26 resultados para Shoe lift

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monitoring of posture allocations and activities enables accurate estimation of energy expenditure and may aid in obesity prevention and treatment. At present, accurate devices rely on multiple sensors distributed on the body and thus may be too obtrusive for everyday use. This paper presents a novel wearable sensor, which is capable of very accurate recognition of common postures and activities. The patterns of heel acceleration and plantar pressure uniquely characterize postures and typical activities while requiring minimal preprocessing and no feature extraction. The shoe sensor was tested in nine adults performing sitting and standing postures and while walking, running, stair ascent/descent and cycling. Support vector machines (SVMs) were used for classification. A fourfold validation of a six-class subject-independent group model showed 95.2% average accuracy of posture/activity classification on full sensor set and over 98% on optimized sensor set. Using a combination of acceleration/pressure also enabled a pronounced reduction of the sampling frequency (25 to 1 Hz) without significant loss of accuracy (98% versus 93%). Subjects had shoe sizes (US) M9.5-11 and W7-9 and body mass index from 18.1 to 39.4 kg/m2 and thus suggesting that the device can be used by individuals with varying anthropometric characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessment of locomotion through simple tests such as timed up and go (TUG) or walking trials can provide valuable information for the evaluation of treatment and the early diagnosis of people with Parkinson's disease (PD). Common methods used in clinics are either based on complex motion laboratory settings or simple timing outcomes using stop watches. The goal of this paper is to present an innovative technology based on wearable sensors on-shoe and processing algorithm, which provides outcome measures characterizing PD motor symptoms during TUG and gait tests. Our results on ten PD patients and ten age-matched elderly subjects indicate an accuracy ± precision of 2.8 ± 2.4 cm/s and 1.3 ± 3.0 cm for stride velocity and stride length estimation compared to optical motion capture, with the advantage of being practical to use in home or clinics without any discomfort for the subject. In addition, the use of novel spatio-temporal parameters, including turning, swing width, path length, and their intercycle variability, was also validated and showed interesting tendencies for discriminating patients in ON and OFF states and control subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to distinguish dysfunctional gait; clinicians require a measure of reference gait parameters for each population. This study provided normative values for widely used parameters in more than 1400 able-bodied adults over the age of 65. We also measured the foot clearance parameters (i.e., height of the foot above ground during swing phase) that are crucial to understand the complex relationship between gait and falls as well as obstacle negotiation strategies. We used a shoe-worn inertial sensor on each foot and previously validated algorithms to extract the gait parameters during 20 m walking trials in a corridor at a self-selected pace. We investigated the difference of the gait parameters between male and female participants by considering the effect of age and height factors. Besides; we examined the inter-relation of the clearance parameters with the gait speed. The sample size and breadth of gait parameters provided in this study offer a unique reference resource for the researchers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Hidradenitis suppurativa of the groin is a chronic, relapsing inflammatory disease of the skin and subcutaneous tissues. Radical surgical excision is the treatment of choice. Often split-skin grafting or wound healing by secondary intention are used for defect closure, sometimes with disfiguring results. We describe our experience with radical excision of localised inguinal hidradenitis suppurativa and immediate defect closure with a medial thigh lift. PATIENTS AND METHODS: Our hospital database was searched for all patients presenting to our institution for surgical treatment of hidradenitis suppurativa between 2001 and 2006. Only patients with hidradenitis confined to the groin were included. Exclusion criteria were simple abscess incisions, recurrence after previous grafting or flap surgery and extension of the disease outside the groin and presence of clinical signs of infection at the time of surgery. We documented patient demographics, sizes of defects, complications, time of follow-up, recurrences and patient satisfaction. RESULTS: A total of 8 patients with localised inguinal hidradenitis suppurativa were identified and 15 thigh lifts were performed. Defect size assessed on pathologic examination of the excised specimens averaged 15.9 cm x 4.3 cm x 1.3 cm (length x width x depth). All wounds but one healed primarily. Functional and aesthetic results were satisfactory. No major complications and no irritations of the genital area were observed. No recurrences were observed either. CONCLUSION: We propose the medial thigh lift to be considered for immediate defect closure after radical excision of localised inguinal hidradenitis suppurativa provided that no perifocal signs of infection are present after debridement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intravoxel incoherent motion (IVIM) MRI is a method to extract microvascular blood flow information out of diffusion-weighted images acquired at multiple b-values. We hypothesized that IVIM can identify the muscles selectively involved in a specific task, by measuring changes in activity-induced local muscular perfusion after exercise. We tested this hypothesis using a widely used clinical maneuver, the lift-off test, which is known to assess specifically the subscapularis muscle functional integrity. Twelve shoulders from six healthy male volunteers were imaged at 3 T, at rest, as well as after a lift-off test hold against resistance for 30 s, 1 and 2 min respectively, in three independent sessions. IVIM parameters, consisting of perfusion fraction (f), diffusion coefficient (D), pseudo-diffusion coefficient D* and blood flow-related fD*, were estimated within outlined muscles of the rotator cuff and the deltoid bundles. The mean values at rest and after the lift-off tests were compared in each muscle using a one-way ANOVA. A statistically significant increase in fD* was measured in the subscapularis, after a lift-off test of any duration, as well as in D. A fD* increase was the most marked (30 s, +103%; 1 min, +130%; 2 min, +156%) and was gradual with the duration of the test (in 10(-3) mm(2) /s: rest, 1.41 ± 0.50; 30 s, 2.86 ± 1.17; 1 min, 3.23 ± 1.22; 2 min, 3.60 ± 1.21). A significant increase in fD* and D was also visible in the posterior bundle of the deltoid. No significant change was consistently visible in the other investigated muscles of the rotator cuff and the other bundles of the deltoid. In conclusion, IVIM fD* allows the demonstration of a task-related microvascular perfusion increase after a specific task and suggests a direct relationship between microvascular perfusion and the duration of the effort. It is a promising method to investigate non-invasively skeletal muscle physiology and clinical perfusion-related muscular disorders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fall prevention in elderly subjects is often based on training and rehabilitation programs that include mostly traditional balance and strength exercises. By applying such conventional interventions to improve gait performance and decrease fall risk, some important factors are neglected such as the dynamics of the gait and the motor learning processes. The EU project "Self Mobility Improvement in the eLderly by counteractING falls" (SMILING project) aimed to improve age-related gait and balance performance by using unpredicted external perturbations during walking through motorized shoes that change insole inclination at each stance. This paper describes the shoe-worn inertial module and the gait analysis method needed to control in real-time the shoe insole inclination during training, as well as gait spatio-temporal parameters obtained during long distance walking before and after the 8-week training program that assessed the efficacy of training with these motorized shoes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A child's natural gait pattern may be affected by the gait laboratory environment. Wearable devices using body-worn sensors have been developed for gait analysis. The purpose of this study was to validate and explore the use of foot-worn inertial sensors for the measurement of selected spatio-temporal parameters, based on the 3D foot trajectory, in independently walking children with cerebral palsy (CP). We performed a case control study with 14 children with CP aged 6-15 years old and 15 age-matched controls. Accuracy and precision of the foot-worn device were measured using an optical motion capture system as the reference system. Mean accuracy±precision for both groups was 3.4±4.6cm for stride length, 4.3±4.2cm/s for speed and 0.5±2.9° for strike angle. Longer stance and shorter swing phases with an increase in double support were observed in children with CP (p=0.001). Stride length, speed and peak angular velocity during swing were decreased in paretic limbs, with significant differences in strike and lift-off angles. Children with cerebral palsy showed significantly higher inter-stride variability (measured by their coefficient of variation) for speed, stride length, swing and stance. During turning trajectories speed and stride length decreased significantly (p<0.01) for both groups, whereas stance increased significantly (p<0.01) in CP children only. Foot-worn inertial sensors allowed us to analyze gait spatiotemporal data outside a laboratory environment with good accuracy and precision and congruent results with what is known of gait variations during linear walking in children with CP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In-shoe loading patterns were examined in each foot (back and front) separately during two types of tennis serve [first (or flat) and second (or twist) serve] and two service stance styles [foot-up (back foot is moved forward next to front foot for push-off) and foot-back (feet remain at the same relative level)]. Ten competitive tennis players completed five trials for each type of serve and service stance style in random order. Plantar pressure distribution was recorded using Pedar insoles divided into nine areas for analysis. Mean and peak pressures (+15.2%, P < 0.01 and +12.8%, P < 0.05) as well as maximal forces (+20.2%, P < 0.01) were higher under the lateral forefoot of the front foot in first than in second serves, while mean forces were higher (+17.2%, P < 0.05) under the lesser toes. Relative load was higher on the lateral forefoot (+20.4%, P < 0.05) but lower (-32.5%, P < 0.05) on the medial heel of the front foot with foot-up compared with foot-back stance. Using a foot-up stance, loading of the back foot was higher (+31.8%, P < 0.01) under the lateral mid-foot but lower (-29.9%, P < 0.01) under the medial forefoot. The type of serve and the stance style adopted have a significant effect on foot loading. Such findings might help improve mechanical efficiency of the serve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Throughout much of the Quaternary Period, inhospitable environmental conditions above the Arctic Circle have been a formidable barrier separating most marine organisms in the North Atlantic from those in the North Pacific(1,2). Rapid warming has begun to lift this barrier(3), potentially facilitating the interchange of marine biota between the two seas(4). Here, we forecast the potential northward progression of 515 fish species following climate change, and report the rate of potential species interchange between the Atlantic and the Pacific via the Northwest Passage and the Northeast Passage. For this, we projected niche-based models under climate change scenarios and simulated the spread of species through the passages when climatic conditions became suitable. Results reveal a complex range of responses during this century, and accelerated interchange after 2050. By 2100 up to 41 species could enter the Pacific and 44 species could enter the Atlantic, via one or both passages. Consistent with historical and recent biodiversity interchanges(5,6), this exchange of fish species may trigger changes for biodiversity and food webs in the North Atlantic and North Pacific, with ecological and economic consequences to ecosystems that at present contribute 39% to global marine fish landings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to compare foot plantar pressure distribution while jogging and running in highly trained adolescent runners. Eleven participants performed two constant-velocity running trials either at jogging (11.2 ± 0.9 km/h) or running (17.8 ± 1.4 km/h) pace on a treadmill. Contact area (CA in cm(2)), maximum force (F(max) in N), peak pressure (PP in kPa), contact time (CT in ms), and relative load (force time integral in each individual region divided by the force time integral for the total plantar foot surface, in %) were measured in nine regions of the right foot using an in-shoe plantar pressure device. Under the whole foot, CA, F(max) and PP were lower in jogging than in running (-1.2% [p<0.05], -12.3% [p<0.001] and -15.1% [p<0.01] respectively) whereas CT was higher (+20.1%; p<0.001). Interestingly, we found an increase in relative load under the medial and central forefoot regions while jogging (+6.7% and +3.7%, respectively; [p<0.05]), while the relative load under the lesser toes (-8.4%; p<0.05) was reduced. In order to prevent overloading of the metatarsals in adolescent runners, excessive mileage at jogging pace should be avoided.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Indications for arthrodesis of the first metatarsophalangeal joint (MTP1) are commonly arthrosis (hallux rigidus), rheumatoid arthritis, failed hallux valgus surgery, severe hallux valgus, infectious arthritis, fractures and neuroarthropathies. Many reports focus on technical and radiological issues but few studies emphasize the functional outcome considering daily activities, sports and expectation of the patient. Method: We retrospectively reviewed the patients who underwent MTP1-arthrodesis from 2002 to 2005 in our institution. Clinical and radiological results were assessed but we specially focussed on the functional outcome. Scoring systems used were the SF-12, EQ-5D, PASI, FFI and AOFAS (10 points given to MTP1 mobility) scales. Results: 61 of 64 consecutive patients were evaluated. Female to male ratio was 49:15, mean age at surgery was 67 years, the average follow up was 29 month. Even if radiological consolidation was incomplete in 18 patients, all patients had a clinically stable and rigid arthrodesis. Mean AOFAS score was 87 (24-100) points at follow up. The FFI was 5.91% (0-66%). Patient satisfaction was excellent in 37 patients (60%), good in 18 (30%), fair in 5(8%) and poor in1 (2%). EQ- 5D was 0.7 (0.4-1).40 patients (66%) estimated their cosmetic result as excellent, 15 (25%) as good, 4(6%) as fair and 2 (3%)as poor. 10 patients (16%) had no shoe wear limitation , 48 (79%) had to wear comfortable shoes and 3 (5%) needed orthopaedic wearing. Professionally 34 patients (56%) had better performances, 18 (26%) had no change and 9 (18%) had aggravation of their capacities but this was due to other health reasons. In sports, 16 patients (26%) had better performances, 35 patients (57%) no change and 10 (17%) were worse as consequence of other health problems for 7. Finally, 56 patients (92%) would recommend the operation and 5 (8%) would not. Conclusion: Experience of clinical practice suggests that the idea of fusing the first MTP joint is initially frequently disregarded by the patients because they fear to be limited by a rigid forefoot. Our results show, in fact, that this procedure can be proposed for numerous pathological situations with the perspective of good to excellent outcome in terms of function and quality of life in the majority of cases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Dynamics is a central aspect of ski jumping, particularly during take-off and stable flight. Currently, measurement systems able to measure ski jumping dynamics (e.g. 3D cameras, force plates) are complex and only available in few research centres worldwide. This study proposes a method to determine dynamics using a wearable inertial sensor-based system which can be used routinely on any ski jumping hill. The system automatically calculates characteristic dynamic parameters during take-off (position and velocity of the centre of mass perpendicular to the table, force acting on the centre of mass perpendicular to the table and somersault angular velocity) and stable flight (total aerodynamic force). Furthermore, the acceleration of the ski perpendicular to the table was quantified to characterise the skis lift at take-off. The system was tested with two groups of 11 athletes with different jump distances. The force acting on the centre of mass, acceleration of the ski perpendicular to the table, somersault angular velocity and total aerodynamic force were different between groups and correlated with the jump distances. Furthermore, all dynamic parameters were within the range of prior studies based on stationary measurement systems, except for the centre of mass mean force which was slightly lower.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A significant part of daily energy expenditure may be attributed to non-exercise activity thermogenesis and exercise activity thermogenesis. Automatic recognition of postural allocations such as standing or sitting can be used in behavioral modification programs aimed at minimizing static postures. In this paper we propose a shoe-based device and related pattern recognition methodology for recognition of postural allocations. Inexpensive technology allows implementation of this methodology as a part of footwear. The experimental results suggest high efficiency and reliability of the proposed approach.