49 resultados para Six-min walk test

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To evaluate outcome of patients treated "off-label" by bosentan and/or sildenafil for chronic thromboembolic pulmonary hypertension (CTEPH). Patients and methods: Since 2003, 18 patients (mean age 69 ± 11 years) have been treated with bosentan and/or sildenafil for CTEPH (mean pulmonary arterial resistance 8.1 ± 3.7 U Wood) in Lausanne University Hospital, with a follow-up of at least 12 months. Sixteen of them were inoperable because of distal disease and/or age or significant co-morbidities and 2 had persistent or recurrent pulmonary hypertension despite surgery. Efficacy of treatment was evaluated by comparison of New York Heart Association functional class (NYHA), six-minute walk test (6-MWT) and serum levels of N-terminal-pro brain natriuretic peptide (NT pro-BNP) at baseline (T0) and at 12 months (T12). Wilcoxon rank test was used for statistics. Results: At T0, median NYHA class was III (range II-IV), 6-MWT was 348 meters (5 and 95 centiles:0, 539) and NT pro-BNP was 387 mmol/l (58, 3508). At T12, 11 patients were treated with bosentan, 5 with sildenafil, 1 with inhaled Iloprost (because of failure of the two other treatments) and 1 with a combination of sildenafil and Iloprost. NYHA had improved in 10 patients, remained stable in 7 and worsened in 1 (median decrease 0.5 (-2; 0.2) p = 0.013). Six-MWT improved by a median of 15 meters (-142, +270) (p = 0.047) and NT pro-BNP decreased by a median of 65 mmol/l (-2988, +187) (p = n.s.). Among the 10 patients with a follow-up of 2 years or longer, two thirds remained stable and one third had worsened at 24 month. Treatments were well tolerated and only one patient had significant side effects (cutaneous reaction to bosentan) necessitating a switch to another treatment. Conclusion: In agreement with published data, bosentan and sildenafil improved functional status (NYHA, 6-MWT) and haemodynamics (NT pro BNP) in our patients with inoperable CTEPH. However these medications should not be used as substitute for surgery when the latter is applicable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background During gait, the hip flexors generate 40% of the total power. Nevertheless, no device has been tested extensively for clinical purposes to cope with weakness in the hip flexors in patients with stroke. Objective The purpose of this study was to assess the efficacy and safety of a newly developed hip flexion assist orthosis in adult patients with hemiparesis after stroke. Design The study used a prospective, randomized, before-after trial design. The inclusion criteria were hemiparesis resulting from stroke (onset ≥8 weeks); ability to walk, even if with assistance; and hip flexion weakness (Medical Research Council Scale score ≤4).¦METHODS: /b> The main outcome measures were the 10-Meter Walk Test and the Six-Minute Walk Test. Patients also were evaluated with the Trunk Control Test, the Functional Ambulation Categories, the Motricity Index, and hip flexor strength on the Medical Research Council Scale. Sixty-two survivors of stroke were tested in random order with and without the orthosis. Any adverse event associated with its use was recorded.¦RESULTS: /b> Both the Six-Minute Walk Test and the 10-Meter Walk Test scores improved with the use of the orthosis. A significant negative correlation was found for improvement between scores on the 2 main outcome measures with the orthosis and the Functional Ambulation Categories scores. The improvement in Six-Minute Walk Test scores with the orthosis was related inversely to hip flexor strength.¦CONCLUSIONS: /b> The data showed that the use of a hip flexion assist orthosis can improve gait in patients with poststroke hemiparesis, particularly those with more severe walking impairment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Master athletes are often considered to represent the ideal rate of decline of aerobic function; however, most of the studies interested in active elderly people are often limited to people younger than 75. We aimed to determine the physiological adaptations and aerobic fitness in a selected European population of active octogenarians during maximal and submaximal exercise tests. Aerobic capacity was measured during maximal incremental tests on treadmill (TR) and cycle-ergometer (CE) and functional capacity during a 6-minute walk test (6-MWT) in 17 subjects aged 81.2 +/- 0.8 years. Pulmonary gas exchange and heart rate (HR) were continuously measured during the different exercise tests. Maximal oxygen consumption (V.O (2max)) on TR and CE was significantly higher than predicted values (TR: 28.7 +/- 1.2 vs. 17 +/- 0.5 ml . kg (-1) . min (-1); CE: 23 +/- 1.2 vs. 16 +/- 0.6 ml . kg (-1) . min (-1) for measured and predicted values respectively). V.O (2max) and HR (max), as well as V.O (2) and HR at the ventilatory threshold (V.O (2)T (V.E) and HR T (V.E)) were significantly higher on TR than on CE (HR (max): 144 +/- 4 vs. 138 +/- 4 bpm; V.O (2)T (V.E): 22.5 +/- 0.8 vs. 17.7 +/- 0.9 ml . kg (-1) . min (-1) for TR and CE respectively). V.O (2)T (V.E) and HR T (V.E) on TR were equivalent to V.O (2) and HR measured during the 6-MWT. HR T (V.E) on TR and mean HR during the 6-MWT were strongly correlated (R = 0.82, p < 0.01). Maintenance of regular physical activity provides high aerobic fitness, in octogenarians, as was shown by the higher values of our subjects in comparison to predicted values. Moreover, the close relation between the intensity developed at T (V.E) on TR and 6-MWT could support the idea that a walk test is a submaximal test performed at high intensity that could provide a basis for exercise prescription in an individualized manner in active elderly people.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To compare the effect of hyperthermia on maximal oxygen uptake (VO2max) in men and women, VO2max was measured in 11 male and 11 female runners under seven conditions involving various ambient temperatures (Ta at 50% RH) and preheating designed to manipulate the esophageal (Tes) and mean skin (Tsk) temperatures at VO2max. The conditions were: 25 degrees C, no preheating (control); 25, 35, 40, and 45 degrees C, with exercise-induced preheating by a 20-min walk at approximately 33% of control VO2max; 45 degrees C, no preheating; and 45 degrees C, with passive preheating during which Tes and Tsk were increased to the same degree as at the end of the 20-min walk at 45 degrees C. Compared to VO2max (l x min(-1)) in the control condition (4.52+/-0.46 in men, 3.01+/-0.45 in women), VO2max in men and women was reduced with exercise-induced or passive preheating and increased Ta, approximately 4% at 35 degrees C, approximately 9% at 40 degrees C and approximately 18% at 45 degrees C. Percentage reductions (7-36%) in physical performance (treadmill test time to exhaustion) were strongly related to reductions in VO2max (r=0.82-0.84). The effects of hyperthermia on VO2max and physical performance in men and women were almost identical. We conclude that men and women do not differ in their thermal responses to maximal exercise, or in the relationship of hyperthermia to reductions in VO2max and physical performance at high temperature. Data are reported as mean (SD) unless otherwise stated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8cm for stride length, 1.4±5.6cm/s for stride velocity, 1.9±2.0cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Outcome after lung transplantation (LTx) is affected by the onset of bronchiolitis obliterans syndrome (BOS) and lung function decline. Reduced health-related quality of life (HRQL) and physical mobility have been shown in patients developing BOS, but the impact on the capacity to walk is unknown. We aimed to compare the long-term HRQL and 6-minute walk test (6MWT) between lung recipients affected or not by BOS Grade > or =2. METHODS: Fifty-eight patients were prospectively followed for 5.6 +/- 2.9 years after LTx. Assessments included the St George's Respiratory Questionnaire (SGRQ) and the 6MWT, which were performed yearly. Moreover, clinical complications were recorded to estimate the proportion of the follow-up time lived without clinical intercurrences after transplant. Analyses were performed using adjusted linear regression and repeated-measures analysis of variance. RESULTS: BOS was a significant predictor of lower SGRQ scores (p < 0.01) and reduced time free of clinical complications (p = 0.001), but not of 6MWT distance (p = 0.12). At 7 years post-transplant, results were: 69.0 +/- 21.8% vs 86.9 +/- 5.6%, p < 0.05 (SGRQ); 58.5 +/- 21.6% vs 88.7 +/- 11.4%, p < 0.01 (proportion of time lived without clinical complications); and 82.2 +/- 10.9% vs 91.9 +/- 14.2%, p = 0.27 (percent of predicted 6MWT), respectively, for patients with BOS and without BOS. CONCLUSIONS: Despite significantly less time lived without clinical complications and progressive decline of self-reported health status, the capacity to walk of patients affected by BOS remained relatively stable over time. These findings may indicate that the development of moderate to severe BOS does not prevent lung recipients from walking independently and pursuing an autonomous life.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Registries are important for real-life epidemiology on different pulmonary hypertension (PH) groups. OBJECTIVE: To provide long-term data of the Swiss PH registry of 1998-2012. METHODS: PH patients have been classified into 5 groups and registered upon written informed consent at 5 university and 8 associated hospitals since 1998. New York Heart Association (NYHA) class, 6-min walk distance, hemodynamics and therapy were registered at baseline. Patients were regularly followed, and therapy and events (death, transplantation, endarterectomy or loss to follow-up) registered. The data were stratified according to the time of diagnosis into prevalent before 2000 and incident during 2000-2004, 2005-2008 and 2009-2012. RESULTS: From 996 (53% female) PH patients, 549 had pulmonary arterial hypertension (PAH), 36 PH due to left heart disease, 127 due to lung disease, 249 to chronic thromboembolic PH (CTEPH) and 35 to miscellaneous PH. Age and BMI significantly increased over time, whereas hemodynamic severity decreased. Overall, event-free survival was 84, 72, 64 and 58% for the years 1-4 and similar for time periods since 2000, but better during the more recent periods for PAH and CTEPH. Of all PAH cases, 89% had target medical therapy and 43% combination therapy. Of CTEPH patients, 14 and 2% underwent pulmonary endarterectomy or transplantation, respectively; 87% were treated with PAH target therapy. CONCLUSION: Since 2000, the incident Swiss PH patients registered were older, hemodynamically better and mostly treated with PAH target therapies. Survival has been better for PAH and CTEPH diagnosed since 2008 compared with earlier diagnosis or other classifications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The use of robots for gait training in Parkinson disease (PD) is growing, but no evidence points to an advantage over the standard treadmill. METHODS: In this randomized, single-blind controlled trial, participants aged <75 years with early-stage PD (Hoehn-Yahr <3) were randomly allocated to 2 groups: either 30 minutes of gait training on a treadmill or in the Lokomat for 3 d/wk for 4 weeks. Patients were evaluated by a physical therapist blinded to allocation before and at the end of treatment and then at the 3- and 6-month follow-up. The primary outcome measure was the 6-minute walk test. RESULTS: Of 334 screened patients, the authors randomly allocated 30 to receive gait training with treadmill or the Lokomat. At baseline, the 2 groups did not differ. At the 6-month follow-up, both groups had improved significantly in the primary outcome measure (treadmill: mean = 490.95 m, 95% confidence interval [CI] = 448.56-533.34, P = .0006; Lokomat: 458.6 m, 95% CI = 417.23-499.96, P = .01), but no significant differences were found between the 2 groups (P = .53). DISCUSSION: Robotic gait training with the Lokomat is not superior to treadmill training in improving gait performance in patients with PD. Both approaches are safe, with results maintained for up to 6 months.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study compares the effects of two short multiple-sprint exercise (MSE) (6 × 6 s) sessions with two different recovery durations (30 s or 180 s) on the slow component of oxygen uptake ([Formula: see text]O(2)) during subsequent high-intensity exercise. Ten male subjects performed a 6-min cycling test at 50% of the difference between the gas exchange threshold and [Formula: see text]O(2peak) (Δ50). Then, the subjects performed two MSEs of 6 × 6 s separated by two intersprint recoveries of 30 s (MSE(30)) and 180 s (MSE(180)), followed 10 min later by the Δ50 (Δ50(30) and Δ50(180), respectively). Electromyography (EMG) activities of the vastus medialis and lateralis were measured throughout each exercise bout. During MSE(30), muscle activity (root mean square) increased significantly (p ≤ 0.04), with a significant leftward-shifted median frequency of the power density spectrum (MDF; p ≤ 0.01), whereas MDF was significantly rightward-shifted during MSE(180) (p = 0.02). The mean [Formula: see text]O(2) value was significantly higher in MSE(30) than in MSE(180) (p < 0.001). During Δ50(30), [Formula: see text]O(2) and the deoxygenated hemoglobin ([HHb]) slow components were significantly reduced (-27%, p = 0.02, and -34%, p = 0.003, respectively) compared with Δ50. There were no significant modifications of the [Formula: see text]O(2) slow component in Δ50(180) compared with Δ50 (p = 0.32). The neuromuscular and metabolic adaptations during MSE(30) (preferential activation of type I muscle fibers evidenced by decreased MDF and a greater aerobic metabolism contribution to the required energy demands), but not during MSE(180), may lead to reduced [Formula: see text]O(2) and [HHb] slow components, suggesting an alteration in motor units recruitment profile (i.e., change in the type of muscle fibers recruited) and (or) an improved muscle O(2) delivery during subsequent exercise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Our institution (University hospital) is encouraging physical activities for health through various popular sporting events in the city of Lausanne, the biggest of which is a road race of 2, 4, 10 and 20km. Objective To create an efficient and sustainable training program in preparation of the race for a group of motivated hospital employees without any prior experience with structured training and to identifying the benefits and limitations encountered.. Methods Subjects of various fitness levels were recruited by add and agreed to undergo lab and field testing before a 12-week 3 times/week running program, based on maximal aerobic speed (MAS-30/30 sec intervals), running technique exercises and endurance training. The interval session was the only one supervised. Their goal was the 10km (11 subjects) and the 20km (6 subjects). Results A group of 17 subjects (7 male and 10 female), mean age 36.6±7.3 years, VO2max 44.0±5.5 ml/kg/min, filed test interval MAS 15.1±2.4 km/h started the program. 2 were lost because of injury (while skiing). Adherence to interval sessions was excellent, although 3 weekly training sessions proved to be difficult for most of the subjects. Performance in the race was satisfying for all of them, 6/7 subjects having improved their running time from the previous year, the others participated for the first time and 7/8 completed the race satisfyingly, one DNF-ed because of sinusitis. Repeat MAS field test was available for 6 subjects, who improved by 5.9% (p<0.01). Subjectively, all of the participants were very satisfied with improvement, interaction with colleagues from various professions, and with self achievement and confidence. Conclusions Implementation of a structured training program for recreational or non-athletes can be very successful in creating a better self-confidence, a better working environment inside a hospital facility and obviously in improvement of physical fitness and athletic performance. Above all, it can only encourage health institutions to promote the health of their own employees through physical activity, which can allow people to connect through sports. As a result, subjects in this study tend to encourage other employees to be more active and are hungry for more advice and continued offers for physical activities benefiting both them and the institution through better efficiency at work and less absenteeism common to more active people.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Lab tests are frequently used in primary care to guide patient care. This is particularly the case when a severe disorder, or one that will affect patients' initial care, needs to be excluded rapidly. At the PMU-FLON walk-in clinic the use of HIV testing as recommended by the Swiss Office of Public Health was hampered by the delay in obtaining test results. This led us to introduce rapid HIV testing which provides results within 30 minutes. Following the first 250 tests the authors discuss the results as well as the benefits of rapid HIV testing in an urban walk-in clinic.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of the present study was to submit the same materials that were tested in the round robin wear test of 2002/2003 to the Alabama wear method. METHODS: Nine restorative materials, seven composites (belleGlass, Chromasit, Estenia, Heliomolar, SureFil, Targis, Tetric Ceram) an amalgam (Amalcap) and a ceramic (IPS Empress) have been submitted to the Alabama wear method for localized and generalized wear. The test centre did not know which brand they were testing. Both volumetric and vertical loss had been determined with an optical sensor. After completion of the wear test, the raw data were sent to IVOCLAR for further analysis. The statistical analysis of the data included logarithmic transformation of the data, the calculation of relative ranks of each material within each test centre, measures of agreement between methods, the discrimination power and coefficient of variation of each method as well as measures of the consistency and global performance for each material. RESULTS: Relative ranks of the materials varied tremendously between the test centres. When all materials were taken into account and the test methods compared with each other, only ACTA agreed reasonably well with two other methods, i.e. OHSU and ZURICH. On the other hand, MUNICH did not agree with the other methods at all. The ZURICH method showed the lowest discrimination power, ACTA, IVOCLAR and ALABAMA localized the highest. Material-wise, the best global performance was achieved by the leucite reinforced ceramic material Empress, which was clearly ahead of belleGlass, SureFil and Estenia. In contrast, Heliomolar, Tetric Ceram and especially Chromasit demonstrated a poor global performance. The best consistency was achieved by SureFil, Tetric Ceram and Chromasit, whereas the consistency of Amalcap and Heliomolar was poor. When comparing the laboratory data with clinical data, a significant agreement was found for the IVOCLAR and ALABAMA generalized wear method. SIGNIFICANCE: As the different wear simulator settings measure different wear mechanisms, it seems reasonable to combine at least two different wear settings to assess the wear resistance of a new material.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Major liver resection can be used in the treatment of liver cancer. The functional capacity of liver parenchyma needs to be evaluated preoperatively because it conditions the outcome. We assessed whether the whole body clearance of glycerol, a substrate essentially metabolized in liver cells, may be suitable as a simple test of liver function. Seven patients after major hepatectomy, six patients after colectomy and 12 healthy subjects were studied. Patients were investigated on the first day after surgery. All participants were studied during a 150-min basal period followed by a 120-min infusion of 16 mumol kg-1 min-1 13C-labelled glycerol. Whole body glycerol clearance was calculated from the change in plasma glycerol concentration. Whole body glucose production was measured with 6,6 2H2 glucose infused as a tracer in the basal state and during glycerol infusion. In addition, 13C glucose synthesis was monitored to quantitate gluconeogenesis from glycerol. Patients after liver resection had higher plasma glycerol concentrations and lower whole body glycerol clearance than healthy subjects and patients after colectomy. They also had higher plasma glucagon concentrations. Their fasting glucose production was mildly elevated in the fasting state and did not change after glycerol infusion, indicating a normal hepatic autoregulation of glucose production. These results indicate that whole body glycerol clearance can be simply determined from plasma glycerol concentrations during exogenous glycerol infusion. It is significantly reduced in patients after major hepatectomy, suggesting that it constitutes a sensitive test of hepatic function. Its use as a preoperative testing procedure remains to be evaluated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Intravoxel incoherent motion (IVIM) MRI is a method to extract microvascular blood flow information out of diffusion-weighted images acquired at multiple b-values. We hypothesized that IVIM can identify the muscles selectively involved in a specific task, by measuring changes in activity-induced local muscular perfusion after exercise. We tested this hypothesis using a widely used clinical maneuver, the lift-off test, which is known to assess specifically the subscapularis muscle functional integrity. Twelve shoulders from six healthy male volunteers were imaged at 3 T, at rest, as well as after a lift-off test hold against resistance for 30 s, 1 and 2 min respectively, in three independent sessions. IVIM parameters, consisting of perfusion fraction (f), diffusion coefficient (D), pseudo-diffusion coefficient D* and blood flow-related fD*, were estimated within outlined muscles of the rotator cuff and the deltoid bundles. The mean values at rest and after the lift-off tests were compared in each muscle using a one-way ANOVA. A statistically significant increase in fD* was measured in the subscapularis, after a lift-off test of any duration, as well as in D. A fD* increase was the most marked (30 s, +103%; 1 min, +130%; 2 min, +156%) and was gradual with the duration of the test (in 10(-3) mm(2) /s: rest, 1.41 ± 0.50; 30 s, 2.86 ± 1.17; 1 min, 3.23 ± 1.22; 2 min, 3.60 ± 1.21). A significant increase in fD* and D was also visible in the posterior bundle of the deltoid. No significant change was consistently visible in the other investigated muscles of the rotator cuff and the other bundles of the deltoid. In conclusion, IVIM fD* allows the demonstration of a task-related microvascular perfusion increase after a specific task and suggests a direct relationship between microvascular perfusion and the duration of the effort. It is a promising method to investigate non-invasively skeletal muscle physiology and clinical perfusion-related muscular disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: We examined the correlation between clinical wear rates of restorative materials and enamel (TRAC Research Foundation, Provo, USA) and the results of six laboratory test methods (ACTA, Alabama (generalized, localized), Ivoclar (vertical, volumetric), Munich, OHSU (abrasion, attrition), Zurich). METHODS: Individual clinical wear data were available from clinical trials that were conducted by TRAC Research Foundation (formerly CRA) together with general practitioners. For each of the n=28 materials (21 composite resins for intra-coronal restorations [20 direct and 1 indirect], 5 resin materials for crowns, 1 amalgam, enamel) a minimum of 30 restorations had been placed in posterior teeth, mainly molars. The recall intervals were up to 5 years with the majority of materials (n=27) being monitored, however, only for up to 2 years. For the laboratory data, the databases MEDLINE and IADR abstracts were searched for wear data on materials which were also clinically tested by TRAC Research Foundation. Only those data for which the same test parameters (e.g. number of cycles, loading force, type of antagonist) had been published were included in the study. A different quantity of data was available for each laboratory method: Ivoclar (n=22), Zurich (n=20), Alabama (n=17), OHSU and ACTA (n=12), Munich (n=7). The clinical results were summed up in an index and a linear mixed model was fitted to the log wear measurements including the following factors: material, time (0.5, 1, 2 and 3 years), tooth (premolar/molar) and gender (male/female) as fixed effects, and patient as random effect. Relative ranks were created for each material and method; the same was performed with the clinical results. RESULTS: The mean age of the subjects was 40 (±12) years. The materials had been mostly applied in molars (81%) and 95% of the intracoronal restorations were Class II restorations. The mean number of individual wear data per material was 25 (range 14-42). The mean coefficient of variation of clinical wear data was 53%. The only significant correlation was reached by OHSU (abrasion) with a Spearman r of 0.86 (p=0.001). Zurich, ACTA, Alabama generalized wear and Ivoclar (volume) had correlation coefficients between 0.3 and 0.4. For Zurich, Alabama generalized wear and Munich, the correlation coefficient improved if only composites for direct use were taken into consideration. The combination of different laboratory methods did not significantly improve the correlation. SIGNIFICANCE: The clinical wear of composite resins is mainly dependent on differences between patients and less on the differences between materials. Laboratory methods to test conventional resins for wear are therefore less important, especially since most of them do not reflect the clinical wear.