4 resultados para Portable devices

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Screening for obstructive sleep apnea (OSA) is recommended as part of the preoperative assessment of obese patients scheduled for bariatric surgery. The objective of this study was to compare the sensitivity of oximetry alone versus portable polygraphy in the preoperative screening for OSA. METHODS: Polygraphy (type III portable monitor) and oximetry data recorded as part of the preoperative assessment before bariatric surgery from 68 consecutive patients were reviewed. We compared the sensitivity of 3% or 4% desaturation index (oximetry alone) with the apnea-hypopnea index (AHI; polygraphy) to diagnose OSA and classify the patients as normal (<10 events per hour), mild to moderate (10-30 events per hour), or severe (>30 events per hour). RESULTS: Using AHI, the prevalence of OSA (AHI > 10 per hour) was 57.4%: 16.2% of the patients were classified as severe, 41.2% as mild to moderate, and 42.6% as normal. Using 3% desaturation index, 22.1% were classified as severe, 47.1% as mild to moderate, and 30.9% as normal. With 4% desaturation index, 17.6% were classified as severe, 32.4% as mild, and 50% as normal. Overall, 3% desaturation index compared to AHI yielded a 95% negative predictive value to rule out OSA (AHI > 10 per hour) and a 100% sensitivity (0.73 positive predictive value) to detect severe OSA (AHI > 30 per hour). CONCLUSIONS: Using oximetry with 3% desaturation index as a screening tool for OSA could allow us to rule out significant OSA in almost a third of the patients and to detect patients with severe OSA. This cheap and widely available technique could accelerate preoperative work-up of these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The majority of transcatheter aortic valve implantations, structural heart procedures and the newly developed transcatheter mitral valve repair and replacement are traditionally performed either through a transfemoral or a transapical access site, depending on the presence of severe peripheral vascular disease or anatomic limitations. The transapical approach, which carries specific advantages related to its antegrade nature and the short distance between the introduction site and the cardiac target, is traditionally performed through a left anterolateral mini-thoracotomy and requires rib retractors, soft tissue retractors and reinforced apical sutures to secure, at first, the left ventricular apex for the introduction of the stent-valve delivery systems and then to seal the access site at the end of the procedure. However, despite the advent of low-profile apical sheaths and newly designed delivery systems, the apical approach represents a challenge for the surgeon, as it has the risk of apical tear, life-threatening apical bleeding, myocardial damage, coronary damage and infections. Last but not least, the use of large-calibre stent-valve delivery systems and devices through standard mini-thoracotomies compromises any attempt to perform transapical transcatheter structural heart procedures entirely percutaneously, as happens with the transfemoral access site, or via a thoracoscopic or a miniaturised video-assisted percutaneous technique. During the past few years, prototypes of apical access and closure devices for transapical heart valve procedures have been developed and tested to make this standardised successful procedure easier. Some of them represent an important step towards the development of truly percutaneous transcatheter transapical heart valve procedures in the clinical setting.