143 resultados para Robotic education
em Université de Lausanne, Switzerland
Resumo:
BACKGROUND: Robot surgery is a further step towards new potential developments in minimally invasive surgery. Surgeons must keep abreast of these new technologies and learn their limits and possibilities. Robot-assisted laparoscopic cholecystectomy has not yet been performed in our institution. The purpose of this report is to present the pathway of implementation of robotic laparoscopic cholecystectomy in a university hospital. METHODS: The Zeus(R) robot system was used. Experimental training was performed on animals. The results of our experimental training allowed us to perform our first two clinical cases. RESULTS: Robot arm set-up and trocar placement required 53 and 35 minutes. Operative time were 59 and 45 minutes respectively. The overall operative time was 112 and 80 minutes, respectively. There were no intraoperative complications. Patients were discharged from the hospital after an overnight stay. CONCLUSION: Robotic laparoscopic cholecystectomy is safe and patient recovery similar to those of standard laparoscopy. At present, there are no advantages of robotic over conventional surgery. Nevertheless, robots have the potential to revolutionise the way surgery is performed. Robot surgery is not reserved for a happy few. This technology deserves more attention because it has the potential to change the way surgery is performed.
Resumo:
The academic activities led by the Unit of Community Pharmacy can be classified as translational. Our group is interested in person-centered pharmaceutical services aimed at a more responsible use of drugs (effectiveness, safety, efficiency) in collaboration with physicians and other health care professionals in a primary care setting. The following domains of education and research are high priorities for our group: medication therapy management, medication adherence, integrated care, individualization of therapies, care management for the elderly and e-health.
Resumo:
Prior research on school dropout has often focused on stable person- and institution-level variables. In this research, we investigate longitudinally perceived stress and optimism as predictors of dropout intentions over a period of four years, and distinguish between stable and temporary predictors of dropout intentions. Findings based on a nationally representative sample of 16e20 year-olds in Switzerland (N ¼ 4312) show that both average levels of stress and optimism as well as annually varying levels of stress and optimism affect dropout intentions. Additionally, results show that optimism buffers the negative impact of annually varying stress (i.e., years with more stress than usual), but not of stable levels of stress (i.e., stress over four years). The implications of the results are discussed according to a dynamic and preventive approach of school dropout.
Resumo:
Background: Sponsoring of physicians meetings by life science companies has led to reduced participation fees but might influence physician's prescription practices. A ban on such sponsoring may increase participation fees. We aimed to evaluate factors associated with physicians' willingness to pay for medical meetings, their position on the sponsoring of medical meetings and their opinion on alternative financing options. Methods: An anonymous web-based questionnaire was sent to 447 general practitioners in one state in Switzerland, identified through their affiliation to a medical association. The questionnaire evaluated physicians' willingness to pay for medical meetings, their perception of a bias in prescription practices induced by commercial support, their opinion on the introduction of a binding legislation and alternative financing options, their frequency of exchange with sales representatives and other relevant socioeconomic factors. We built a multivariate predictor logistic regression model to identify determinants of willingness to pay. Results: Of the 115 physicians who responded (response rate 26%), 48% were willing to pay more than what they currently pay for congresses, 79% disagreed that commercial support introduced a bias in their prescription practices and 61% disagreed that it introduced a bias in their colleagues' prescription practices. Based on the multivariate logistic regression, perception of a bias in peers prescription practices (OR=7.47, 95% CI 1.65-38.18) and group practice structure (OR=4.62, 95% CI 1.34-22.29) were significantly associated with an increase in willingness to pay. Two thirds (76%) of physicians did not support the introduction of a binding legislation and 53% were in favour of creating a general fund administered by an independent body. Conclusion: Our results suggest that almost half of physicians surveyed are willing to pay more than what they currently pay for congresses. Predictors of an increase in physicians' willingness to pay were perception of the influence of bias in peers prescription practices and group practice structure. Most responders did not agree that sponsoring introduced prescribing bias nor did they support the 2 introduction of a binding legislation prohibiting sponsoring but a majority did agree to an independent body that would centrally administer a general fund.
Resumo:
Introduction: In order to improve safety of pedicle screw placement several techniques have been developed. More recently robotically assisted pedicle insertion has been introduced aiming at increasing accuracy. The aim of this study was to compare this new technique with the two main pedicle insertion techniques in our unit namely fluoroscopically assisted vs EMG aided insertion. Material and methods: A total of 382 screws (78 thoracic,304 lumbar) were introduced in 64 patients (m/f = 1.37, equally distributed between insertion technique groups) by a single experienced spinal surgeon. From those, 64 (10 thoracic, 54 lumbar) were introduced in 11 patients using a miniature robotic device based on pre operative CT images under fluoroscopic control. 142 (4 thoracic, 138 lumbar) screws were introduced using lateral fluoroscopy in 27 patients while 176 (64 thoracic, 112 lumbar) screws in 26 patients were inserted using both fluoroscopy and EMG monitoring. There was no difference in the distribution of scoliotic spines between the 3 groups (n = 13). Screw position was assessed by an independent observer on CTs in axial, sagittal and coronal planes using the Rampersaud A to D classification. Data of lumbar and thoracic screws were processed separately as well as data obtained from axial, sagittal and coronal CT planes. Results: Intra- and interobserver reliability of the Rampersaud classification was moderate, (0.35 and 0.45 respectively) being the least good on axial plane. The total number of misplaced screws (C&D grades) was generally low (12 thoracic and 12 lumbar screws). Misplacement rates were same in straight and scoliotic spines. The only difference in misplacement rates was observed on axial and coronal images in the EMG assisted thoracic screw group with a higher proportion of C or D grades (p <0.05) in that group. Recorded compound muscle action potentials (CMAP) values of the inserted screws were 30.4 mA for the robot and 24.9mA for the freehand technique with a CI of 3.8 of the mean difference of 5.5 mA. Discussion: Robotic placement did improve the placement of thoracic screws but not that of lumbar screws possibly because our misplacement rates in general near that of published navigation series. Robotically assisted spine surgery might therefore enhance the safety of screw placement in particular in training settings were different users at various stages of their learning curve are involved in pedicle instrumentation.
Resumo:
Bone-mounted robotic guidance for pedicle screw placement has been recently introduced, aiming at increasing accuracy. The aim of this prospective study was to compare this novel approach with the conventional fluoroscopy assisted freehand technique (not the two- or three-dimensional fluoroscopy-based navigation). Two groups were compared: 11 patients, constituting the robotical group, were instrumented with 64 pedicle screws; 23 other patients, constituting the fluoroscopic group, were also instrumented with 64 pedicle screws. Screw position was assessed by two independent observers on postoperative CT-scans using the Rampersaud A to D classification. No neurological complications were noted. Grade A (totally within pedicle margins) accounted for 79% of the screws in the robotically assisted and for 83% of the screws in the fluoroscopic group respectively (p = 0.8). Grade C and D screws, considered as misplacements, accounted for 4.7% of all robotically inserted screws and 7.8% of the fluoroscopically inserted screws (p = 0.71). The current study did not allow to state that robotically assisted screw placement supersedes the conventional fluoroscopy assisted technique, although the literature is more optimistic about the former.
Resumo:
This manuscript has served for an oral presentation in honour of Professor Pierre Bovet who retired from his position as head physician at the Department of Psychiatry of the Lausanne University Hospital, Switzerland. Pierre Bovet has focused his clinical and scientific interest and his teaching activities on the schizophrenic spectrum disorders. The author tries to describe the essential elements of a clinical attitude which allows to really encounter the patient.