4 resultados para Residual-based tests

em Université de Lausanne, Switzerland


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: The determination of the carbon isotope ratio in androgen metabolites has been previously shown to be a reliable, direct method to detect testosterone misuse in the context of antidoping testing. Here, the variability in the 13C/12C ratios in urinary steroids in a widely heterogeneous cohort of professional soccer players residing in different countries (Argentina, Italy, Japan, South Africa, Switzerland and Uganda) is examined. METHODS: Carbon isotope ratios of selected androgens in urine specimens were determined using gas chromatography/combustion/isotope ratio mass spectrometry (GC-C-IRMS). RESULTS: Urinary steroids in Italian and Swiss populations were found to be enriched in 13C relative to other groups, reflecting higher consumption of C3 plants in these two countries. Importantly, detection criteria based on the difference in the carbon isotope ratio of androsterone and pregnanediol for each population were found to be well below the established threshold value for positive cases. CONCLUSIONS: The results obtained with the tested diet groups highlight the importance of adapting the criteria if one wishes to increase the sensitivity of exogenous testosterone detection. In addition, confirmatory tests might be rendered more efficient by combining isotope ratio mass spectrometry with refined interpretation criteria for positivity and subject-based profiling of steroids.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: Estimates of the left ventricular ejection fraction (LVEF) in patients with life-threatening ventricular arrhythmias related to coronary artery disease (CAD) have rarely been reported despite it has become the basis for determining patient's eligibility for prophylactic defibrillator. We aimed to determine the extent and distribution of reduced LVEF in patients with sustained ventricular tachycardia or ventricular fibrillation. METHODS AND RESULTS: 252 patients admitted for ventricular arrhythmia related to CAD were included: 149 had acute myocardial infarction (MI) (Group I, 59%), 54 had significant chronic obstructive CAD suggestive of an ischaemic arrhythmic trigger (Group II, 21%) and 49 patients had an old MI without residual ischaemia (Group III, 19%). 34% of the patients with scar-related arrhythmias had an LVEF > or =40%. Based on pre-event LVEF evaluation, it can be estimated that less than one quarter of the whole study population had a known chronic MI with severely reduced LVEF. In Group III, the proportion of inferior MI was significantly higher than anterior MI (81 vs. 19%; absolute difference, -62; 95% confidence interval, -45 to -79; P < or = 0.0001), though median LVEF was higher in inferior MI (0.37 +/- 10 vs. 0.29 +/- 10; P = 0.0499). CONCLUSION: Patients included in defibrillator trials represent only a minority of the patients at risk of sudden cardiac death. By applying the current risk stratification strategy based on LVEF, more than one third of the patients with old MI would not have qualified for a prophylactic defibrillator. Our study also suggests that inferior scars may be more prone to ventricular arrhythmia compared to anterior scars.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: In Switzerland, patients may undergo "blood tests" without being informed what these are screening for. Inadequate doctor-patient communication may result in patient misunderstanding. We examined what patients in the emergency department (ED) believed they had been screened for and explored their attitudes to routine (non-targeted) human immunodeficiency virus (HIV) screening. METHODS: Between 1st October 2012 and 28th February 2013, a questionnaire-based survey was conducted among patients aged 16-70 years old presenting to the ED of Lausanne University Hospital. Patients were asked: (1) if they believed they had been screened for HIV; (2) if they agreed in principle to routine HIV screening and (3) if they agreed to be HIV tested during their current ED visit. RESULTS: Of 466 eligible patients, 411 (88%) agreed to participate. Mean age was 46 ± 16 years; 192 patients (47%) were women; 366 (89%) were Swiss or European; 113 (27%) believed they had been screened for HIV, the proportion increasing with age (p ≤0.01), 297 (72%) agreed in principle with routine HIV testing in the ED, and 138 patients (34%) agreed to be HIV tested during their current ED visit. CONCLUSION: In this ED population, 27% believed incorrectly they had been screened for HIV. Over 70% agreed in principle with routine HIV testing and 34% agreed to be tested during their current visit. These results demonstrate willingness among patients concerning routine HIV testing in the ED and highlight a need for improved doctor-patient communication about what a blood test specifically screens for.