15 resultados para Pilot System

em Université de Lausanne, Switzerland


Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: There is limited safety information on most drugs used during pregnancy. This is especially true for medication against tropical diseases because pharmacovigilance systems are not much developed in these settings. The aim of the present study was to demonstrate feasibility of using Health and Demographic Surveillance System (HDSS) as a platform to monitor drug safety in pregnancy. METHODS: Pregnant women with gestational age below 20 weeks were recruited from Reproductive and Child Health (RCH) clinics or from monthly house visits carried out for the HDSS. A structured questionnaire was used to interview pregnant women. Participants were followed on monthly basis to record any new drug used as well as pregnancy outcome. RESULTS: 1089 pregnant women were recruited; 994 (91.3%) completed the follow-up until delivery. 98% women reported to have taken at least one medication during pregnancy, mainly those used in antenatal programmes. Other most reported drugs were analgesics (24%), antibiotics (17%), and antimalarial (15%), excluding IPTp. Artemether-lumefantrine (AL) was the most used antimalarial for treating illness by nearly 3/4 compared to other groups of malaria drugs. Overall, antimalarial and antibiotic exposures in pregnancy were not significantly associated with adverse pregnancy outcome. Iron and folic acid supplementation were associated with decreased risk of miscarriage/stillbirth (OR 0.1; 0.08 - 0.3). CONCLUSION: Almost all women were exposed to medication during pregnancy. Exposure to iron and folic acid had a beneficial effect on pregnancy outcome. HDSS proved to be a useful platform to establish a reliable pharmacovigilance system in resource-limited countries. Widening drug safety information is essential to facilitate evidence based risk-benefit decision for treatment during pregnancy, a major challenge with newly marketed medicines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND:The Swiss breast cancer screening pilot programme was conducted in 3 districts of theFrench-speaking canton of Vaud (ca. 300,000 resident women) between October 1993 and January 1999.Women aged 50 to 69 were invited by mail every 2 years for a free of charge screening mammography (doubleview, multiple reading). This first ever-organised cancer screening programme in Switzerland showed thefeasibility and acceptability of this kind of public health intervention in the liberal Swiss healthcare system, whichwas the main objective of the pilot programme. This mammographic screening programme was extended to thewhole canton in 1999, and contributed to the implementation of similar programmes in 2 neighbouring cantons. OBJECTIVE:To appraise the use, the quality and the effectiveness of the Swiss screening pilot programme. METHODS:About 15,000 women (aged 50-69) were enrolled. Logistic regression analyses were performedseparately to identify determinants of initial and subsequent attendance. Standard indicators of quality,effectiveness and impact of the programme were assessed and compared with European recommendations. Tothis intent, linkage with data from the Vaud Cancer Registry was performed. RESULTS:About half the target population was screened at least once during the pilot trial. Participation washigher among Swiss than foreigners, among widowed or married women than among single, divorced or separatedones. Attendance also increased with age and decreasing distance between residence and the dedicatedscreening centre. Apart from Swiss citizenship, socio-demographic factors were not associated with reattendance.Intensity of prior recruitment, outcome of previous screening test (positive vs. negative) and indicators of women'shealth behaviour (time of last mammography prior to initial screen, smoking status) were the main determinants ofreattendance. Programme performance and quality indicators were, overall, in line with European Guidelines. Theywere overall more favourable among 60-69 than 50-59 year-olds and improved over time. CONCLUSION:The objectives of the pilot programme were met. Even if participation should increase in order toreach European standards, performance indicators overall met quality requirements. Ways to improve screeninguse, quality and effectiveness were devised and taken into account for the generalisation of the programme.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Dissection during laparoscopic surgery produces smoke containing potentially toxic substances. The aim of the present study was to analyze smoke samples produced during laparoscopic colon surgery using a bipolar vessel sealing device (LigaSuretrade mark). METHODS: Four consecutive patients undergoing left-sided colectomy were enrolled in this pilot study. Smoke was produced by the use of LigaSuretrade mark. Samples (5,5l) were evacuated from the pneumoperitoneum in a closed system into a reservoir. Analysis was performed with CO2-laser-based photoacoustic spectroscopy and confirmed by a Fourier-transform infrared spectrum. The detected spectra were compared to the available spectra of known toxins. RESULTS: Samples from four laparoscopic sigmoid resections were analyzed. No relevant differences were noted regarding patient and operation characteristics. The gas samples were stable over time proven by congruent control measurements as late as 24 h after sampling. The absorption spectra differed considerably between the patients. One broad absorption line at 100 ppm indicating H2O and several unknown molecules were detected. With a sensitivity of alpha min ca 10-5 cm-1 no known toxic substances like phenol or indole were identified. CONCLUSION: The use of a vessel sealing device during laparoscopic surgery does not produce known toxic substances in relevant quantity. Further studies are needed to identify unknown molecules and to analyze gas emission under various conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study was to assess, at the European level and using digital technology, the inter-pathologist reproducibility of the ISHLT 2004 system and to compare it with the 1990 system We also assessed the reproducibility of the morphologic criteria for diagnosis of antibody-mediated rejection detailed in the 2004 grading system. METHODS: The hematoxylin-eosin-stained sections of 20 sets of endomyocardial biopsies were pre-selected and graded by two pathologists (A.A. and M.B.) and digitized using a telepathology digital pathology system (Aperio ImageScope System; for details refer to http://aperio.com/). Their diagnoses were considered the index diagnoses, which covered all grades of acute cellular rejection (ACR), early ischemic lesions, Quilty lesions, late ischemic lesions and (in the 2005 system) antibody-mediated rejection (AMR). Eighteen pathologists from 16 heart transplant centers in 7 European countries participated in the study. Inter-observer reproducibility was assessed using Fleiss's kappa and Krippendorff's alpha statistics. RESULTS: The combined kappa value of all grades diagnosed by all 18 pathologists was 0.31 for the 1990 grading system and 0.39 for the 2005 grading system, with alpha statistics at 0.57 and 0.55, respectively. Kappa values by grade for 1990/2005, respectively, were: 0 = 0.52/0.51; 1A/1R = 0.24/0.36; 1B = 0.15; 2 = 0.13; 3A/2R = 0.29/0.29; 3B/3R = 0.13/0.23; and 4 = 0.18. For the 2 cases of AMR, 6 of 18 pathologists correctly suspected AMR on the hematoxylin-eosin slides, whereas, in each of 17 of the 18 AMR-negative cases a small percentage of pathologists (range 5% to 33%) overinterpreted the findings as suggestive for AMR. CONCLUSIONS: Reproducibility studies of cardiac biopsies by pathologists in different centers at the international level were feasible using digitized slides rather than conventional histology glass slides. There was a small improvement in interobserver agreement between pathologists of different European centers when moving from the 1990 ISHLT classification to the "new" 2005 ISHLT classification. Morphologic suspicion of AMR in the 2004 system on hematoxylin-eosin-stained slides only was poor, highlighting the need for better standardization of morphologic criteria for AMR. Ongoing educational programs are needed to ensure standardization of diagnosis of both acute cellular and antibody-mediated rejection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The treatment of delusional depression is a major challenge in psychopharmacology. Hypothalamic-pituitary-adrenocortical (HPA) overdrive may contribute, via increased dopaminergic activity, to the pathophysiology of the disorder. Trimipramine appears to be an interesting potential candidate, since it is an atypical antidepressant that is known to inhibit HPA activity. In a four-week open trial we investigated its effects in 15 inpatients with delusional depression. The dosage was increased within 7 days up to 300 - 400 mg/d and was then maintained for three weeks. Psychometric assessments and safety monitoring were conducted weekly. Assessment of the HPA activity was achieved by a combined dexamethasone suppression/corticotropin-releasing hormone stimulation (Dex/CRH) test before and after four weeks of treatment. Therapeutic response was defined as a decrease in the HAMD-score of at least 50 %. Eight out of 13 completers were rated as responders. Therapeutic response was associated with L, D-trimipramine concentrations higher than 160 ng/ml. Intent-to-treat analysis showed significant improvement in psychometric variables. Despite the high dosage, the substance was generally well tolerated, with the exception of one patient who suffered from a hypotensive reaction. Mean +/- SD concentration of L-trimipramine and D-trimipramine were 138 +/- 61 ng/ml and 119 +/- 50 ng/ml at a final dose of 346 +/- 50 mg/d. The ACTH and cortisol area under the curve in the Dex/CRH tests decreased significantly, reflecting a decrease of activity in the HPA system. We suggest that the clinical use of high-dose trimipramine in delusional depression seems to be a promising treatment strategy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To determine the evolution of fear of falling, and its relationship with gait performance after a 10-week gait and balance training program. Population and methods: Participants (N=50) were community-dwelling elderly persons enrolled voluntarily in a 10-week, low intensity, gait and balance training program. At baseline, fear of falling was assessed using a previously validated version of Tinetti's Fall Efficacy Scale (FES, range 0-120, higher score indicating higher confidence), that assesses one's confidence in performing 12 activities of daily life without falling. Gait parameters were measured over a 20m walk at preferred gait speed, using the Physilog system (Aminian K, et al., J Biomechanics, 2002). This system uses 4 kinematics sensors attached to the lower limbs and a data logger carried by the subject. Follow-up data on fear of falling and gait were collected one week after completion of the program. Results: Overall, 43 (86%) of the participants completed the program. Mean age was 78.1 years, 79% were women. At baseline, mean FES score was 98.8 (range 58-120) and mean gait speed was 0.92 m/sec (range 0.43-1.47). At follow-up, participants modestly improved their FES score (98.8±17.0 vs 103.2±16.0, P=.04) and gait speed (0.92±0.27 vs 0.99±0.26 m/sec, P<.01). In secondary analyses stratified by subject's baseline FES, those with lower than average confidence (N=21) improved significantly both FES score (84.4±11.8 vs 94.5±17.9, P<.01) and gait speed (0.79±0.26 vs 0.90±0.28 m/sec, P<.01), while no similar improvement was observed in subjects (N=22) with higher baseline confidence (112.5±6.6 vs 111.5±7.5, P=.56 and 1.03±0.22 vs 1.07±0.21 m/sec, P=.41). After adjustment for age, gender and baseline gait speed, subjects with lower baseline confidence had higher odds than the others to improve their confidence (AdjOR=10.8, 95%CI 1.8- 64.8 P=.01) and gait speed (AdjOR=3.3, 95%CI 0.6-19.7, P=.19) at follow-up. Conclusions: This pilot program of low intensity exercise modestly improved participants' fear of falling and gait speed. Interestingly, subjects with higher baseline fear of falling seemed more likely to benefit. Despite methodological limitations (pre-post comparisons, small sample), these results suggest that measuring fear of falling might be useful to better target subjects most likely to benefit from similar programs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Tissue Renin-Angiotensin System activity is increased in obesity and may contribute to obesity-related hypertension and metabolic abnormalities. This open-label pilot study investigated the local effects of Aliskiren in adipose tissue and skeletal muscle.Methods: After a 1-2 week washout, 10 patients with hypertension and abdominal obesity received placebo for 2 weeks, then Aliskiren 300 mg once daily for 4 weeks, followed by a 4-week washout period and then another 4 weeks treatment period with Amlodipine 5 mg once daily. Drug concentrations and Renin-Angiotensin Systembiomarkers were measured in interstitial fluid employing the microdialysis zero-flow method, and in biopsies from abdominal subcutaneous adipose and skeletal muscle.Results: After 4 weeks treatment, microdialysate concentrations (mean±SD) of Aliskiren were 2.4±2.1 ng/ml in adipose tissue, and 7.1±4.2 ng/ml in skeletal muscle. These concentrations were similar to the mean plasma concentration of 8.4±4.4 ng/ml. Tissue concentrations (ng/g) of Aliskiren were 29.0±16.7 ng/g in adipose tissue, and 107.3±68.6 ng/g in skeletal muscle after 4 weeks treatment. Angiotensin II concentrations in microdialysates were below the lower limit of quantification in most patients, but pooled data from two patients suggested that Angiotensin II was reduced by Aliskiren and unchanged by Amlodipine. Aliskiren 300 mg significantly reduced mean plasma Renin activity by 68% and Angiotensin II by 61% (p<0.05 vs. baseline). Amlodipine 5 mg increased plasma Renin activity by 48% (p<0.05 vs. baseline), and non-significantly increased Angiotensin II by 60%. Both treatments increased plasma Renin concentration.Conclusion: Aliskiren 300 mg once daily penetrates adipose and skeletal muscle tissue at concentrations sufficient to reduce tissue Renin-Angiotensin System activity in obese patients with hypertension.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Ankle arthropathy is associated with a decreased motion of the ankle-hindfoot during ambulation. Ankle arthrodesis was shown to result in degeneration of the neighbour joints of the foot. Inversely, total ankle arthroplasty conceptually preserves the adjacent joints because of the residual mobility of the ankle but this has not been demonstrated yet in vivo. It has also been reported that degenerative ankle diseases, and even arthrodesis, do not result in alteration of the knee and hip joints. We present the preliminary results of a new approach of this problem based on ambulatory gait analysis. Patients and Methods: Motion analysis of the lower limbs was performed using a Physilog® (BioAGM, CH) system consisting of three-dimensional (3D) accelerometer and gyroscope, coupled to a magnetic system (Liberty©, Polhemus, USA). Both systems have been validated. Three groups of two patients were included into this pilot study and compared to healthy subjects (controls) during level walking: patients with ankle osteoarthritis (group 1), patients treated by ankle arthrodesis (group 2), patients treated by total ankle prosthesis (group 3). Results: Motion patterns of all analyzed joints over more than 20 gait cycles in each subject were highly repeatable. Motion amplitude of the ankle-hindfoot in control patients was similar to recently reported results. Ankle arthrodesis limited the motion of the ankle-hindfoot in the sagittal and horizontal planes. The prosthetic ankle allowed a more physiologic movement in the sagittal plane only. Ankle arthritis and its treatments did not influence the range of motion of the knee and hip joint during stance phase, excepted for a slight decrease of the hip flexion in groups 1 and 2. Conclusion: The reliability of the system was shown by the repeatability of the consecutive measurements. The results of this preliminary study were similar to those obtained through laboratory gait analysis. However, our system has the advantage to allow ambulatory analysis of 3D kinematics of the lower limbs outside of a gait laboratory and in real life conditions. To our knowledge this is a new concept in the analysis of ankle arthropathy and its treatments. Therefore, there is a potential to address specific questions like the difficult comparison of the benefits of ankle arthroplasty versus arthrodesis. The encouraging results of this pilot study offer the perspective to analyze the consequences of ankle arthropathy and its treatments on the biomechanics of the lower limbs ambulatory, in vivo and in daily life conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Studies assessing skin irritation to chemicals have traditionally used laboratory animals; however, such methods are questionable regarding their relevance for humans. New in vitro methods have been validated, such as the reconstructed human epidermis (RHE) model (Episkin®, Epiderm®). The comparison (accuracy) with in vivo results such as the 4-h human patch test (HPT) is 76% at best (Epiderm®). There is a need to develop an in vitro method that better simulates the anatomo-pathological changes encountered in vivo. To develop an in vitro method to determine skin irritation using human viable skin through histopathology, and compare the results of 4 tested substances to the main in vitro methods and in vivo animal method (Draize test). Human skin removed during surgery was dermatomed and mounted on an in vitro flow-through diffusion cell system. Ten chemicals with known non-irritant (heptylbutyrate, hexylsalicylate, butylmethacrylate, isoproturon, bentazon, DEHP and methylisothiazolinone (MI)) and irritant properties (folpet, 1-bromohexane and methylchloroisothiazolinone (MCI/MI)), a negative control (sodiumchloride) and a positive control (sodiumlaurylsulphate) were applied. The skin was exposed at least for 4h. Histopathology was performed to investigate irritation signs (spongiosis, necrosis, vacuolization). We obtained 100% accuracy with the HPT model; 75% with the RHE models and 50% with the Draize test for 4 tested substances. The coefficients of variation (CV) between our three test batches were <0.1, showing good reproducibility. Furthermore, we reported objectively histopathological irritation signs (irritation scale): strong (folpet), significant (1-bromohexane), slight (MCI/MI at 750/250ppm) and none (isoproturon, bentazon, DEHP and MI). This new in vitro test method presented effective results for the tested chemicals. It should be further validated using a greater number of substances; and tested in different laboratories in order to suitably evaluate reproducibility.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mirror therapy, which provides the visual illusion of a functional paretic limb by using the mirror reflection of the non-paretic arm, is used in the rehabilitation of hemiparesis after stroke in adults. We tested the effectiveness and feasibility of mirror therapy in children with hemiplegia by performing a pilot crossover study in ten participants (aged 6-14 y; five males, five females; Manual Ability Classification System levels: one at level I, two at level II, four at level III, three at level IV) randomly assigned to 15 minutes of daily bimanual training with and without a mirror for 3 weeks. Assessments of maximal grasp and pinch strengths, and upper limb function measured by the Shriner's Hospital Upper Extremity Evaluation were performed at weeks 0 (baseline), 3, 6 (intervention), and 9 (wash-out). Testing of grasp strength behind the mirror improved performance by 15% (p=0.004). Training with the mirror significantly improved grasp strength (with mirror +20.4%, p=0.033; without +5.9%, p>0.1) and upper limb dynamic position (with mirror +4.6%, p=0.044; without +1.2%, p>0.1), while training without a mirror significantly improved pinch strength (with mirror +6.9%, p>0.1; without +21.9%, p=0.026). This preliminary study demonstrates the feasibility of mirror therapy in children with hemiplegia and that it may improve strength and dynamic function of the paretic arm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Autologous brain cell transplantation might be useful for repairing lesions and restoring function of the central nervous system. We have demonstrated that adult monkey brain cells, obtained from cortical biopsy and kept in culture for a few weeks, exhibit neural progenitor characteristics that make them useful for brain repair. Following MPTP treatment, primates were dopamine depleted but asymptomatic. Autologous cultured cells were reimplanted into the right caudate nucleus of the donor monkey. Four months after reimplantation, histological analysis by stereology and TH immunolabeling showed that the reimplanted cells successfully survived, bilaterally migrated in the whole striatum, and seemed to have a neuroprotection effect over time. These results may add a new strategy to the field of brain neuroprotection or regeneration and could possibly lead to future clinical applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

While the hospital remains an important element of the psychiatric health-care system, the fact that it is always the best place to treat acute psychotic episodes is still debated. After a brief review of the literature relative to the main existing community care models, the authors describe the development in the Department Universitaire de Psychiatrie Adulte (DUPA), of an alternative to hospitalisation for patient going through a severe acute psychiatric episode. They present three clinical situations and the aims of the research project, which will follow this pilot phase.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Generic drugs have been advocated to decrease the proportion of healthcare costs devoted to drugs, but are still underused. Objective: To assess citizens' preferences for brand name drugs (BNDs) compared with generic drugs for treating acute and chronic conditions. Methods: A questionnaire with eight hypothetical scenarios describing four acute and four chronic conditions was developed, with willingness to pay (WTP) determined using a payment card system randomized to ascending (AO) or descending order (DO) of prices. The questionnaire was distributed with an explanation sheet, an informed consent form and a pre-stamped envelope over a period of 3 weeks in 19 community pharmacies in Lausanne, Switzerland. The questionnaire was distributed to every third customer who also had health insurance, understood French and was aged =16 years (up to a maximum of ten customers per day and 100 per pharmacy). The main outcome measure was preferences assessed by WTP for BNDs as compared with generics, and impact of participants' characteristics on WTP. Results: Of the 1800 questionnaires, 991 were distributed and 393 returned (pharmacy participation rate?=?55%, subject participation rate?=?40%, overall response rate?=?22%); 51.7% were AO and 48.3% DO. Participants were predominantly women (62.6%) and of median age 62 years (range 16-90). The majority (70%) declared no WTP for BNDs as compared with generics. WTP was higher in people with an acute disease than in those with a chronic disease, did not depend on the type of chronic disease, and was higher in people from countries other than Switzerland. Conclusions: Most citizens visiting pharmacies attribute no added value to BNDs as compared with generics, although some citizen characteristics affected WTP. These results could be of interest to several categories of decision makers within the healthcare system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Un système efficace de sismique tridimensionnelle (3-D) haute-résolution adapté à des cibles lacustres de petite échelle a été développé. Dans le Lac Léman, près de la ville de Lausanne, en Suisse, des investigations récentes en deux dimension (2-D) ont mis en évidence une zone de faille complexe qui a été choisie pour tester notre système. Les structures observées incluent une couche mince (<40 m) de sédiments quaternaires sub-horizontaux, discordants sur des couches tertiaires de molasse pentées vers le sud-est. On observe aussi la zone de faille de « La Paudèze » qui sépare les unités de la Molasse du Plateau de la Molasse Subalpine. Deux campagnes 3-D complètes, d?environ d?un kilomètre carré, ont été réalisées sur ce site de test. La campagne pilote (campagne I), effectuée en 1999 pendant 8 jours, a couvert 80 profils en utilisant une seule flûte. Pendant la campagne II (9 jours en 2001), le nouveau système trois-flûtes, bien paramétrés pour notre objectif, a permis l?acquisition de données de très haute qualité sur 180 lignes CMP. Les améliorations principales incluent un système de navigation et de déclenchement de tirs grâce à un nouveau logiciel. Celui-ci comprend un contrôle qualité de la navigation du bateau en temps réel utilisant un GPS différentiel (dGPS) à bord et une station de référence près du bord du lac. De cette façon, les tirs peuvent être déclenchés tous les 5 mètres avec une erreur maximale non-cumulative de 25 centimètres. Tandis que pour la campagne I la position des récepteurs de la flûte 48-traces a dû être déduite à partir des positions du bateau, pour la campagne II elle ont pu être calculées précisément (erreur <20 cm) grâce aux trois antennes dGPS supplémentaires placées sur des flotteurs attachés à l?extrémité de chaque flûte 24-traces. Il est maintenant possible de déterminer la dérive éventuelle de l?extrémité des flûtes (75 m) causée par des courants latéraux ou de petites variations de trajet du bateau. De plus, la construction de deux bras télescopiques maintenant les trois flûtes à une distance de 7.5 m les uns des autres, qui est la même distance que celle entre les lignes naviguées de la campagne II. En combinaison avec un espacement de récepteurs de 2.5 m, la dimension de chaque «bin» de données 3-D de la campagne II est de 1.25 m en ligne et 3.75 m latéralement. L?espacement plus grand en direction « in-line » par rapport à la direction «cross-line» est justifié par l?orientation structurale de la zone de faille perpendiculaire à la direction «in-line». L?incertitude sur la navigation et le positionnement pendant la campagne I et le «binning» imprécis qui en résulte, se retrouve dans les données sous forme d?une certaine discontinuité des réflecteurs. L?utilisation d?un canon à air à doublechambre (qui permet d?atténuer l?effet bulle) a pu réduire l?aliasing observé dans les sections migrées en 3-D. Celui-ci était dû à la combinaison du contenu relativement haute fréquence (<2000 Hz) du canon à eau (utilisé à 140 bars et à 0.3 m de profondeur) et d?un pas d?échantillonnage latéral insuffisant. Le Mini G.I 15/15 a été utilisé à 80 bars et à 1 m de profondeur, est mieux adapté à la complexité de la cible, une zone faillée ayant des réflecteurs pentés jusqu?à 30°. Bien que ses fréquences ne dépassent pas les 650 Hz, cette source combine une pénétration du signal non-aliasé jusqu?à 300 m dans le sol (par rapport au 145 m pour le canon à eau) pour une résolution verticale maximale de 1.1 m. Tandis que la campagne I a été acquise par groupes de plusieurs lignes de directions alternées, l?optimisation du temps d?acquisition du nouveau système à trois flûtes permet l?acquisition en géométrie parallèle, ce qui est préférable lorsqu?on utilise une configuration asymétrique (une source et un dispositif de récepteurs). Si on ne procède pas ainsi, les stacks sont différents selon la direction. Toutefois, la configuration de flûtes, plus courtes que pour la compagne I, a réduit la couverture nominale, la ramenant de 12 à 6. Une séquence classique de traitement 3-D a été adaptée à l?échantillonnage à haute fréquence et elle a été complétée par deux programmes qui transforment le format non-conventionnel de nos données de navigation en un format standard de l?industrie. Dans l?ordre, le traitement comprend l?incorporation de la géométrie, suivi de l?édition des traces, de l?harmonisation des «bins» (pour compenser l?inhomogénéité de la couverture due à la dérive du bateau et de la flûte), de la correction de la divergence sphérique, du filtrage passe-bande, de l?analyse de vitesse, de la correction DMO en 3-D, du stack et enfin de la migration 3-D en temps. D?analyses de vitesse détaillées ont été effectuées sur les données de couverture 12, une ligne sur deux et tous les 50 CMP, soit un nombre total de 600 spectres de semblance. Selon cette analyse, les vitesses d?intervalles varient de 1450-1650 m/s dans les sédiments non-consolidés et de 1650-3000 m/s dans les sédiments consolidés. Le fait que l?on puisse interpréter plusieurs horizons et surfaces de faille dans le cube, montre le potentiel de cette technique pour une interprétation tectonique et géologique à petite échelle en trois dimensions. On distingue cinq faciès sismiques principaux et leurs géométries 3-D détaillées sur des sections verticales et horizontales: les sédiments lacustres (Holocène), les sédiments glacio-lacustres (Pléistocène), la Molasse du Plateau, la Molasse Subalpine de la zone de faille (chevauchement) et la Molasse Subalpine au sud de cette zone. Les couches de la Molasse du Plateau et de la Molasse Subalpine ont respectivement un pendage de ~8° et ~20°. La zone de faille comprend de nombreuses structures très déformées de pendage d?environ 30°. Des tests préliminaires avec un algorithme de migration 3-D en profondeur avant sommation et à amplitudes préservées démontrent que la qualité excellente des données de la campagne II permet l?application de telles techniques à des campagnes haute-résolution. La méthode de sismique marine 3-D était utilisée jusqu?à présent quasi-exclusivement par l?industrie pétrolière. Son adaptation à une échelle plus petite géographiquement mais aussi financièrement a ouvert la voie d?appliquer cette technique à des objectifs d?environnement et du génie civil.<br/><br/>An efficient high-resolution three-dimensional (3-D) seismic reflection system for small-scale targets in lacustrine settings was developed. In Lake Geneva, near the city of Lausanne, Switzerland, past high-resolution two-dimensional (2-D) investigations revealed a complex fault zone (the Paudèze thrust zone), which was subsequently chosen for testing our system. Observed structures include a thin (<40 m) layer of subhorizontal Quaternary sediments that unconformably overlie southeast-dipping Tertiary Molasse beds and the Paudèze thrust zone, which separates Plateau and Subalpine Molasse units. Two complete 3-D surveys have been conducted over this same test site, covering an area of about 1 km2. In 1999, a pilot survey (Survey I), comprising 80 profiles, was carried out in 8 days with a single-streamer configuration. In 2001, a second survey (Survey II) used a newly developed three-streamer system with optimized design parameters, which provided an exceptionally high-quality data set of 180 common midpoint (CMP) lines in 9 days. The main improvements include a navigation and shot-triggering system with in-house navigation software that automatically fires the gun in combination with real-time control on navigation quality using differential GPS (dGPS) onboard and a reference base near the lake shore. Shots were triggered at 5-m intervals with a maximum non-cumulative error of 25 cm. Whereas the single 48-channel streamer system of Survey I requires extrapolation of receiver positions from the boat position, for Survey II they could be accurately calculated (error <20 cm) with the aid of three additional dGPS antennas mounted on rafts attached to the end of each of the 24- channel streamers. Towed at a distance of 75 m behind the vessel, they allow the determination of feathering due to cross-line currents or small course variations. Furthermore, two retractable booms hold the three streamers at a distance of 7.5 m from each other, which is the same distance as the sail line interval for Survey I. With a receiver spacing of 2.5 m, the bin dimension of the 3-D data of Survey II is 1.25 m in in-line direction and 3.75 m in cross-line direction. The greater cross-line versus in-line spacing is justified by the known structural trend of the fault zone perpendicular to the in-line direction. The data from Survey I showed some reflection discontinuity as a result of insufficiently accurate navigation and positioning and subsequent binning errors. Observed aliasing in the 3-D migration was due to insufficient lateral sampling combined with the relatively high frequency (<2000 Hz) content of the water gun source (operated at 140 bars and 0.3 m depth). These results motivated the use of a double-chamber bubble-canceling air gun for Survey II. A 15 / 15 Mini G.I air gun operated at 80 bars and 1 m depth, proved to be better adapted for imaging the complexly faulted target area, which has reflectors dipping up to 30°. Although its frequencies do not exceed 650 Hz, this air gun combines a penetration of non-aliased signal to depths of 300 m below the water bottom (versus 145 m for the water gun) with a maximum vertical resolution of 1.1 m. While Survey I was shot in patches of alternating directions, the optimized surveying time of the new threestreamer system allowed acquisition in parallel geometry, which is preferable when using an asymmetric configuration (single source and receiver array). Otherwise, resulting stacks are different for the opposite directions. However, the shorter streamer configuration of Survey II reduced the nominal fold from 12 to 6. A 3-D conventional processing flow was adapted to the high sampling rates and was complemented by two computer programs that format the unconventional navigation data to industry standards. Processing included trace editing, geometry assignment, bin harmonization (to compensate for uneven fold due to boat/streamer drift), spherical divergence correction, bandpass filtering, velocity analysis, 3-D DMO correction, stack and 3-D time migration. A detailed semblance velocity analysis was performed on the 12-fold data set for every second in-line and every 50th CMP, i.e. on a total of 600 spectra. According to this velocity analysis, interval velocities range from 1450-1650 m/s for the unconsolidated sediments and from 1650-3000 m/s for the consolidated sediments. Delineation of several horizons and fault surfaces reveal the potential for small-scale geologic and tectonic interpretation in three dimensions. Five major seismic facies and their detailed 3-D geometries can be distinguished in vertical and horizontal sections: lacustrine sediments (Holocene) , glaciolacustrine sediments (Pleistocene), Plateau Molasse, Subalpine Molasse and its thrust fault zone. Dips of beds within Plateau and Subalpine Molasse are ~8° and ~20°, respectively. Within the fault zone, many highly deformed structures with dips around 30° are visible. Preliminary tests with 3-D preserved-amplitude prestack depth migration demonstrate that the excellent data quality of Survey II allows application of such sophisticated techniques even to high-resolution seismic surveys. In general, the adaptation of the 3-D marine seismic reflection method, which to date has almost exclusively been used by the oil exploration industry, to a smaller geographical as well as financial scale has helped pave the way for applying this technique to environmental and engineering purposes.<br/><br/>La sismique réflexion est une méthode d?investigation du sous-sol avec un très grand pouvoir de résolution. Elle consiste à envoyer des vibrations dans le sol et à recueillir les ondes qui se réfléchissent sur les discontinuités géologiques à différentes profondeurs et remontent ensuite à la surface où elles sont enregistrées. Les signaux ainsi recueillis donnent non seulement des informations sur la nature des couches en présence et leur géométrie, mais ils permettent aussi de faire une interprétation géologique du sous-sol. Par exemple, dans le cas de roches sédimentaires, les profils de sismique réflexion permettent de déterminer leur mode de dépôt, leurs éventuelles déformations ou cassures et donc leur histoire tectonique. La sismique réflexion est la méthode principale de l?exploration pétrolière. Pendant longtemps on a réalisé des profils de sismique réflexion le long de profils qui fournissent une image du sous-sol en deux dimensions. Les images ainsi obtenues ne sont que partiellement exactes, puisqu?elles ne tiennent pas compte de l?aspect tridimensionnel des structures géologiques. Depuis quelques dizaines d?années, la sismique en trois dimensions (3-D) a apporté un souffle nouveau à l?étude du sous-sol. Si elle est aujourd?hui parfaitement maîtrisée pour l?imagerie des grandes structures géologiques tant dans le domaine terrestre que le domaine océanique, son adaptation à l?échelle lacustre ou fluviale n?a encore fait l?objet que de rares études. Ce travail de thèse a consisté à développer un système d?acquisition sismique similaire à celui utilisé pour la prospection pétrolière en mer, mais adapté aux lacs. Il est donc de dimension moindre, de mise en oeuvre plus légère et surtout d?une résolution des images finales beaucoup plus élevée. Alors que l?industrie pétrolière se limite souvent à une résolution de l?ordre de la dizaine de mètres, l?instrument qui a été mis au point dans le cadre de ce travail permet de voir des détails de l?ordre du mètre. Le nouveau système repose sur la possibilité d?enregistrer simultanément les réflexions sismiques sur trois câbles sismiques (ou flûtes) de 24 traces chacun. Pour obtenir des données 3-D, il est essentiel de positionner les instruments sur l?eau (source et récepteurs des ondes sismiques) avec une grande précision. Un logiciel a été spécialement développé pour le contrôle de la navigation et le déclenchement des tirs de la source sismique en utilisant des récepteurs GPS différentiel (dGPS) sur le bateau et à l?extrémité de chaque flûte. Ceci permet de positionner les instruments avec une précision de l?ordre de 20 cm. Pour tester notre système, nous avons choisi une zone sur le Lac Léman, près de la ville de Lausanne, où passe la faille de « La Paudèze » qui sépare les unités de la Molasse du Plateau et de la Molasse Subalpine. Deux campagnes de mesures de sismique 3-D y ont été réalisées sur une zone d?environ 1 km2. Les enregistrements sismiques ont ensuite été traités pour les transformer en images interprétables. Nous avons appliqué une séquence de traitement 3-D spécialement adaptée à nos données, notamment en ce qui concerne le positionnement. Après traitement, les données font apparaître différents faciès sismiques principaux correspondant notamment aux sédiments lacustres (Holocène), aux sédiments glacio-lacustres (Pléistocène), à la Molasse du Plateau, à la Molasse Subalpine de la zone de faille et la Molasse Subalpine au sud de cette zone. La géométrie 3-D détaillée des failles est visible sur les sections sismiques verticales et horizontales. L?excellente qualité des données et l?interprétation de plusieurs horizons et surfaces de faille montrent le potentiel de cette technique pour les investigations à petite échelle en trois dimensions ce qui ouvre des voies à son application dans les domaines de l?environnement et du génie civil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nursing workforce data are scarce in Switzerland, with no active national registry of nurses. The worldwide nursing shortage is also affecting Switzerland, so that evidence-based results of the nurses at work project on career paths and retention are needed as part of the health care system stewardship; nurses at work is a retrospective cohort study of nurses who graduated in Swiss nursing schools in the last 30 years. Results of the pilot study are presented here (process and feasibility). The objectives are (1) to determine the size and structure of the potential target population by approaching two test-cohorts of nursing graduates (1988 and 1998); (2) to test methods of identifying and reaching them 14 and 24 years after graduation; (3) to compute participation rates, and identify recruitment and participation biases.