248 resultados para Six Sigma Technique

em Université de Lausanne, Switzerland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: During pull-through for Hirschsprung's disease (HSCR), the assessment of innervation is mainly based on the presence of ganglion cells when conventional Hematoxylin and Eosin (HE) staining is used. In hypoganglionosis, the evaluation is difficult. We adapted a standardized methodology for the examination of resected bowel after HSCR surgery, using the technique described by Moolenbeek on rodent intestine and later by Meier-Ruge in children. We have analysed the entire innervation of surgically resected bowels and compared the results with the follow up of patients. METHODS: Three longitudinal strips of colon were harvested from the mesenteric, anti-mesenteric and intermediate part in the whole length of resected colon of six patients with HSCR. Each strip was divided into two parts. One of the contiguous strips was assessed with HE and Hematoxylin-Phloxin-Safran, and the other one with acetylcholinesterase (AChE) histochemistry. We analyzed the distribution of ganglion cells and nerve arrangement along the strips with both techniques and compared the results obtained in the three different regions of the bowel. RESULTS: There was no significant difference in the pattern of innervation circumferentially. There was a correlation between a progressive increase of AChE activity and nerve hypertrophy and a decrease of ganglion cells from the proximal to the distal part of the resected colon in the submucosa and the myenteric plexus. Nerve hypertrophy and AChE-positive reaction in the mucosa were found at the resection border in patients who presented postoperative complications. CONCLUSIONS: Simultaneous assessment of nerve cells, nerve fibers and AChE activity is important in the evaluation of the innervation of the bowel segment proximal to the aganglionic zone. The method described is feasible and can be adapted to older children and adults with larger bowels. These results point out the importance of assessing nerve fibers in intraoperative biopsies during pull-through procedures to prevent uncomplete surgical bowel resection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To compare different techniques for positive contrast imaging of susceptibility markers with MRI for three-dimensional visualization. As several different techniques have been reported, the choice of the suitable method depends on its properties with regard to the amount of positive contrast and the desired background suppression, as well as other imaging constraints needed for a specific application. MATERIALS AND METHODS: Six different positive contrast techniques are investigated for their ability to image at 3 Tesla a single susceptibility marker in vitro. The white marker method (WM), susceptibility gradient mapping (SGM), inversion recovery with on-resonant water suppression (IRON), frequency selective excitation (FSX), fast low flip-angle positive contrast SSFP (FLAPS), and iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) were implemented and investigated. RESULTS: The different methods were compared with respect to the volume of positive contrast, the product of volume and signal intensity, imaging time, and the level of background suppression. Quantitative results are provided, and strengths and weaknesses of the different approaches are discussed. CONCLUSION: The appropriate choice of positive contrast imaging technique depends on the desired level of background suppression, acquisition speed, and robustness against artifacts, for which in vitro comparative data are now available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To assess inter-observer variability of renal blood oxygenation level-dependent MRI (BOLD-MRI) using a new method of analysis, called the concentric objects (CO) technique, in comparison with the classical ROI (region of interest)-based technique. METHODS: MR imaging (3T) was performed before and after furosemide in 10 chronic kidney disease (CKD) patients (mean eGFR 43±24ml/min/1.73m(2)) and 10 healthy volunteers (eGFR 101±28ml/min1.73m(2)), and R2* maps were determined on four coronal slices. In the CO-technique, R2* values were based on a semi-automatic procedure that divided each kidney in six equal layers, whereas in the ROI-technique, all circles (ROIs) were placed manually in the cortex and medulla. The mean R2*values as assessed by two independent investigators were compared. RESULTS: With the CO-technique, inter-observer variability was 0.7%-1.9% across all layers in non-CKD, versus 1.6%-3.8% in CKD. With the ROI-technique, median variability for cortical and medullary R2* values was 3.6 and 6.8% in non-CKD, versus 4.7 and 12.5% in CKD; similar results were observed after furosemide. CONCLUSION: The CO-technique offers a new, investigator-independent, highly reproducible alternative to the ROI-based technique to estimate renal tissue oxygenation in CKD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

NlmCategory="UNASSIGNED">Rapid deployment aortic valve replacement (RDAVR) with the use of rapid deployment valve systems represents a smart alternative to the use of standard aortic bioprosthesis for aortic valve replacement. Nevertheless, its use is still debatable in patients with pure aortic valve regurgitation or true bicuspid aortic valve because of the risk of postoperative paravalvular leak. To address this issue, an optimal annulus-valve size match seems to be the ideal surgical strategy. This article describes a new technique developed to stabilize the aortic annulus and prevent paravalvular leak after RDAVR. To confirm the feasibility, this technique was performed in six patients with severe symptomatic aortic stenosis who were scheduled to undergo aortic valve replacement at our center. All patients survived surgery and were discharged from the hospital. There were no new intracardiac conduction system disturbances observed, and a permanent pacemaker implantation was not required in any of the patients. The intraoperative and postoperative echocardiogram confirmed successful positioning of the valve, and no paravalvular leak was observed. In this preliminary experience, RDAVR through a full sternotomy or an upper hemisternotomy approach with the use of aortic annulus stabilization technique was safe, and no leak was observed. Future studies on large series of patients are necessary to confirm the safety and effectiveness of this technique in preventing paravalvular leak in patients with true bicuspid aortic valves or pure aortic regurgitation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Abdominoperineal resection (APR) following radiotherapy is associated with a high rate of perineal wound complications. The anterolateral thigh (ALT) flap, combined with the vastus lateralis (VL) muscle, can cover complex perineal and pelvic anteroposterior defects. This is used for the first time transabdominally through the pelvis and the perineum (TAPP) in the infero-posterior directions; this technique has been described and illustrated in this study. METHODS: Among over 90 patients who underwent perineal reconstruction between May 2004 and June 2011, six patients presented high-grade tumours invading perineum, pelvis and sacrum, thereby resulting in a continuous anteroposterior defect. ALT + VL TAPP reconstructions were performed after extended APR and, subsequently, sacrectomy. Patients were examined retrospectively to determine demographics, operative time, complications (general and flap-related), time to complete healing and length of hospital stay. Long-term flap coverage, flap volume stability and functional and aesthetic outcomes were assessed. RESULTS: Mean operating time of the reconstruction was 290 min. No deaths occurred. One patient presented partial flap necrosis. Another patient presented a novel wound dehiscence after flap healing, due to secondary skin dissemination of the primary tumour. Following volumetric flap analysis on serial post-operative CT scans, no significant flap atrophy was observed. All flaps fully covered the defects. No late complications such as fistulas or perineal hernias occurred. Donor-site recovery was uneventful with no functional deficits. CONCLUSIONS: The use of the ALT + VL flap transabdominally is an innovative method to reconstruct exceptionally complex perineal and pelvic defects extending up to the lower back. This flap guarantees superior bulk, obliterating all pelvic dead space, with the fascia lata (FL) supporting the pelvic floor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La douleur est fréquente en milieu de soins intensifs et sa gestion est l'une des missions des infirmières. Son évaluation est une prémisse indispensable à son soulagement. Cependant lorsque le patient est incapable de signaler sa douleur, les infirmières doivent se baser sur des signes externes pour l'évaluer. Les guides de bonne pratique recommandent chez les personnes non communicantes l'usage d'un instrument validé pour la population donnée et basé sur l'observation des comportements. A l'heure actuelle, les instruments d'évaluation de la douleur disponibles ne sont que partiellement adaptés aux personnes cérébrolésées dans la mesure où ces personnes présentent des comportements qui leur sont spécifiques. C'est pourquoi, cette étude vise à identifier, décrire et valider des indicateurs, et des descripteurs, de la douleur chez les personnes cérébrolésées. Un devis d'étude mixte multiphase avec une dominante quantitative a été choisi pour cette étude. Une première phase consistait à identifier des indicateurs et des descripteurs de la douleur chez les personnes cérébrolésées non communicantes aux soins intensifs en combinant trois sources de données : une revue intégrative des écrits, une démarche consultative utilisant la technique du groupe nominal auprès de 18 cliniciens expérimentés (6 médecins et 12 infirmières) et les résultats d'une étude pilote observationnelle réalisée auprès de 10 traumatisés crâniens. Les résultats ont permis d'identifier 6 indicateurs et 47 descripteurs comportementaux, vocaux et physiologiques susceptibles d'être inclus dans un instrument d'évaluation de la douleur destiné aux personnes cérébrolésées non- communicantes aux soins intensifs. Une deuxième phase séquentielle vérifiait les propriétés psychométriques des indicateurs et des descripteurs préalablement identifiés. La validation de contenu a été testée auprès de 10 experts cliniques et 4 experts scientifiques à l'aide d'un questionnaire structuré qui cherchait à évaluer la pertinence et la clarté/compréhensibilité de chaque descripteur. Cette démarche a permis de sélectionner 33 des 47 descripteurs et valider 6 indicateurs. Dans un deuxième temps, les propriétés psychométriques de ces indicateurs et descripteurs ont été étudiés au repos, lors de stimulation non nociceptive et lors d'une stimulation nociceptive (la latéralisation du patient) auprès de 116 personnes cérébrolésées aux soins intensifs hospitalisées dans deux centres hospitaliers universitaires. Les résultats montrent d'importantes variations dans les descripteurs observés lors de stimulation nociceptive probablement dues à l'hétérogénéité des patients au niveau de leur état de conscience. Dix descripteurs ont été éliminés, car leur fréquence lors de la stimulation nociceptive était inférieure à 5% ou leur fiabilité insuffisante. Les descripteurs physiologiques ont tous été supprimés en raison de leur faible variabilité et d'une fiabilité inter juge problématique. Les résultats montrent que la validité concomitante, c'est-à-dire la corrélation entre l'auto- évaluation du patient et les mesures réalisées avec les descripteurs, est satisfaisante lors de stimulation nociceptive {rs=0,527, p=0,003, n=30). Par contre la validité convergente, qui vérifiait l'association entre l'évaluation de la douleur par l'infirmière en charge du patient et les mesures réalisés avec les descripteurs, ainsi que la validité divergente, qui vérifiait si les indicateurs discriminent entre la stimulation nociceptive et le repos, mettent en évidence des résultats variables en fonction de l'état de conscience des patients. Ces résultats soulignent la nécessité d'étudier les descripteurs de la douleur chez des patients cérébrolésés en fonction du niveau de conscience et de considérer l'hétérogénéité de cette population dans la conception d'un instrument d'évaluation de la douleur pour les personnes cérébrolésées non communicantes aux soins intensifs. - Pain is frequent in the intensive care unit (ICU) and its management is a major issue for nurses. The assessment of pain is a prerequisite for appropriate pain management. However, pain assessment is difficult when patients are unable to communicate about their experience and nurses have to base their evaluation on external signs. Clinical practice guidelines highlight the need to use behavioral scales that have been validated for nonverbal patients. Current behavioral pain tools for ICU patients unable to communicate may not be appropriate for nonverbal brain-injured ICU patients, as they demonstrate specific responses to pain. This study aimed to identify, describe and validate pain indicators and descriptors in brain-injured ICU patients. A mixed multiphase method design with a quantitative dominant was chosen for this study. The first phase aimed to identify indicators and descriptors of pain for nonverbal brain- injured ICU patients using data from three sources: an integrative literature review, a consultation using the nominal group technique with 18 experienced clinicians (12 nurses and 6 physicians) and the results of an observational pilot study with 10 traumatic brain injured patients. The results of this first phase identified 6 indicators and 47 behavioral, vocal and physiological descriptors of pain that could be included in a pain assessment tool for this population. The sequential phase two tested the psychometric properties of the list of previously identified indicators and descriptors. Content validity was tested with 10 clinical and 4 scientific experts for pertinence and comprehensibility using a structured questionnaire. This process resulted in 33 descriptors to be selected out of 47 previously identified, and six validated indicators. Then, the psychometric properties of the descriptors and indicators were tested at rest, during non nociceptive stimulation and nociceptive stimulation (turning) in a sample of 116 brain-injured ICLI patients who were hospitalized in two university centers. Results showed important variations in the descriptors observed during the nociceptive stimulation, probably due to the heterogeneity of patients' level of consciousness. Ten descriptors were excluded, as they were observed less than 5% of the time or their reliability was insufficient. All physiologic descriptors were deleted as they showed little variability and inter observer reliability was lacking. Concomitant validity, testing the association between patients' self report of pain and measures performed using the descriptors, was acceptable during nociceptive stimulation (rs=0,527, p=0,003, n=30). However, convergent validity ( testing for an association between the nurses' pain assessment and measures done with descriptors) and divergent validity (testing for the ability of the indicators to discriminate between rest and a nociceptive stimulation) varied according to the level of consciousness These results highlight the need to study pain descriptors in brain-injured patients with different level of consciousness and to take into account the heterogeneity of this population forthe conception of a pain assessment tool for nonverbal brain-injured ICU patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resection of midline skull base lesions involve approaches needing extensive neurovascular manipulation. Transnasal endoscopic approach (TEA) is minimally invasive and ideal for certain selected lesions of the anterior skull base. A thorough knowledge of endonasal endoscopic anatomy is essential to be well versed with its surgical applications and this is possible only by dedicated cadaveric dissections. The goal in this study was to understand endoscopic anatomy of the orbital apex, petrous apex and the pterygopalatine fossa. Six cadaveric heads (3 injected and 3 non injected) and 12 sides, were dissected using a TEA outlining systematically, the steps of surgical dissection and the landmarks encountered. Dissection done by the "2 nostril, 4 hands" technique, allows better transnasal instrumentation with two surgeons working in unison with each other. The main surgical landmarks for the orbital apex are the carotid artery protuberance in the lateral sphenoid wall, optic nerve canal, lateral optico-carotid recess, optic strut and the V2 nerve. Orbital apex includes structures passing through the superior and inferior orbital fissure and the optic nerve canal. Vidian nerve canal and the V2 are important landmarks for the petrous apex. Identification of the sphenopalatine artery, V2 and foramen rotundum are important during dissection of the pterygopalatine fossa. In conclusion, the major potential advantage of TEA to the skull base is that it provides a direct anatomical route to the lesion without traversing any major neurovascular structures, as against the open transcranial approaches which involve more neurovascular manipulation and brain retraction. Obviously, these approaches require close cooperation and collaboration between otorhinolaryngologists and neurosurgeons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Several scores are commonly used to evaluate patients' postoperative satisfaction after lateral ankle ligament repair, including: AOFAS, FAAM, CAIT and CAIS. Comparing published studies in the literature is difficult, as the same patient can have markedly different results depending on which scoring system is used. The current study aims to address this gap in the literature by developing a system to compare these tests, to allow better analysis and comparison of published studies. Patients and methods: This is a retrospective cohort study of 47 patients following lateral ankle ligament repair using a modified Broström-Gould technique. All patients were operated between 2005 and 2010 by a single surgeon and followed the same post operative rehabilitation protocol. Six patients were excluded from the study because of concomitant surgery. Patients were assessed by an independent observer. We used the Pearson correlation coefficient to analyse the concordance of the scores, as well as scatter plots to assess the linear relationship between them. Results: A linear distribution between the scores was found when the results were analysed using scatter plots. We were thus able to use the Pearson correlation coefficient to evaluate the relationship between each of the different postoperative scores. The correlation was found to be above 0.5 in all cases except for the comparison between the CAIT and the FAAM for the activities of daily living (0.39). We were, therefore, able to compare the results obtained and assess the relative concordance of the scoring systems. The results showed that the more specific the scale is, the worst the score is and inversely. So the CAIT and the CAIS appeared to be more severe than the AOFAS and the FAAM measuring the activities of daily living. The sports subscale of the FAAM demonstrated intermediate results. Conclusion: This study outlines a system to compare different postoperative scores commonly used to evaluate outcome after ankle stabilization surgery. The impact of this study is that it makes comparison of published studies easier, even though they use a variety of different clinical scores, thus facilitating better outcome analysis of operative techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: We examined the correlation between clinical wear rates of restorative materials and enamel (TRAC Research Foundation, Provo, USA) and the results of six laboratory test methods (ACTA, Alabama (generalized, localized), Ivoclar (vertical, volumetric), Munich, OHSU (abrasion, attrition), Zurich). METHODS: Individual clinical wear data were available from clinical trials that were conducted by TRAC Research Foundation (formerly CRA) together with general practitioners. For each of the n=28 materials (21 composite resins for intra-coronal restorations [20 direct and 1 indirect], 5 resin materials for crowns, 1 amalgam, enamel) a minimum of 30 restorations had been placed in posterior teeth, mainly molars. The recall intervals were up to 5 years with the majority of materials (n=27) being monitored, however, only for up to 2 years. For the laboratory data, the databases MEDLINE and IADR abstracts were searched for wear data on materials which were also clinically tested by TRAC Research Foundation. Only those data for which the same test parameters (e.g. number of cycles, loading force, type of antagonist) had been published were included in the study. A different quantity of data was available for each laboratory method: Ivoclar (n=22), Zurich (n=20), Alabama (n=17), OHSU and ACTA (n=12), Munich (n=7). The clinical results were summed up in an index and a linear mixed model was fitted to the log wear measurements including the following factors: material, time (0.5, 1, 2 and 3 years), tooth (premolar/molar) and gender (male/female) as fixed effects, and patient as random effect. Relative ranks were created for each material and method; the same was performed with the clinical results. RESULTS: The mean age of the subjects was 40 (±12) years. The materials had been mostly applied in molars (81%) and 95% of the intracoronal restorations were Class II restorations. The mean number of individual wear data per material was 25 (range 14-42). The mean coefficient of variation of clinical wear data was 53%. The only significant correlation was reached by OHSU (abrasion) with a Spearman r of 0.86 (p=0.001). Zurich, ACTA, Alabama generalized wear and Ivoclar (volume) had correlation coefficients between 0.3 and 0.4. For Zurich, Alabama generalized wear and Munich, the correlation coefficient improved if only composites for direct use were taken into consideration. The combination of different laboratory methods did not significantly improve the correlation. SIGNIFICANCE: The clinical wear of composite resins is mainly dependent on differences between patients and less on the differences between materials. Laboratory methods to test conventional resins for wear are therefore less important, especially since most of them do not reflect the clinical wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work is focused on the development of a methodology for the use of chemical characteristic of tire traces to help answer the following question: "Is the offending tire at the origin of the trace found on the crime scene?". This methodology goes from the trace sampling on the road to statistical analysis of its chemical characteristics. Knowledge about the composition and manufacture of tread tires as well as a review of instrumental techniques used for the analysis of polymeric materials were studied to select, as an ansi vi cal technique for this research, pyrolysis coupled to a gas Chromatograph with a mass spectrometry detector (Py-GC/MS). An analytical method was developed and optimized to obtain the lowest variability between replicates of the same sample. Within-variability of the tread was evaluated regarding width and circumference with several samples taken from twelve tires of different brands and/or models. The variability within each of the treads (within-variability) and between the treads (between-variability) could be quantified. Different statistical methods have shown that within-variability is lower than between-variability, which helped differentiate these tires. Ten tire traces were produced with tires of different brands and/or models by braking tests. These traces have been adequately sampled using sheets of gelatine. Particles of each trace were analysed using the same methodology as for the tires at their origin. The general chemical profile of a trace or of a tire has been characterized by eighty-six compounds. Based on a statistical comparison of the chemical profiles obtained, it has been shown that a tire trace is not differentiable from the tire at its origin but is generally differentiable from tires that are not at its origin. Thereafter, a sample containing sixty tires was analysed to assess the discrimination potential of the developed methodology. The statistical results showed that most of the tires of different brands and models are differentiable. However, tires of the same brand and model with identical characteristics, such as country of manufacture, size and DOT number, are not differentiable. A model, based on a likelihood ratio approach, was chosen to evaluate the results of the comparisons between the chemical profiles of the traces and tires. The methodology developed was finally blindly tested using three simulated scenarios. Each scenario involved a trace of an unknown tire as well as two tires possibly at its origin. The correct results for the three scenarios were used to validate the developed methodology. The different steps of this work were useful to collect the required information to test and validate the underlying assumption that it is possible to help determine if an offending tire » or is not at the origin of a trace, by means of a statistical comparison of their chemical profile. This aid was formalized by a measure of the probative value of the evidence, which is represented by the chemical profile of the trace of the tire. - Ce travail s'est proposé de développer une méthodologie pour l'exploitation des caractéristiques chimiques des traces de pneumatiques dans le but d'aider à répondre à la question suivante : «Est-ce que le pneumatique incriminé est ou n'est pas à l'origine de la trace relevée sur les lieux ? ». Cette méthodologie s'est intéressée du prélèvement de la trace de pneumatique sur la chaussée à l'exploitation statistique de ses caractéristiques chimiques. L'acquisition de connaissances sur la composition et la fabrication de la bande de roulement des pneumatiques ainsi que la revue de techniques instrumentales utilisées pour l'analyse de matériaux polymériques ont permis de choisir, comme technique analytique pour la présente recherche, la pyrolyse couplée à un chromatographe en phase gazeuse avec un détecteur de spectrométrie de masse (Py-GC/MS). Une méthode analytique a été développée et optimisée afin d'obtenir la plus faible variabilité entre les réplicas d'un même échantillon. L'évaluation de l'intravariabilité de la bande de roulement a été entreprise dans sa largeur et sa circonférence à l'aide de plusieurs prélèvements effectués sur douze pneumatiques de marques et/ou modèles différents. La variabilité au sein de chacune des bandes de roulement (intravariabilité) ainsi qu'entre les bandes de roulement considérées (intervariabilité) a pu être quantifiée. Les différentes méthodes statistiques appliquées ont montré que l'intravariabilité est plus faible que l'intervariabilité, ce qui a permis de différencier ces pneumatiques. Dix traces de pneumatiques ont été produites à l'aide de pneumatiques de marques et/ou modèles différents en effectuant des tests de freinage. Ces traces ont pu être adéquatement prélevées à l'aide de feuilles de gélatine. Des particules de chaque trace ont été analysées selon la même méthodologie que pour les pneumatiques à leur origine. Le profil chimique général d'une trace de pneumatique ou d'un pneumatique a été caractérisé à l'aide de huitante-six composés. Sur la base de la comparaison statistique des profils chimiques obtenus, il a pu être montré qu'une trace de pneumatique n'est pas différenciable du pneumatique à son origine mais est, généralement, différenciable des pneumatiques qui ne sont pas à son origine. Par la suite, un échantillonnage comprenant soixante pneumatiques a été analysé afin d'évaluer le potentiel de discrimination de la méthodologie développée. Les méthodes statistiques appliquées ont mis en évidence que des pneumatiques de marques et modèles différents sont, majoritairement, différenciables entre eux. La méthodologie développée présente ainsi un bon potentiel de discrimination. Toutefois, des pneumatiques de la même marque et du même modèle qui présentent des caractéristiques PTD (i.e. pays de fabrication, taille et numéro DOT) identiques ne sont pas différenciables. Un modèle d'évaluation, basé sur une approche dite du likelihood ratio, a été adopté pour apporter une signification au résultat des comparaisons entre les profils chimiques des traces et des pneumatiques. La méthodologie mise en place a finalement été testée à l'aveugle à l'aide de la simulation de trois scénarios. Chaque scénario impliquait une trace de pneumatique inconnue et deux pneumatiques suspectés d'être à l'origine de cette trace. Les résultats corrects obtenus pour les trois scénarios ont permis de valider la méthodologie développée. Les différentes étapes de ce travail ont permis d'acquérir les informations nécessaires au test et à la validation de l'hypothèse fondamentale selon laquelle il est possible d'aider à déterminer si un pneumatique incriminé est ou n'est pas à l'origine d'une trace, par le biais d'une comparaison statistique de leur profil chimique. Cette aide a été formalisée par une mesure de la force probante de l'indice, qui est représenté par le profil chimique de la trace de pneumatique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intraoperative cardiac imaging plays a key role during transcatheter aortic valve replacement. In recent years, new techniques and new tools for improved image quality and virtual navigation have been proposed, in order to simplify and standardize stent valve positioning and implantation. But routine performance of the new techniques may require major economic investments or specific knowledge and skills and, for this reason, they may not be accessible to the majority of cardiac centres involved in transcatheter valve replacement projects. Additionally, they still require injections of contrast medium to obtain computed images. Therefore, we have developed and describe here a very simple and intuitive method of positioning balloon-expandable stent valves, which represents the evolution of the 'dumbbell' technique for echocardiography-guided transcatheter valve replacement without angiography. This method, based on the partial inflation of the balloon catheter during positioning, traps the crimped valve in the aortic valve orifice and, consequently, very near to the ideal landing zone. It does not require specific echocardiographic knowledge; it does not require angiographies that increase the risk of postoperative kidney failure in elderly patients, and it can be also performed in centres not equipped with a hybrid operating room.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Freehand positioning of the femoral drill guide is difficult during hip resurfacing and the surgeon is often unsure of the implant position achieved peroperatively. The purpose of this study was to find out whether, by using a navigation system, acetabular and femoral component positioning could be made easier and more precise. Eighteen patients operated on by the same surgeon were matched by sex, age, BMI, diagnosis and ASA score (nine patients with computer assistance, nine with the regular ancillary). Pre-operative planning was done on standard AP and axial radiographs with CT scan views for the computer-assisted operations. The final position of implants was evaluated by the same radiographs for all patients. The follow-up was at least 1 year. No difference between both groups in terms of femoral component position was observed (p > 0.05). There was also no difference in femoral notching. A trend for a better cup position was observed for the navigated hips, especially for cup anteversion. There was no additional operating time for the navigated hips. Hip navigation for resurfacing surgery may allow improved visualisation and hip implant positioning, but its advantage probably will be more obvious with mini-incisions than with regular incision surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A consecutive series of 353 patients who underwent Lichtenstein mesh repair for inguinal hernia from the 1st of July 1994 to the 30th of July 1995 were studied. We analysed our indication, technique, complications, follow-up and outcome. Special consideration was given to the advantages and acceptance of day-case surgery. Our results suggest that the Lichtenstein repair should be considered as a new standard procedure, especially outside of hernia centres.