61 resultados para Primary open-angle glaucoma
em Université de Lausanne, Switzerland
Resumo:
BACKGROUND AND PURPOSE: Transgenic mice overexpressing Notch2 in the uvea exhibit a hyperplastic ciliary body leading to increased IOP and glaucoma. The aim of this study was to investigate the possible presence of NOTCH2 variants in patients with primary open-angle glaucoma (POAG). METHODS: We screened DNA samples from 130 patients with POAG for NOTCH2 variants by denaturing high-performance liquid chromatography after PCR amplification and validated our data by direct Sanger sequencing. RESULTS: No mutations were observed in the coding regions of NOTCH2 or in the splice sites. 19 known SNPs (single nucleotide polymorphisms) were detected. An SNP located in intron 24, c.[4005+45A>G], was seen in 28.5% of the patients (37/130 patients). As this SNP is reported to have a minor allele frequency of 7% in the 1000 genomes database, it could be associated with POAG. However, we evaluated its frequency in an ethnic-matched control group of 96 subjects unaffected by POAG and observed a frequency of 29%, indicating that it was not related to POAG. CONCLUSION: NOTCH2 seemed to be a good candidate for POAG as it is expressed in the anterior segment in the human eye. However, mutational analysis did not show any causative mutation. This study also shows that proper ethnic-matched control groups are essential in association studies and that values given in databases are sometimes misleading.
Resumo:
Le glaucome est la seconde cause de cécité dans le monde après la cataracte et est caractérisé par la perte progressive de cellules ganglionnaires de la rétine allant vers la dégénérescence du nerf optique. On distingue deux formes de glaucome; le glaucome à angle fermé et le glaucome à angle ouvert. L'hérédité du glaucome est souvent sporadique, parfois autosomique dominante. Une pression intraoculaire de plus de 21 mmHg représente un facteur de risque important pour son développement. Actuellement, la mutation la plus fréquente, observée dans 5% des cas de glaucome héréditaire, est retrouvée dans le gène MYOC (trabecular meshwork inducible glucocorticoide response). À ce jour, les causes et mécanismes moléculaires sous-jacent ne sont que partiellement compris. Récemment, il a été démontré qu'une souris transgénique exprimant le gène Notch2 dans luvée, développait un glaucome. Pour cette raison, nous avons analysé le gène NOTCH2 chez l'homme afin de déterminer s'il était impliqué. NOTCH2 est composé de 34 exons sur le chromosome 1 et code une protéine transmembranaire essentielle à la prolifération, l'apoptose, la différenciation cellulaire et le destin cellulaires. L'expression du gène est localisée dans le segment antérieur de l'oeil, le segment externe du corps ciliaire et le trabéculum. Les fonctions principales de ces deux tissus sont la production et le drainage de l'humeur aqueuse. Pour mémoire, une perturbation du flux peut générer une augmentation de la pression intraoculaire. Le but de cette étude était de rechercher d'éventuelles mutations du gène NOTCH2 chez des patients souffrant de glaucome. 130 patients ont été vu à l'hôpital ophtalmique Jules- Gonin et un échantillon d'ADN a été récolté afin d'identifier l'origine moléculaire de leur pathologie. L'analyse moléculaire s'est fait étape par étape. Premièrement, j'ai séquencé l'exon 3 du gène MYOC. Deuxièment, la Chromatographie en phase liquide à haute performance a été utilisée pour l'analyse des 34 exons du gène NOTCH2. Troisièment, tous les exons présentant une courbe suspecte au chromatogramme ont été séquencés selon la méthode de Sanger. Dans la première partie de l'étude, j'ai analysé l'exon 3 du gène MYOC afin de déterminer les éventuels porteurs d'une mutation dominante. Aucune mutation pathogénique n'a été mis en évidence mais 4 patients sur les 130 étaient porteurs d'un variant connu et fréquent. Dans la deuxième partie de mon étude, j'ai analysé les 34 exons du gène NOTCH2, qui n'ont révélé aucune mutation. Bien que les méthodes utilisées dans cette étude montrent quelques limitations, il est peu probable que des mutations dans les régions codantes de NOTCH2 soient un facteur de risque important dans le glaucome primaire à angle ouvert.
Resumo:
BACKGROUND AND OBJECTIVE: To compare the efficacy and longevity of nonpenetrating glaucoma surgery with and without the use of a nonabsorbable hydrophilic implant at the Oxford Eye Centre, Johannesburg, South Africa, and the Glaucoma Unit, Jules Gonin Ophthalmic Hospital, Lausanne, Switzerland. PATIENTS AND METHODS: In a nonrandomized, prospective study between March 1997 and December 2001, 48 eyes of 32 patients aged 18 to 86 years with primary open-angle glaucoma underwent nonpenetrating glaucoma surgery; 25 eyes with the implant and 23 eyes without it. Intraocular pressure (IOP) was recorded preoperatively and postoperatively at 1, 7, and 14 days, at 1, 3, and 6 months, and thereafter every 6 months. RESULTS: The mean preoperative IOP was 27.5 +/- 11.8 mm Hg (range, 20 to 64 mm Hg) in the implant group and 24.8 +/- 7.1 mm Hg (range, 16 to 38 mm Hg) in the control group. During the first 18 months of follow-up, both groups showed identical IOP progression and the mean IOP remained less than 14 mm Hg. After 2 years of follow-up, the IOP started to rise in the control group but remained stable in the implant group. After 30 months, the mean IOP was 12.4 +/- 2 mm Hg and the IOP decrease in percentage was 62% +/- 6% in the implant group (n = 13) versus 16.1 +/- 3 mm Hg and 34% +/- 13% in the control group (n = 15) (mean IOP, P = .0022; mean IOP decrease in percentage, P = .01). CONCLUSIONS: During the first 18 months, there was no difference in the outcomes between the two groups. After 2 years of follow-up, the mean IOP was lower and the IOP decrease in percentage was greater in the implant group compared with the control group.
Resumo:
PURPOSE: Almost five years have elapsed since the introduction of latanoprost on several markets and considering the large number of publications dealing with it, the authors felt that it was worth re-evaluating the drug. METHODS: The criterion used to select trials for inclusion in the review was: all articles mentioning the drug in common electronic data-bases; these were then screened and considered, on the basis of methodological quality. RESULTS: Experimental data suggest that latanoprost acts by remodeling the extracellular matrix in the ciliary muscle, thus increasing the flow of aqueous humor through the ciliary muscle bundles of the uveoscleral pathway. POAG: Latanoprost persistently improves the pulsatile ocular blood flow in primary open angle glaucoma (POAG). Recent trials confirmed the greater IOP-lowering efficacy of latanoprost vs. timolol, dorzolamide, brimonidine and unoprostone. Trials lasting up to 24 months showed that latanoprost is effective in long-term treatment of POAG and ocular hypertension (OH), with no signs of loss of efficacy when compared to timolol or dorzolamide. Latanoprost provides better control of circadian IOP. Non-responders to beta-blockers should preferably be switched to latanoprost monotherapy before a combination therapy is started. The possibility of a fixed combination of latanoprost and timolol has been explored, with promising results. NTG: Latanoprost is effective in normal tension glaucoma (NTG), lowering IOP, improving pulsatile ocular blood flow and increasing ocular perfusion pressure. OTHER GLAUCOMAS: Latanoprost may provide effective IOP control in angle-closure glaucoma after iridectomy, in pigmentary glaucoma, glaucoma after cataract extraction and steroid-induced glaucoma. However, latanoprost was effective in only a minority of pediatric cases of glaucoma and is contraindicated in all forms of uveitic glaucoma. SAFETY: In the articles reviewed, new or duration-related adverse events were reported.
Resumo:
BACKGROUND: Selective laser trabeculoplasty (SLT) is a relatively new treatment strategy for the treatment of glaucoma. Its principle is similar to that of argon laser trabeculoplasty (ALT), but may lead to less damage to the trabecular meshwork. METHODS: We assessed the 2-year efficacy of SLT in a noncomparative consecutive case series. Any adult patient either suspected of having glaucoma or with open-angle glaucoma, whose treatment was judged insufficient to reach target intraocular pressure (IOP), could be recruited. IOP and number of glaucoma treatments were recorded over 2 years after the procedure. RESULTS: Our sample consisted of 44 consecutive eyes of 26 patients, aged 69+/-8 years. Eyes were treated initially on the lower 180 degrees . Three of them were retreated after 15 days on the upper 180. Fourteen eyes had ocular hypertension, 17 primary open-angle/normal-tension glaucoma, 11 pseudoexfoliation (PEX) glaucoma, and two pigmentary glaucoma. Thirty-six eyes had previously been treated and continued to be treated with topical anti-glaucoma medication, ten had had prior ALT, nine iridotomy, and 12 filtering surgery. The 2-year-follow up could not be completed for eight eyes because they needed filtering surgery. In the remaining 36 eyes, IOP decreased by a mean of 17.2%, 3.3 mmHg, (19.2+/-4.7 to 15+/-3.6 mmHg) after 2 years (p<0.001). As a secondary outcome, the number of glaucoma treatments decreased from 1.44 to 1.36 drops/patient. Other results according to subgroups of patients are analyzed: the greatest IOP decrease occurred in eyes that had never been treated with anti-glaucoma medication or with PEX glaucoma. SLT was probably valuable in a few eyes after filtering surgery; however, the statistical power of the study was not strong enough to draw a firm conclusion. When expressed in survival curves after 2 years, however, only 48% and 41% of eyes experienced a decrease of more than 3 mmHg or more than 20% of preoperative intraocular pressure, respectively. CONCLUSION: SLT decreases IOP somewhat for at least 2 years without an increase in topical glaucoma treatment. However, it cannot totally replace topical glaucoma treatment. In the future, patient selection should be improved to decrease the cost/effectiveness ratio.
Resumo:
AIM: To prospectively study the intraocular pressure (IOP) lowering effect and safety of the new method of very deep sclerectomy with collagen implant (VDSCI) compared with standard deep sclerectomy with collagen implant (DSCI). METHODS: The trial involved 50 eyes of 48 patients with medically uncontrolled primary and secondary open-angle glaucoma, randomized to undergo either VDSCI procedure (25 eyes) or DSCI procedure (25 eyes). Follow-up examinations were performed before surgery and after surgery at day 1, at week 1, at months 1, 2, 3, 6, 9, 12, 18, and 24 months. Ultrasound biomicroscopy was performed at 3 and 12 months. RESULTS: Mean follow-up period was 18.6+/-5.9 (VDSCI) and 18.9+/-3.6 (DSCI) months (P=NS). Mean preoperative IOP was 22.4+/-7.4 mm Hg for VDSCI and 20.4+/-4.4 mm Hg for DSCI eyes (P=NS). Mean postoperative IOP was 3.9+/-2.3 (VDSCI) and 6.3+/-4.3 (DSCI) (P<0.05) at day 1, and 12.2+/-3.9 (VDSCI) and 13.3+/-3.4 (DSCI) (P=NS) at month 24. At the last visit, the complete success rate (defined as an IOP of < or =18 mm Hg and a percentage drop of at least 20%, achieved without medication) was 57% in VDSCI and 62% in DSCI eyes (P=NS) ultrasound biomicroscopy at 12 months showed a mean volume of the subconjunctival filtering bleb of 3.9+/-4.2 mm3 (VDSCI) and 6.8+/-7.5 mm3 (DSCI) (P=0.426) and 5.2+/-3.6 mm3 (VDSCI) and 5.4+/-2.9 mm3 (DSCI) (P=0.902) for the intrascleral space. CONCLUSIONS: Very deep sclerectomy seems to provide stable and good control of IOP at 2 years of follow-up with few postoperative complications similar to standard deep sclerectomy with the collagen implant.
Resumo:
PURPOSE: To study prospectively the success rate and complications of deep sclerectomy with collagen implant (DSCI). SETTING: Glaucoma Unit, Department of Ophthalmology, Hôpital Ophtalmique Jules Gonin, University of Lausanne, Lausanne, Switzerland. METHODS: This nonrandomized prospective trial comprised 105 eyes of 105 patients with medically uncontrolled primary and secondary open-angle glaucoma. Visual acuity, intraocular pressure (IOP), and slitlamp examinations were performed before surgery and after surgery at 1 and 7 days, and 1, 3, 6, 9, 12, 18, 24, 30, 36, 48, 54, 60, 66, 72, 78, 84, 90, and 96 months. Visual field examinations were repeated every 6 months. RESULTS: Mean follow-up period was 64 months +/- 26.6 (SD). Mean preoperative IOP was 26.8 +/- 7.7 mm Hg, and mean postoperative IOP was 5.2 +/- 3.35 mm Hg at day 1 and 12 +/- 3 mm Hg at month 78. At 96 months, the qualified success rate (ie, patients who achieved IOP <21 mm Hg with and without medication) was 91%, and the complete success rate (ie, IOP <21 mm Hg without medication) was 57%. At 96 months, 34% of patients had an IOP <21 mm Hg with medication. Fifty-one patients (49%) achieved an IOP < or =15 mm Hg without medication. Neodymium:YAG goniopuncture was performed in 54 patients (51%); mean time of goniopuncture performance was 21 months, and mean IOP before goniopuncture was 20 mm Hg, dropping to 11 mm Hg after goniopuncture. No shallow or flat anterior chamber, endophthalmitis, or surgery-induced cataract was observed. However, 26 patients (25%) showed a progression of preexisting senile cataract (mean time 26 months; range 18 to 37 months). Injections of 5-fluorouracil were administered to 25 patients (23%) who underwent DSCI to salvage encysted blebs. Mean number of medications per patient was reduced from 2.3 +/- 0.7 to 0.5 +/- 0.7 (signed rank P<.0001). CONCLUSION: Deep sclerectomy with collagen implant appears to provide stable and reasonable control of IOP at long-term follow-up with few immediate postoperative complications.
Resumo:
Purpose: To study the filtering site using ultrasound biomicroscopy. (UBM) after posterior deep sclerectomy with Ex-PRESS? X-50 implant in patients undergoing filtering surgery.¦Methods: Twenty-six patients that participated in this prospective, non comparative study underwent a posterior deep sclerectomy and an Ex- PRESS? X-50 tube implantation. Clinical outcome factors recorded include: intraocular pressure, number of antiglaucoma medications, best corrected visual acuity (BCVA), frequency and types of complications. Six months postoperatively, an ultrasound biomicroscopy examination was performed.¦Results: Mean follow up was 12.0±3.4 months. Mean IOP decreased from 21 ±5.7 mmHg to 12.4±3 mmHg. At last follow-up examination, 65% of eyes had a complete success and 30% a qualified success. The mean number of antiglaucoma medications decreased from 2.5±1.2 preoperatively to 0.7±1 at the last follow-up postoperatively. BCVA was not changed. 27 complications were observed. On the UBM images, the mean intrascleral space volume was 0.25±0.27 mm3 and no relationship was found between volume and intraocular pressure reduction. We noted in 5/26 (19%) eyes a suprachoroïdal hypoechoic. Low-reflective blebs (L-type) were the most common: 15/26 (58%). No correlation between UBM findings and surgical success was evident.¦Conclusions: Deep sclerectomy with Ex-PRESS? X-50 tube implantation seems an efficient glaucoma surgery. It allows satisfactory IOP reduction with a low number of post operative complications. The advantages of deep sclerectomy with collagen implant are maintained with this modified technique. In both, the same reflective types of filtering blebs are present (high, low, encapsulated and flat). The UBM underlines the three mechanisms of aqueous humor resorption previously identified but no correlation with surgical success can be proved.¦-¦Ce travail de thèse est une analyse par ultrasonographic biomicroscopique (UBM) du site de filtration après sclérectomie profonde postérieure modifiée avec implantation d'un tube Ex- PRESS? X-50.¦Vingt six patients atteints d'un glaucome à angle ouvert, ont participé à cette étude prospective et non-comparative. Le critère d'inclusion est un glaucome à angle ouvert non contrôlé malgré un traitement topique maximal.¦Différents types de chirurgie filtrante sont effectués dans la chirurgie du glaucome dont la trabéculectomie et la sclérectomie profonde.¦L'intervention chirurgicale pratiquée dans cette étude consiste en l'implantation d'un tube Ex-PRESS? X-50 de format défini (3 mm de longueur et 50 μπι de diamètre interne) dans la chambre antérieure,au niveau du trabeculum, sous un volet scléral, ce qui permet le drainage de l'humeur aqueuse vers les espaces sous-conjonctivaux, avec diminution de la pression intraoculaire.¦Cette technique implique uniquement une dissection d'un volet scléral superficiel , sans volet scléral profond comme d'une sclérectomie profonde classique.¦Les modes de fonctionnement de cette sclérectomie profonde modifiée sont explorés par UBM, qui donne des images à haute résolution, semblables à des coupes anatomiques. Le volume de l'espace intrascléral créé artificiellement peut en effet être mesuré et mis en corrélation avec la pression intraoculaire et donc avec le taux de succès. Les différents types d'échogénécité de la bulle de filtration sous-conjonctivale provoquée par la dérivation de l'humeur aqueuse sont également observés. La présence éventuelle d'une filtration supplémentaire au niveau choroïdien est aussi détectée.¦De février 2007 à juin 2008, nous avons suivi chez les vingt six yeux des vingt six patients le volume intrascléral, la filtration sous-conjonctivale et la filtration choroïdienne le cas échéant, de même que l'acuité visuelle, la pression intraoculaire, le nombre de traitement antihypertenseur topique et les complications.¦Les résultats démontrent une réduction de 41 % par rapport à la pression intraoculaire préopératoire, ce qui est statistiquement significatif (p<0.0005). En ce qui concerne l'acuité visuelle, les valeurs demeurent stables. Par ailleurs, le nombre de médicaments antiglaucomateux diminue de façon significative de 2.5 ± 1.2 en préopératoire à 0.7 ± 1.0 au dernier examen (p<0.0005). Le volume de l'espace intrascléral, apparaissant toujours en échographie d'aspect fusiforme, n'est pas corrélé de façon significative avec un meilleur succès chirurgical bien que l'on aperçoive une tendance à une corrélation entre un plus grand volume et une pression intraoculaire plus basse.¦La classification la bulle de filtration se fait selon les 4 catégories de bulle de filtration décrites dans la littérature. La répartition révèle une majorité de type L soit hypoéchogène: 15/26 (58%) et une proportion identique, soit, 4/26 (16%), de bulles hyperéchogènes (type H) et encapsulées (type E); les bulles de filtration plates et hyperéchogènes (type F) sont les moins nombreuses 3/26 (11 %).¦La ligne hyporéflective visible dans 19 % des cas entre la sclère et la choroïde représentant potentiellement un drainage suprachoroïdien, n'est pas associée statistiquement à une meilleure filtration et une pression intraoculaire plus basse mais demeure une troisième voie de filtration, en plus de la filtration sous-conjonctivale et intrasclérale.¦En conclusion, cette technique différente, offrant une plus grande sécurité et des résultats satisfaisants sur l'abaissement de la pression intraoculaire, peut être, dans certains cas, une alternative à la sclérectomie profonde classique ,dont elle partage les mécanismes de filtration objectivés par ultrasonographic biomicrioscopique.
Resumo:
PURPOSE: To evaluate the long-term success rate and complications of nonpenetrating deep sclerectomy with collagen implant in open-angle glaucoma. PATIENTS AND METHODS: Clinical, prospective, monocentric, nonrandomized, unmasked study on 105 patients with medically uncontrolled glaucoma. A standard procedure deep sclerectomy with collagen implant was performed. Complete examinations were performed before surgery and postoperatively at 1 and 7 days; 1, 2, 3, 6, 9, and 12 months and then every 6 months during the 10 following years. RESULTS: The mean follow-up was 101.5+/-43.1 (3 to 144) months [mean+/-SD, (range)]. The preoperative intraocular pressure (IOP) was 26.8+/-7.7 (14 to 52) mm Hg and the best-corrected visual acuity 0.71+/-0.33 (0.02 to 1.5). Ten years after surgery IOP was 12.2+/-4.7 (6 to 20) mm Hg and best-corrected visual acuity 0.63+/-0.34 (0.01 to 1.2) (number of remaining patients=52). The mean number of medications per patient went from 2.3+/-0.7 (1 to 4) down to 1.3+/-1.1 (0 to 3). An IOP <or=21 mm Hg without medication was achieved in 47.7% patients and in 89% with or without treatment. One major complication was reported. Goniopuncture was performed in 61 eyes (59.8%), 5-fluorouracil treatment given to 25 patients postoperatively and included needling (n=5). CONCLUSIONS: On the basis of a 10-year follow-up deep sclerectomy with collagen implant demonstrated its efficacy in controlling IOP with few postoperative complications.
Resumo:
An 80-year-old male patient experienced recently diagnosed swelling of the limbal conjunctiva. In his clinical history were found cataract surgery on the right eye 3 months before, chronic open angle glaucoma effectively treated by local eye drops, treated systemic hypertension and hypercholesterolemia. On ophthalmic examination, a conjunctival mass was present in the inferior lateral conjunctival quadrant next to the limbus, with numerous vessels visible at its top. Treatment with topical corticosteroids failed to obtain regression, but decreased the local inflammatory signs. The persistence of the mass led to its surgical excision under local anesthesia. Histopathology found a subepithelial accumulation of modified collagen bundles typical of elastotic degeneration. Capillary vessels were seen in the superficial subepithelial area, attesting to the high degree of vascularization observed clinically. The final diagnosis was a pinguecula, which was not exactly located on the horizontal meridian area as it is usual.
Resumo:
PURPOSE: To compare the efficacy and safety of T-Flux implant versus Healon GV in deep sclerectomy. METHODS: Randomized prospective trial of 23 eyes of 20 patients with medically uncontrolled open angle glaucoma over a period of 24 months, who underwent deep sclerectomy with either Healon GV or T-Flux implant. RESULTS: Mean postoperative intraocular pressure was 13.2 +/- 3.0 mm Hg with T-Flux implant (group 1) and 12.2 +/- 3.5 mm Hg with Healon GV (group 2), with a pressure reduction of 53.0% in group 1 (13.2 mm Hg vs. 28.1 mm Hg) and of 48.1% in group 2 (12.2 mm Hg vs. 23.5 mm Hg). Qualified and complete successes were 100% and 95.4% respectively. Pressures equal to or less than 15 mm Hg were 81.8% in group 1 and 90.9% in group 2 with or without treatment, and 63.6% in group 1 and 81.8% in group 2 without treatment. The number of glaucoma treatments dropped from 2.5 +/- 0.9 to 0.4 +/- 0.7 in group 1 and from 2.2 +/- 1.0 to 0.2 +/- 0.4 in group 2. The goniopuncture rate was 63.6% in group 1 and 36.4% in group 2, with a mean pressure drop of 6.1 +/- 3.9 mm Hg and 3.25 +/- 1.2 mm Hg respectively. Overall, slit-lamp diagnosed surgery-related complications included positive Seidel (13.6%), hyphaema (22.7%), choroidal detachment, and iris incarceration (4.5% each). At 2 years, ultrasound biomicroscopy showed mainly low reflective (40.1%) and flattened (36.4%) blebs. Principally latter ones were associated with the need for adjunctive treatment. A hypoechoic area in the suprachoroidal space was seen in at least 59.1% of eyes at 2 years and was not associated with lower intraocular pressure. CONCLUSION: Deep sclerectomy is an effective and safe surgery. However, longer follow up and larger study groups are required to assess the additional benefit of nonabsorbable implants.
Resumo:
PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.
Resumo:
BACKGROUND: The aim of this study was to evaluate the mid-term biocompatibility of a new x-shaped implant made of zirconium in an animal model of glaucoma surgery. METHODS: Preoperatively, ultrasound biomicroscopy (UBM), intraocular pressure (IOP) and outflow facility (OF) data were acquired. Upon surgery, one eye was chosen randomly to receive an implant, while the other received none. Ten rabbits went through a 1-, 2-, 3-, 4- and 6-month follow-up. IOP was measured regularly, UBM performed at 1, 3 and 6 months after surgery. At the end of the follow-up, OF was again measured. Histology sections were analyzed. RESULTS: For both groups IOP control was satisfactory, while OF initially increased at month 1 to resume preoperative values thereafter. Eyes with implants had larger filtration blebs which decreased faster than in eyes without the implant. Drainage vessel density, inflammatory cell number and fibrosis were higher in tissues near the implant. CONCLUSIONS: The zirconium implant initially promoted the positive effects of the surgery (IOP control, OF increase). Nevertheless, after several months, foreign body reactions and fibrosis had occurred on some implants that restrained the early benefit of such a procedure. Modifications of the zirconium implant geometry could enhance the overall success rate.