9 resultados para Receiver-operating Characteristics

em Université de Lausanne, Switzerland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Metalworking fluid-associated hypersensitivity pneumonitis (MWF-HP) is a pulmonary disease caused by inhaling microorganisms present in the metalworking fluids used in the industrial sector. Mycobacterium immunogenum is the main etiological agent. Among the clinical, radiological and biological tools used for diagnosis, serological tests are important. The aim of this study was to identify immunogenic proteins in M. immunogenum and to use recombinant antigens for serological diagnosis of MWF-HP. Immunogenic proteins were detected by two-dimensional Western blot and candidate proteins were identified by mass spectrometry. Recombinant antigens were expressed in Escherichia coli and tested by enzyme-linked immunosorbent assay (ELISA) with the sera of 14 subjects with MWF-HP and 12 asymptomatic controls exposed to M. immunogenum. From the 350 spots visualized by two-dimensional gel electrophoresis with M. immunogenum extract, 6 immunogenic proteins were selected to be expressed as recombinant antigens. Acyl-CoA dehydrogenase antigen allowed for the best discrimination of MWF-HP cases against controls with an area under the receiver operating characteristics (ROC) curve of 0.930 (95% CI=0.820-1), a sensitivity of 100% and a specificity of 83% for the optimum threshold. Other recombinant antigens correspond to acyl-CoA dehydrogenase FadE, cytosol aminopeptidase, dihydrolipoyl dehydrogenase, serine hydroxymethyltransferase and superoxide dismutase. This is the first time that recombinant antigens have been used for the serodiagnosis of hypersensitivity pneumonitis. The availability of recombinant antigens makes it possible to develop standardized serological tests which in turn could simplify diagnosis, thus making it less invasive.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To develop predictive models for early triage of burn patients based on hypersusceptibility to repeated infections. BACKGROUND: Infection remains a major cause of mortality and morbidity after severe trauma, demanding new strategies to combat infections. Models for infection prediction are lacking. METHODS: Secondary analysis of 459 burn patients (≥16 years old) with 20% or more total body surface area burns recruited from 6 US burn centers. We compared blood transcriptomes with a 180-hour cutoff on the injury-to-transcriptome interval of 47 patients (≤1 infection episode) to those of 66 hypersusceptible patients [multiple (≥2) infection episodes (MIE)]. We used LASSO regression to select biomarkers and multivariate logistic regression to built models, accuracy of which were assessed by area under receiver operating characteristic curve (AUROC) and cross-validation. RESULTS: Three predictive models were developed using covariates of (1) clinical characteristics; (2) expression profiles of 14 genomic probes; (3) combining (1) and (2). The genomic and clinical models were highly predictive of MIE status [AUROCGenomic = 0.946 (95% CI: 0.906-0.986); AUROCClinical = 0.864 (CI: 0.794-0.933); AUROCGenomic/AUROCClinical P = 0.044]. Combined model has an increased AUROCCombined of 0.967 (CI: 0.940-0.993) compared with the individual models (AUROCCombined/AUROCClinical P = 0.0069). Hypersusceptible patients show early alterations in immune-related signaling pathways, epigenetic modulation, and chromatin remodeling. CONCLUSIONS: Early triage of burn patients more susceptible to infections can be made using clinical characteristics and/or genomic signatures. Genomic signature suggests new insights into the pathophysiology of hypersusceptibility to infection may lead to novel potential therapeutic or prophylactic targets.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIMS/HYPOTHESIS: Several susceptibility genes for type 2 diabetes have been discovered recently. Individually, these genes increase the disease risk only minimally. The goals of the present study were to determine, at the population level, the risk of diabetes in individuals who carry risk alleles within several susceptibility genes for the disease and the added value of this genetic information over the clinical predictors. METHODS: We constructed an additive genetic score using the most replicated single-nucleotide polymorphisms (SNPs) within 15 type 2 diabetes-susceptibility genes, weighting each SNP with its reported effect. We tested this score in the extensively phenotyped population-based cross-sectional CoLaus Study in Lausanne, Switzerland (n = 5,360), involving 356 diabetic individuals. RESULTS: The clinical predictors of prevalent diabetes were age, BMI, family history of diabetes, WHR, and triacylglycerol/HDL-cholesterol ratio. After adjustment for these variables, the risk of diabetes was 2.7 (95% CI 1.8-4.0, p = 0.000006) for individuals with a genetic score within the top quintile, compared with the bottom quintile. Adding the genetic score to the clinical covariates improved the area under the receiver operating characteristic curve slightly (from 0.86 to 0.87), yet significantly (p = 0.002). BMI was similar in these two extreme quintiles. CONCLUSIONS/INTERPRETATION: In this population, a simple weighted 15 SNP-based genetic score provides additional information over clinical predictors of prevalent diabetes. At this stage, however, the clinical benefit of this genetic information is limited.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The World Health Organization (WHO) criteria for the diagnosis of osteoporosis are mainly applicable for dual X-ray absorptiometry (DXA) measurements at the spine and hip levels. There is a growing demand for cheaper devices, free of ionizing radiation such as promising quantitative ultrasound (QUS). In common with many other countries, QUS measurements are increasingly used in Switzerland without adequate clinical guidelines. The T-score approach developed for DXA cannot be applied to QUS, although well-conducted prospective studies have shown that ultrasound could be a valuable predictor of fracture risk. As a consequence, an expert committee named the Swiss Quality Assurance Project (SQAP, for which the main mission is the establishment of quality assurance procedures for DXA and QUS in Switzerland) was mandated by the Swiss Association Against Osteoporosis (ASCO) in 2000 to propose operational clinical recommendations for the use of QUS in the management of osteoporosis for two QUS devices sold in Switzerland. Device-specific weighted "T-score" based on the risk of osteoporotic hip fractures as well as on the prediction of DXA osteoporosis at the hip, according to the WHO definition of osteoporosis, were calculated for the Achilles (Lunar, General Electric, Madison, Wis.) and Sahara (Hologic, Waltham, Mass.) ultrasound devices. Several studies (totaling a few thousand subjects) were used to calculate age-adjusted odd ratios (OR) and area under the receiver operating curve (AUC) for the prediction of osteoporotic fracture (taking into account a weighting score depending on the design of the study involved in the calculation). The ORs were 2.4 (1.9-3.2) and AUC 0.72 (0.66-0.77), respectively, for the Achilles, and 2.3 (1.7-3.1) and 0.75 (0.68-0.82), respectively, for the Sahara device. To translate risk estimates into thresholds for clinical application, 90% sensitivity was used to define low fracture and low osteoporosis risk, and a specificity of 80% was used to define subjects as being at high risk of fracture or having osteoporosis at the hip. From the combination of the fracture model with the hip DXA osteoporotic model, we found a T-score threshold of -1.2 and -2.5 for the stiffness (Achilles) determining, respectively, the low- and high-risk subjects. Similarly, we found a T-score at -1.0 and -2.2 for the QUI index (Sahara). Then a screening strategy combining QUS, DXA, and clinical factors for the identification of women needing treatment was proposed. The application of this approach will help to minimize the inappropriate use of QUS from which the whole field currently suffers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: The presence of multiple melanocytic naevi is a strong risk factor for melanoma. Use of the whole body naevus count to identify at-risk patients is impractical. OBJECTIVES: To (i) identify a valid anatomical predictor of total naevus count; (ii) determine the number of naevi that most accurately predict total naevus count above 25, 50 and 100; and (iii) evaluate determinants of multiple melanocytic naevi and atypical naevi. METHODS: Clinical data from 292 consecutive Spanish patients consulting for skin lesions requiring debriding were collected throughout 2009 and 2010. Correlations between site-specific and whole body naevus counts were analysed. Cut-offs to predict total naevus counts were determined using the area under the receiver operating characteristic curve. RESULTS: The studied population was young (median age 31 years, interquartile range 28-43). The naevus count on the right arm correlated best with the total nevus count (R(2) 0·80 for men, 0·86 for women). Presence of at least five naevi on the right arm was the strongest determinant of a total naevus count above 50 [odds ratio (OR) 34·4, 95% confidence interval (CI) 13·9-85·0] and of having at least one atypical naevus (OR 5·7, 95% CI 2·4-13·5). Cut-off values of 6, 8 and 11 naevi on the right arm best predicted total naevus count above 25, 50 and 100, respectively. CONCLUSIONS: Our results support the arm as a practical and reliable site to estimate the total naevus count when screening or phenotyping large populations. Threshold values for the number of naevi on the arm are proposed to help identify patients for melanoma screening.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Multiple risk prediction models have been validated in all-age patients presenting with acute coronary syndrome (ACS) and treated with percutaneous coronary intervention (PCI); however, they have not been validated specifically in the elderly. METHODS: We calculated the GRACE (Global Registry of Acute Coronary Events) score, the logistic EuroSCORE, the AMIS (Acute Myocardial Infarction Swiss registry) score, and the SYNTAX (Synergy between Percutaneous Coronary Intervention with TAXUS and Cardiac Surgery) score in a consecutive series of 114 patients ≥75 years presenting with ACS and treated with PCI within 24 hours of hospital admission. Patients were stratified according to score tertiles and analysed retrospectively by comparing the lower/mid tertiles as an aggregate group with the higher tertile group. The primary endpoint was 30-day mortality. Secondary endpoints were the composite of death and major adverse cardiovascular events (MACE) at 30 days, and 1-year MACE-free survival. Model discrimination ability was assessed using the area under receiver operating characteristic curve (AUC). RESULTS: Thirty-day mortality was higher in the upper tertile compared with the aggregate lower/mid tertiles according to the logistic EuroSCORE (42% vs 5%; odds ratio [OR] = 14, 95% confidence interval [CI] = 4-48; p <0.001; AUC = 0.79), the GRACE score (40% vs 4%; OR = 17, 95% CI = 4-64; p <0.001; AUC = 0.80), the AMIS score (40% vs 4%; OR = 16, 95% CI = 4-63; p <0.001; AUC = 0.80), and the SYNTAX score (37% vs 5%; OR = 11, 95% CI = 3-37; p <0.001; AUC = 0.77). CONCLUSIONS: In elderly patients presenting with ACS and referred to PCI within 24 hours of admission, the GRACE score, the EuroSCORE, the AMIS score, and the SYNTAX score predicted 30 day mortality. The predictive value of clinical scores was improved by using them in combination.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The Geneva Prognostic Score (GPS), the Pulmonary Embolism Severity Index (PESI), and its simplified version (sPESI) are well known clinical prognostic scores for pulmonary embolism (PE).Objectives: To compare the prognostic performance of these scores in elderly patients with PE. Patients/Methods: In a multicenter Swiss cohort of elderly patients with venous thromboembolism, we prospectively studied 449 patients aged ≥65 years with symptomatic PE. The outcome was 30-day overall mortality. We dichotomized patients as low- vs. higher-risk in all three scores using the following thresholds: GPS scores ≤2 vs. >2, PESI risk classes I-II vs. III-V, and sPESI scores 0 vs. ≥1. We compared 30-day mortality in low- vs. higher-risk patients and the areas under the receiver operating characteristic curve (ROC). Results: Overall, 3.8% of patients (17/449) died within 30 days. The GPS classified a greater proportion of patients as low risk (92% [413/449]) than the PESI (36.3% [163/449]) and the sPESI (39.6% [178/449]) (P<0.001 for each comparison). Low-risk patients based on the sPESI had a mortality of 0% (95% confidence interval [CI] 0-2.1%) compared to 0.6% (95% CI 0-3.4%) for low-risk patients based on the PESI and 3.4% (95% CI 1.9-5.6%) for low-risk patients based on the GPS. The areas under the ROC curves were 0.77 (95%CI 0.72-0.81), 0.76 (95% CI 0.72-0.80), and 0.71 (95% CI 0.66-0.75), respectively (P=0.47). Conclusions: In this cohort of elderly patients with PE, the GPS identified a higher proportion of patients as low-risk but the PESI and sPESI were more accurate in predicting mortality.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The updated Vienna Prediction Model for estimating recurrence risk after an unprovoked venous thromboembolism (VTE) has been developed to identify individuals at low risk for VTE recurrence in whom anticoagulation (AC) therapy may be stopped after 3 months. We externally validated the accuracy of the model to predict recurrent VTE in a prospective multicenter cohort of 156 patients aged ≥65 years with acute symptomatic unprovoked VTE who had received 3 to 12 months of AC. Patients with a predicted 12-month risk within the lowest quartile based on the updated Vienna Prediction Model were classified as low risk. The risk of recurrent VTE did not differ between low- vs higher-risk patients at 12 months (13% vs 10%; P = .77) and 24 months (15% vs 17%; P = 1.0). The area under the receiver operating characteristic curve for predicting VTE recurrence was 0.39 (95% confidence interval [CI], 0.25-0.52) at 12 months and 0.43 (95% CI, 0.31-0.54) at 24 months. In conclusion, in elderly patients with unprovoked VTE who have stopped AC, the updated Vienna Prediction Model does not discriminate between patients who develop recurrent VTE and those who do not. This study was registered at www.clinicaltrials.gov as #NCT00973596.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three-dimensional segmented echo planar imaging (3D-EPI) is a promising approach for high-resolution functional magnetic resonance imaging, as it provides an increased signal-to-noise ratio (SNR) at similar temporal resolution to traditional multislice 2D-EPI readouts. Recently, the 3D-EPI technique has become more frequently used and it is important to better understand its implications for fMRI. In this study, the temporal SNR characteristics of 3D-EPI with varying numbers of segments are studied. It is shown that, in humans, the temporal variance increases with the number of segments used to form the EPI acquisition and that for segmented acquisitions, the maximum available temporal SNR is reduced compared to single shot acquisitions. This reduction with increased segmentation is not found in phantom data and thus likely due to physiological processes. When operating in the thermal noise dominated regime, fMRI experiments with a motor task revealed that the 3D variant outperforms the 2D-EPI in terms of temporal SNR and sensitivity to detect activated brain regions. Thus, the theoretical SNR advantage of a segmented 3D-EPI sequence for fMRI only exists in a low SNR situation. However, other advantages of 3D-EPI, such as the application of parallel imaging techniques in two dimensions and the low specific absorption rate requirements, may encourage the use of the 3D-EPI sequence for fMRI in situations with higher SNR.