4 resultados para Photonic Bandgap (PBG)

em Université de Lausanne, Switzerland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A traditional photonic-force microscope (PFM) results in huge sets of data, which requires tedious numerical analysis. In this paper, we propose instead an analog signal processor to attain real-time capabilities while retaining the richness of the traditional PFM data. Our system is devoted to intracellular measurements and is fully interactive through the use of a haptic joystick. Using our specialized analog hardware along with a dedicated algorithm, we can extract the full 3D stiffness matrix of the optical trap in real time, including the off-diagonal cross-terms. Our system is also capable of simultaneously recording data for subsequent offline analysis. This allows us to check that a good correlation exists between the classical analysis of stiffness and our real-time measurements. We monitor the PFM beads using an optical microscope. The force-feedback mechanism of the haptic joystick helps us in interactively guiding the bead inside living cells and collecting information from its (possibly anisotropic) environment. The instantaneous stiffness measurements are also displayed in real time on a graphical user interface. The whole system has been built and is operational; here we present early results that confirm the consistency of the real-time measurements with offline computations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A photonic system has been developed that enables sensitive quantitative determination of reactive oxygen species (ROS) - mainly hydrogen peroxide (H2O2) - in aerosol samples such as airborne nanoparticles and exhaled air from patients. The detection principle relies on the amplification of the absorbance under multiple scattering conditions due to optical path lengthening [1] and [2]. In this study, the presence of cellulose membrane that acts as random medium into the glass optical cell considerably improved the sensitivity of the detection based on colorimetric FOX assay (FeII/orange xylenol). Despite the loss of assay volume (cellulose occupies 75% of cell volume) the limit of detection is enhanced by one order of magnitude reaching the value of 9 nM (H2O2 equivalents). Spectral analysis is performed automatically with a periodicity of 5 to 15 s, giving rise to real-time ROS measurements. Moreover, the elution of air sample into the collection chamber via a micro-diffuser (impinger) enables quantitative determination of ROS contained in or generated from airborne samples. As proof-of-concept the photonic ROS detection system was used in the determination of both ROS generated from traffic pollution and ROS contained in the exhaled breath as lung inflammation biomarkers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During fluorescence cystoscopy, it is observed that the acquired images are sometimes blurred by a greenish background originating from the bladder washout fluid. Several fluorophores are involved in this overall liquid fluorescence, and their exact origin and relative contributions remain unknown. In this study, the bladder washout fluid is sampled at different times during fluorescence cystoscopy examinations. In total, 32 samples from 12 patients are analyzed with a spectrofluorimeter (excitation range: 350-445 nm, emission range 380-700 nm). This study shows clearly that the position of the fluorescence peaks (excitation/emission wavelengths: 450/525 nm, 405/625 nm) and shoulder (440/525 nm) is reproducible between different patients. It also suggests that an excitation at wavelengths higher than 400 nm helps to suppress this solution background fluorescence. Additionally, the pH of the solution seems to influence the position of the fluorescence peaks, and this suggests that changing the pH of the examination liquid could help in avoiding the greenish background.