23 resultados para Recyclable materials

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biological materials are increasingly used in abdominal surgery for ventral, pelvic and perineal reconstructions, especially in contaminated fields. Future applications are multi-fold and include prevention and one-step closure of infected areas. This includes prevention of abdominal, parastomal and pelvic hernia, but could also include prevention of separation of multiple anastomoses, suture- or staple-lines. Further indications could be a containment of infected and/or inflammatory areas and protection of vital implants such as vascular grafts. Reinforcement patches of high-risk anastomoses or unresectable perforation sites are possibilities at least. Current applications are based mostly on case series and better data is urgently needed. Clinical benefits need to be assessed in prospective studies to provide reliable proof of efficacy with a sufficient follow-up. Only superior results compared with standard treatment will justify the higher costs of these materials. To date, the use of biological materials is not standard and applications should be limited to case-by-case decision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different embolic materials for portal vein embolization (PVE) were evaluated. Twenty pigs received left and median PVE. Hydrophilic phosphorylcholine, N-butyl cyanoacrylate, hydrophilic gel, and polyvinyl alcohol (PVA) particles measuring either 50-150 microm or 700-900 microm were used in five pigs each. Portography and portal vein pressure measurement were performed before, immediately after PVE, and before being euthanized at day 7. Tissue wedges from embolized, and non-embolized liver were obtained for pathology. After complete embolization, recanalization occurred at 7 days in one gel and one 700-900 PVA embolization. Post-PVE increase in portal pressure was found in all groups (p = 0.01). The area of the hepatic lobules in non-embolized liver was larger than in the embolized liver in all groups (p = 0.001). The ratios of the areas between non-embolized/embolized livers were 1.65, 2.19, 1.57, and 1.32 for gel, NBCA, 50-150 PVA and 700-900 PVA, respectively; the ratios of fibrosis between the embolized and non-embolized livers were 1.37, 3.01, 3.49, and 2.11 for gel, NBCA, 50-150 PVA and 700-900 PVA, respectively. Hepatic lobules in non-embolized liver were significantly larger with NBCA than in other groups (p = 0.01). Fibrosis in embolized liver was significantly higher for NBCA and 50-150 PVA (p = 0.002). The most severe changes in embolized and non-embolized liver were induced by 50-150 PVA and NCBA PVE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The proteasome plays an essential role in the production of MHC class I-restricted antigenic peptides. Recent results have indicated that several peptidases, including tripeptidyl peptidase II and puromycin-sensitive aminopeptidase, could act downstream of the proteasome by trimming NH(2)-terminal extensions of antigenic peptide precursors liberated by the proteasome. In this study, we have developed a solid-phase peptidase assay that allowed us to efficiently purify and immobilize proteasome, tripeptidyl peptidase II, and puromycin-sensitive aminopeptidase. Whereas the first peptidase was active against small fluorogenic peptides, the latter two could also digest antigenic peptide precursors and could be used repeatedly with different precursors. Using three distinct antigenic peptide precursors, we found that tripeptidyl peptidase II never cleaved within the antigenic peptide sequence, suggesting that, aside from its proteolytic activities, it may also play a role in protecting antigenic peptides from complete hydrolysis in the cytosol. This method should be valuable for high throughput screenings of substrate specificity and potential inhibitors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of two approaches for high-throughput, high-resolution X-ray phase contrast tomographic imaging being used at the tomographic microscopy and coherent radiology experiments (TOMCAT) beamline of the SLS is discussed and illustrated. Differential phase contrast (DPC) imaging, using a grating interferometer and a phase-stepping technique, is integrated into the beamline environment at TOMCAT in terms of the fast acquisition and reconstruction of data and the availability to scan samples within an aqueous environment. A second phase contrast method is a modified transfer of intensity approach that can yield the 3D distribution of the decrement of the refractive index of a weakly absorbing object from a single tomographic dataset. The two methods are complementary to one another: the DPC method is characterised by a higher sensitivity and by moderate resolution with larger samples; the modified transfer of intensity approach is particularly suited for small specimens when high resolution (around 1 mu m) is required. Both are being applied to investigations in the biological and materials science fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a phenomenologically motivated magneto-mechanically coupled finite strain elastic framework for simulating the curing process of polymers in the presence of a magnetic load is proposed. This approach is in line with previous works by Hossain and co-workers on finite strain curing modelling framework for the purely mechanical polymer curing (Hossain et al., 2009b). The proposed thermodynamically consistent approach is independent of any particular free energy function that may be used for the fully-cured magneto-sensitive polymer modelling, i.e. any phenomenological or micromechanical-inspired free energy can be inserted into the main modelling framework. For the fabrication of magneto-sensitive polymers, micron-size ferromagnetic particles are mixed with the liquid matrix material in the uncured stage. The particles align in a preferred direction with the application of a magnetic field during the curing process. The polymer curing process is a complex (visco) elastic process that transforms a fluid to a solid with time. Such transformation process is modelled by an appropriate constitutive relation which takes into account the temporal evolution of the material parameters appearing in a particular energy function. For demonstration in this work, a frequently used energy function is chosen, i.e. the classical Mooney-Rivlin free energy enhanced by coupling terms. Several representative numerical examples are demonstrated that prove the capability of our approach to correctly capture common features in polymers undergoing curing processes in the presence of a magneto-mechanical coupled load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dans les dernières années du 20ème siècle, l'aluminium a fait l'objet de beaucoup de communications outrancières et divergentes cautionnées par des scientifiques et des organismes faisant autorité. En 1986, la société PECHINEY le décrète perpétuel tel le mouvement « L'aluminium est éternel. Il est recyclable indéfiniment sans que ses propriétés soient altérées », ce qui nous avait alors irrité. Peu de temps après, en 1990, une communication tout aussi outrancière et irritante d'une grande organisation environnementale, le World Wild Fund, décrète que « le recyclage de l'aluminium est la pire menace pour l'environnement. Il doit être abandonné ». C'est ensuite à partir de la fin des années 1990, l'explosion des publications relatives au développement durable, le bien mal nommé. Au développement, synonyme de croissance obligatoire, nous préférons société ou organisation humaine et à durable, mauvaise traduction de l'anglais « sustainable », nous préférons supportable : idéalement, nous aurions souhaité parler de société durable, mais, pour être compris de tous, nous nous sommes limités à parler dorénavant de développement supportable. Pour l'essentiel, ces publications reconnaissent les très graves défauts de la métallurgie extractive de l'aluminium à partir du minerai et aussi les mérites extraordinaires du recyclage de l'aluminium puisqu'il représente moins de 10% de la consommation d'énergie de la métallurgie extractive à partir du minerai (on verra que c'est aussi moins de 10% de la pollution et du capital). C'est précisément sur le recyclage que se fondent les campagnes de promotion de l'emballage boisson, en Suisse en particulier. Cependant, les données concernant le recyclage de l'aluminium publiées par l'industrie de l'aluminium reflètent seulement en partie ces mérites. Dans les années 1970, les taux de croissance de la production recyclée sont devenus plus élevés que ceux de la production électrolytique. Par contre, les taux de recyclage, établis à indicateur identique, sont unanimement tous médiocres comparativement à d'autres matériaux tels le cuivre et le fer. Composante de l'industrie de l'aluminium, le recyclage bénéficie d'une image favorable auprès du grand public, démontrant le succès des campagnes de communication. A l'inverse, à l'intérieur de l'industrie de l'aluminium, c'est une image dévalorisée. Les opinions émises par tous les acteurs, commerçants, techniciens, dirigeants, encore recueillies pendant ce travail, sont les suivantes : métier de chiffonnier, métier misérable, métier peu technique mais très difficile (un recycleur 15 d'aluminium n'a-t-il pas dit que son métier était un métier d'homme alors que celui du recycleur de cuivre était un jeu d'enfant). A notre avis ces opinions appartiennent à un passé révolu qu'elles retraduisent cependant fidèlement car le recyclage est aujourd'hui reconnu comme une contribution majeure au développement supportable de l'aluminium. C'est bien pour cette raison que, en 2000, l'industrie de l'aluminium mondiale a décidé d'abandonner le qualificatif « secondaire » jusque là utilisé pour désigner le métal recyclé. C'est en raison de toutes ces données discordantes et parfois contradictoires qu'a débuté ce travail encouragé par de nombreuses personnalités. Notre engagement a été incontestablement facilité par notre connaissance des savoirs indispensables (métallurgie, économie, statistiques) et surtout notre expérience acquise au cours d'une vie professionnelle menée à l'échelle mondiale dans (recherche et développement, production), pour (recherche, développement, marketing, stratégie) et autour (marketing, stratégie de produits connexes, les ferro-alliages, et concurrents, le fer) de l'industrie de l'aluminium. Notre objectif est de faire la vérité sur le recyclage de l'aluminium, un matériau qui a très largement contribué à faire le 20ème siècle, grâce à une revue critique embrassant tous les aspects de cette activité méconnue ; ainsi il n'y a pas d'histoire du recyclage de l'aluminium alors qu'il est plus que centenaire. Plus qu'une simple compilation, cette revue critique a été conduite comme une enquête scientifique, technique, économique, historique, socio-écologique faisant ressortir les faits principaux ayant marqué l'évolution du recyclage de l'aluminium. Elle conclut sur l'état réel du recyclage, qui se révèle globalement satisfaisant avec ses forces et ses faiblesses, et au-delà du recyclage sur l'adéquation de l'aluminium au développement supportable, adéquation largement insuffisante. C'est pourquoi, elle suggère les thèmes d'études intéressant tous ceux scientifiques, techniciens, historiens, économistes, juristes concernés par une industrie très représentative de notre monde en devenir, un monde où la place de l'aluminium dépendra de son aptitude à satisfaire les critères du développement supportable. ABSTRACT Owing to recycling, the aluminium industry's global energetic and environmental prints are much lower than its ore extractive metallurgy's ones. Likewise, recycling will allow the complete use of the expected avalanche of old scraps, consequently to the dramatic explosion of aluminium consumption since the 50's. The recycling state is characterized by: i) raw materials split in two groups :one, the new scrap, internal and prompt, proportional to semi-finished and finished products quantities, exhibits a fairly good and regular quality. The other, the old scrap, proportional to the finished products arrivïng at their end-of--life, about 22 years later on an average, exhibits a variable quality depending on the collect mode. ii) a poor recycling rate, near by that of steel. The aluminium industry generates too much new internal scrap and doesn't collect all the availa~e old scrap. About 50% of it is not recycled (when steel is recycling about 70% of the old scrap flow). iii) recycling techniques, all based on melting, are well handled in spite of aluminium atiiníty to oxygen and the practical impossibility to purify aluminium from any impurity. Sorting and first collect are critical issues before melting. iv) products and markets of recycled aluminium :New scraps have still been recycled in the production lines from where there are coming (closed loop). Old scraps, mainly those mixed, have been first recycled in different production lines (open loop) :steel deoxidation products followed during the 30's, with the development of the foundry alloys, by foundry pieces of which the main market is the automotive industry. During the 80's, the commercial development of the beverage can in North America has permitted the first old scrap recycling closed loop which is developing. v) an economy with low and erratic margins because the electrolytic aluminium quotation fixes scrap purchasing price and recycled aluminium selling price. vi) an industrial organisation historically based on the scrap group and the loop mode. New scrap is recycled either by the transformation industry itself or by the recycling industry, the remelter, old scrap by the refiner, the other component of the recycling industry. The big companies, the "majors" are often involved in the closed loop recycling and very seldom in the open loop one. To-day, aluminium industry's global energetic and environmental prints are too unbeara~ e and the sustainaЫe development criteria are not fully met. Critical issues for the aluminium industry are to better produce, to better consume and to better recycle in order to become a real sustainaЫe development industry. Specific issues to recycling are a very efficient recycling industry, a "sustainaЫe development" economy, a complete old scrap collect favouring the closed loop. Also, indirectly connected to the recycling, are a very efficient transformation industry generating much less new scrap and a finished products industry delivering only products fulfilling sustainaЫe development criteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The use of bioabsorbable materials for orthopaedic useand traumatic fracture fixation in children has been poorly investigatedin the litterature and the effects on growing bones seem contradictory.The aim of the study is to compare the clinical and radiological resultsand evolution between bioabsorbable and traditional K-Wires for thetreatment of elbow epiphyseal fractures in children.Method: From jan. 2008 to Dec. 2009 21 children with similar fracturesand age were separated in two groups according to the way of fracturefixation: bioabsorbable K-Wire group and traditional K-Wire group.Follow-up was done at 3, 6 and 12 month post-operatively. Range ofmotion and elbow stability were measured for all patients. Theradiological evolution of the two groups were compared in term ofconsolidation, ossous resorption and radiolucencies. The clinicalresults were compared according to the Mayo Elbow Peformancescore. Controlateral elbow is compared with injured elbow in the twogroups.Results: In the bioabsorbable K-wire group, there were 10 children,including 5 girles and 5 boys with an average age of 9.5 years, rangingfrom 5 to 14 years. They were 7 external condylar fractures and3 epitrochlear fractures. In the traditional K-Wire group there were11 children, 2 girls and 9 boys with an average age of 7.6 years,ranging from 4 to 14 years. There were 10 external condylar fracturesand 1 epitrochlear fracture. At first follow up. The Mayo ElbowPerformance score was 93.8 (85-100 )for the bioabsorbable K-Wiregroup and 95.5 (85-100) for the traditional K-Wire group. In twochildren from the bioabsorbable K-Wire group there were transitoryradiolucencies along the wire tract on the x-ray, without clinicalmanifestation of it.We didn't see any premature closure of growingcartilage.Discussion: There is no significant differencies in term of clinical andradiological outcome between the two groups. The use ofbioabsorbable pins seems to be a good alternative to removabletraditional materials, avoiding a second operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare clinical and radiological outcome of lateral condyle fracture of the elbow in children treated with bioabsorbable or metallic material. From January 2008 to December 2009, 16 children with similar fractures and ages were grouped according to the fixation material used. Children were seen at 3, 6, and 12 months and more than 4 years (mean 51.8 months) postoperatively. The clinical results were compared using the Mayo Elbow Performance Score (MEPS). Radiographic studies of the fractured and opposite elbow were assessed at last follow-up control. Twelve children had a sufficient followup and could be included in the study. Seven could be included in the traditional group and 5 in the bioabsorbable group. At 12 months, the MEPS was 100 for every child in both groups. Asymptomatic bony radiolucent visible tracks and heterotopic ossifications were noted in both groups. There were no significant differences in terms of clinical and radiological outcome between the two groups. The use of bioabsorbable pins or screws is a reasonable alternative to the traditional use of metallic materials for the treatment of lateral condyle fracture of the elbow in children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: Wear of methacrylate artificial teeth resulting in vertical loss is a problem for both dentists and patients. PURPOSE: The purpose of this study was to quantify wear of artificial teeth in vivo and to relate it to subject and tooth variables. MATERIAL AND METHODS: Twenty-eight subjects treated with complete dentures received 2 artificial tooth materials (polymethyl methacrylate (PMMA)/double-cross linked PMMA fillers; 35%/59% (SR Antaris DCL, SR Postaris DCL); experimental 48%/46%). At baseline and after 12 months, impressions of the dentures were poured with improved stone. After laser scanning, the casts were superimposed and matched. Maximal vertical loss (mm) and volumetric loss (mm(3)) were calculated for each tooth and log-transformed to reduce variability. Volumetric loss was related to the occlusally active surface area. Linear mixed models were used to study the influence of the factors jaw, tooth, and material on adjusted (residual) wear values (alpha=.05). RESULTS: Due to drop outs (n=5) and unmatchable casts (n=3), 69% of all teeth were analyzed. Volumetric loss had a strong linear relationship to surface area (P<.001); this was less pronounced for vertical loss (P=.004). The factor showing the highest influence was the subject. Wear was tooth dependent (increasing from incisors to molars). However, these differences diminished once the wear rates were adjusted for occlusal area, and only a few remained significant (anterior versus posterior maxillary teeth). Another influencing factor was the age of the subject. CONCLUSIONS: Clinical wear of artificial teeth is higher than previously measured or expected. The presented method of analyzing wear of artificial teeth using a laser-scanning device seemed suitable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: (1) To evaluate the changes in surface roughness and gloss after simulated toothbrushing of 9 composite materials and 2 ceramic materials in relation to brushing time and load in vitro; (2) to assess the relationship between surface gloss and surface roughness. METHODS: Eight flat specimens of composite materials (microfilled: Adoro, Filtek Supreme, Heliomolar; microhybrid: Four Seasons, Tetric EvoCeram; hybrid: Compoglass F, Targis, Tetric Ceram; macrohybrid: Grandio), two ceramic materials (IPS d.SIGN and IPS Empress polished) were fabricated according to the manufacturer's instructions and optimally polished with up to 4000 grit SiC. The specimens were subjected to a toothbrushing (TB) simulation device (Willytec) with rotating movements, toothpaste slurry and at three different loads (100g/250g/350g). At hourly intervals from 1h to 10h TB, mean surface roughness Ra was measured with an optical sensor and the surface gloss (Gl) with a glossmeter. Statistical analysis was performed for log-transformed Ra data applying two-way ANOVA to evaluate the interaction between load and material and load and brushing time. RESULTS: There was a significant interaction between material and load as well as between load and brushing time (p<0.0001). The microhybrid and hybrid materials demonstrated more surface deterioration with higher loads, whereas with the microfilled resins Heliomolar and Adoro it was vice versa. For ceramic materials, no or little deterioration was observed over time and independent of the load. The ceramic materials and 3 of the composite materials (roughness) showed no further deterioration after 5h of toothbrushing. Mean surface gloss was the parameter which discriminated best between the materials, followed by mean surface roughness Ra. There was a strong correlation between surface gloss and surface roughness for all the materials except the ceramics. The evaluation of the deterioration curves of individual specimens revealed a more or less synchronous course suspecting hinting specific external conditions and not showing the true variability in relation to the tested material. SIGNIFICANCE: The surface roughness and gloss of dental materials changes with brushing time and load and thus results in different material rankings. Apart from Grandio, the hybrid composite resins were more prone to surface changes than microfilled composites. The deterioration potential of a composite material can be quickly assessed by measuring surface gloss. For this purpose, a brushing time of 10h (=72,000 strokes) is needed. In further comparative studies, specimens of different materials should be tested in one series to estimate the true variability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: There are only a few established artificial urinary sphincters for treatment of incontinence. We have developed a new device composed by three parts: the actuator, three contractile rings and a control unit. The actuator is made of Nitinol fibers, driven by microprocessor. The fibers are linked to the rings placed around the urethra. They function with alternance in their open and closed position. This concept is called piano concept. With this set-up, the constant compression on the urethra is strongly reduced. Methods: Six male sheep have been used for this study. The sphincter was open each hour for a period of 10 min., to guaranty urination. The bladder was filled with water while one cuff was closed and bladder pressure was monitored. The animals were sacrificed. Two biopsies around two cuffs of each explant and all three cuffs from each explant including urethra were analyzed. Urethra not surrounded by a cuff was taken as control. Results: The pressure exerted by the sphincter around the urethra provided continence. Simulated incontinence occurred at a pressure of 1bar measured on the bladder wall using a pressure probe. The closing force of the cuff was approx. 0·7N. No difference in tissue structure and organization of the urethra with and without artificial sphincter was observed. Conclusions: This device has several advantages compared to other urinary sphincters. It is easy to implant, has no hydraulic nature and reduces ischemic injury of the urethra by the alternance of urethral part compressed. Proof of concept in vivo has been demonstrated. Other studies are planned to determine long-term outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les fractures du condyle externe de l'enfant sont un traumatisme relativement fréquent qui survient le plus souvent chez l'enfant entre 5 et 15 ans. Elles sont classées en 3 grades : le grade 1 sans déplacement qui peuvent être traitées conservativement et les grades 2 (déplacées) et 3 (disloquées) qui nécessitent une prise en charge chirurgicale par réduction ouverte et embrochage. Le traitement traditionnel de ces fractures consistent en la mise en place de broches/vis métalliques qui doivent être retirées quelques semaines plus tard lors d'une seconde intervention. Depuis les années 90, des matériaux bio-résorbables à base d'acide polyglycoliques sont apparus en chirurgie orthopédique et traumatologique. En raison de la survenue de complications telles que réactions inflammatoires, formation de séromes ou ostéolyse, l'utilisation du matériel conventionnel a été préférée. Cependant, depuis quelques années, de nouveaux matériaux en acide polylactique sont apparus sur le marché. La période de résorption étant beaucoup plus lente, ces matériaux induisent des réactions beaucoup plus faibles, sans conséquences cliniques relevées jusqu'à présent. Chez l'adulte, de récentes études ont prouvés l'efficacité et l'absence d'effets secondaires liés à ces matériaux. Par contre, chez l'enfant, peu d'études à moyen terme ont été réalisées et l'impact sur l'os en croissance est peu connu, même si pour l'heure aucune conséquence clinique n'a été relevée. Dans le cadre de notre étude, nous avons comparé 2 groupes d'enfants traités pour des fractures du condyle externe du coude. Le premier groupe traité par du matériel conventionnel et le second par matériel résorbable. Les enfants ont tous étés suivis de manière très étroite durant la première année et la récupération clinique est similaire pour les 2 groupes. A 4 ans du traumatisme, les résultats fonctionnels sont identiques pour les 2 groupes et aucune complication liée au matériel résorbable n'a été mise en évidence. Par ailleurs, à 1 et 4 ans, les clichés radiologiques montrent l'absence de lésions liées au matériel résorbable. En conclusion, dans le cadre de notre travail nous avons pu montrer l'efficacité des matériaux résorbables dans la prise en charge des fractures du condyle externe du coude chez l'enfant. Ces matériaux permettent d'optimiser la prise en charge de ce type de fracture en prévenant un risque opératoire et anesthésique liés à une seconde intervention nécessaire au retrait du matériel d'ostéosynthèse conventionnel. Par ailleurs le coût lié à la prise en charge globale de ce type de fracture est moindre lors de l'utilisation de matériel résorbable.