4 resultados para Radar in navigation.

em Université de Lausanne, Switzerland


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this retrospective study was to compare the clinical and radiographic results after TKA (PFC, DePuy), performed either by computer assisted navigation (CAS, Brainlab, Johnson&Johnson) or by conventional means. Material and methods: Between May and December 2006 we reviewed 36 conventional TKA performed between 2002 and 2003 (group A) and 37 navigated TKA performed between 2005 and 2006 (group B) by the same experienced surgeon. The mean age in group A was 74 years (range 62-90) and 73 (range 58-85) in group B with a similar age distribution. The preoperative mechanical axes in group A ranged from -13° varus to +13° valgus (mean absolute deviation 6.83°, SD 3.86), in group B from -13° to +16° (mean absolute deviation 5.35, SD 4.29). Patients with a previous tibial osteotomy or revision arthroplasty were excluded from the study. Examination was done by an experienced orthopedic resident independent of the surgeon. All patients had pre- and postoperative long standing radiographs. The IKSS and the WOMAC were utilized to determine the clinical outcome. Patient's degree of satisfaction was assessed on a visual analogous scale (VAS). Results: 32 of the 37 navigated TKAs (86,5%) showed a postoperative mechanical axis within the limits of 3 degrees of valgus or varus deviation compared to only 24 (66%) of the 36 standard TKAs. This difference was significant (p = 0.045). The mean absolute deviation from neutral axis was 3.00° (range -5° to +9°, SD: 1.75) in group A in comparison to 1.54° (range -5° to +4°, SD: 1.41) in group B with a highly significant difference (p = 0.000). Furthermore, both groups showed a significant postoperative improvement of their mean IKSS-values (group A: 89 preoperative to 169 postoperative, group B 88 to 176) without a significant difference between the two groups. Neither the WOMAC nor the patient's degree of satisfaction - as assessed by VAS - showed significant differences. Operation time was significantly higher in group B (mean 119.9 min.) than in group A (mean 99.6 min., p <0.000). Conclusion: Our study showed consistent significant improvement of postoperative frontal alignment in TKA by computer assisted navigation (CAS) compared to standard methods, even in the hands of a surgeon well experienced in standard TKA implantation. However, the follow-up time of this study was not long enough to judge differences in clinical outcome. Thus, the relevance of computer navigation for clinical outcome and survival of TKA remains to be proved in long term studies to justify the longer operation time. References 1 Stulberg SD. Clin Orth Rel Res. 2003;(416):177-84. 2 Chauhan SK. JBJS Br. 2004;86(3):372-7. 3 Bäthis H, et al. Orthopäde. 2006;35(10):1056-65.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Practice guidelines for examining febrile patients presenting upon returning from the tropics were developed to assist primary care physicians in decision making. Because of the low level of evidence available in this field, there was a need to validate them and assess their feasibility in the context they have been designed for. OBJECTIVES: The objectives of the study were to (1) evaluate physicians' adherence to recommendations; (2) investigate reasons for non-adherence; and (3) ensure good clinical outcome of patients, the ultimate goal being to improve the quality of the guidelines, in particular to tailor them for the needs of the target audience and population. METHODS: Physicians consulting the guidelines on the Internet (www.fevertravel.ch) were invited to participate in the study. Navigation through the decision chart was automatically recorded, including diagnostic tests performed, initial and final diagnoses, and clinical outcomes. The reasons for non-adherence were investigated and qualitative feedback was collected. RESULTS: A total of 539 physician/patient pairs were included in this study. Full adherence to guidelines was observed in 29% of the cases. Figure-specific adherence rate was 54.8%. The main reasons for non-adherence were as follows: no repetition of malaria tests (111/352) and no presumptive antibiotic treatment for febrile diarrhea (64/153) or abdominal pain without leukocytosis (46/101). Overall, 20% of diversions from guidelines were considered reasonable because there was an alternative presumptive diagnosis or the symptoms were mild, which means that the corrected adherence rate per case was 40.6% and corrected adherence per figure was 61.7%. No death was recorded and all complications could be attributed to the underlying illness rather than to adherence to guidelines. CONCLUSIONS: These guidelines proved to be feasible, useful, and leading to good clinical outcomes. Almost one third of physicians strictly adhered to the guidelines. Other physicians used the guidelines not to forget specific diagnoses but finally diverged from the proposed attitudes. These diversions should be scrutinized for further refinement of the guidelines to better fit to physician and patient needs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study uses digital elevation models and ground-penetrating radar to quantify the relation between the surface morphodynamics and subsurface sedimentology in the sandy braided South Saskatchewan River, Canada. A unique aspect of the methodology is that both digital elevation model and ground-penetrating radar data were collected from the same locations in 2004, 2005, 2006 and 2007, thus enabling the surface morphodynamics to be tied explicitly to the associated evolving depositional product. The occurrence of a large flood in 2005 also allowed the influence of discharge to be assessed with respect to the processproduct relationship. The data demonstrate that the morphology of the study reach evolved even during modest discharges, but more extensive erosion was caused by the large flood. In addition, the study reach was dominated by compound bars before the flood, but switched to being dominated by unit bars during and after the flood. The extent to which the subsurface deposits (the product') were modified by the surface morphodynamics (the process') was quantified using the changes in radar-facies recorded in sequential ground-penetrating radar surveys. These surveys reveal that during the large flood there was an increase in the proportion of facies associated with bar margin accretion and larger dunes. In subsequent years, these facies became truncated and replaced with facies associated with smaller dune sets. This analysis shows that unit bars generally become truncated more laterally than vertically and, thus, they lose the high-angle bar margin deposits and smaller scale bar-top deposits. In general, the only fragments that remain of the unit bars are dune sets, thus making identification of the original unit barform problematic. This novel data set has implications for what may ultimately become preserved in the rock record.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study design: A retrospective study of image guided cervical implant placement precision. Objective: To describe a simple and precise classification of cervical critical screw placement. Summary of Background Data: "Critical" screw placement is defined as implant insertion into a bone corridor which is surrounded circumferentially by neurovascular structures. While the use of image guidance has improved accuracy, there is currently no classification which provides sufficient precision to assess the navigation success of critical cervical screw placement. Methods: Based on postoperative clinical evaluation and CT imaging, the orthogonal view evaluation method (OVEM) is used to classify screw accuracy into grade I (no cortical breach), grade la (screw thread cortical breach), grade II (internal diameter cortical breach) and grade III (major cortical breach causing neural or vascular injury). Grades II and III are considered to be navigation failures, after accounting for bone corridor / screw mismatch (minimal diameter of targeted bone corridor being smaller than an outer screw diameter). Results: A total of 276 screws from 91 patients were classified into grade I (64.9%), grade la (18.1%), and grade II (17.0%). No grade III screw was observed. The overall rate of navigation failure was 13%. Multiple logistic regression indicated that navigational failure was significantly associated with the level of instrumentation and the navigation system used. Navigational failure was rare (1.6%) when the margin around the screw in the bone corridor was larger than 1.5 mm. Conclusions: OVEM evaluation appears to be a useful tool to assess the precision of critical screw placement in the cervical spine. The OVEM validity and reliability need to be addressed. Further correlation with clinical outcomes will be addressed in future studies.