27 resultados para Pupil Diameter
em Université de Lausanne, Switzerland
Resumo:
PURPOSE: We determined the effect of entrance pupil size on retinal illumination. The influence of unilateral miosis on the magnitude of the pupil light reflex was studied to ascertain how a clinically significant anisocoria influences the relative afferent pupil defect (RAPD). METHODS: Miosis was induced by topical 1% pilocarpine in the right eye of 14 healthy subjects with normal eyes. The interocular difference in retinal illumination was assessed by computerized pupillometry from the stimulus response curve of the right and left eyes. The main outcome measure was the RAPD, determined by computerized pupillography, at baseline and after pilocarpine-induced anisocoria. RESULTS: Induced anisocoria produced a significant change in RAPD from baseline (mean = 1.60 dB in the miotic eye, P = 0.007). However, anisocoria correlated with RAPD only in subjects with darkly pigmented irides (Pearson correlation coefficient 0.793, P = 0.05). CONCLUSIONS: In darkly pigmented eyes, entrance pupil size significantly influenced the retinal illumination. However, retinal illumination of lightly pigmented eyes is relatively independent of entrance pupil size, presumably due to extrapupillary transmission of light through the iris and sclera. This has important implications in understanding the potential influence of anisocoria on the RAPD and also greater susceptibility of lightly pigmented eyes to light toxicity.
Resumo:
Purpose: Revolutionary endovascular treatments are on the verge of being available for management of ascending aortic diseases. Morphometric measurements of the ascending aorta have already been done with ECG-gated MDCT to help such therapeutic development. However the reliability of these measurements remains unknown. The objective of this work was to compare the intraobserver and interobserver variability of CAD (computer aided diagnosis) versus manual measurements in the ascending aorta. Methods and materials: Twenty-six consecutive patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters at mid-distance between the brachiocephalic artery and the aortic valve were obtained automatically with a commercially available CAD and manually by two observers separately. Both observers repeated the measurements during a different session at least one month after the first measurements. Intraclass coefficients as well the Bland and Altman method were used for comparison between measurements. Two-paired t-test was used to determine the significance of intraobserver and interobserver differences (alpha = 0.05). Results: There is a significant difference between CAD and manual measurements in the maximum diameter (p = 0.004) for the first observer, whereas the difference was significant for minimum diameter between the second observer and the CAD (p <0.001). Interobserver variability showed a weak agreement when measurements were done manually. Intraobserver variability was lower with the CAD compared to the manual measurements (limits of variability: from -0.7 to 0.9 mm for the former and from -1.2 to 1.3 mm for the latter). Conclusion: In order to improve reproductibility of measurements whenever needed, pre- and post-therapeutic management of the ascending aorta may benefit from follow-up done by a unique observer with the help of CAD.
Resumo:
Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.
Resumo:
PURPOSE: We characterized the pupil responses that reflect rod, cone, and melanopsin function in a genetically homogeneous cohort of patients with autosomal dominant retinitis pigmentosa (adRP). METHODS: Nine patients with Gly56Arg mutation of the NR2E3 gene and 12 control subjects were studied. Pupil and subjective visual responses to red and blue light flashes over a 7 log-unit range of intensities were recorded under dark and light adaptation. The pupil responses were plotted against stimulus intensity to obtain red-light and blue-light response curves. RESULTS: In the dark-adapted blue-light stimulus condition, patients showed significantly higher threshold intensities for visual perception and for a pupil response compared to controls (P = 0.02 and P = 0.006, respectively). The rod-dependent, blue-light pupil responses decreased with disease progression. In contrast, the cone-dependent pupil responses (light-adapted red-light stimulus condition) did not differ between patients and controls. The difference in the retinal sensitivity to blue and red stimuli was the most sensitive parameter to detect photoreceptor dysfunction. Unexpectedly, the melanopsin-mediated pupil response was decreased in patients (P = 0.02). CONCLUSIONS: Pupil responses of patients with NR2E3-associated adRP demonstrated reduced retinal sensitivity to dim blue light under dark adaptation, presumably reflecting decreased rod function. Rod-dependent pupil responses were quantifiable in all patients, including those with non-recordable scotopic electroretinogram, and correlated with the extent of clinical disease. Thus, the chromatic pupil light reflex can be used to monitor photoreceptor degeneration over a larger range of disease progression compared to standard electrophysiology.
Resumo:
OBJECTIVE: To weight the rod-, cone-, and melanopsin-mediated activation of the retinal ganglion cells, which drive the pupil light reflex by varying the light stimulus wavelength, intensity, and duration. DESIGN: Experimental study. PARTICIPANTS: Forty-three subjects with normal eyes and 3 patients with neuroretinal visual loss. METHODS: A novel stimulus paradigm was developed using either a long wavelength (red) or short wavelength (blue) light given as a continuous Ganzfeld stimulus with stepwise increases over a 2 log-unit range. The pupillary movement before, during, and after the light stimulus was recorded in real time with an infrared illuminated video camera. MAIN OUTCOME MEASURES: The percent pupil contraction of the transient and sustained pupil response to a low- (1 cd/m(2)), medium- (10 cd/m(2)), and high-intensity (100 cd/m(2)) red- and blue-light stimulus was calculated for 1 eye of each subject. From the 43 normal eyes, median and 25th, 75th, 5th, and 95th percentile values were obtained for each stimulus condition. RESULTS: In normal eyes at lower intensities, blue light evoked much greater pupil responses compared with red light when matched for photopic luminance. The transient pupil contraction was generally greater than the sustained contraction, and this disparity was greatest at the lowest light intensity and least apparent with bright (100 cd/m(2)) blue light. A patient with primarily rod dysfunction (nonrecordable scotopic electroretinogram) showed significantly reduced pupil responses to blue light at lower intensities. A patient with achromatopsia and an almost normal visual field showed selective reduction of the pupil response to red-light stimulation. A patient with ganglion cell dysfunction owing to anterior ischemic optic neuropathy demonstrated global loss of pupil responses to red and blue light in the affected eye. CONCLUSIONS: Pupil responses that differ as a function of light intensity and wavelength support the hypothesis that selected stimulus conditions can produce pupil responses that reflect phototransduction primarily mediated by rods, cones, or melanopsin. Use of chromatic pupil responses may be a novel way to diagnose and monitor diseases affecting either the outer or inner retina.
Resumo:
Recently, morphometric measurements of the ascending aorta have been done with ECG-gated multidector computerized tomography (MDCT) to help the development of future novel transcatheter therapies (TCT); nevertheless, the variability of such measurements remains unknown. Thirty patients referred for ECG-gated CT thoracic angiography were evaluated. Continuous reformations of the ascending aorta, perpendicular to the centerline, were obtained automatically with a commercially available computer aided diagnosis (CAD). Then measurements of the maximal diameter were done with the CAD and manually by two observers (separately). Measurements were repeated one month later. The Bland-Altman method, Spearman coefficients, and a Wilcoxon signed-rank test were used to evaluate the variability, the correlation, and the differences between observers. The interobserver variability for maximal diameter between the two observers was up to 1.2 mm with limits of agreement [-1.5, +0.9] mm; whereas the intraobserver limits were [-1.2, +1.0] mm for the first observer and [-0.8, +0.8] mm for the second observer. The intraobserver CAD variability was 0.8 mm. The correlation was good between observers and the CAD (0.980-0.986); however, significant differences do exist (P<0.001). The maximum variability observed was 1.2 mm and should be considered in reports of measurements of the ascending aorta. The CAD is as reproducible as an experienced reader.
Resumo:
The aim of this study was to investigate influence of traditional cardiovascular risk factors (CVRF) and subclinical atherosclerosis (ATS) burden on early stages of abdominal aortic diameter (AAD) widening among adults. 2,052 consecutive patients (P) (39 % women), mean age 52 ± 13 years, were prospectively screened for CVRF, ATS, and AAD. B-mode ultrasound was used to evaluate the largest AAD and to detect carotid and femoral atherosclerotic plaques. Mean AAD was 15.2 ± 2.8 mm. Atherosclerotic plaques were detected in 71 % of patients. Significant univariate correlation between AAD, traditional CVRF, and ABS was found. However, multiple regression analysis showed that only seven of them were significantly and weakly correlated with AAD (R² = 0.27, p < 0.001). On the other hand, a multivariate logistic analysis was used to evaluate CVRF impact on enlarged AAD ≥25 mm (EAAD) as compared to those with AAD <25 mm. These factors did not account for more than 30 % of interaction (R² = 0.30, p = 0.001). Furthermore, despite a large proportion of patients with high number of CVRF, and subclinical ATS, rate of patients with AAD ≥25 mm was low (1 %) and scattered regardless their CHD risk score or ATS burden. In conclusion, these results suggest that although some traditional CVRF and presence of ATS are associated with early stages of EAAD, other determinants still need to be identified for a better understanding of abdominal aortic aneurysm pathogenesis.
Resumo:
BACKGROUND: The purpose of the optic nerve sheath diameter (ONSD) research group project is to establish an individual patient-level database from high quality studies of ONSD ultrasonography for the detection of raised intracranial pressure (ICP), and to perform a systematic review and an individual patient data meta-analysis (IPDMA), which will provide a cutoff value to help physicians making decisions and encourage further research. Previous meta-analyses were able to assess the diagnostic accuracy of ONSD ultrasonography in detecting raised ICP but failed to determine a precise cutoff value. Thus, the ONSD research group was founded to synthesize data from several recent studies on the subject and to provide evidence on the diagnostic accuracy of ONSD ultrasonography in detecting raised ICP. METHODS: This IPDMA will be conducted in different phases. First, we will systematically search for eligible studies. To be eligible, studies must have compared ONSD ultrasonography to invasive intracranial devices, the current reference standard for diagnosing raised ICP. Subsequently, we will assess the quality of studies included based on the QUADAS-2 tool, and then collect and validate individual patient data. The objectives of the primary analyses will be to assess the diagnostic accuracy of ONSD ultrasonography and to determine a precise cutoff value for detecting raised ICP. Secondly, we will construct a logistic regression model to assess whether patient and study characteristics influence diagnostic accuracy. DISCUSSION: We believe that this IPD MA will provide the most reliable basis for the assessment of diagnostic accuracy of ONSD ultrasonography for detecting raised ICP and to provide a cutoff value. We also hope that the creation of the ONSD research group will encourage further study. TRIAL REGISTRATION: PROSPERO registration number: CRD42012003072.
Resumo:
OBJECTIVE: To determine the pattern of extraocular muscle (EOM) paresis in incomplete vasculopathic third nerve palsies (3NP) that have normal pupillary function. METHODS: A retrospective study in a private practice and academic neuro-ophthalmic practice. Patients diagnosed with vasculopathic 3NP within 4 weeks of symptom onset were identified. The chart of each patient was reviewed to determine pupillary function and the pattern and degree of EOM and levator palpebrae paresis at the time of presentation. RESULTS: Of 55 patients with vasculopathic 3NP, 42 (76%) had normal pupillary function. Of these 42, 23 (55%) demonstrated an incomplete EOM palsy, defined as partially reduced ductions affecting all third nerve-innervated EOMs and levator (diffuse pattern) or partially reduced ductions that involved only some third nerve-innervated EOMs and levator (focal pattern). Twenty (87%) of these 23 patients showed a diffuse pattern of paresis; only three (13%) showed a focal pattern of paresis, one that affected only the superior rectus and levator muscles (superior division weakness). CONCLUSIONS: Based on our series, most patients with EOM/levator involvement in pupil-sparing, incomplete 3NP of vasculopathic origin have a diffuse pattern of paresis. In contrast, our review of the literature suggests that pupil-sparing 3NP of aneurysmal origin usually have a focal pattern of paresis. We propose that distinguishing these two patterns of EOM paresis may be helpful in differentiating between vasculopathic and aneurysmal 3NP. Future studies will be needed to confirm the clinical utility of this hypothesis.
Resumo:
Proper examination of the pupil provides an objective measure of the integrity of the pregeniculate afferent visual pathway and allows assessment of sympathetic and parasympathetic innervation to the eye. Infrared videography and pupillography are increasingly used to study the dynamic behavior of the pupil in common disorders, such as Horner's syndrome and tonic pupil.
Resumo:
PURPOSE: Nonvisual light-dependent functions in humans are conveyed mainly by intrinsically photosensitive retinal ganglion cells, which express melanopsin as photopigment. We aimed to identify the effects of circadian phase and sleepiness across 24 hours on various aspects of the pupil response to light stimulation. METHODS: We tested 10 healthy adults hourly in two 12-hour sessions covering a 24-hour period. Pupil responses to narrow bandwidth red (635 ± 18 nm) and blue (463 ± 24 nm) light (duration of 1 and 30 seconds) at equal photon fluxes were recorded, and correlated with salivary melatonin concentrations at the same circadian phases and to subjective sleepiness ratings. The magnitude of pupil constriction was determined from minimal pupil size. The post-stimulus pupil response was assessed from the pupil size at 6 seconds following light offset, the area within the redilation curve, and the exponential rate of redilation. RESULTS: Among the measured parameters, the pupil size 6 seconds after light offset correlated with melatonin concentrations (P < 0.05) and showed a significant modulation over 24 hours with maximal values after the nocturnal peak of melatonin secretion. In contrast, the post-stimulus pupil response following red light stimulation correlated with subjective sleepiness (P < 0.05) without significant changes over 24 hours. CONCLUSIONS: The post-stimulus pupil response to blue light as a marker of intrinsic melanopsin activity demonstrated a circadian modulation. In contrast, the effect of sleepiness was more apparent in the cone contribution to the pupil response. Thus, pupillary responsiveness to light is under influence of the endogenous circadian clock and subjective sleepiness.