27 resultados para Serviços on-line
em Université de Lausanne, Switzerland
Resumo:
Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.
Resumo:
The process of on-line generation of ultrapure dialysis fluid is a core prerequisite for the safe execution of modern renal replacement therapies such as on-line hemodiafiltration and high-flux hemodialysis. In these extracorporeal treatments with variable degrees of convection, significant volumes of plasma water are removed and replaced with dialysis fluid, which must occur without causing harm to the patient. Historically, on-line generation of sterile and pyrogen-free physiological substitution fluid by the process of membrane ultrafiltration of fresh dialysis fluid has its origin in hemofiltration, a purely convective therapy. Development of this and later therapies is described in the historical context of a successful effort over decades to overcome the above formidable challenge, which was provided jointly by pioneering clinical investigators and a resourceful dialysis industry.
Resumo:
The aim of this study is to investigate the influence of unusual writing positions on a person's signature, in comparison to a standard writing position. Ten writers were asked to sign their signature six times, in each of four different writing positions, including the standard one. In order to take into consideration the effect of the day-to-day variation, this same process was repeated over 12 sessions, giving a total of 288 signatures per subject. The signatures were collected simultaneously in an off-line and on-line acquisition mode, using an interactive tablet and a ballpoint pen. Unidimensional variables (height to width ratio; time with or without in air displacement) and time-dependent variables (pressure; X and Y coordinates; altitude and azimuth angles) were extracted from each signature. For the unidimensional variables, the position effect was assessed through ANOVA and Dunnett contrast tests. Concerning the time-dependent variables, the signatures were compared by using dynamic time warping, and the position effect was evaluated through classification by linear discriminant analysis. Both of these variables provided similar results: no general tendency regarding the position factor could be highlighted. The influence of the position factor varies according to the subject as well as the variable studied. The impact of the session factor was shown to cover the impact that could be ascribed to the writing position factor. Indeed, the day-to-day variation has a greater effect than the position factor on the studied signature variables. The results of this study suggest guidelines for best practice in the area of signature comparisons and demonstrate the importance of a signature collection procedure covering an adequate number of sampling sessions, with a sufficient number of samples per session.
Resumo:
Phosphopeptides tagging reactions by dinuclear zinc(II) complexes (1,3-bis[bis(2-pyridylmethyl)amino]-propan-2-olato dizinc(II)3+, called tag) were performed with a dual-channel microsprayer in electrospray ionization mass spectrometry. The reaction is first studied ex situ and analyzed with a commercial electrospray source. In situ reactions (i.e., inside the Taylor cone) were achieved with a dual-channel microsprayer both with the tag synthesized chemically before the experiments and with the tag electrogenerated by in situ oxidation of a zinc electrode, also used to apply the electrospray current. The device consists of a polyimide microchip with two microchannels (20 microm x 50 microm x 1 cm) etched on each side of the structure and connecting only at the tip of the microchip. We demonstrate here that mixing two solutions with different physicochemical properties inside the Taylor cone can be used to selectively tag target molecules.
Resumo:
The aim of this work is to present a new concept, called on-line desorption of dried blood spots (on-line DBS), allowing the direct analysis of a dried blood spot coupled to liquid chromatography mass spectrometry device (LC/MS). The system is based on an inox cell which can receive a blood sample (10 microL) previously spotted on a filter paper. The cell is then integrated into LC/MS system where the analytes are desorbed out of the paper towards a column switching system ensuring the purification and separation of the compounds before their detection on a single quadrupole MS coupled to atmospheric pressure chemical ionisation (APCI) source. The described procedure implies that no pretreatment is necessary in spite the analysis is based on whole blood sample. To ensure the applicability of the concept, saquinavir, imipramine, and verapamil were chosen. Despite the use of a small sampling volume and a single quadrupole detector, on-line DBS allowed the analyses of these three compounds over their therapeutic concentrations from 50 to 500 ng/mL for imipramine and verapamil and from 100 to 1000 ng/mL for saquinavir. Moreover, the method showed good repeatability with relative standard deviation (RSD) lower than 15% based on two levels of concentration (low and high). Function responses were found to be linear over the therapeutic concentration for each compound and were used to determine the concentrations of real patient samples for saquinavir. Comparison of the founded values with those of a validated method used routinely in a reference laboratory showed a good correlation between the two methods. Moreover, good selectivity was observed ensuring that no endogenous or chemical components interfered with the quantitation of the analytes. This work demonstrates the feasibility and applicability of the on-line DBS procedure for bioanalysis.
Resumo:
An assay for the simultaneous analysis of pharmaceutical compounds and their metabolites from micro-whole blood samples (i.e. 5 microL) was developed using an on-line dried blood spot (on-line DBS) device coupled with hydrophilic interaction/reversed-phase (HILIC/RP) LC/MS/MS. Filter paper is directly integrated to the LC device using a homemade inox desorption cell. Without any sample pretreatment, analytes are desorbed from the paper towards an automated system of valves linking a zwitterionic-HILIC column to an RP C18 column. In the same run, the polar fraction is separated by the zwitterionic-HILIC column while the non-polar fraction is eluted on the RP C18. Both fractions are detected by IT-MS operating in full scan mode for the survey scan and in product ion mode for the dependant scan using an ESI source. The procedure was evaluated by the simultaneous qualitative analysis of four probes and their relative phase I and II metabolites spiked in whole blood. In addition, the method was successfully applied to the in vivo monitoring of buprenorphine metabolism after the administration of an intraperitoneal injection of 30 mg/kg on adult female Wistar rat.
Resumo:
BACKGROUND: HIV surveillance requires monitoring of new HIV diagnoses and differentiation of incident and older infections. In 2008, Switzerland implemented a system for monitoring incident HIV infections based on the results of a line immunoassay (Inno-Lia) mandatorily conducted for HIV confirmation and type differentiation (HIV-1, HIV-2) of all newly diagnosed patients. Based on this system, we assessed the proportion of incident HIV infection among newly diagnosed cases in Switzerland during 2008-2013. METHODS AND RESULTS: Inno-Lia antibody reaction patterns recorded in anonymous HIV notifications to the federal health authority were classified by 10 published algorithms into incident (up to 12 months) or older infections. Utilizing these data, annual incident infection estimates were obtained in two ways, (i) based on the diagnostic performance of the algorithms and utilizing the relationship 'incident = true incident + false incident', (ii) based on the window-periods of the algorithms and utilizing the relationship 'Prevalence = Incidence x Duration'. From 2008-2013, 3'851 HIV notifications were received. Adult HIV-1 infections amounted to 3'809 cases, and 3'636 of them (95.5%) contained Inno-Lia data. Incident infection totals calculated were similar for the performance- and window-based methods, amounting on average to 1'755 (95% confidence interval, 1588-1923) and 1'790 cases (95% CI, 1679-1900), respectively. More than half of these were among men who had sex with men. Both methods showed a continuous decline of annual incident infections 2008-2013, totaling -59.5% and -50.2%, respectively. The decline of incident infections continued even in 2012, when a 15% increase in HIV notifications had been observed. This increase was entirely due to older infections. Overall declines 2008-2013 were of similar extent among the major transmission groups. CONCLUSIONS: Inno-Lia based incident HIV-1 infection surveillance proved useful and reliable. It represents a free, additional public health benefit of the use of this relatively costly test for HIV confirmation and type differentiation.
Resumo:
A cortical visuomotor network, comprising the medial intraparietal sulcus (mIPS) and the dorsal premotor area (PMd), encodes the sensorimotor transformations required for the on-line control of reaching movements. How information is transmitted between these two regions and which pathways are involved, are less clear. Here, we use a multimodal approach combining repetitive transcranial magnetic stimulation (rTMS) and diffusion tensor imaging (DTI) to investigate whether structural connectivity in the 'reaching' circuit is associated to variations in the ability to control and update a movement. We induced a transient disruption of the neural processes underlying on-line motor adjustments by applying 1Hz rTMS over the mIPS. After the stimulation protocol, participants globally showed a reduction of the number of corrective trajectories during a reaching task that included unexpected visual perturbations. A voxel-based analysis revealed that participants exhibiting higher fractional anisotropy (FA) in the second branch of the superior longitudinal fasciculus (SLF II) suffered less rTMS-induced behavioral impact. These results indicate that the microstructural features of the white matter bundles within the parieto-frontal 'reaching' circuit play a prominent role when action reprogramming is interfered. Moreover, our study suggests that the structural alignment and cohesion of the white matter tracts might be used as a predictor to characterize the extent of motor impairments.
Resumo:
The use of the life history calendar (LHC) or the event history calendar as tools for collecting retrospective data has received increasing attention in many fields of social science and medicine. However, little research has examined the use of this method with web-based surveys. In this study, we adapted this method to an on-line setting to collect information about young adults' life histories, sexual behaviors, and substance use. We hypothesized that the LHC method would help respondents to date sensitive and non-sensitive events more precisely than when using a conventional questionnaire. We conducted an experimental design study comparing university students' responses to an on-line LHC and a conventional on-line question list. A test-retest design in which the respondents completed the survey again two weeks later was also applied to test the precision and reliability of the participants' dating of events. The results showed that whereas the numbers of sensitive and non-sensitive events were generally similar for the two on-line questionnaires, the responses obtained with the LHC were more consistent across the two administrations. Analyses of the respondents' on-line behavior while completing the LHC confirmed that respondents used the LHC's graphic interface to correct and reedit previous answers, thus decreasing data errors. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
The extension of traditional data mining methods to time series has been effectively applied to a wide range of domains such as finance, econometrics, biology, security, and medicine. Many existing mining methods deal with the task of change points detection, but very few provide a flexible approach. Querying specific change points with linguistic variables is particularly useful in crime analysis, where intuitive, understandable, and appropriate detection of changes can significantly improve the allocation of resources for timely and concise operations. In this paper, we propose an on-line method for detecting and querying change points in crime-related time series with the use of a meaningful representation and a fuzzy inference system. Change points detection is based on a shape space representation, and linguistic terms describing geometric properties of the change points are used to express queries, offering the advantage of intuitiveness and flexibility. An empirical evaluation is first conducted on a crime data set to confirm the validity of the proposed method and then on a financial data set to test its general applicability. A comparison to a similar change-point detection algorithm and a sensitivity analysis are also conducted. Results show that the method is able to accurately detect change points at very low computational costs. More broadly, the detection of specific change points within time series of virtually any domain is made more intuitive and more understandable, even for experts not related to data mining.
Resumo:
This article offers an overview of methodological difficulties that arise in the study of religions on video sharing websites (VSW). We suggest how to put these difficulties in perspective and how to overcome them. A typology lists the various forms of religions represented on this type of website. We will also try to understand why some religious groups have created their own video sharing websites. Finally we will give possible interpretations of this phenomenon and suggest some ways to use this type of material in academic research and teaching about religions. Cet article propose une vue d'ensemble des difficultés méthodologiques rencontrées dans l'étude des religions sur les sites web de partage de vidéos. Il propose des pistes pour relativiser et surmonter ces difficultés. Une typologie présente les différentes formes sous lesquelles on trouve des religions dans ce type de sites web. Nous tentons aussi de comprendre pourquoi certains groupes religieux ont créé leurs propres sites de partages de vidéos. Enfin, nous donnerons des possibles interprétations du phénomène et suggérerons comment on pourrait utiliser de ce type de matériel dans la recherche et l'enseignement académiques sur les religions.
Resumo:
The vision-for-action literature favours the idea that the motor output of an action - whether manual or oculomotor - leads to similar results regarding object handling. Findings on line bisection performance challenge this idea: healthy individuals bisect lines manually to the left of centre, and to the right of centre when using eye fixation. In case that these opposite biases for manual and oculomotor action reflect more universal compensatory mechanisms that cancel each other out to enhance overall accuracy, one would like to observe comparable opposite biases for other material. In the present study, we report on three independent experiments in which we tested line bisection (by hand, by eye fixation) not only for solid lines, but also for letter lines; the latter, when bisected manually, is known to result in a rightward bias. Accordingly, we expected a leftward bias for letter lines when bisected via eye fixation. Analysis of bisection biases provided evidence for this idea: manual bisection was more rightward for letter as compared to solid lines, while bisection by eye fixation was more leftward for letter as compared to solid lines. Support for the eye fixation observation was particularly obvious in two of the three studies, for which comparability between eye and hand action was increasingly adjusted (paper-pencil versus touch screen for manual action). These findings question the assumption that ocular motor and manual output are always inter-changeable, but rather suggest that at least for some situations ocular motor and manual output biases are orthogonal to each other, possibly balancing each other out.
Resumo:
Background: Fine particulate matter originating from traffic correlates with increased morbidity and mortality. An important source of traffic particles is brake wear of cars which contributes up to 20% of the total traffic emissions. The aim of this study was to evaluate potential toxicological effects of human epithelial lung cells exposed to freshly generated brake wear particles. Results: An exposure box was mounted around a car's braking system. Lung cells cultured at the air-liquid interface were then exposed to particles emitted from two typical braking behaviours ("full stop" and "normal deceleration"). The particle size distribution as well as the brake emission components like metals and carbons was measured on-line, and the particles deposited on grids for transmission electron microscopy were counted. The tight junction arrangement was observed by laser scanning microscopy. Cellular responses were assessed by measurement of lactate dehydrogenase (cytotoxicity), by investigating the production of reactive oxidative species and the release of the pro-inflammatory mediator interleukin-8. The tight junction protein occludin density decreased significantly (p < 0.05) with increasing concentrations of metals on the particles (iron, copper and manganese, which were all strongly correlated with each other). Occludin was also negatively correlated with the intensity of reactive oxidative species. The concentrations of interleukin-8 were significantly correlated with increasing organic carbon concentrations. No correlation was observed between occludin and interleukin-8, nor between reactive oxidative species and interleukin-8. Conclusion: These findings suggest that the metals on brake wear particles damage tight junctions with a mechanism involving oxidative stress. Brake wear particles also increase pro-inflammatory responses. However, this might be due to another mechanism than via oxidative stress. [Authors]
Resumo:
Background and objective: Oral anti-cancer treatments have expanded rapidly over the last years. While taking oral tablets at home ensures a better quality of life, it also exposes patients to the risk of sub-optimal adherence. The objective of this study is to assess how well ambulatory cancer patients execute their prescribed dosing regimen while they are engaged with continuous anti-cancer treatments. Design: This is an on-going longitudinal study. Consecutive patients starting an oral treatment are proposed to enter the study by the oncologist. Then they are referred to the pharmacy, where their oral anticancer treatment is dispensed in a Medication Event Monitoring System (MEMSTM), which records date and time of each opening of the drug container. Electronically compiled dosing history data from the MEMS are summarized and used as feedback during semistructured interviews with the pharmacist, which are dedicated to prevention and management of side effects. Interviews are scheduled before each medical visit. Report of the interview is available to the oncologist via an on-line secured portal. Setting: Seamless care approach between a Multidisciplinary Oncology Center and the Pharmacy of an Ambulatory Care and Community Medicine Department. Main outcome measures: For each patient, the comparison between the electronically compiled dosing history and the prescribed regimen was summarized using a daily binary indicator indicating whether yes or no the patient has taken the medication as prescribed. Results: Study started in March 2008. Among 22 eligible patients, 19 were included (11 men, median age 63 years old) and 3 (14%) refused to participate. 15 patients were prescribed a QD regimen, 3 patients a BID and 1 patient switched from QD to BID during follow-up. Median follow up was 182 days (IQR 72-252). Early discontinuation happened in four patients: side effects (n = 1), psychiatric reasons (n = 1), cancer progression (n = 1) and death (n = 1). On average, the daily number of medications was taken as prescribed in 99% of the follow-up days. Conclusions: Execution of the prescribed dosing regimens was almost perfect during the first 6 months. Maintaining this high degree of regimen execution and persistence over time might however be challenging in this population and need therefore to be confirmed in larger and longer follow-up cohort studies.