28 resultados para RC beams
em Université de Lausanne, Switzerland
Resumo:
3D dose reconstruction is a verification of the delivered absorbed dose. Our aim was to describe and evaluate a 3D dose reconstruction method applied to phantoms in the context of narrow beams. A solid water phantom and a phantom containing a bone-equivalent material were irradiated on a 6 MV linac. The transmitted dose was measured by using one array of a 2D ion chamber detector. The dose reconstruction was obtained by an iterative algorithm. A phantom set-up error and organ interfraction motion were simulated to test the algorithm sensitivity. In all configurations convergence was obtained within three iterations. A local reconstructed dose agreement of at least 3% / 3mm with respect to the planned dose was obtained, except in a few points of the penumbra. The reconstructed primary fluences were consistent with the planned ones, which validates the whole reconstruction process. The results validate our method in a simple geometry and for narrow beams. The method is sensitive to a set-up error of a heterogeneous phantom and interfraction heterogeneous organ motion.
Resumo:
In mammography, the image contrast and dose delivered to the patient are determined by the x-ray spectrum and the scatter to primary ratio S/P. Thus the quality of the mammographic procedure is highly dependent on the choice of anode and filter material and on the method used to reduce the amount of scattered radiation reaching the detector. Synchrotron radiation is a useful tool to study the effect of beam energy on the optimization of the mammographic process because it delivers a high flux of monochromatic photons. Moreover, because the beam is naturally flat collimated in one direction, a slot can be used instead of a grid for scatter reduction. We have measured the ratio S/P and the transmission factors for grids and slots for monoenergetic synchrotron radiation. In this way the effect of beam energy and scatter rejection method were separated, and their respective importance for image quality and dose analyzed. Our results show that conventional mammographic spectra are not far from optimum and that the use of a slot instead of a grid has an important effect on the optimization of the mammographic process. We propose a simple numerical model to quantify this effect.
Resumo:
OBJECTIVE: To compare outcomes of patients with lymph node (LN)-positive urothelial carcinoma of the bladder (UCB) treated with or without cisplatin-based combined adjuvant chemotherapy (AC) after radical cystectomy (RC). PATIENTS AND METHODS: We retrospectively analysed 1523 patients with LN-positive UCB, who underwent RC with bilateral pelvic LN dissection. All patients had no evidence of disease after RC. AC was administered within 3 months. Competing-risks models were applied to compare UCB-related mortality. RESULTS: Of the 1523 patients, 874 (57.4%) received AC. The cumulative 1-, 2- and 5-year UCB-related mortality rates for all patients were 16%, 36% and 56%, respectively. Administration of AC was associated with an 18% relative reduction in the risk of UCB-related death (subhazard ratio 0.82, P = 0.005). The absolute reduction in mortality was 3.5% at 5 years. The positive effect of AC was detectable in patients aged ≤70 years, in women, in pT3-4 disease, and in those with a higher LN density and lymphovascular invasion. This study is limited by its retrospective and non-randomised design, selection bias, the absence of central pathological review and lack in standardisation of LN dissection and cisplatin-based protocols. CONCLUSION: AC seems to reduce UCB-related mortality in patients with LN-positive UCB after RC. Younger patients, women and those with high-risk features such as pT3-4 disease, a higher LN density and lymphovascular invasion appear to benefit most. Appropriately powered prospective randomised trials are necessary to confirm these findings.
Resumo:
Radiotherapy is a widely used treatment option in cancer. However, recent evidence suggests that doses of ionizing radiation (IR) delivered inside the tumor target volume, during fractionated radiotherapy, can promote tumor invasion and metastasis. Furthermore, the tissues that surround the tumor area are also exposed to low doses of IR that are lower than those delivered inside the tumor mass, because external radiotherapy is delivered to the tumor through multiple radiation beams, in order to prevent damage of organs at risk. The biological effects of these low doses of IR on the healthy tissue surrounding the tumor area, and in particular on the vasculature remain largely to be determined. We found that doses of IR lower or equal to 0.8 Gy enhance endothelial cell migration without impinging on cell proliferation or survival. Moreover, we show that low-dose IR induces a rapid phosphorylation of several endothelial cell proteins, including the Vascular Endothelial Growth Factor (VEGF) Receptor-2 and induces VEGF production in hypoxia mimicking conditions. By activating the VEGF Receptor-2, low-dose IR enhances endothelial cell migration and prevents endothelial cell death promoted by an anti-angiogenic drug, bevacizumab. In addition, we observed that low-dose IR accelerates embryonic angiogenic sprouting during zebrafish development and promotes adult angiogenesis during zebrafish fin regeneration and in the murine Matrigel assay. Using murine experimental models of leukemia and orthotopic breast cancer, we show that low-dose IR promotes tumor growth and metastasis and that these effects were prevented by the administration of a VEGF receptor-tyrosine kinase inhibitor immediately before IR exposure. These findings demonstrate a new mechanism to the understanding of the potential pro-metastatic effect of IR and may provide a new rationale basis to the improvement of current radiotherapy protocols.
Resumo:
To make a comprehensive evaluation of organ-specific out-of-field doses using Monte Carlo (MC) simulations for different breast cancer irradiation techniques and to compare results with a commercial treatment planning system (TPS). Three breast radiotherapy techniques using 6MV tangential photon beams were compared: (a) 2DRT (open rectangular fields), (b) 3DCRT (conformal wedged fields), and (c) hybrid IMRT (open conformal+modulated fields). Over 35 organs were contoured in a whole-body CT scan and organ-specific dose distributions were determined with MC and the TPS. Large differences in out-of-field doses were observed between MC and TPS calculations, even for organs close to the target volume such as the heart, the lungs and the contralateral breast (up to 70% difference). MC simulations showed that a large fraction of the out-of-field dose comes from the out-of-field head scatter fluence (>40%) which is not adequately modeled by the TPS. Based on MC simulations, the 3DCRT technique using external wedges yielded significantly higher doses (up to a factor 4-5 in the pelvis) than the 2DRT and the hybrid IMRT techniques which yielded similar out-of-field doses. In sharp contrast to popular belief, the IMRT technique investigated here does not increase the out-of-field dose compared to conventional techniques and may offer the most optimal plan. The 3DCRT technique with external wedges yields the largest out-of-field doses. For accurate out-of-field dose assessment, a commercial TPS should not be used, even for organs near the target volume (contralateral breast, lungs, heart).
Resumo:
Carcinoembryonic antigen (CEA) is a well-known tumor marker, consisting of a single heavily glycosylated polypeptide chain (mol. wt 200 kD), bound to the cell surface by a phosphatidylinositol-glycan anchor. The hydrophobic domain, encoded by the 3' end of the open reading frame of the CEA gene is not present in the mature protein. This domain is assumed to play an important role in the targeting and attachment of CEA to the cell surface. To verify this hypothesis, a recombinant CEA cDNA lacking the 78 b.p. of the 3' region, encoding the 26 a.a. hydrophobic domain, was prepared in a Rc/CMV expression vector containing a neomycin resistance gene. The construct was transfected by the calcium phosphate technique into CEA-negative human and rat colon carcinoma cell lines. Geneticin-resistant transfectants were screened for the presence of CEA in the supernatant and positive clones were isolated. As determined by ELISA, up to 13 micrograms of recombinant CEA per 10(6) cells was secreted within 72 hr by the human transfected cells and about 1 microgram by the rat cells. For comparison, two human carcinoma cell lines, CO112 and LS174T, selected for high CEA expression, shed about 45 and 128 ng per 10(6) cells within 72 hr, respectively. Western blot analysis showed that the size of the recombinant CEA secreted by the transfected human cells is identical to that of reference CEA purified from human colon carcinomas metastases (about 200 kD). The recombinant CEA synthesized by the transfected rat carcinoma cells has a smaller size (about 144 kD, possibly due to incomplete glycosylation), as has already been observed for CEA produced by rat colon carcinoma cells transfected with full-length CEA cDNA. The 100-fold increase in secretion of rCEA encoded by truncated CEA cDNA transfected in human cells confirms the essential role of this domain in the targeting and anchoring of the glycoprotein. These results suggest a new approach for the in vitro production of large amounts of CEA needed in research laboratories and for immunoassay kits.
Resumo:
BACKGROUND: Anaemia represents a common complication of inflammatory bowel disease (IBD). Most studies on anaemia in IBD patients have been performed in tertiary referral centres (RC) and data from gastroenterologic practices (GP) are lacking. We investigated the frequency and severity of anaemia in IBD patients from tertiary referral centres and gastroenterologic practices compared to the general population. METHODS: Data were acquired from patients included in the Swiss IBD Cohort Study. IBD activity was evaluated by CDAI and modified Truelove and Witts severity index (MTWSI). Anaemia was defined as haemoglobin ≤120g/L in women and ≤130g/L in men. RESULTS: 125 patients from RC (66 with Crohn's disease (CD) and 59 with ulcerative colitis (UC)) and 116 patients from GP (71 CD and 45 UC) were included and compared to 6074 blood donors. Anaemia was found in 21.2% (51/241) of the IBD patients and more frequently in patients from RC as compared to GP and healthy controls (28.8% vs. 12.9% vs. 3.4%; P<0.01). IBD patients from RC suffered more frequently from active disease compared to IBD patients in GP (36% vs. 23%, P=0.032). Supplementation therapy (iron, vitamin B12, folic acid) was performed in 40% of anaemic IBD patients in GP as compared to 43% in RC. CONCLUSIONS: Anaemia is a common complication in patients with IBD and significantly more prevalent in patients from referral centres as compared to patients from gastroenterologic practices. Physicians treating IBD patients should pay attention to the presence of anaemia and ensure sufficient supplementation therapy.
Resumo:
Hepatitis C virus (HCV) replicates its genome in a membrane-associated replication complex (RC). Specific membrane alterations, designated membranous webs, represent predominant sites of HCV RNA replication. The principles governing HCV RC and membranous web formation are poorly understood. Here, we used replicons harboring a green fluorescent protein (GFP) insertion in nonstructural protein 5A (NS5A) to study HCV RCs in live cells. Two distinct patterns of NS5A-GFP were observed. (i) Large structures, representing membranous webs, showed restricted motility, were stable over many hours, were partitioned among daughter cells during cell division, and displayed a static internal architecture without detectable exchange of NS5A-GFP. (ii) In contrast, small structures, presumably representing small RCs, showed fast, saltatory movements over long distances. Both populations were associated with endoplasmic reticulum (ER) tubules, but only small RCs showed ER-independent, microtubule (MT)-dependent transport. We suggest that this MT-dependent transport sustains two distinct RC populations, which are both required during the HCV life cycle.
Resumo:
PURPOSE: Early assessment of radiotherapy (RT) quality in the ongoing EORTC trial comparing primary temozolomide versus RT in low-grade gliomas. MATERIALS AND METHODS: RT plans provided for dummy cases were evaluated and compared against expert plans. We analysed: (1) tumour and organs-at-risk delineation, (2) geometric and dosimetric characteristics, (3) planning parameters, compliance with dose prescription and Dmax for OAR (4) indices: RTOG conformity index (CI), coverage factor (CF), tissue protection factor (PF); conformity number (CN = PF x CF); dose homogeneity in PTV (U). RESULTS: Forty-one RT plans were evaluated. Only two (5%) centres were requested to repeat CTV-PTV delineations. Three (7%) plans had a significant under-dosage and dose homogeneity in one deviated > 10%. Dose distribution was good with mean values of 1.5, 1, 0.68, and 0.68 (ideal values = 1) for CI, CF, PF, and CN, respectively. CI and CN strongly correlated with PF and they correlated with PTV. Planning with more beams seems to increase PTV(Dmin), improving CF. U correlated with PTV(Dmax). CONCLUSION: Preliminary results of the dummy run procedure indicate that most centres conformed to protocol requirements. To quantify plan quality we recommend systematic calculation of U and either CI or CN, both of which measure the amount of irradiated normal brain tissue.
Resumo:
In vivo dosimetry is a way to verify the radiation dose delivered to the patient in measuring the dose generally during the first fraction of the treatment. It is the only dose delivery control based on a measurement performed during the treatment. In today's radiotherapy practice, the dose delivered to the patient is planned using 3D dose calculation algorithms and volumetric images representing the patient. Due to the high accuracy and precision necessary in radiation treatments, national and international organisations like ICRU and AAPM recommend the use of in vivo dosimetry. It is also mandatory in some countries like France. Various in vivo dosimetry methods have been developed during the past years. These methods are point-, line-, plane- or 3D dose controls. A 3D in vivo dosimetry provides the most information about the dose delivered to the patient, with respect to ID and 2D methods. However, to our knowledge, it is generally not routinely applied to patient treatments yet. The aim of this PhD thesis was to determine whether it is possible to reconstruct the 3D delivered dose using transmitted beam measurements in the context of narrow beams. An iterative dose reconstruction method has been described and implemented. The iterative algorithm includes a simple 3D dose calculation algorithm based on the convolution/superposition principle. The methodology was applied to narrow beams produced by a conventional 6 MV linac. The transmitted dose was measured using an array of ion chambers, as to simulate the linear nature of a tomotherapy detector. We showed that the iterative algorithm converges quickly and reconstructs the dose within a good agreement (at least 3% / 3 mm locally), which is inside the 5% recommended by the ICRU. Moreover it was demonstrated on phantom measurements that the proposed method allows us detecting some set-up errors and interfraction geometry modifications. We also have discussed the limitations of the 3D dose reconstruction for dose delivery error detection. Afterwards, stability tests of the tomotherapy MVCT built-in onboard detector was performed in order to evaluate if such a detector is suitable for 3D in-vivo dosimetry. The detector showed stability on short and long terms comparable to other imaging devices as the EPIDs, also used for in vivo dosimetry. Subsequently, a methodology for the dose reconstruction using the tomotherapy MVCT detector is proposed in the context of static irradiations. This manuscript is composed of two articles and a script providing further information related to this work. In the latter, the first chapter introduces the state-of-the-art of in vivo dosimetry and adaptive radiotherapy, and explains why we are interested in performing 3D dose reconstructions. In chapter 2 a dose calculation algorithm implemented for this work is reviewed with a detailed description of the physical parameters needed for calculating 3D absorbed dose distributions. The tomotherapy MVCT detector used for transit measurements and its characteristics are described in chapter 3. Chapter 4 contains a first article entitled '3D dose reconstruction for narrow beams using ion chamber array measurements', which describes the dose reconstruction method and presents tests of the methodology on phantoms irradiated with 6 MV narrow photon beams. Chapter 5 contains a second article 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations. A dose reconstruction process specific to the use of the tomotherapy MVCT detector is presented in chapter 6. A discussion and perspectives of the PhD thesis are presented in chapter 7, followed by a conclusion in chapter 8. The tomotherapy treatment device is described in appendix 1 and an overview of 3D conformai- and intensity modulated radiotherapy is presented in appendix 2. - La dosimétrie in vivo est une technique utilisée pour vérifier la dose délivrée au patient en faisant une mesure, généralement pendant la première séance du traitement. Il s'agit de la seule technique de contrôle de la dose délivrée basée sur une mesure réalisée durant l'irradiation du patient. La dose au patient est calculée au moyen d'algorithmes 3D utilisant des images volumétriques du patient. En raison de la haute précision nécessaire lors des traitements de radiothérapie, des organismes nationaux et internationaux tels que l'ICRU et l'AAPM recommandent l'utilisation de la dosimétrie in vivo, qui est devenue obligatoire dans certains pays dont la France. Diverses méthodes de dosimétrie in vivo existent. Elles peuvent être classées en dosimétrie ponctuelle, planaire ou tridimensionnelle. La dosimétrie 3D est celle qui fournit le plus d'information sur la dose délivrée. Cependant, à notre connaissance, elle n'est généralement pas appliquée dans la routine clinique. Le but de cette recherche était de déterminer s'il est possible de reconstruire la dose 3D délivrée en se basant sur des mesures de la dose transmise, dans le contexte des faisceaux étroits. Une méthode itérative de reconstruction de la dose a été décrite et implémentée. L'algorithme itératif contient un algorithme simple basé sur le principe de convolution/superposition pour le calcul de la dose. La dose transmise a été mesurée à l'aide d'une série de chambres à ionisations alignées afin de simuler la nature linéaire du détecteur de la tomothérapie. Nous avons montré que l'algorithme itératif converge rapidement et qu'il permet de reconstruire la dose délivrée avec une bonne précision (au moins 3 % localement / 3 mm). De plus, nous avons démontré que cette méthode permet de détecter certaines erreurs de positionnement du patient, ainsi que des modifications géométriques qui peuvent subvenir entre les séances de traitement. Nous avons discuté les limites de cette méthode pour la détection de certaines erreurs d'irradiation. Par la suite, des tests de stabilité du détecteur MVCT intégré à la tomothérapie ont été effectués, dans le but de déterminer si ce dernier peut être utilisé pour la dosimétrie in vivo. Ce détecteur a démontré une stabilité à court et à long terme comparable à d'autres détecteurs tels que les EPIDs également utilisés pour l'imagerie et la dosimétrie in vivo. Pour finir, une adaptation de la méthode de reconstruction de la dose a été proposée afin de pouvoir l'implémenter sur une installation de tomothérapie. Ce manuscrit est composé de deux articles et d'un script contenant des informations supplémentaires sur ce travail. Dans ce dernier, le premier chapitre introduit l'état de l'art de la dosimétrie in vivo et de la radiothérapie adaptative, et explique pourquoi nous nous intéressons à la reconstruction 3D de la dose délivrée. Dans le chapitre 2, l'algorithme 3D de calcul de dose implémenté pour ce travail est décrit, ainsi que les paramètres physiques principaux nécessaires pour le calcul de dose. Les caractéristiques du détecteur MVCT de la tomothérapie utilisé pour les mesures de transit sont décrites dans le chapitre 3. Le chapitre 4 contient un premier article intitulé '3D dose reconstruction for narrow beams using ion chamber array measurements', qui décrit la méthode de reconstruction et présente des tests de la méthodologie sur des fantômes irradiés avec des faisceaux étroits. Le chapitre 5 contient un second article intitulé 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations'. Un procédé de reconstruction de la dose spécifique pour l'utilisation du détecteur MVCT de la tomothérapie est présenté au chapitre 6. Une discussion et les perspectives de la thèse de doctorat sont présentées au chapitre 7, suivies par une conclusion au chapitre 8. Le concept de la tomothérapie est exposé dans l'annexe 1. Pour finir, la radiothérapie «informationnelle 3D et la radiothérapie par modulation d'intensité sont présentées dans l'annexe 2.
Resumo:
C4-dicarboxylates are one of the preferred carbon and energy sources for the growth of P. aeruginosa, a ubiquitous and metabolically versatile bacterium. However, despite their importance, C4-dicarboxylates sensing and uptake systems were poorly understood in P. aeruginosa and only little information was available in the literature. In our work, the C4-dicarboxylate transport (Dct) system in P. aeruginosa was found to be composed of a novel two-component system, called DctB/DctD, regulating together with the sigma factor RpoN the expression of two newly identified C4-dicarboxylate transporters: DctA and DctPQM. Inactivation of the dct A, dctB or dctD gene caused a growth defect of the strain in minimal media supplemented with succinate, fumarate or malate, indicating their major role in Dct. However, residual growth of the dctA mutant in these media suggested the presence of redundant C4-dicarboxylate transporter(s). Tn5 insertion mutagenesis of the kdctA mutant, combined with a screening for growth on succinate, led to the identification of a second Dct system, the DctPQM transporter, belonging to the tripartite ATP-independent periplasmic (TRAP) family of carriers. AdctAAdctPQM double mutant showed no growth on malate and fumarate albeit residual growth on succinate suggested that additional transporters for succinate are present. Competition experiments demonstrated that the DctPQM carrier was more efficient than the DctA carrier for the utilization of succinate at μΜ concentrations, whereas DctA was the major transporter at mM concentrations. For the first time, high- and low-affinity uptake systems for succinate (DctA and DctPQM) are reported to function co-ordinately to transport C4- dicarboxylates. Most probably, the presence of redundant uptake systems contributes to the versatility of this bacterium. Next, the regulation of the Dct system was investigated. While performing a parallel study about the carbon catabolite repression (CCR) phenomenon in P. aeruginosa, a link between the CCR cascade (CbrAB/CrcZ/Crc) and the Dct system was observed. Crc is a translational repressor acting when preferred carbon sources (like C4-dicarboxylates) are present. CrcZ is a small RNA acting as a functional antagonist of Crc and induced by the CbrA/CbrB two-component system when non preferred carbon sources (like mannitol) are utilized. Novel targets of the CbrAB/CrcZ/Crc system in P. aeruginosa were identified using transcriptome analysis; among them dctA and dctPQM were detected. CCR is regulating the dct transporter genes expression depending on the succinate concentrations in the medium of growth; this modulation of CCR is possible because, at the same time, succinate concentrations tune CCR. In a medium containing high succinate concentrations, CrcZ levels were low and therefore Crc inhibited the translation of mRNA targets. Whereas in a medium containing low succinate concentrations, the subsequent increase of CrcZ levels sequestered Crc, inhibiting its activity. This model shows for the first time that CCR possesses a feedback-based circuitry, a very important type of regulatory loop that confers the best adaptive response under changing environmental conditions. The expression of the dct transporter genes is also found to be regulated by the RNA chaperone protein Hfq. Hfq has the same post-transcriptional effect than Crc at high concentration of succinate, i.e. inhibiting dctP and dctR and indirectly favouring dctA expression. Moreover, an additional indirect positive regulation of dctP expression by Hfq was found. Finally, a metabolome approach was performed to investigate the internal signals modulating CCR via induction of CbrA activity in P. aeruginosa PAOl and P. putida KT2442. The results of the analysis are currently under study in the laboratory. - Les acides C4-dicarboxyliques font partie des sources de carbone et d'énergie préférés de P. aeruginosa, une bactérie versatile et ubiquitaire. Néanmoins, malgré leur importance, comment la présence des acides C4-dicarboxyliques dans le milieu est sentie par la bactérie et comment ils sont transportés dans la cellule chez P. aeruginosa n'étaient pas connus. De plus, peu d'informations sur ces procédés ont été répertoriées dans la littérature. Grace à notre travail, le système de transport des acides C4-dicarboxyliques (Dct) chez P. aeruginosa a pu être caractérisé. En effet, il est composé d'un nouveau système à deux composants, nommé DctB/DctD, qui régule, en combinaison avec le facteur sigma alternatif RpoN, l'expression des deux nouveaux transporteurs des acides C4-dicarboxyliques: DctA et DctPQM. L'inactivation des gènes dctA, dctB or dctD cause un défaut de croissance des souches mutantes dans un milieu minimum contenant du succinate, fumarate ou malate; confirmation de leur rôle dans le Dct. Cependant, une croissance résiduelle du mutant dctA dans ces milieux suggérerait une redondance des transporteurs d'acides Grdicarboxyliques. Une expérience de mutagenèse dans la souche AdctA, utilisant le transposon Tn5, combiné avec un criblage génétique sur la croissance dans le succinate, nous a permis d'identifier le deuxième transporteur DctPQM. DctPQM appartient à la famille des transporteurs TRAP (tripartite ATP-independent periplasmic). Un double mutant AdctAAdctPQM ne pousse pas dans du malate ou fumarate mais par contre présente une croissance résiduelle dans le succinate suggérant l'existence de transporteurs supplémentaires pour le succinate. En réalisant des expériences de compétitions nous avons démontré que le transporteur DctPQM est plus efficace que le transporteur DctA pour l'utilisation de succinate à une concentration de l'ordre du μΜ. Par contre, DctA est le transporteur le plus important pour une concentration de succinate de l'ordre du raM. Pour la première fois, deux systèmes de transport, un avec une forte- et un avec une faible-affinité (DctA et DctPQM) pour le succinate, sont coordonnés dans leur activité de transport des acides C4- dicarboxyliques, probablement contribuant à la versatilité de la bactérie. Ensuite, nous avons étudié la régulation du system Dct. En effectuant, en parallèle, une étude sur le phénomène de la répression catabolique (RC) chez P. aeruginosa, un lien entre la RC et le système Dct a été observé. La cascade des régulateurs formant la RC est composée de CbrA/CbrB, CrcZ et Crc. Crc est un répresseur traductionnel qui agit quand des sources de carbone préférées (comme les acides C4-dicarboxyliques) sont présentes dans le milieu. CrcZ est un petit ARN non-codant qui agit comme antagoniste de Crc. L'expression de CrcZ est induite par le système à deux composants CbrA/CbrB lorsque une source de carbone non-préférée est utilisée (comme le mannitol). Des nouvelles cibles du système CbrAB/CrcZ/Crc chez P. aeruginosa ont été identifiées grâce à une analyse du transcriptome des souches mutantes des régulateurs de la cascade. Parmi les cibles identifiées, les gènes dctA et dctPQM étaient présents. La RC régule l'expression des transporteurs dct en fonction de la concentration de succinate dans le milieu de croissance. Cette régulation est possible parce que, en même temps, les acides C4- dicarboxyliques régulent la RC. Dans un milieu contenant une grande concentration du succinate, le niveau d'expression de CrcZ est faible, donc Crc peut inhiber l'expression de ces ARN messagers cibles. Par contre, dans un milieu avec une faible concentration de succinate, l'augmentation de l'expression de CrcZ titre Crc et inhibe son activité. Ce modèle de régulation rétroactive est très important pour le phénomène de la RC, parce qu'il permet à la bactérie d'accorder une meilleure réponse à un changement environnemental. L'expression des gènes codant pour les transporteurs dct sont aussi régulés par la protéine chaperonne d'ARN Hfq. Hfq semble avoir le même effet traductionnelle que Crc, lorsqu'il y a une forte concentration de succinate. Nous avons ainsi observé une régulation négative de l'expression du gène dct Ρ et dctR, qui code pour un répresseur de la transcription de dctA. Nous avons aussi observé une régulation positive de la transcription de dctP par Hfq, probablement de façon indirecte. Enfin, une analyse du metabolome a était utilisée pour chercher les signaux internes modulant la RC et, en particulier, l'activité de la protéine senseur CbrA chez P. aeruginosa PAOl et P. putida KT2442. Les résultats de l'analyse sont en cours d'étude dans le laboratoire.