2 resultados para Prolonged application times

em Université de Lausanne, Switzerland


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Drug abuse is a widespread problem affecting both teenagers and adults. Nitrous oxide is becoming increasingly popular as an inhalation drug, causing harmful neurological and hematological effects. Some gas chromatography-mass spectrometry (GC-MS) methods for nitrous oxide measurement have been previously described. The main drawbacks of these methods include a lack of sensitivity for forensic applications; including an inability to quantitatively determine the concentration of gas present. The following study provides a validated method using HS-GC-MS which incorporates hydrogen sulfide as a suitable internal standard allowing the quantification of nitrous oxide. Upon analysis, sample and internal standard have similar retention times and are eluted quickly from the molecular sieve 5Å PLOT capillary column and the Porabond Q column therefore providing rapid data collection whilst preserving well defined peaks. After validation, the method has been applied to a real case of N2O intoxication indicating concentrations in a mono-intoxication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fluctuations in ammonium (NH4+), measured as NH4-N loads using an ion-selective electrode installed at the inlet of a sewage treatment plant, showed a distinctive pattern which was associated to weekly (i.e., commuters) and seasonal (i.e., holidays) fluctuations of the population. Moreover, population size estimates based on NH4-N loads were lower compared to census data. Diurnal profiles of benzoylecgonine (BE) and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH) were shown to be strongly correlated to NH4-N. Characteristic patterns, which reflect the prolonged nocturnal activity of people during the weekend, could be observed for BE, cocaine, and a major metabolite of MDMA (i.e., 4-hydroxy-3-methoxymethamphetamine). Additional 24 h composite samples were collected between February and September 2013. Per-capita loads (i.e., grams per day per 1000 inhabitants) were computed using census data and NH4-N measurements. Normalization with NH4-N did not modify the overall pattern, suggesting that the magnitude of fluctuations in the size of the population is negligible compared to those of illicit drug loads. Results show that fluctuations in the size of the population over longer periods of time or during major events can be monitored using NH4-N loads: either using raw NH4-N loads or population size estimates based on NH4-N loads, if information about site-specific NH4-N population equivalents is available.