167 resultados para Self monitoring blood glycose
em Université de Lausanne, Switzerland
Resumo:
There is a sustained controversy in the literature about the role and utility of self-monitoring of blood glucose (SMBG) in type 2 diabetes. The study results in this field do not provide really useful clues for the integration of SMBG in the follow-up of the individual patient, because they are based on a misconception of SMBG. It is studied as if it was a medical treatment whose effect on glycemic control is to be isolated. However, SMBG has no such intrinsic effect. It gains its purpose only as an inseparable component of a comprehensive and structured educational strategy. To be appropriate this strategy cannot be based on the health care professionals' view on diabetes only. It rather has to be tailored to the individual patient's needs through an ongoing process of shared reflection with him.
Resumo:
Background: Pre-existing psychological factors can strongly influence coping with type 1 diabetes mellitus and interfere with self-monitoring. Psychiatric disorders seem to be positively associated with poor metabolic control. We present a case of extreme compulsive blood testing due to obsessive fear of hypoglycemia in an adolescent with type 1 diabetes mellitus. Case report: Type 1 diabetes mellitus (anti GAD-antibodies 2624 U/l, norm < 9.5) was diagnosed in a boy aged 14.3 years [170 cm (+ 0.93 SDS), weight 50.5 kg (+ 0.05 SDS)]. Laboratory work-up showed no evidence for other autoimmune disease. Family and past medical history were unremarkable. Growth and developmental milestones were normal. Insulin-analog based basal-bolus regime was initiated, associated to standard diabetic education. Routine psychological evaluation performed at the onset of diabetes revealed intermittent anxiety and obsessivecompulsive traits. Accordingly, a close psychiatric follow-up was initiated for the patient and his family. An adequate metabolic control (HbA1c drop from >14 to 8%) was achieved within 3 months, attributed to residual -cell function. In the following 6 months, HbA1c rose unexpectedly despite seemingly adequate adaptations of insulin doses. Obsessive fear of hypoglycemia leading to a severe compulsive behavior developed progressively with as many as 68 glycemia measurements per day (mean over 1 week). The patient reported that he could not bear leaving home with glycemia < 15 mmol/l, ending up with school eviction and severe intra-familial conflict. Despite intensive psychiatric outpatient support, HbA1c rose rapidly to >14% with glycemia-testing reaching peaks of 120 tests/day. The situation could only be discontinued through psychiatric hospitalization with intensive behavioral training. As a result, adequate metabolic balance was restored (HbA1c value: 7.1 %) with acceptable 10-15 daily glycemia measurements. Discussion: The association of overt psychiatric disorders to type 1 diabetes mellitus is very rare in the pediatric age group. It can lead to a pathological behavior with uncontrolled diabetes. Such exceptional situations require long-term admissions with specialized psychiatric care. Slow acceptation of a "less is better" principle in glycemia testing and amelioration of metabolic control are difficult to achieve.
Resumo:
AIM: In type 1 diabetic patients (T1DM), nocturnal hypoglycaemias (NH) are a serious complication of T1DM treatment; self-monitoring of blood glucose (SMBG) is recommended to detect them. However, the majority of NH remains undetected on an occasional SMBG done during the night. An alternative strategy is the Continuous glucose monitoring (CGMS), which retrospectively shows the glycaemic profile. The aims of this retrospective study were to evaluate the true incidence of NH in T1DM, the best SMBG time to predict NH, the relationship between morning hyperglycaemia and NH (Somogyi phenomenon) and the utility of CGMS to reduce NH. METHODS: Eighty-eight T1DM who underwent a CGMS exam were included. Indications for CGMS evaluation, hypoglycaemias and correlation with morning hyperglycaemias were recorded. The efficiency of CGMS to reduce the suspected NH was evaluated after 6-9 months. RESULTS: The prevalence of NH was 67% (32% of them unsuspected). A measured hypoglycaemia at bedtime (22-24 h) had a sensitivity of 37% to detect NH (OR=2.37, P=0.001), while a single measure < or =4 mmol/l at 3-hour had a sensitivity of 43% (OR=4.60, P<0.001). NH were not associated with morning hyperglycaemias but with morning hypoglycaemias (OR=3.95, P<0.001). After 6-9 months, suspicions of NH decreased from 60 to 14% (P<0.001). CONCLUSION: NH were highly prevalent and often undetected. SMBG at bedtime, which detected hypoglycaemia had sensitivity almost equal to that of 3-hour and should be preferred because it is easier to perform. Somogyi phenomenon was not observed. CGMS is useful to reduce the risk of NH in 75% of patients.
Resumo:
Rapport de synthèse : Hypoglycémies nocturnes chez les patients diabétiques de type 1 : que pouvons-nous apprendre de la mesure de la glycémie en continu ? But : les hypoglycémies nocturnes sont une complication majeure du traitement des patients diabétiques de type 1; des autocontrôles de la glycémie capillaire sont donc recommandés pour les détecter. Cependant, la majorité des hypoglycémies nocturnes ne sont pas décelées par un autocontrôle glycémique durant la nuit. La mesure de la glycémie en continu (CGMS) est une alternative intéressante. Les buts de cette étude rétrospective étaient d'évaluer la véritable incidence des hypoglycémies nocturnes chez des patients diabétiques de type 1, la meilleure période pour effectuer un autocontrôle permettant de prédire une hypoglycémie nocturne, la relation entre les hyperglycémies matinales et les hypoglycémies nocturnes (phénomène de Somogyi) ainsi que l'utilité du CGMS pour réduire les hypoglycémies nocturnes. Méthode : quatre-vingt-huit patients diabétiques de type 1 qui avaient bénéficié d'un CGMS ont été inclus. Les indications au CGMS, les hypoglycémies nocturnes et diurnes ainsi que la corrélation entre les hypoglycémies nocturnes et les hyperglycémies matinales durant le CGMS ont été enregistrées. L'efficacité du CGMS pour réduire les hypoglycémies nocturnes a été évaluée six à neuf mois après. Résultats : la prévalence des hypoglycémies nocturnes était de 67% (32% non suspectées). La sensibilité d'une hypoglycémie à prédire une hypoglycémie nocturne était de 37% (OR = 2,37, P = 0,001) lorsqu'elle survient au coucher (22-24 h) et de 43% lorsqu'elle survient à 3 h (OR = 4,60, P < 0,001). Les hypoglycémies nocturnes n'étaient pas associées à des hyperglycémies matinales, mais à des hypoglycémies matinales (OR = 3.95, P < 0.001). Six à neuf mois après le CGMS, les suspicions cliniques d'hypoglycémies nocturnes ont diminué de 60% à 14% (P < 0.001). Abstract : Aim. - In type 1 diabetic patients (TIDM), nocturnal hypoglycaemias (Nlï) are a serious complication of T1DM treatment; self-monitoring of blood glucose (SMBG) is recommended to detect them. However, the majority of NH remains undetected on an occasional SMBG done during the night. An alternative strategy is the Continuous glucose monitoring (CGMS), which retrospectively shows the glycaemic profile. The aims of this retrospective study were to evaluate the true incidence of NH in TiDM, the bèst SMBG time to predict NH, the relationship between morning hyperglycaemia and N$ (Somogyi phenomenon) and the utility of CGMS to reduce NH. Methods. -Eighty-eight T1DM who underwent a CGMS exam were included. Indications for CGMS evaluarion, hypoglycaemias and correlation with morning hyperglycaemias were recorded. The efficiency of CGMS to reduce the suspected NH was evaluated after 6-9 months. Results. -The prevalence of NH was 67% (32% of them unsuspected). A measured hypoglycaemia at bedtime (22-24 h) had a sensitivity of 37% to detect NH (OR = 2.37, P = 0.001), while a single measure <_ 4 mmol/l at 3-hour had a sensitivity of 43% (OR = 4.60, P < 0.001). NH were not associated with morning hyperglycaemias but with morning hypoglycaemias (OR = 3.95, P < 0.001). After 6-9 months, suspicions of NH decreased from 60 to 14% (P < 0.001). Conclusion. - NH were highly prevalent and often undetected. SMBG at bedtime, which detected hypoglycaemia had sensitivity almost equal to that of 3-hour and should be preferred because it is easier to perform. Somogyi phenomenon was not observed. CGMS is useful to reduce the risk of NH in 75% of patients.
Resumo:
Self-measurement of blood pressure at home is increasingly used in the diagnostic and therapeutic approach of hypertension. This technique allows multiple measurements of blood pressure away from the clinical setting, making it possible to improve the evaluation of cardiovascular risk. Recently new guidelines on the use of self-measured blood pressure have been made available by the European Society of Hypertension, as summarized in the present paper.
Resumo:
OBJECTIVE: Incomplete compliance is one of several possible causes of uncontrolled hypertension. Yet, non-compliance remains largely unrecognized and is falsely interpreted as treatment resistance, because it is difficult to confirm or exclude objectively. The goal of this study was to evaluate the potential benefits of electronic monitoring of drug compliance in the management of patients with resistant hypertension. METHODS: Forty-one hypertensive patients resistant to a three-drug regimen (average blood pressure 156/ 106 +/- 23/11 mmHg, mean +/- SD) were studied prospectively. They were informed that for the next 2 months, their presently prescribed drugs would be provided in electronic monitors, without any change in treatment, so as to provide the treating physician with a measure of their compliance. Thereafter, patients were offered the possibility of prolonging the monitoring of compliance for another 2 month period, during which treatment was adapted if necessary. RESULTS: Monitoring of compliance alone was associated with a significant improvement of blood pressure at 2 months (145/97 +/- 20/15 mmHg, P < 0.01). During monitoring, blood pressure was normalized (systolic < 140 mmHg or diastolic < 90 mmHg) in one-third of the patients and insufficient compliance was unmasked in another 20%. When analysed according to tertiles of compliance, patients with the lowest compliance exhibited significantly higher achieved diastolic blood pressures (P = 0.04). In 30 patients, compliance was monitored up to 4 months and drug therapy was adapted whenever necessary. In these patients, a further significant decrease in blood pressure was obtained (from 150/100 +/- 18/15 to 143/94 +/- 22/11 mmHg, P = 0.04/0.02). CONCLUSIONS: These results suggest that objective monitoring of compliance using electronic devices may be a useful step in the management of patients with refractory hypertension, as it enables physicians to take rational decisions based on reliable and objective data of drug compliance and hence to improve blood pressure control.
Resumo:
Background: Management of febrile neutropenic episodes (FE) is challenged by lacking microbiological and clinical documentation of infection. We aimed at evaluating the utility of monitoring blood procalcitonin (PCT) in FE for initial diagnosis of infection and reassessment in persistent fever.Methods: PCT kinetics was prospectively monitored in 194 consecutive FE (1771 blood samples): 65 microbiologically documented infections (MDI, 33.5%; 49 due to non-coagulase-negative staphylococci, non-CNS), 68 clinically documented infections (CDI, 35%; 39 deep-seated), and 61 fever of unexplained origin (FUO, 31.5%).Results: At fever onset median PCT was 190 pg/mL (range 30-26'800), without significant difference among MDI, CDI and FUO. PCT peak occurred on day 2 after onset of fever: non-CNS-MDI/deep-seated-CDI (656, 80-86350) vs. FUO (205, 33-771; p<0.001). PCT >500 pg/mL distinguished non-CNS-MDI/deep-seated-CDI from FUO with 56% sensitivity and 90% specificity. PCT was >500 pg/ml in only 10% of FUO (688, 570-771). A PCT peak >500 pg/mL (1196, 524-11950) occurred beyond 3 days of persistent fever in 17/21 (81%) invasive fungal diseases (IFD). This late PCT peak identified IFD with 81% sensitivity and 57% specificity and preceded diagnosis according to EORTC-MSG criteria in 41% of cases. In IFD responding to therapy, median days to PCT <500 pg/mL and defervescence were 5 (1-23) vs. 10 (3-22; p = 0.026), respectively.Conclusion: While procalcitonin is not useful for diagnosis of infection at onset of neutropenic fever, it may help to distinguish a minority of potentially severe infections among FUOs on day 2 after onset of fever. In persistent fever monitoring procalcitonin contributes to early diagnosis and follow-up of invasive mycoses
Resumo:
Introduction: Within the framework of the «Programme cantonal Diabète», we aimed at collecting data to 1) describe the population of diabetic patients in the canton of Vaud, and 2) assess the quality of their care. Methods: A cross-sectional study was conducted in the fall of 2011. Out of 140 randomly selected community pharmacies registered in the canton of Vaud, 56 accepted to participate in patients' recruitment. Noninstitutionalized adult diabetic patients (disease duration >12 months) visiting a pharmacy with a prescription for oral anti-diabetic drugs, insulin, glycemic strips or glucose meter were eligible. Patients not residing in the canton of Vaud, not speaking and understanding French well enough, presenting obvious cognitive impairment, and women with gestational diabetes, were excluded. Using a self-administered questionnaire, data was collected on patients' characteristics and diabetes as well as various process (e.g. recommended annual screenings) and outcomes quality of care indicators. Descriptive analyses were performed. Results: A total of 406 patients with diabetes participated. Mean age was 64 years, 41% were women and 63% were married. Patients reported type 1, 2 and other types of diabetes in 13%, 69% and 19%, respectively. They were treated with oral anti-diabetic drugs, insulin or both in 50%, 23% and 27% of the cases. Half of the patients did not report any diabetes-related complication. Glucose self-monitoring was reported by 82% of the patients. Of those who were aware of HbA1C (n = 218), 98% reported at least one HbA1C control during the last 12 months. During that same time frame, 97% and 95% reported at least one blood pressure and weight measure, 94% reported having had a cholesterol check, 74%, 68% and 64% had eyes, feet and urine screening respectively. 62% of the patients had been immunized against influenza. At least 76% of the patients had a minimum of 5 of the 7 described process indicators performed during the last 12 months. Among patients who knew the value (n = 145), mean HbA1C was 7.4 (SD 1.2). Conclusion: This study targeting community-based diabetic patients shows that while routine clinical and laboratory tests were annually performed in the vast majority of patients, feet and urine screening, as well as influenza immunization, were less often reported by patients. The proportion of patients with diabetes having had at least 5 out of the 7 annual screenings performed was nevertheless very high.
Resumo:
Cet article présente les résultats de la revue systématique: Garcia-Alamino JM, Ward AM, Alonso-Coello P, et al. Self-monitoring and self-management of oral anticoagulation. Cochrane Database of Systematic Reviews 2010, Issue 4. Art. No. : CD003839. DOI: 10.1002/14651858.CD003839.pub2.. PMID: 20393937.
Resumo:
A passive sampling device called Monitor of NICotine or "MoNIC", was constructed and evaluated by IST laboratory for determining nicotine in Environmental Tobacco Smoke (ETS). Vapour nicotine was passively collected on a potassium bisulfate treated glass fibre filter as collection medium. Analysis of amount of nicotine on the treated filter by gas chromatography equipped with Thermoionic-Specific Detector (GCTSD) after liquid-liquid extraction of 1mL of 5N NaOH : 1 mL of n-heptane saturated with NH3 using quinoline as internal standard. Based on nicotine amount of 0.2 mg/cigarette as reference, the inhaled Cigarette Equivalents (CE) by non-smokers can be calculated. Using the detected CE on the badge for nonsmokers, and comparing with amount of nicotine and cotinine level in saliva of both smokers and exposed non-smokers (N=49), we can confirm the use of the CE concept for estimating exposure to ETS. The Valais CIPRET (Center of information and prevention of the addiction to smoking), is going to organize a big campaign on the subject of the passive addiction to smoking entitled "Smoked passive, we suffer from it, we die from it ". This campaign will take place in 2007 and has for objective to inform clearly the population of Valais of the dangerousness of the passive smoke. More than 1'500 MoNIC badges were gracefully distributed to Swiss population to perform a self-monitoring of population exposure level to ETS, expressed in term of CE. Non-stimulated saliva were also collected to determine ETS biomarkers nicotine/cotinine levels of participating volunteers. Preliminary results of different levels of CE in occupational and non-occupational situations in relation with ETS were presented in this study.
Resumo:
A passive sampling device called Monitor of NICotine or "MoNIC", was constructed and evaluated by IST laboratory for determining nicotine in Second Hand Tobacco Smoke (SHTS) or Environmental Tobacco Smoke (ETS). Vapour nicotine was passively collected on a potassium bisulfate treated glass fibre filter as collection medium. Analysis of collected nicotine on the treated filter by gas chromatography equipped with Thermoionic-Specific Detector (GC-TSD) after liquid-liquid extraction of 1mL of 5N NaOH : 1 mL of n-heptane saturated with NH3 using quinoline as internal standard. Based on nicotine amount of 0.2 mg/cigarette as the reference, the inhaled Cigarette Equivalents (CE) by non-smokers can be calculated. Using the detected CE on the badge for non-smokers, and comparing with amount of nicotine and cotinine level in saliva of both smokers and exposed non-smokers, we can confirm the use of the CE concept for estimating exposure to ETS. The regional CIPRET (Center of information and prevention of the addiction to smoking) of different cantons (Valais (VS), Vaud (VD), Neuchâtel (NE) and Fribourg (FR)) are going to organize a big campaign on the subject of the passive addiction to smoking. This campaign took place in 2007-2008 and has for objective to inform clearly the Swiss population of the dangerousness of the passive smoke. More than 3'900 MoNIC badges were gracefully distributed to Swiss population to perform a self-monitoring of population exposure level to ETS, expressed in term of CE. Non-stimulated saliva was also collected to determine ETS biomarkers nicotine/cotinine levels of participating volunteers. Results of different levels of CE in occupational and non-occupational situations in relation with ETS were presented in this study. This study, unique in Switzerland, has established a base map on the population's exposure to SHTS. It underscored the fact that all the Swiss people involved in this campaign (N=1241) is exposed to passive smoke, from <0.2 cig/d (10.8%), 1-2 to more than 10 cig/d (89.2%). In the area of high exposure (15-38 cig/d), are the most workers in public restaurant, cafe, bar, disco. By monitoring ETS tracer nicotine and its biomarkers, salivary nicotine and cotinine, it is demonstrated that the MoNIC badge can serve as indicator of CE passive smoking. The MoNIC badge, accompanied with content of salivary nicotine/cotinine can serve as a tool of evaluation of the ETS passive smoking and contributes to supply useful data for future epidemiological studies. It is also demonstrated that the salivary nicotine (without stimulation) is a better biomarker of ETS exposure than cotinine.
Resumo:
Cet article présente les résultats de la revue systématique: Garcia-Alamino JM, Ward AM, Alonso-Coello P, et al. Self-monitoring and self-management of oral anticoagulation. Cochrane Database of SystematicReviews 2010 Apr 14;(4):CD003839. doi:10.1002/14651858.CD003839.pub2.. PMID: 20393937.
Resumo:
The Learning Affect Monitor (LAM) is a new computer-based assessment system integrating basic dimensional evaluation and discrete description of affective states in daily life, based on an autonomous adapting system. Subjects evaluate their affective states according to a tridimensional space (valence and activation circumplex as well as global intensity) and then qualify it using up to 30 adjective descriptors chosen from a list. The system gradually adapts to the user, enabling the affect descriptors it presents to be increasingly relevant. An initial study with 51 subjects, using a 1 week time-sampling with 8 to 10 randomized signals per day, produced n = 2,813 records with good reliability measures (e.g., response rate of 88.8%, mean split-half reliability of .86), user acceptance, and usability. Multilevel analyses show circadian and hebdomadal patterns, and significant individual and situational variance components of the basic dimension evaluations. Validity analyses indicate sound assignment of qualitative affect descriptors in the bidimensional semantic space according to the circumplex model of basic affect dimensions. The LAM assessment module can be implemented on different platforms (palm, desk, mobile phone) and provides very rapid and meaningful data collection, preserving complex and interindividually comparable information in the domain of emotion and well-being.
Resumo:
OBJECTIVE: To reach a consensus on the clinical use of ambulatory blood pressure monitoring (ABPM). METHODS: A task force on the clinical use of ABPM wrote this overview in preparation for the Seventh International Consensus Conference (23-25 September 1999, Leuven, Belgium). This article was amended to account for opinions aired at the conference and to reflect the common ground reached in the discussions. POINTS OF CONSENSUS: The Riva Rocci/Korotkoff technique, although it is prone to error, is easy and cheap to perform and remains worldwide the standard procedure for measuring blood pressure. ABPM should be performed only with properly validated devices as an accessory to conventional measurement of blood pressure. Ambulatory recording of blood pressure requires considerable investment in equipment and training and its use for screening purposes cannot be recommended. ABPM is most useful for identifying patients with white-coat hypertension (WCH), also known as isolated clinic hypertension, which is arbitrarily defined as a clinic blood pressure of more than 140 mmHg systolic or 90 mmHg diastolic in a patient with daytime ambulatory blood pressure below 135 mmHg systolic and 85 mmHg diastolic. Some experts consider a daytime blood pressure below 130 mmHg systolic and 80 mmHg diastolic optimal. Whether WCH predisposes subjects to sustained hypertension remains debated. However, outcome is better correlated to the ambulatory blood pressure than it is to the conventional blood pressure. Antihypertensive drugs lower the clinic blood pressure in patients with WCH but not the ambulatory blood pressure, and also do not improve prognosis. Nevertheless, WCH should not be left unattended. If no previous cardiovascular complications are present, treatment could be limited to follow-up and hygienic measures, which should also account for risk factors other than hypertension. ABPM is superior to conventional measurement of blood pressure not only for selecting patients for antihypertensive drug treatment but also for assessing the effects both of non-pharmacological and of pharmacological therapy. The ambulatory blood pressure should be reduced by treatment to below the thresholds applied for diagnosing sustained hypertension. ABPM makes the diagnosis and treatment of nocturnal hypertension possible and is especially indicated for patients with borderline hypertension, the elderly, pregnant women, patients with treatment-resistant hypertension and patients with symptoms suggestive of hypotension. In centres with sufficient financial resources, ABPM could become part of the routine assessment of patients with clinic hypertension. For patients with WCH, it should be repeated at annual or 6-monthly intervals. Variation of blood pressure throughout the day can be monitored only by ABPM, but several advantages of the latter technique can also be obtained by self-measurement of blood pressure, a less expensive method that is probably better suited to primary practice and use in developing countries. CONCLUSIONS: ABPM or equivalent methods for tracing the white-coat effect should become part of the routine diagnostic and therapeutic procedures applied to treated and untreated patients with elevated clinic blood pressures. Results of long-term outcome trials should better establish the advantage of further integrating ABPM as an accessory to conventional sphygmomanometry into the routine care of hypertensive patients and should provide more definite information on the long-term cost-effectiveness. Because such trials are not likely to be funded by the pharmaceutical industry, governments and health insurance companies should take responsibility in this regard.
Resumo:
Self-measurement of blood pressure (SMBP) is increasingly used to assess blood pressure outside the medical setting. A prerequisite for the wide use of SMBP is the availability of validated devices providing reliable readings when they are handled by patients. This is the case today with a number of fully automated oscillometric apparatuses. A major advantage of SMBP is the great number of readings, which is linked with high reproducibility. Given these advantages, one of the major indications for SMBP is the need for evaluation of antihypertensive treatment, either for individual patients in everyday practice or in clinical trials intended to characterize the effects of blood-pressure-lowering medications. In fact, SMBP is particularly helpful for evaluating resistant hypertension and detecting white-coat effect in patients exhibiting high office blood pressure under antihypertensive therapy. SMBP might also motivate the patient and improve his or her adherence to long-term treatment. Moreover, SMBP can be used as a sensitive technique for evaluating the effect of antihypertensive drugs in clinical trials; it increases the power of comparative trials, allowing one to study fewer patients or to detect smaller differences in blood pressure than would be possible with the office measurement. Therefore, SMBP can be regarded as a valuable technique for the follow-up of treated patients as well as for the assessment of antihypertensive drugs in clinical trials.