64 resultados para Random coefficient multinomial logit
em Université de Lausanne, Switzerland
Resumo:
Objectives To prospectively assess respiratory health in wastewater workers and garbage collectors over 5 years. Methods Exposure, respiratory symptoms and conditions, spirometry and lung-specific proteins were assessed yearly in a cohort of 304 controls, 247 wastewater workers and 52 garbage collectors. Results were analysed with random coefficient models and linear regression taking into account several potential confounders. Results Symptoms, spirometry and lung-specific proteins were not affected by occupational exposure. Conclusions In this population no effects of occupational exposure to bioaerosols were found, probably because of good working conditions.
Resumo:
OBJECTIVE: We examined the correlation between clinical wear rates of restorative materials and enamel (TRAC Research Foundation, Provo, USA) and the results of six laboratory test methods (ACTA, Alabama (generalized, localized), Ivoclar (vertical, volumetric), Munich, OHSU (abrasion, attrition), Zurich). METHODS: Individual clinical wear data were available from clinical trials that were conducted by TRAC Research Foundation (formerly CRA) together with general practitioners. For each of the n=28 materials (21 composite resins for intra-coronal restorations [20 direct and 1 indirect], 5 resin materials for crowns, 1 amalgam, enamel) a minimum of 30 restorations had been placed in posterior teeth, mainly molars. The recall intervals were up to 5 years with the majority of materials (n=27) being monitored, however, only for up to 2 years. For the laboratory data, the databases MEDLINE and IADR abstracts were searched for wear data on materials which were also clinically tested by TRAC Research Foundation. Only those data for which the same test parameters (e.g. number of cycles, loading force, type of antagonist) had been published were included in the study. A different quantity of data was available for each laboratory method: Ivoclar (n=22), Zurich (n=20), Alabama (n=17), OHSU and ACTA (n=12), Munich (n=7). The clinical results were summed up in an index and a linear mixed model was fitted to the log wear measurements including the following factors: material, time (0.5, 1, 2 and 3 years), tooth (premolar/molar) and gender (male/female) as fixed effects, and patient as random effect. Relative ranks were created for each material and method; the same was performed with the clinical results. RESULTS: The mean age of the subjects was 40 (±12) years. The materials had been mostly applied in molars (81%) and 95% of the intracoronal restorations were Class II restorations. The mean number of individual wear data per material was 25 (range 14-42). The mean coefficient of variation of clinical wear data was 53%. The only significant correlation was reached by OHSU (abrasion) with a Spearman r of 0.86 (p=0.001). Zurich, ACTA, Alabama generalized wear and Ivoclar (volume) had correlation coefficients between 0.3 and 0.4. For Zurich, Alabama generalized wear and Munich, the correlation coefficient improved if only composites for direct use were taken into consideration. The combination of different laboratory methods did not significantly improve the correlation. SIGNIFICANCE: The clinical wear of composite resins is mainly dependent on differences between patients and less on the differences between materials. Laboratory methods to test conventional resins for wear are therefore less important, especially since most of them do not reflect the clinical wear.
Resumo:
Mitochondrial (M) and lipid droplet (L) volume density (vd) are often used in exercise research. Vd is the volume of muscle occupied by M and L. The means of calculating these percents are accomplished by applying a grid to a 2D image taken with transmission electron microscopy; however, it is not known which grid best predicts these values. PURPOSE: To determine the grid with the least variability of Mvd and Lvd in human skeletal muscle. METHODS: Muscle biopsies were taken from vastus lateralis of 10 healthy adults, trained (N=6) and untrained (N=4). Samples of 5-10mg were fixed in 2.5% glutaraldehyde and embedded in EPON. Longitudinal sections of 60 nm were cut and 20 images were taken at random at 33,000x magnification. Vd was calculated as the number of times M or L touched two intersecting grid lines (called a point) divided by the total number of points using 3 different sizes of grids with squares of 1000x1000nm sides (corresponding to 1µm2), 500x500nm (0.25µm2) and 250x250nm (0.0625µm2). Statistics included coefficient of variation (CV), 1 way-BS ANOVA and spearman correlations. RESULTS: Mean age was 67 ± 4 yo, mean VO2peak 2.29 ± 0.70 L/min and mean BMI 25.1 ± 3.7 kg/m2. Mean Mvd was 6.39% ± 0.71 for the 1000nm squares, 6.01% ± 0.70 for the 500nm and 6.37% ± 0.80 for the 250nm. Lvd was 1.28% ± 0.03 for the 1000nm, 1.41% ± 0.02 for the 500nm and 1.38% ± 0.02 for the 250nm. The mean CV of the three grids was 6.65% ±1.15 for Mvd with no significant differences between grids (P>0.05). Mean CV for Lvd was 13.83% ± 3.51, with a significant difference between the 1000nm squares and the two other grids (P<0.05). The 500nm squares grid showed the least variability between subjects. Mvd showed a positive correlation with VO2peak (r = 0.89, p < 0.05) but not with weight, height, or age. No correlations were found with Lvd. CONCLUSION: Different size grids have different variability in assessing skeletal muscle Mvd and Lvd. The grid size of 500x500nm (240 points) was more reliable than 1000x1000nm (56 points). 250x250nm (1023 points) did not show better reliability compared with the 500x500nm, but was more time consuming. Thus, choosing a grid with square size of 500x500nm seems the best option. This is particularly relevant as most grids used in the literature are either 100 points or 400 points without clear information on their square size.
Resumo:
This article analyses stability and volatility of party preferences using data from the Swiss Household-Panel (SHP), which, for the first time, allow studying transitions and stability of voters over several years in Switzerland. Analyses cover the years 1999- 2007 and systematically distinguish changes between party blocks and changes within party blocks. The first part looks at different patterns of change, which show relatively high volatility. The second part tests several theories on causes of such changes applying a multinomial random-effects model. Results show that party preferences stabilise with their duration and with age and that the electoral cycle, political sophistication, socio-structural predispositions, the household-context as well as party size and the number of parties each explain part of electoral volatility. Different results for withinand between party-block changes underlie the importance of that differentiation.
Resumo:
The sedimentation coefficient of a secretory IgA found in bovine colostrum and saliva is compared with that of IgG and IgM from the same colostrum. The IgA fraction gives a value of 10.8 S, whereas the major part of the IgG has a value of 7.1 S and the IgM 19.2 S. The sedimentation coefficient of the free secretory piece has also been determined: its value is 4.95 S.
Resumo:
Random mating is the null model central to population genetics. One assumption behind random mating is that individuals mate an infinite number of times. This is obviously unrealistic. Here we show that when each female mates a finite number of times, the effective size of the population is substantially decreased.
Resumo:
In this paper, we study the average crossing number of equilateral random walks and polygons. We show that the mean average crossing number ACN of all equilateral random walks of length n is of the form . A similar result holds for equilateral random polygons. These results are confirmed by our numerical studies. Furthermore, our numerical studies indicate that when random polygons of length n are divided into individual knot types, the for each knot type can be described by a function of the form where a, b and c are constants depending on and n0 is the minimal number of segments required to form . The profiles diverge from each other, with more complex knots showing higher than less complex knots. Moreover, the profiles intersect with the ACN profile of all closed walks. These points of intersection define the equilibrium length of , i.e., the chain length at which a statistical ensemble of configurations with given knot type -upon cutting, equilibration and reclosure to a new knot type -does not show a tendency to increase or decrease . This concept of equilibrium length seems to be universal, and applies also to other length-dependent observables for random knots, such as the mean radius of gyration Rg.
Resumo:
The greenhead ant Rhytidoponera metallica has long been recognized as posing a potential challenge to kin selection theory because it has large queenless colonies where apparently many of the morphological workers are mated and reproducing. However this species has never been studied genetically and important elements of its breeding system and kin structure remain uncertain. We used microsatellite markers to measure the relatedness among nestmates unravel the fine-scale population genetic structure and infer the breeding system of R. metallica. The genetic relatedness among worker nestmates is very low but significantly greater than zero (r = 0.082 +/- 0.015) which demonstrates that nests contain many distantly related breeders. The inbreeding coefficient is very close to and not significantly different from zero indicating random mating and lack of microgeographic genetic differentiation. On average. closely located nests are not more similar genetically than distant nests which is surprising as new colonies form by budding and female dispersal is restricted. Lack of inbreeding and absence of population viscosity indicates high gene flow mediated by males. Overall the genetic pattern detected in R. metallica suggests that a high number of moderately related workers mate with unrelated males from distant nests. This breeding system results in the lowest relatedness among nestmates reported for social insect species where breeders and helpers are not morphologically differentiated. [References: 69]
Resumo:
OBJECTIVE: To determine the psychometric properties of an adapted version of the Falls Efficacy Scale (FES) in older rehabilitation patients. DESIGN: Cross-sectional survey. SETTING: Postacute rehabilitation facility in Switzerland. PARTICIPANTS: Seventy elderly persons aged 65 years and older receiving postacute, inpatient rehabilitation. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: FES questions asked about subject's confidence (range, 0 [none]-10 [full]) in performing 12 activities of daily living (ADLs) without falling. Construct validity was assessed using correlation with measures of physical (basic ADLs [BADLs]), cognitive (Mini-Mental State Examination [MMSE]), affective (15-item Geriatric Depression Scale [GDS]), and mobility (Performance Oriented Mobility Assessment [POMA]) performance. Predictive validity was assessed using the length of rehabilitation stay as the outcome. To determine test-retest reliability, FES administration was repeated in a random subsample (n=20) within 72 hours. RESULTS: FES scores ranged from 10 to 120 (mean, 88.7+/-26.5). Internal consistency was optimal (Cronbach alpha=.90), and item-to-total correlations were all significant, ranging from .56 (toilet use) to .82 (reaching into closets). Test-retest reliability was high (intraclass correlation coefficient, .97; 95% confidence interval, .95-.99; P<.001). Subjects reporting a fall in the previous year had lower FES scores than nonfallers (85.0+/-25.2 vs 94.4+/-27.9, P=.054). The FES correlated with POMA (Spearman rho=.40, P<.001), MMSE (rho=.37, P=.001), BADL (rho=.43, P<.001), and GDS (rho=-.53, P<.001) scores. These relationships remained significant in multivariable analysis for BADLs and GDS, confirming FES construct validity. There was a significant inverse relationship between FES score and the length of rehabilitation stay, independent of sociodemographic, functional, cognitive, and fall status. CONCLUSIONS: This adapted FES is reliable and valid in older patients undergoing postacute rehabilitation. The independent association between poor falls efficacy and increased length of stay has not been previously described and needs further investigations.
Resumo:
Analyzing the relationship between the baseline value and subsequent change of a continuous variable is a frequent matter of inquiry in cohort studies. These analyses are surprisingly complex, particularly if only two waves of data are available. It is unclear for non-biostatisticians where the complexity of this analysis lies and which statistical method is adequate.With the help of simulated longitudinal data of body mass index in children,we review statistical methods for the analysis of the association between the baseline value and subsequent change, assuming linear growth with time. Key issues in such analyses are mathematical coupling, measurement error, variability of change between individuals, and regression to the mean. Ideally, it is better to rely on multiple repeated measurements at different times and a linear random effects model is a standard approach if more than two waves of data are available. If only two waves of data are available, our simulations show that Blomqvist's method - which consists in adjusting for measurement error variance the estimated regression coefficient of observed change on baseline value - provides accurate estimates. The adequacy of the methods to assess the relationship between the baseline value and subsequent change depends on the number of data waves, the availability of information on measurement error, and the variability of change between individuals.
Resumo:
Although the relationship between serum uric acid (SUA) and adiposity is well established, the direction of the causality is still unclear in the presence of conflicting evidences. We used a bidirectional Mendelian randomization approach to explore the nature and direction of causality between SUA and adiposity in a population-based study of Caucasians aged 35 to 75 years. We used, as instrumental variables, rs6855911 within the SUA gene SLC2A9 in one direction, and combinations of SNPs within the adiposity genes FTO, MC4R and TMEM18 in the other direction. Adiposity markers included weight, body mass index, waist circumference and fat mass. We applied a two-stage least squares regression: a regression of SUA/adiposity markers on our instruments in the first stage and a regression of the response of interest on the fitted values from the first stage regression in the second stage. SUA explained by the SLC2A9 instrument was not associated to fat mass (regression coefficient [95% confidence interval]: 0.05 [-0.10, 0.19] for fat mass) contrasting with the ordinary least square estimate (0.37 [0.34, 0.40]). By contrast, fat mass explained by genetic variants of the FTO, MC4R and TMEM18 genes was positively and significantly associated to SUA (0.31 [0.01, 0.62]), similar to the ordinary least square estimate (0.27 [0.25, 0.29]). Results were similar for the other adiposity markers. Using a bidirectional Mendelian randomization approach in adult Caucasians, our findings suggest that elevated SUA is a consequence rather than a cause of adiposity.
Resumo:
Objectifs : Le coefficient de diffusion apparente (ADC) est utilisé pour le suivi des lésions hépatiques malignes traitées. Cependant, l'ADC est généralement mesuré dans la lésion entière, alors que cela devrait être réalisé dans la zone la plus restreinte (ZLPR), cette dernière représentant potentiellement du résidu tumoral. Notre objectif était d'évaluer la variabilité inter/intraobservateur de l'ADC dans la tumeur entière et dans la ZLPR. Matériels et méthodes : Quarante patients traités par chimioembolisation ou radiofréquence ont été évalués. Après consensus, deux lecteurs ont indépendamment mesuré l'ADC de la lésion entière et de la ZLPR. Les mêmes mesures ont été répétées deux semaines plus tard. Le test de Spearman et la méthode de Bland-Altman ont été utilisées. Résultats : La corrélation interobservateur de l'ADC dans la lésion entière et dans la ZLPR était de 0,962 et de 0,884. La corrélation intraobservateur était de 0,992 et de 0,979, respectivement. Les limites de variabilité interobservateur (mm2/sec*10 - 3) étaient entre -0,25/+0,28 dans la lésion entière et entre -0,51/+0,46 dans la ZLPR. Les limites de variabilité intraobservateur étaient respectivement : -0,25/+0,24 et -0,43/+0,47. Conclusion : La corrélation inter/intraobservateur dans les mesures d'ADC est bonne. Toutefois, une variabilité limitée existe et doit être considérée lors de l'interprétation des valeurs d'ADC des tumeurs hépatiques.