrane. In the part of this thesis, we investigated the possibilities of bacteria to degrade pollutants at low concentrations (1 mg per L and below). As test components we used 2-hydroxybiphenyl, antibiotics and a variety of fragrances, many of which are known to be difficult to biodegrade. By using accurate counting of low numbers of bacterial cells we could demonstrate that specific growth on these compounds is possible. We demonstrated the accuracy of FC counting at low cell numbers (down to 103 bacterial cells per ml). Then we tested whether bacterial population growth could be specifically monitored at the expense of low substrate concentrations, us¬ing P. azelaica HBP1. A perfect relationship was found between growth rate, yield and 2-HBP concentrations in the range of 0.1 up to 5 mg per L. Mixing P. azelaica within sludge, however, suggested that growth yields in a mixed community can be much lower than in pure culture, perhaps because of loss of metabolic intermediates. We then isolated new strains from activated sludge using 2-HBP or antibiotics (Nal, AMP, SMX) at low concentrations (0.1-1 mg per L) as sole carbon and energy sub¬strate and PAO microdishes. The purified strains were then examined for growth on their respective substrate, which interestingly, showed that all strains can not with¬stand higher than 1 or 10 mg per L concentrations of target substrate. Thus, bacteria must exist that contribute to compound degradation at low pollutant concentrations but are inhibited at higher concentrations. Finally we tested whether specific biomass growth (in number of cells) at the expense of pollutants can also be detected with communities as starting material. Hereto, we focused on a number of fragrance chemicals and measured community biomass increase by flow cytometry cell counting on two distinct starter communities: (i) diluted Lake Geneva water, and dilute activated sludge from a wastewater treatment plant. We observed that most of the test compounds indeed resulted in significant biomass increase in the starter community compared to a no-carbon added control, but activated sludge and lake Geneva water strongly differed (almost mutually ex¬clusive) in their capacity to degrade the test chemicals. In two cases for activated sludge the same type of microbial community developed upon compound exposure, as concluded from transcription fragment length polymorphism analysis on community purified and PCR amplified 16S rRNA gene fragments. To properly test compound biodegradability it is thus important to use starter communities of different origin. We conclude that FC counting can be a valuable tool to screen chemicals for their biodegradability and toxicity. - Des milliers de produits chimiques sont libérés dans l'environnement mais beaucoup ont des effets inconnus, en particulier à basses concentrations. Ce travail de thèse contribue à notre comprehension des effets de la pollution en utilisant des bacteries comme des organismes-tests. Les bacteries sont importantes pour etudier cette ques¬tion car certaines d'entre elles peuvent degrader ou transformer les polluants, mais également parce qu'elles-mmes peuvent tre inhibees dans leur reproduction après avoit ete exposees à ces composes toxiques. Quand des effets inhibiteurs ont lieu, la composition de la communauté microbienne peut tre changee à long terme, ce qui mène à une reduction du service d'ecosystème offert par ces communautés. En consequence, après leur liberation dans l'environnement, les produits chimiques d'origine anthropogenique peuvent soit s'y accumuler et per¬sister, exerant ainsi des effets encore inconnus sur les organismes vivants. En plus d'acquérir des connaissances de base sur les effets des polluants à basses concentra¬tions sur les communautés microbiennes, un but applique de cette thèse était de développer des tests bases sur les bacteries afin d'identifier de nouveau composes pour leur toxicité ou leur biodégradation. Dans la première partie de ce travail, nous avons developpe un test base sur la cytometrie de flux (FC) sur des cellules de Pseudomonas fluorescens colorees par du bromure d'ethidium ou de l'iodure de propidium et exposees ou non à une palette de polluants sous des conditions de croissance oligotrophique. La cytometrie de flux est une technique qui connaît de nombreuses applications dans la microbiologie environ¬nementale. Cela est principalement du au fait qu'elle permet un comptage rapide et precis ainsi que l'évaluation de l'état physiologique, en particulier lorsqu'elle est combinée h des colorations fluorescentes. Ici, nous avons utilise la technique FC et des colorants fluorescents afin de mesurer l'effet que peuvent exercer certains pollu¬ants sur Pseudomonas ûuorescens SV3 . D'abord nous avons conu des tests oligo- trophiques qui nous permettent de suivre la croissance complète de cellules en culture h des densites faibles (104 -10 7 cellules par ml), sur de l'acetate de sodium à 0.1 mM, en presence ou absence de produits chimiques (2-chlorobiphenyl (2CBP), naphthalène (NAH), 4-chlorophenol (4CP), tetradecane (TD), chlorure de mercure(II) (HgCl2)) à différentes concentrations. Afin de montrer le devenir des bacteries tant au niveau de la cellule individuelle que celui de la population globale, après exposition à des series de composes chimiques, nous avons compte les cellules colorees avec du SYT09 (col¬orant fluorescent vert des acides nucléiques pour la discrimination des cellules par rapport au bruit de fond) en combinaison avec l'iodure de propidium (PI) ou le bromure d'ethidium (EB), indicateurs de l'intégrité de la membrane cellulaire avec FC. Nous avons observe que de nombreux composes testes avaient un effet sur la croissance bacterienne, resultant en une baisse du taux de reproduction de la pop¬ulation. En outre, la double coloration que nous avons utilisee dans cette etude SYT09/PI ou SYT09/EB a montre que les produits chimiques testes induisaient une reponse heterogène des cellules dans la population, divisant celle-ci en sous- populations "saine", "endommagee" ou "morte". Les nombres de cellules à partir du comptage et de la proportion de celles "saines" et "endommagees/mortes" ont ensuite ete utilises pour modeliser la croissance de P. ûuorescens SV3 exposee aux produits chimiques. La reduction nette dans la croissance de population est une consequence du fait que de plus en plus de cellules sont incapables de se reproduire, plutt que du fait d'une croissance plus lente de l'ensemble de la population. De plus, la proportion de cellules endommagees est correllee au dosage du compose chimique. Les résultats obtenus nous ont permis de conclure que le test oligotrophique que nous avons developpe peut tre utilise pour l'évaluation de la toxicité de produits chimiques sur différents modèles bacteriens. Des tests multiples peuvent tre lances en parallèle et les effets sont mesures en l'espace de huit heures. Par ailleurs, nous en déduisons que les produits chimiques exercént un effet sur la croissance des cellules de P. ûuorescens SV3, qui est heterogène parmi les cellules dans la population et depend du produit chimique. Il est intéressant de noter que dans les mmes tests d'exposition avec P. ûuorescens SV3, nous avons observe que certains composes qui n'ont pas conduit à une reduction du taux de la croissance nette de la population, ont cause des effets mesurables sur les cellule saines. Ceci a ete essentiellement observe dans la portion "saine" des cellules en tant qu'augmentation du signal de la fluorescence de 1ΈΒ. D'abord nous avons montre que SYT09/EB était une com¬binaison de colorants plus utile que celle de SYT09/PI parce que la fluorescence du PI a tendance à augmenter uniquement lorsque les cellules sont effectivement mortes, et non pas dans les cellules saines (moins de deux fois plus). Par opposi¬tion, la fluorescence moyenne de l'EB dans les cellules saines augmente jusqu'à huit fois plus après exposition aux composes toxiques. Tous les composes, mme aux plus basses concentrations, induisent une augmentation mesurable de la fluorescence moy¬enne de 1ΈΒ, plus particulièrement après deux heures d'incubation. Cet effet s'est revele tre transitoire pour les cellules exposees aux 2CNP et 4CP, mais est chro¬nique pour les cellules incubees avec le TD et le NAH (entranant la mort cellulaire). Afin de comprendre les mécanismes qui sous-tendent les effets observes, nous avons utilise des decoupleurs d'energie ou de membrane. L'augmentation du signal EB dans les populations causee par des produits chimiques ressemblait à celle exerce par le chelateur des ions divalents EDTA. Cependant, les intensités du signal EB des cellules exposees aux produits chimiques testees n'ont jamais atteint les valeurs des cellules traitees avec l'EDTA ou pasteurises. Nous en concluons que le test oli- gotrophique utilisant la coloration (SYT09/)EB des cellules exposees ou non à un produit chimique est utile afin d'evaluer l'effet toxique exerce par les polluants sur la physiologie bacterienne. Afin de mieux comprendre la reaction d'un système de defense par pompe à efflux après exposition à une toxine, nous avons étudié la toxicité du 2-hydroxybiphenyl (2-HBP) sur Pseudomonas azeiaica HBP1. Nous avons montre que le 2-HBP exerce une toxicité mme sur HBP1, mais uniquement à des concentrations supérieures à 0.5 mM. Au-dessus de cette concentration, des pertes transitoires d'intégrité et de polarization membranaire ont lieu, comme cela nous a ete montre par coloration des cellules en croissance. Les cellules sont finalement capables de se rétablir et de reprendre leur croissance sur 2-HBP. La forte resistance de P. azeiaica HBP1 h 2-HBP physiologie bacterienne s'est revele tre le résultat d'un système de pompe h efflux de type MexABOprM qui contre-balance l'influx passif de ce compose h travers la membrane. Nous avons montre, en construisant des mutants avec des insertions dans les gènes mexA, mexB and oprM et des fusions avec le gène rapporteur gfp, que l'altération de n'importe quelle partie du système d'efflux conduisait à accroître l'accumulation de 2-HBP dans la cellule, en comparaison avec la souche sauvage HBP1, provoquant une diminution de la resistance au 2-HBP ainsi qu'une baisse du taux de reproduction des cellules. Des systèmes d'efflux similaires sont répandus chez de nombreuses espèces bactériennes. Ils seraient responsables de la resistance aux produits chimiques tels que les colorants fluorescents (bromure d'ethidium) et des antibiotiques. Nous concluons que la resistance de P. azelaica HBP1 à 2-HBP est principalement due à un système d'efflux efficace et que 2-HBP, à des concentrations elevees, exerce un effet deletère sur la membrane bacterienne. En se basant sur le comptage des cellules avec la FC, nous avons developpe ensuite une methode pour evaluer la biodegradabilite de polluants tels que le 2-HBP ainsi que les antibiotiques (acide nalidixique (Nal), ampicilline (AMP) ou sulfamethoxazole (SMX)) à de faibles concentrations lmg par L et moins), par le suivi de la croissance spécifique sur le compose de cultures microbiennes pures et mixtes. En utilisant un comptage precis de faibles quantités de cellules nous avons pu demontrer que la croissance spécifique sur ces composes est possible. Nous avons pu illustrer la precision du comptage par cytometrie de flux à faible quantité de cellules (jusqu'à 10 3 cellules par ml). Ensuite, nous avons teste s'il était possible de suivre dynamiquement la croissance de la population de cellules sur faibles concentrations de substrats, en utilisant P. azelaica HBP1. Une relation parfaite a ete trouvee entre le taux de croissance, le rendement et les concentrations de 2-HBP (entre 0.1 et 5 mg par L). En mélangeant HBP1 à de la boue active, nous avons pu montrer que le rendement en communauté mixtes pouvait tre bien inférieur qu'en culture pure. Ceci étant peut tre le résultat d'une perte d'intermédiaires métaboliques. Nous avons ensuite isole de nouvelles souches à partir de la boue active en utilisant le 2-HBP ou des antibiotiques (Nal, AMP, SMX) h basses concentrations (0.1-1 mg par L) comme seules sources de carbone et d'energie. En combinaison avec ceci, nous avons également utilise des microplaques PAO. Les souches purifiees ont ensuite ete examinees pour leurs croissances sur leurs substrats respectifs. De faon intéressante, toutes ces souches ont montre qu'elles ne pouvaient pas survivre à des concentrations de substrats supérieures à 1 ou 10 mg par L. Ainsi, il existe des bacteries qui contribuent à la degradation de composes à basses concentrations de polluant mais sont inhibes lorsque ces concentrations deviennent plus hautes. Finalement, nous avons cherche à savoir s'il est possible de detecter une croissance spécifique à une biomasse au depend d'un polluant, en partant d'une communauté microbienne. Ainsi, nous nous sommes concentre sur certains composes et avons mesure l'augmentation de la biomasse d'une communauté grce à la cytometrie de flux. Nous avons compte deux communautés de depart distinctes: (i) une dilution d'eau du Lac Léman, et une dilution de boue active d'une station d'épuration. Nous avons observe que la plupart des composes testes ont entrane une augmentation de la biomasse de depart par rapport au control sans addition de source de carbone. Néanmoins, les échantillons du lac Léman et de la station d'épuration différaient largement (s'excluant mutuellement l'un l'autre) dans leur capacité à degrader les composes chimiques. Dans deux cas provenant de la station d'épuration, le mme type de communauté microbienne s'est developpe après exposition aux composes, comme l'a démontré l'analyse TRFLP sur les fragments d'ARN 16S purifie de la communauté et amplifie par PCR. Afin de tester correctement la biodegradabilite d'un compose, il est donc important d'utiliser des communautés de depart de différentes origines Nous en concluons que le comptage par cytometrie de flux peut tre un outil de grande utilité pour mettre en valeur la biodegradabillite et la toxicité des composes chimiques.