In this investigation, high-resolution, 1x1x1-mm(3) functional magnetic resonance imaging (fMRI) at 7 T is performed using a multichannel array head coil and a surface coil approach. Scan geometry was optimized for each coil separately to exploit the strengths of both coils. Acquisitions with the surface coil focused on partial brain coverage, while whole-brain coverage fMRI experiments were performed with the array head coil. BOLD sensitivity in the occipital lobe was found to be higher with the surface coil than with the head array, suggesting that restriction of signal detection to the area of interest may be beneficial for localized activation studies. Performing independent component analysis (ICA) decomposition of the fMRI data, we consistently detected BOLD signal changes and resting state networks. In the surface coil data, a small negative BOLD response could be detected in these resting state network areas. Also in the data acquired with the surface coil, two distinct components of the positive BOLD signal were consistently observed. These two components were tentatively assigned to tissue and venous signal changes.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: Multinuclear magnetic resonance spectroscopy and imaging require a radiofrequency probe capable of transmitting and receiving at the proton and non-proton frequencies. To minimize coupling between probe elements tuned to different frequencies, LC (inductor-capacitor) traps blocking current at the (1) H frequency can be inserted in non-proton elements. This work compares LC traps with LCC traps, a modified design incorporating an additional capacitor, enabling control of the trap reactance at the low frequency while maintaining (1) H blocking. METHODS: Losses introduced by both types of trap were analysed using circuit models. Radiofrequency coils incorporating a series of LC and LCC traps were then built and evaluated at the bench. LCC trap performance was then confirmed using (1) H and (13) C measurements in a 7T human scanner. RESULTS: LC and LCC traps both effectively block interaction between non-proton and proton coils at the proton frequency. LCC traps were found to introduce a sensitivity reduction of 5±2%, which was less than half of that caused by LC traps. CONCLUSION: Sensitivity of non-proton coils is critical. The improved trap design, incorporating one extra capacitor, significantly reduces losses introduced by the trap in the non-proton coil. Magn Reson Med 72:584-590, 2014. © 2013 Wiley Periodicals, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Seven tesla (T) MR imaging is potentially promising for the morphologic evaluation of coronary arteries because of the increased signal-to-noise ratio compared to lower field strengths, in turn allowing improved spatial resolution, improved temporal resolution, or reduced scanning times. However, there are a large number of technical challenges, including the commercial 7 T systems not being equipped with homogeneous body radiofrequency coils, conservative specific absorption rate constraints, and magnified sample-induced amplitude of radiofrequency field inhomogeneity. In the present study, an initial attempt was made to address these challenges and to implement coronary MR angiography at 7 T. A single-element radiofrequency transmit and receive coil was designed and a 7 T specific imaging protocol was implemented, including significant changes in scout scanning, contrast generation, and navigator geometry compared to current protocols at 3 T. With this methodology, the first human coronary MR images were successfully obtained at 7 T, with both qualitative and quantitative findings being presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose Carbon-13 magnetic resonance spectroscopy (13C-MRS) is challenging because of the inherent low sensitivity of 13C detection and the need for radiofrequency transmission at the 1H frequency while receiving the 13C signal, the latter requiring electrical decoupling of the 13C and 1H radiofrequency channels. In this study, we added traps to the 13C coil to construct a quadrature-13C/quadrature-1H surface coil, with sufficient isolation between channels to allow simultaneous operation at both frequencies without compromise in coil performance. Methods Isolation between channels was evaluated on the bench by measuring all coupling parameters. The quadrature mode of the quadrature-13C coil was assessed using in vitro 23Na gradient echo images. The signal-to-noise ratio (SNR) was measured on the glycogen and glucose resonances by 13C-MRS in vitro, compared with that obtained with a linear-13C/quadrature-1H coil, and validated by 13C-MRS in vivo in the human calf at 7T. Results Isolation between channels was better than â^'30 dB. The 23Na gradient echo images indicate a region where the field is strongly circularly polarized. The quadrature coil provided an SNR enhancement over a linear coil of 1.4, in vitro and in vivo. Conclusion It is feasible to construct a double-quadrature 13C-1H surface coil for proton decoupled sensitivity enhanced 13C-NMR spectroscopy in humans at 7T. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 46-year-old man underwent radiofrequency (RF) ablation of three liver metastases 7 months after undergoing right colectomy for a pT2N0Mx colon adenocarcinoma. Three months after the procedure, he developed hepatic abscesses related to a fistula between the distal ileum and segment V biliary branches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To report the biopsy findings of osteoid osteoma (OO) and OO-mimicking lesions, assess their distinctive multidetector computed tomography (MDCT) features and evaluate treatment by radiofrequency ablation (RFA). METHODS: In this multicentric retrospective study, 80 patients (54 male, 26 female, mean age 24.1 years, range 5-48) with presumed (clinical and MDCT features) OO were treated by percutaneous RFA between May 2002 and June 2009. Per-procedural biopsies were always performed. The following MDCT features were assessed: skeletal distribution and location within the bone, size, central calcification, surrounding osteosclerosis and periosteal reaction. Clinical success of RFA was evaluated. RESULTS: Histopathological diagnoses were: 54 inconclusive biopsies, 16 OO, 10 OO-mimicking lesions (5 chronic osteomyelitis, 3 chondroblastoma, 1 eosinophilic granuloma, 1 fibrous dysplasia). OO-mimicking lesions were significantly greater in size (p = 0.001) and presented non-significant trends towards medullary location (p = 0.246), moderate surrounding osteosclerosis (p = 0.189) and less periosteal reaction (p = 0.197), compared with OO. Primary success for ablation of OO-mimicking lesions was 100% at 1 month, 85.7% at 6 and 12 months, and 66.7% at 24 months. Secondary success was 100%. CONCLUSION: Larger size, medullary location, less surrounding osteosclerosis and periosteal reaction on MDCT may help differentiate OO-mimicking lesions from OO. OO-mimicking lesions are safely and successfully treated by RFA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate a transverse electromagnetic (TEM), a circularly polarized (CP) (birdcage), and a 12-channel phased array head coil at the clinical field strength of B0 = 3T in terms of signal-to-noise ratio (SNR), signal homogeneity, and maps of the effective flip angle alpha. MATERIALS AND METHODS: SNR measurements were performed on low flip angle gradient echo images. In addition, flip angle maps were generated for alpha(nominal) = 30 degrees using the double angle method. These evaluation steps were performed on phantom and human brain data acquired with each coil. Moreover, the signal intensity variation was computed for phantom data using five different regions of interest. RESULTS: In terms of SNR, the TEM coil performs slightly better than the CP coil, but is second to the smaller 12-channel coil for human data. As expected, both the TEM and the CP coils show superior image intensity homogeneity than the 12-channel coil, and achieve larger mean effective flip angles than the combination of body and 12-channel coil with reduced radio frequency power deposition. CONCLUSION: At 3T the benefits of TEM coil design over conventional lumped element(s) coil design start to emerge, though the phased array coil retains an advantage with respect to SNR performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the apparent diffusion coefficient (ADC) values of malignant liver lesions on diffusion-weighted MRI (DWI) before and after successful radiofrequency ablation (RF ablation). MATERIALS AND METHODS: Thirty-two patients with 43 malignant liver lesions (23/20: metastases/hepatocellular carcinomas (HCC)) underwent liver MRI (3.0T) before (<1month) and after RF ablation (at 1, 3 and 6months) using T2-, gadolinium-enhanced T1- and DWI-weighted MR sequences. Jointly, two radiologists prospectively measured ADCs for each lesion by means of two different regions of interest (ROIs), first including the whole lesion and secondly the area with the visibly most restricted diffusion (MRDA) on ADC map. Changes of ADCs were evaluated with ANOVA and Dunnett tests. RESULTS: Thirty-one patients were successfully treated, while one patient was excluded due to focal recurrence. In metastases (n=22), the ADC in the whole lesion and in MRDA showed an up-and-down evolution. In HCC (n=20), the evolution of ADC was more complex, but with significantly higher values (p=0.013) at 1 and 6months after RF ablation. CONCLUSION: The ADC values of malignant liver lesions successfully treated by RF ablation show a predictable evolution and may help radiologists to monitor tumor response after treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To analyze outcomes after right portal vein embolization extended to segment IV (right PVE + IV) before extended right hepatectomy, including liver hypertrophy, resection rates, and complications after embolization and resection, and to assess differences in outcomes with two different particulate embolic agents. MATERIALS AND METHODS: Between 1998 and 2004, transhepatic ipsilateral right PVE + IV with particles and coils was performed in 44 patients with malignant hepatobiliary disease, including metastases (n = 24), biliary cancer (n = 14), and hepatocellular carcinoma (n = 6). Right PVE + IV was considered if the future liver remnant (FLR; segments II/III with or without I) was less than 25% of the total estimated liver volume (TELV). Tris-acryl microspheres (100-700 microm; n = 21) or polyvinyl alcohol (PVA) particles (355-1,000 microm; n = 23) were administered in a stepwise fashion. Smaller particles were used to occlude distal branches, followed by larger particles to occlude proximal branches until near-complete stasis. Coils were then placed in secondary portal branches. Computed tomographic volumetry was performed before and 3-4 weeks after right PVE + IV to assess FLR hypertrophy. Liver volumes and postembolization and postoperative outcomes were measured. RESULTS: After right PVE + IV with PVA particles, FLR volume increased 45.5% +/- 40.9% and FLR/TELV ratio increased 6.9% +/- 5.6%. After right PVE + IV with tris-acryl microspheres, FLR volume increased 69.0% +/- 30.7% and FLR/TELV ratio increased 9.7% +/- 3.3%. Differences in FLR volume (P = .0011), FLR/TELV ratio (P = .027), and resection rates (P = .02) were statistically significant. Seventy-one percent of patients underwent extended right hepatectomy (86% after receiving tris-acryl microspheres, 57% after receiving PVA). Thirteen patients (29%) did not undergo resection (extrahepatic spread [n = 9], inadequate hypertrophy [n = 3], other reasons [n = 1]). No patient developed postembolization syndrome or progressive liver insufficiency after embolization or resection. One death after resection occurred as a result of sepsis and hemorrhage. Median hospital stays were 1 day after right PVE + IV and 7 days after resection. CONCLUSION: Transhepatic ipsilateral right PVE + IV with use of particles and coils is a safe, effective method for inducing contralateral hypertrophy before extended right hepatectomy. Embolization with small spherical particles provides improved hypertrophy and resection rates compared with larger, nonspherical particles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the short- and mid-term evolutions of the apparent diffusion coefficient of lesions treated with RF, in order to determine if the ADC can be used as a marker of tumour response. Methods and Materials: Twenty patients were treated for a liver malignancy with RF and were examined on a 1.5 T/3.0 T machine with T2, gadolinium-enhanced T1 and diffusion sequences: before treatment (< 1 month), just after treatment (< 1 month) and midterm (3-6 months). The ADC was measured in the whole lesion and in the area with the most restricted diffusion (MRDA). The ROI size was also measured on the diffusion map. The Pearson/ANOVA tests were used. Results: All patients were successfully treated with complete disappearance of CE. The lesional size on T2 showed a negative evolution in time (p < 0.002). The ADC in the whole lesion showed a bell-shaped evolution (increasing just after RF, then decreasing, p = 0.02). The ROI size on the diffusion map followed a similar course (p = 0.01). For the MRDA, such evolutions were also found, but they were not significant. There was a negative correlation between CE and the ADC (p < 0.02) and between the lesional size on T2 and ADC (p = 0.03) in the whole lesion. There were also positive correlations between the ROI size and ADC (p = 0.0008) and between CE and the size on T2 (p = 0.0002). The ADC in MRDA showed some non-significant correlations with other variables. Conclusion: The lesions successfully treated with RF have a clear and predictable evolution in terms of T2 size, CE and ADC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The glomus tumor is a rare, benign, but painful vascular neoplasm arising from the neuromyoarterial glomus. Primary intraosseous glomus tumor is even rarer, with only about 20 cases reported in the literature so far, 5 of which involved the spine. Surgical resection is currently considered the treatment of choice. We herewith present an uncommon case of primary intraosseous spinal glomus tumor involving the right pedicle of the eleventh thoracic vertebra (T11). To our knowledge, this is the first case of primary intraosseous spinal glomus tumor successfully treated by percutaneous CT-guided radiofrequency ablation (RFA).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs: To describe the technique and results of radiofrequency ablation (RFA) of small renal tumors.Matériels et méthodes: 28 patients with median age 79 years were treated with RFA for small renal exophytic tumor (median size 20 mm). Most patients were poor operative candidatesbecause of associated morbidity. Four patients were treated for biopsy proven papillary tumor, 7 for clear cell carcinoma, 2 for oncocytoma and one for renalhepatocellular metastasis. No biopsy sample was obtained for the others because of a typical radiological aspect of RCC.Résultats: All patients but one were treated successfully in one session under combined ultrasound and CT guidance using either Radionics 2000 cool-tip or Bostonscientific expandable needles, one was treated in two sessions. One Splenic, 3 colic and 1 pancreatic displacement with CO2 injection and one injection of G5%solution in the costo-phrenic recessus were done in order to protect adjacent organs. Two complications were observed, one splenic iatrogenic lesion treated byembolization and one renal pelvis stenosis treated with JJ stent. After a mean follow-up of 20 months, no patient developped local recurrence on MRI follow-up.Conclusion: RFA is a simple and efficient technique pending on strict selected criteria (small size < 3 cm and exophytic lesion). Long local control is obtained with minimalmorbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The glomus tumor is a rare, benign, but painful vascular neoplasm arising from the neuromyoarterial glomus. Primary intraosseous glomus tumor is even rarer, with only about 20 cases reported in the literature so far, 5 of which involved the spine. Surgical resection is currently considered the treatment of choice. We herewith present an uncommon case of primary intraosseous spinal glomus tumor involving the right pedicle of the eleventh thoracic vertebra (T11). To our knowledge, this is the first case of primary intraosseous spinal glomus tumor successfully treated by percutaneous CT-guided radiofrequency ablation (RFA).